Methods of Rating Flow

Similar documents
Engineering Information. Flow Data. Flow Data. Importance of Valve Sizing. Estimating Cv or Orifice Size:

Application Worksheet

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

Modeling a Pressure Safety Valve

09 - Choosing /sizing a cylinder and valve

Aspects of Flow Control in Metering Henry Gomes SGS Kuwait WLL

The Discussion of this exercise covers the following points:

Quick Reference Technical Data

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

The most common terms rating air flow capacity are ICFM, FAD, ANR, SCFM or nl/min

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

TECHNICAL INFORMATION

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.

Pressure and Temperature Controls

Air Cylinders Drive System Full Stroke Time & Stroke End Velocity

The Application of Temperature and/or Pressure Correction Factors in Gas Measurement

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

INTRODUCTION TO REGULATOR AND RELIEF VALVE SIZING. Introduction

Gerald D. Anderson. Education Technical Specialist

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

VB-7263 Series. Application. Features. Applicable Literature

VB-7273 Series. Application. Features. Applicable Literature

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

CONTROL VALVE WHAT YOU NEED TO LEARN?

Check & Demo Shielding Gas Waste. Index

Sizing Pulsation Dampeners Is Critical to Effectiveness

VBS-9263 Series. Application. Features. Applicable Literature

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

CONTROL VALVE SEAT LEAKAGE

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

INTERNATIONAL STANDARD

What is pressure relief valve? Pressure relief valve

1800CPB2 Pilot-Loaded Service Regulators

BACK PRESSURE / SUSTAINING

Models 106-RF / 206-RF Rate of Flow Control Valve

Engineering / Technical Section

Lab # 03: Visualization of Shock Waves by using Schlieren Technique

PRO-50 Instrument Supply Regulator

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Pressure on Demand. Air Pressure Amplifiers

Type 299 Pressure Reducing Regulators

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

1200 Series Pressure Regulators

Cavitation in Valves

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

PMI Pulse Decay Permeameter for Shale Rock Characterization Yang Yu, Scientist Porous Materials Inc., 20 Dutch Mill Road, Ithaca NY 14850

Model 1800 PFM Series Regulator. Technical Bulletin

Panel-mounted valves Series T, Ø 22.5 mm

The Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure

BACK PRESSURE / SUSTAINING

OVERVIEW. Flow Coefficient C v. Operating Conditions. Specific Gravity

The Hoffman Specialty Series 2000 consists of main

1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Air Eliminators and Combination Air Eliminators Strainers

North American Orifice Metering System

ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY

Air permeance of paper and paperboard (Sheffield method)

485 Annubar Primary Flow Element Installation Effects

Appendix A Frequently Asked Questions

ASX 176 Axial Pressure regulator

RECOMMENDATION FOR INTERCHANGEABLE FLANGED DRILLING CHOKE DIMENSIONS

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Control Valve Sizing. Sizing & Selection 3 P 1. P 2 (Outlet Pressure) P V P VC. CONTENTS Introduction Nomenclature Calculating C v

V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

Lesson 6: Flow Control Valves

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

Design and Application Details MICRO-RATIO Valves

Type Cronos Pressure Reducing Regulator

Noth American 7347 High Pressure Gas Regulators

V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

TECHNICAL INSTRUCTIONS Iron Body Series 597 SI

44 (0) E:

3-way control valves VK 3

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

SG TF. Q = 963 Cv (P1 - P2)(P1 + P2) TECHNICAL INFORMATION. Flow Q (GPM)

Expansion Tank Design (Chilled Water)

1800C and 1800C-HC Service Regulators

Single Tube Flowmeters

Hydronic Systems Balance

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Sizing Pressure Regulators & Control Valves

Technical Committee on LP-Gas at Utility Gas Plants

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

1800CPB2 Service Regulators

****** * EX * ****** DWN W.W.POWELL CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA AND DISCHARGE HEADERS ASSOCIATED WITH

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Squire-Cogswell

CORESTA RECOMMENDED METHOD N 6

Comments on Homework. Class 4 - Pressure. Atmospheric Pressure. Gauge vs. Absolute Pressure. 2. Gauge vs. Absolute Pressure. 1.

Laboratory Experiments No 1: Measuring the Number Distribution

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

S300 Series. Valve Link. Features. Fisher Controls

TECHNICAL DATA Q= C. Table 1 - Specifications

Multiple Tube Flowmeters

Example: Calculate the density of methane at 50 psig and 32 ⁰F. H.W. In previous example calculate the density of methane in gm/m 3.

