Test lungs from IMT Analytics simulate a range of realistic ventilation situations during training.

Similar documents
Multi-Gas Analyzer. Multi-Gas Analyzer bcgroupintl.com. Features - MGA MGA-3050 Multi-Gas Analyzer

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

SLE5000 Infant Ventilator with HFO

VT650. Gas Flow Analyzer. Technical data. Key benefits and features:

Neonatal Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

Emergency Transport and Ventilation

Hospital and Transport for Controlled Breathing

CITREX H4 Mobile gas flow analyser. The ideal mobile device for flow and pressure analysing.»

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

SLE5000 Neonatal Ventilator with High Frequency Oscillation

An intuitive and innovative answer to your anaesthesia challenges

First and Only Disposable Infant T-Piece Resuscitator. Because they are not miniature adults...

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Infant Ventilators. Infant Ventilator with Touch-Screen Operation SLE4000

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

AkzentColor. Anesthesia. Anesthesia and excellent ventilation for neonatal, pediatric and adult patients

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

Infant Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

Dameca MRI 508. State-of-the-art MRI technology

Infant Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

Intensa GO Alternate Care Ventilator

V8800 Ventilator System. Your healthcare, we care.

Organis TestChest. Flight Simulator for Intensive Care Clinicians

Blease900 Ventilator PATIENT CENTERED VENTILATION

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

Oxylog VE300 Emergency & Transport Ventilation

fabian Therapy evolution Our 2-in-1 device

Oxylog 3000 plus Emergency & Transport Ventilation

Siesta i Whispa Integrated technology

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

MT The secret of harmonious breathing BABYLOG 8000 PLUS

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

GE Healthcare. Aestiva/5. More than superior ventilation

Mechanical Ventilation

Recommendations on Checking Anaesthesia Delivery Systems

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Minimum size for maximum performance

Advisedly design for all critical juncture. ihope RS/RV Series turbine based ventilatior

Your patients, our primary focus

IEC C LASSIFICATIONS:

Neonatal Care. Besmed products are manufactured under international quality standards for medical device and marked with CE.

The centerpiece of a comprehensive anaesthesia workstation

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Heated Wire - Neonate Ø10mm Infant Ø12mm

WILAmed INTENSA. Intensive Care Ventilator System

Solutions. Digital pressure management solutions. Copyright 2013 GaleMed Corporation

Astral in AirView: Improving patient care through connectivity. ResMed.com

6 th Accredited Advanced Mechanical Ventilation Course for Anesthesiologists. Course Test Results for the accreditation of the acquired knowledge

Oxygen Therapy Devices

Your patients, our primary focus. Siesta i Whispa anesthesia machine

fabian HFO Our 4-in-1 device

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Technical Data and Specifications

1st Response Disposable Manual Resuscitators. Safe Convenient Trusted

Giving neonates a future

NEONATAL VOLUME VENTILATION CLINICAL GUIDELINE V2.0

Entry to the premium class!

Great products available through ROI!

Selecting the right pressure sensor for your application

HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

Introducing Astral. Greater freedom. Confident care. Designed efficiency

Improve Process Reliability

State-of-the-art anesthesia technology

Milestones of Aeonmed Ventilators

APUS Anesthesia Machines

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Respiratory Care. and Aerosol Therapy

fabian HFO: Modular, Powerful, Versatile.

Astral in AirView: Improving patient care through connectivity. ResMed.com

Rad-57 Pulse CO-Oximeter

Intelligent Ventilation solution from ICU to MRI

respiratory care aerosol therapy

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

AUTOVENT 4000 VENTILATOR

BiPAP Vision Ventilator Testing with Various Patient Interfaces Report February 18, 2002

Oxylog Better to have one. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

INTENSIVE CARE VENTILATORS

Neonatal tidal volume targeted ventilation

Stephanie. Pediatrics. The ventilation system for neonatology

HAMILTON-T1 HAMILTON-T1. Intelligent transport ventilation

Using Common Ventilator Graphics to Provide Optimal Ventilation

Better to have one OXYLOG 3000

Oxygen Delivery Systems:

Respiratory. Products by Galemed

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

S/5 Aespire. Quick Reference Guide

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

KOALA. Disposable Adult Anaesthetic Circuits for Low Flow Anaesthesia KO.S5.22MM. Adult Anaesthetic Circuits. Medical Pty Ltd

Future technology, available today

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo

Advanced Ventilator Modes. Shekhar T. Venkataraman M.D. Professor Critical Care Medicine and Pediatrics University of Pittsburgh School of Medicine

Optimum oxygen supply for your patients! ATMOS Oxygen Supply

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

NeoNatalie Resuscitator Oxygen kit

Aespire 7100 Essential performance Compact design

Transcription:

Easy. Safe. Versatile. Test lungs from IMT Analytics are an easy and cost-effective way to reliably test the function and precision of ventilators and anaesthesia machines. Thanks to their adaptability they are ideal for using as part of training to simulate different types of ventilation. For example, they can be used to simulate inadequate application of volume due to unexpected leakages, or to test the accuracy of a ventilator for premature infants. The use of IMT Analytics test lungs prepares nursing personnel and ventilation specialists for every type of critical situation even during their training. Any risks associated with the use of ventilators can also be prevented by carrying out the simple functional and accuracy tests before using the equipment on patients. Simulating different patient conditions All tests that go beyond a simple functional check require an adaptable and adjustable test lung. This is the only way to check under real-life conditions how the ventilator responds to a change in patient condition. «A good test lung has a number of different settings for the airway resistance ranging from Rp5 to Rp200. The compliance (the stiffness of the lung) should be adjustable between 1 ml/mbar and 500 ml/mbar depending on how it is to be used. It should also have a infinitely variable leak setting to simulate leaking tubes, mask leaks and faulty connections. Based on these requirements, we developed the SmartLung. Test lungs from IMT Analytics simulate a range of realistic ventilation situations during training.» The sophisticated design means that IMT Analytics test lungs are compact and easy to operate. This makes them great for routine use. The low investment costs for our test lungs make them a reasonable alternative to other adjustable test lungs. Combined with an IMT Analytics Gas Flow Analyser, our instruments achieve maximum accuracy and are therefore a substitute for expensive test lungs with inaccurate measurement displays. Test lungs from IMT Analytics give me security before I ve even started the ventilation therapy.

SmartLung 2000 SmartLung Adult Using the new SmartLung 2000, you can test whether a ventilator meets the requirements of the following standards: IEC 60601-2-12, IEC 60601-2-13 and EN 794-3. 2000-mL bag Applicable volume from 0 to 1000 ml Testing according to IEC standards (ventilators and anaesthesia machines) The only test lung on the market that covers all the necessary test points Outstanding features for patient simulations in ventilator training Together with the SmartLung Adult, you can carry out a functional check for a ventilator across all standards. The SmartLung 2000 is the same size as conventional test lungs but has an adjustable compliance and a resistance that can be adjusted between Rp5 and Rp200. The adjustable leakage enables the user to verify the leak compensation of a ventilator. The patient trigger functions can also be verified. SmartLung Adult is designed to ideally simulate adult lungs and is impressive thanks to its compact design and versatility. 1000-mL bag Applicable volume from 0 to 600 ml The lung parameters resistance, compliance and leakage can be set to different levels Extremely handy and user friendly Top price-performance ratio SmartLung provides the same performance as larger and more expensive test lungs. It is compact, very easy to operate and can be connected directly to the ventilator tubing system. Considering its price-performance comparison, the SmartLung is unbeatable. Airway resistance, compliance (lung stiffness ) and leakage can be set to different levels. SmartLung saves you from the bulky benchtop equipment necessary for the large test lungs. Different bag sizes simulate all patient lungs from a baby to an adult. SmartLung does not require any additional adapters. The SmartLung 2000 is the ideal tool for testing ventilators and anaesthesia machines and the ideal supplement to FlowAnalyser and CITREX flow and pressure measurement devices. The slider can be adjusted to various lung compliance values without an adapter, allowing testing of various standards. The leakage simulation is infinitely variable and enables the ventilator to be tested for premature infants or mask ventilation. Even sensitive patient flow triggering can be reliably tested using the IMT Analytics SmartLung. Together with the FlowAnalyser or CITREX precision measuring devices from IMT Analytics, you can measure pressure, flow and volume with the SmartLung.

