GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Similar documents
Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

iworx Sample Lab Experiment HE-4: Respiratory Exchange Ratio (RER)

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

O 6 = 6 CO H 2 O H 2 = 16 CO 2. consumed during the oxidation of fatty acids, a ratio of 0.7.

Overview. Front Panel: Keypad and Display

Resting, Active, and Exercising Metabolic Rates

Application Note 268 Metabolic Analysis Systems and Propane-based Verification

Experiment HS-2: Breathing and Gravity

Recording established using the VO2 and RER graph template file (h19.gtl)

iworx Metabolic Accessories

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Application Note 183. Page 1 of Aero Camino, Goleta, CA Tel (805) Fax (805)

Columbus Instruments

O2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V

AKTA pure 25 New Owner s Intro

Restrictive and Obstructive Airway Diseases

RM-80 respiration monitor

Respiration. Exercise 1A: Breathing in Resting Volunteers Aim: To measure breathing parameters in a resting individual.

Biology 347 General Physiology Lab Basic Pulmonary Functions: Respirometry and Factors that Effect Respiration

Cardiovascular and respiratory adjustments to exercise

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel:

The University of Hong Kong Department of Physics Experimental Physics Laboratory

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

UNIVERSAL MASK TEST SYSTEM

User s Guide. Vacuum Controller for liquid delivery systems

User s Guide. Pressure Controller for liquid delivery systems

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Instruction and Maintenance Manual

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

AX5000 Operational Manual

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

Biology 347 General Physiology Lab Human Diving Response

Calibration of a GC955

6800 Maintenance Instruction System Flush Procedure

AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

Mass Flow Controller (MFC) for Gases

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Instruction and Maintenance Manual

Oxygen Meter User Manual

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Mass Flow Meter (MFM) for Gases

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

Armfield Distillation Column Operation Guidelines

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

System Overview. TCD Detector temperature setpoint Regulator

SHIMADZU LC-10/20 PUMP

Operator Quick Guide ORBISPHERE 3654

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Exploring the Properties of Gases

5890II GC Standard Operating Procedure 9/2/2005

Pneumatic high-pressure controller Model CPC7000

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

Aeroqual AirCal 1000 User Guide

FLUORESCENCE DETERMINATION OF OXYGEN

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

Aespire 7100 Essential performance Compact design

Boyle s Law: Pressure-Volume Relationship in Gases

5000TOC Sensor Standard Operating Procedure for TOC Calibration Conductivity Calibration Temperature Calibration Flow Rate Calibration

TR Electronic Pressure Regulator. User s Manual

Quadruple mass spectrometers (transducer type)

Mass Flow Controller (MFC) for Gases

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

LABORATORY INVESTIGATION

Pressure Sensor 150 to 1150 mbar Product Number: ENPRS015

Technical Bulletin. Seametrics Smart Sensors: Barometric Compensation (with optional DTW setting) Introduction. How Pressure is Measured

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

ACQUIDATA FAMILY CALIBRATION PROCEDURE CALIBRATION CHECKING

Gas Diluter Portable Gas Dilution System User s Manual

How to order guide. Spectronus FTIR Trace Gas Analyser. Version: 1.0

Constant Pressure Inlet (CCN) Operator Manual

EPP4 Pressure Regulator Basic G 1/4"

High Pressure Chem-SCAN Operating Manual

HumiSys HF High Flow RH Generator

C-Flow Coriolis Mass Flow Meters

Calculations of hydraulic resistance of simple pipelines for liquid viscous and non-newtonian products.

Instruction Manual. BZ7002 Calibration Software BE

Lab 1: Pressure and surface tension. Bubblers, gravity and the mighty paper clip.