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Transcription:

Methods of Rating Flow What engineers need to know when using CV as a measurement of flow in pneumatic applications In the pneumatic industry, CV is one standard for expressing the flow capacity of devices used in a pneumatic system. However, there are multiple other standards that also express flow capacity. Some common terms engineers might encounter include CV, C, effective orifice size, and normal liters per minute, as well as actual flow rates at specific pressure differentials. These terms are not interchangeable and even have slightly different meanings, interpretations, and formulas from one manufacturer to another. Therefore, it is important that engineers have a solid understanding of the data they are provided in order to prevent components from being oversized or undersized in pneumatic systems. This paper outlines the common methods that manufacturers utilize to express flow capacity. Clippard Instrument Laboratory www.clippard.com By Mike Kettering, Technical Sales Specialist Copyright 2018, Clippard Instrument Laboratory, Inc.

It is commonly understood that nearly every pneumatic device creates a flow restriction in the system. But By how much? The measurement and expression of that flow restriction is not always as straightforward as it may seem. This article outlines the common methods that manufacturers utilize to express flow capacity. In the pneumatic industry, CV (or more accurately, C v the coefficient of flow) is one standard for expressing the flow capacity of devices used in a pneumatic system. However, there are multiple other standards that also express flow capacity. Some common terms engineers might encounter include CV, C, effective orifice size, and normal liters per minute, as well as actual flow rates at specific pressure differentials. These terms are not interchangeable and even have slightly different meanings, interpretations, and formulas from one manufacturer to another. Therefore, it is important that engineers have a solid understanding of the data they are provided in order to prevent components from being oversized or undersized in pneumatic systems. Figure 1: Basic calculation for CV, where Q is the rate of flow (gallons per minute), SG is the specific gravity of the fluid, and P is the pressure drop across the valve (psi). Because air is compressible, CV must have additional factors built into the equation to compensate for that compressibility. WHAT YOU NEED TO KNOW ABOUT CV Many manufacturers around the world have adopted CV as the standard value to express the flow capacity of their components. CV is based on the volume flow rate of water at 60 F through a device within one minute at a 1 psi differential (Fig. 1). However, there is a problem with using this equation in pneumatic applications. Because air is compressible, CV must have additional factors built into the equations to compensate for that compressibility. For pneumatic applications, Figure 2: Example of how one manufacturer deviates from the ANSI/NFPA standard with their CV calculation; where Q is the rate of flow (standard cubic feet per hour), ΔP is the pressure drop across the valve (psi), P1 is the inlet pressure (psia), P2 is the outlet pressure (psia), SG is the specific gravity of the fluid at standard atmospheric pressure (60 F and 14.7 psia), T is the absolute temperature Rankine ( F + 460). CV should be calculated by referencing the appropriate formula and conditions outlined in the ANSI/NFPA T3.21.3 specification. When doing so, it is important that proper test conditions are observed. This includes ensuring that the pressure upstream of the component being tested is a nominal 95 psia, and that the differential between the upstream and downstream pressure of the component being tested is 1 psi. It is important to note that not every manufacturer expresses the flow capacity of their valves as CV based on the ANSI/NFPA specification. For 2 Methods of Rating Flow

example, at left (Fig. 2) is the calculation used by one manufacturer. The constant in the equation accounts for the difference in the specific gravity of air versus the specific gravity of water. This calculation does not follow the pressure requirements of the ANSI/NFPA specification. While the CV method is the most popular standard, its accuracy relies on manufacturers adhering to the same test procedures. Some manufacturers test and publish CV without any explanation of how they produce it, while others publish explanations but fail to follow the ANSI/NFPA T3.21.3 standard. Because CV only looks at a 1 psi differential, the calculated flow at low pressures can be very accurate, but certain applications that have higher differentials can produce flows that do not match the calculated results. It is important to be aware that misinterpreting the CV value can lead to differences in ratings of over 20%. USING SONIC CONDUCTANCE In place of CV, some manufacturers choose to publish C, the sonic conductance of a pneumatic component. This is defined by ISO 6358 and focuses on the sonic conductance of the component and the critical pressure ratio. The sonic flow condition of a valve is when it has reached the maximum possible flow. Increasing the pressure once sonic flow has been reached no longer increases flow. This condition is also known as choked flow. The critical pressure ratio is the ratio between downstream pressure and upstream pressure when the component has reached the maximum flow condition. Many manufacturers argue that subsonic flow data (C) is more reliable than CV because it is based on the maximum flow through a valve. With the C number plugged into an equation it is possible to calculate a flow rate for any pressure differential. However, some confuse C value with CV, which can lead to confusion and incorrectly sized components. While the CV method is the most popular standard, its accuracy relies on all manufacturers adhering to the same test procedures. THE BENEFITS OF USING EFFECTIVE ORIFICE The effective orifice size of a valve is relatively straight forward. This data corresponds to actual flow rates that would be achieved by simply putting an orifice in line. It is also known as the effective sectional area (the area of the effective orifice) and is related to the sonic conductance as the effective flow orifice is generally determined by empirically testing for the choked flow condition. The effective orifice method can have benefits since the flow can be expressed in one number that is easy to understand. There are many charts available which show similar CV s and flow rates for orifice sizes, but there is not an industry standard on testing valves to achieve an effective orifice. Some flow calculations use orifice sizes, so having the effective orifice size of a valve can reduce conversions and extra calculations in certain applications. While this method is great for general flow conditions, it can also be confusing since some manufacturers publish an orifice size which is not an effective orifice. Factors such as turbulence or poppet stroke of the valve make the actual valve orifice flow very different from the effective orifice flow. (Continued, p. 5) clippard.com 3