SmartLung Infant EasyLung SmartLung Infant simulates the lungs of young children while offering the same performance as its sister product, the SmartLung Adult. 500-mL bag Applicable volume from 0 to 200 ml The lung parameters resistance, compliance and leakage can be set to different levels Extremely handy and user friendly Top price-performance ratio SmartLung, the smart and cost-effective way to reliably test the function and precision of ventilators and anaesthesia machines. EasyLung The simple test lung for short routine tests. 1000-mL bag Volume cannot be adjusted Parts made from robust materials, autoclavable at 134 C Practical double taper connection with OD 22 and OD 15 Compact and cost-effective The EasyLung is a cost-effective, universally applicable test lung with many benefits for using with ventilators and anaesthesia machines. It can be used for validation purposes, for annual inspections or for routine short checks. The EasyLung combines a unique design with exchangeable parts made from high quality materials. The lung can be autoclaved at 134 C and thanks to its double taper connection provides the ideal option to connect to different patient tubing systems. High quality material High performance silicone bag individual parts Trusted IMT Analytics design

EasyLung Neonatal EasyLung Neonatal is the ideal test lung for checking neonatal ventilators. 20 ml @ PEEP = 0 mbar; PInsp = 30 mbar Compliance: 0.7 ml/mbar @Vt 20 ml 45 mm 150 mm Autoclavable Using the EasyLung Neonatal, you can simulate the exact and sensitive ventilation situation that occurs with very small premature infants, newborns or small children which requires maximum precision when dosing the tidal volume. The benefits of IMT Analytics test lungs individual parts Autoclavable High quality Durable material Patented Adjustable resistance Different airway resistances can be simulated by simply turning the connector. Leakage simulation The leakage can be adjusted by turning the screw on the side. Adjustable compliance Using the slider, various lung compliance values can be set without using an adapter. Handy and mobile Thanks to the practical carry bag, the test lung is always ready to go.

Summary of the technical specifications SmartLung Adult 2000 SmartLung Adult SmartLung Infant EasyLung EasyLung Neonatal Resistance 5, 25, 50, 200 mbar/l/s 5, 20, 50, 200 mbar/l/s 5, 20, 50, 200 mbar/l/s 20 mbar/l/s Compliance 25, 60, 75 ml/mbar 10, 15, 20, 30 ml/mbar 1, 2, 3, 5 ml/mbar 25 ml/mbar @ 0.7 ml/mbar @ Vt = 500 ml, PEEP = Vt = 20 ml 0 mbar Volume 0 1000 ml (with 2-L bag) 0600 ml (with 1-L bag) 0200 ml (with 0.5-L bag) 01000 ml (with 1-L bag) 0 20 ml Leakage Adjustable Adjustable Adjustable Weight 400 g 325 g 285 g 190 g 25 g Dimensions, L W H 400 140 40 mm 300 115 40 mm 270 115 40 mm 300 115 42 mm 150 45 45 mm Components Autoclavability Sterilisable Sterilisable Sterilisable Yes, at 134 C Yes, at 134 C Additional features Double taper connection (OD 22 taper, OD 15 taper)

Subject to changes without notice. 304.421.000_03, 2018-06 IMT Analytics AG. Gewerbestrasse 8. 9470 Buchs. Switzerland T +41 81 750 67 10. www.imtanalytics.com