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

PGA3510 Portable 3-Gas IR Analyzer. Operations Manual

Additel 780 Series Pressure Controller

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

KEM Scientific, Inc. Instruments for Science from Scientists

Experiment P18: Buoyant Force (Force Sensor)

OC508 Programmable mv Calibrator

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

Transcription:

Technical Note GA-300 Overview The GA-300 CO2 and O2 Gas Analyzer is easy to use, robust, and adaptable to human, animal, and plant applications. The GA-300 has two analog outputs to allow recording and display of O2 and CO2 gas concentrations on an iworx data acquisition system. In addition, the GA-300 incorporates an input for connection of a Polar Heart Rate Receiver. Front Panel GA-300 Front Panel On the front panel of the GA-300 are the analog CO2 and O2 outputs, an input and output for use with a Polar Heart Rate Receiver, the fan and power switches, and the connector for the 5 VDC power adapter. LabScribe is a trademark of 2015

Rear Panel GA-300 Rear Panel On the rear panel of the GA-300 Gas Analyzer are the inlet and outlet ports for the gas sampling tubing. How to Use the GA-300 Gas Analyzer Before the GA-300 Gas Analyzer is used, the following Two-Point Calibration procedure must be performed. Calibration of the O 2 and CO 2 Channels The outputs of the oxygen and carbon dioxide sensors of the GA-300 are voltages that are proportional to the concentrations of the gases being measured by the analyzer. To determine the volumes of oxygen consumed and carbon dioxide produced during metabolic testing, the voltage outputs of the sensors need to be converted, by the recording software, to the percentages of these gases in inhaled and exhaled air. To make this conversion, samples of two different known concentrations of oxygen, and two different known concentrations of carbon dioxide, will need to be entered into the GA-300 gas analyzer as the voltage outputs of each sensor are recorded. One set of samples can be taken from room air, which contains 20.93% O2 and 0.04% CO2. The other set of samples can be taken from gas cylinders containing a combination of these two gases at different concentrations. Cylinders containing both oxygen and carbon dioxide are readily available from suppliers. Some of the most commonly used combinations contain: 12% O2 and 5% CO2, with the balance being N2 16% O2 and 4% CO2

Recording the Voltage Outputs of the Gas Sensors Preparation: 1) Turn on the GA-300 for at least 15 minutes before performing a calibration. 2) Connect the CO2 and O2 outputs of the GA-300 to an iworx data acquisition system. Using a BNC cable, connect the CO 2 output to a BNC input on the data acquisition unit. Use a DIN8 cable to connect the O2 output to a DIN8 transducer input. 3) Double-click the desktop LabScribe icon to open LabScribe. 4) Configure LabScribe to show the O2 and CO2 channels. 5) Prepare the equipment that will deliver any gas samples, other than room air, to the GA-300: Clamp and secure near the GA-300 Gas Analyzer any gas cylinders that will be used to provide gas samples. Safely attach the regulator to the gas cylinder. Attach a Luer-Lock connector to the outlet of the regulator that will allow the Calibration Kit for the GA-300 to be connected to the regulator of the gas cylinder. Open the primary and secondary valves of the regulator for a few seconds to purge the air from the regulator. Close the secondary valve on the regulator to stop the flow of gas. You will need the cylinder for the second sample of gas. 6) Attach a filter to the inlet port on the rear of the GA-300 analyzer. Attach the smooth end of the sampling tubing to the inlet of the filter. Measure the voltage outputs of the oxygen and carbon dioxide sensors when measuring a sample of room air: 1) Move the gas sampling tubing away from the users to prevent the sampling of exhaled air. Allow room air to be pumped through the gas analyzer for 10 seconds before recording the outputs of the sensors. 2) Type Output Voltage-Room Air in the Mark text box to the right of the Mark button. 3) Click Record. The recording should scroll across the screen. 4) While recording, press the Enter key on the keyboard to mark the recording with information about the room air gas sample. 5) Record the outputs of the two gas sensors for about ten seconds. The recording should look like the data in the sample recording below. 6) Continue recording; do not stop recording until you have completed the following procedure.

The voltage outputs of the two sensors in the GA-300 gas analyzer, carbon dioxide on the top and oxygen on the bottom. Measure the voltage outputs of the oxygen and carbon dioxide sensors when measuring a second sample of a gas mixture containing known concentrations of oxygen and carbon dioxide: 1) Open the secondary valve on the regulator of the cylinder providing the second gas sample. Adjust the flow rate to LOW. 2) While the gas sample is flowing from the regulator, connect the gas sample tubing of the Calibration Kit (illustrated below) to the Luer-Lock connector on the output of the regulator. Turn off the flow of gas from the cylinder. Connect the outlet from the Calibration kit to the inlet filter port on the back of the GA-300. The GA-300 will pull the air in from the calibration tube. Turn the regulator of the canister on LOW. The gas sample will automatically be pulled into the GA-300. Too high a flow rate may damage the CO2 and O2 sensors.