Pros Cons CV (Flow Coefficient) 4 Most popular 4 ANSI standard exists 4 Accurate with low pressure differentials 8 Not everyone follows the ANSI standard 8 Can provide different results if used at different pressure differentials 8 CV for water and CV for air can get confused with each other C (Sonic Conductance) 4 Based on ISO 6358 standard 4 Accurate with higher pressure differentials 8 Often confused with CV Effective Orifice 4 Orifice can easily be dropped into equations for calculating flow of different media 8 No industry standard on test conditions Nl/min (Normal Liters per Minute) 4 Widely used outside of the United States 8 No industry standard on test conditions 8 Converts to standard conditions which are not standardized 8 Often confused with SLPM Actual Flow 4 Based on the flow through the component to atmosphere 8 No industry standard on test conditions 4 Pros & Cons of Different Flow Measurements

NORMAL LITERS PER MINUTE Outside of the United States, it is common for pneumatic components to be published with a flow rate in normal liters per minute (Nl/min). Nl/min is a flow rating at a specific pressure with a 1 atm differential between the upstream pressure and the pressure downstream from the component. The flow is then converted to normal conditions, which are not always the same. Some commonly used normal conditions include: Temperature at 0 C, pressure at 1 atm, Temperature at 20 C, pressure at 1 atm, Temperature at 21 C, pressure at 1 atm, Temperature at 0 C, pressure at 1 bar, While these variances have minimal effect on flow ratings, the absence of a published standard for the normal condition creates some confusion in the industry. The normalized liter per minute method can be confusing since it takes the actual flow rate at a pressure differential and converts it to a flow rate at standard conditions. Different manufacturers have different standard conditions, but most publish Nl/min at a 1 atm differential. The 1 atm differential may be with 6 atm on the inlet and 5 atm on the outlet to achieve the 1 atm differential. This is important because that differential of 1 atm is not the same flow rate as 1 atm on the inlet of a valve and the exhaust to atmosphere. Flow rates between Nl/min and l/min to atmosphere can be vastly different. The Nl/min generally requires the engineer to calculate the flow rate back to the standard conditions. pressure rating of the valve and therefore expresses the maximum flow rate for that component. Other manufacturers take this a step further and publish flow charts that express the valve performance over the entire pressure range of the component. Some manufacturers provide a flow chart with this data to show how the flow rate changes as the pressure differential to atmosphere changes. For example, below (Fig. 3) Clippard lists the flow characteristics of their valves as a flow rate at a given pressure differential and provides a chart for the flow rate as the pressure differential changes. This makes it easy for engineers to determine the flow rate at a specific pressure and greatly reduces the possibility for confusion on the data. However, there is no industry standard for testing the actual flow rate of pneumatic components. CONCLUSION There are many methods in which the flow capacity of a component can be represented. The variety of methods that manufacturers use to express flow can vary from manufacturer to manufacturer as well as from one country to another which can seem overwhelming. However, with a basic understanding of the most popular methods, engineers can apply them properly in pneumatic systems to ensure properly sized components. EXPRESSING CAPACITY WITH ACTUAL FLOW Some manufacturers simply provide the actual flow the valve achieved at a specific pressure differential. This flow rate is often published for the maximum Figure 3: Flow chart example clippard.com 5

To request a free Clippard Full-Line Product Catalog, scan the code below or fill out the form online at: clippard.com/link/cvwp Clippard Instrument Laboratory www.clippard.com Copyright 2017, Clippard Instrument Laboratory, Inc.