GA-300 Calibration Kit 3) Type Output Voltage-Second Sample in the Mark text box. 4) While continuing to record, press the Enter key on the keyboard to mark the recording with information about the second gas sample. 5) Once the recordings of the gas concentrations reach a steady level, record for another ten seconds. This can take up to two minutes. 6) Click Stop. 7) Select Save As in the File menu and name the file. Choose a destination on the computer in which to save the file. Designate the file type as *.iwxdata. Click Save. Convert the Units on Gas Concentration Channels 1) Use the Display Time icons to adjust the Display Time of the Main window to show the complete calibration data on the Main window. 2) Place one cursor on the section of data recorded when the gas analyzer was collecting a sample of room air. 3) Place the second cursor on the section of data recorded when the second sample was collected. Convert the voltages at the positions of the cursors to concentrations using the Advanced Units Conversion Dialog: 1) To convert the voltages on the Expired CO2 Concentration (%) channel, click on the arrow to the left of the channel title to open the channel menu. Select Units from the channel menu, and select Advanced from the Units submenu.

2) On the Units Conversion dialog, make sure Apply units to the next recorded block is selected 3) Put a checkmark in the box next to Apply units to all blocks. 4) Move the two left hand vertical cursors to the flat line area where the voltage of room air was recorded. 5) Move the two right hand vertical cursors to the flat area where the voltage of the gas cylinder (from the calibration tube) was recorded, as shown in the example below. Advanced Units Conversion Dialog 6) Notice that the voltages from the positions of the cursors are automatically entered into the value equations. Enter the two concentrations of carbon dioxide measured from the two samples in the corresponding boxes on the right side of the conversion equations. If using room air, the concentration of CO2 = 0.04. The second gas concentration will be the one from the gas cylinder. 7) Enter the name of the units, %, in the box below the concentrations. 8) Click OK to activate the units conversion. 9) Repeat Steps 1 through 6 on the Expired O2 Concentration (%) channel. If using room air, the concentration of O2 is 20.9 The second gas concentration will be the one from the gas cylinder. 10) Enter the name of the units, %, in box below the concentrations. 11) Click OK to activate the units conversion. 12) Click Save.

Experiments LabScribe experiments that can be performed using the GA-300 Gas Analyzer include: Experiment HE-10: Aerobic Fitness Testing (found in the Human Exercise- GA300 category of the LabScribe Settings menu as AerobicFitness-GA300) Experiment HE-9: Resting, Active, and Exercising Metabolic Rates (found in the Human Exercise-GA300 category of the LabScribe Settings menu as RestActExerMetabolism-GA300) Experiment HE-5: Resting Metabolic Rate (RMR) (found in the Human Exercise-GA300 category of the LabScribe Settings menu as RMR-GA300) Experiment HE-4: Respiratory Exchange Ratio (RER) (found in the Human Exercise-GA300 category of the LabScribe Settings menu as VO2-RER- GA300) Technical Data and Specifications PERFORMANCE SPECIFICATIONS Ambient Temperature Atmospheric Pressure Warm-up Time Altitude Humidity 5-40 C operation 600 mmhg 912 mmhg 15 minutes Range 1-25% O 2 ; 0-10% CO 2 Resolution Flow with Pump Response Time Two point calibration required 10-95%, non-condensing ± 0.25% Oxygen ± 0.1% in 0-10% range ~250 ml/min 15 s@ 250 ml/min flow OTHER SPECIFICATIONS Power: Dimensions: 5 VDC, 2.5 A 10.5 x 5 x 14 centimeters 62 Littleworth Road, Dover, New Hampshire 03820 (T) 800-234-1757 / 603-742-2492 (F) 603-742-2455