Maintenance handbook

Similar documents
Assembly instructions

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Hydraulic Reliability & Preventive Maintenance Report

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Model Series 62 Constant Differential Relay

USER MANUAL Version: 1/2017

MUD 1. Vent check valves. Instruction and maintenance manual.

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

ACCU-PULSE Installation and Operation Instructions

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

Translation of the original Operating Instructions for HKS rubber compensators

PV4 and PV6 Piston Valves

Installation & Operation Manual Proven Quality since 1892

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Siphon vessel / Priming aid

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Unit 24: Applications of Pneumatics and Hydraulics

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

TECHNICAL DATA. Q = C v P S

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Manual Actuated Boiler Blowdown Valves

Operating and maintenance manual Filter and reducing station Series / 1.0

HPB25 Hydraulic Paving Breaker

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

PNEUMATIC STOPPERS OPERATING MANUAL. Type F G H - FOG

TECHNICAL DATA. Q = C v P S

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

TECHNICAL DATA. Q = C v P S

Installation and Maintenance Instruction Manual

OPERATION MANUAL NTF-15

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Installation, Operating & Maintenance Instructions. All-metal gate valve with extended pneumatic actuator. Series 48 DN mm (I.D.

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

M A B MAB INFLATABLE GASKET SLIDE VALVES SERIES TSV FOR POWDERED AND GRANULAR SOLID MATERIALS

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

2 Sentry MCL Installation, Operation & Maintenance

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

30T A/Manual Hydraulic Shop Press

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

TECHNICAL DATA. Q = C v P S

1. CONDITIONS FOR USE 2. SAFETY

Hydraulic Punch Drivers

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Straight-Way Valve with Packing Gland

Installation and operating instructions KEMPER Backflow Preventer BA Figure 361

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

Budget Range Operators Handbook

HIGH PRESSURE DRILLING FLUID PUMP

Operating Instructions in accordance with the Machines Directive 2006/42/EC

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

OWNER S TECHNICAL MANUAL

Pressure Independent Control Series

CAST IRON SAFETY VALVE TYPE 6301

OPERATION MANUAL NTF-60 Plus

Eaton Filtration, LLC

Fluid Sealing Association

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

TECHNICAL DATA. Q = C v P S

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Safety. April 2018 Supersedes all previous publications 2018 Chevron Phillips Chemical Company LP

Operating instruction

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

Ontario ENGINEERING STANDARD SPECIFICATION 1.0 PURPOSE

REV0709. Parts List. Hydraulic Cylinder Model MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER. Max. Capacity: 55.2 Tons at 10,000 PSI

Product Sheet Spraymist Unit

Gas Welding Hoses and connections, the weak link

Pressure Regulators. Operating Instructions. Instrumentation

Inert Air (N2) Systems Manual

Installation and Maintenance Instruction Manual

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

Troubleshooting Lift Cylinder Drift and Tilt Cylinder Drift

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

ESSENTIAL SAFETY RESOURCES

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation and Maintenance Instruction Manual

INTENDED USE TECHNICAL SPECIFICATIONS

Operation Manual Air Saver Unit ASV5000 Series

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: RT

Transcription:

Maintenance handbook

ontents HPU IDENTIFIATION SHEET... 4 1. MAINTENANE... 5 1.1 Filling level... 5 1.2 Fluid top-up... 5 1.3 Fluid replacing... 5 1.4 Fluid temperature control... 6 1.5 Functional control... 6 1.6 Maintenance operations... 6 1.7 Accumulator control... 6 1.8 Heat exchanger control... 7 1.9 Air filter control... 7 1.10 Oil filters control... 7 1.11 Leakages removing... 7 1.12 Piping... 7 1.13 External cleaning... 7 1.14 External inspection of tanks and steel components... 7 1.15 Exhaust fluid disposal... 8 2. PREVENTIVE MAINTENANE PROGRAM... 9 3. HANDBOOK OF REPAIRS AND MAINTENANE... 10

The user is obliged to comply with the maintenance program and monitoring as described on this handbook by filling in the handbook of repairs and maintenance. The replacement of E components must be submitted to ATOS written authorization. The use of non-original spare parts will void the warranty conditions (if they still exist) and Responsibilities of the Manufacturer. HPU IDENTIFIATION SHEET USTOMER: DRAWING NR.: SERIAL NUMBER: MANUFATURING MONTH/YEAR: NOMINAL PRESSURE: MAX PRESSURE PS: NOMINAL FLOW: MAINTENANE MANAGER: DATE OF OMMISSIONING: 4

1. MAINTENANE WARNING: - All activities of maintenance must be conducted by competent and qualified staff only - Always depressurize the relevant part of the system before any maintenance operation on the hydraulic power unit. The correct installation of the hydraulic power pack ensures a long life without particular maintenance operations, except those ones planned in the preventive maintenance program. (see Table page 8) These operations, in order to be effective, have to be regularly performed along the time. It is therefore very important that all the check-up operations, even if simple, are programmed and reported on specific maintenance program schedules. Before the inspection, cleaning should be undertaken if necessary. Always ensure cleanliness when working on the hydraulic power unit. WARNING: - Do not perform maintenance with the equipment functioning! - Penetrating dirt and liquids will cause faults! Safe function of the hydraulic power unit/components is then no longer ensured. Always ensure excellent cleanliness when working on the hydraulic power unit. - Damage to the surface from solvents and aggressive cleaning agents! Aggressive detergents may damage the seals on the hydraulic power unit and make them age faster. Never use solvents or aggressive detergents. - Damage to the hydraulic system and seals! The water pressure of a high-pressure cleaner can damage the seals of the hydraulic power unit. Do not use a high-pressure cleaner. Pay attention to prevent the detergents penetration into the hydraulic power unit. heck that all seals and electrical plug connections are firmly fitted to prevent the penetration of detergents. 1.1 Filling level The filling level should be checked at intervals during the first 8 operating hours. While the hydraulic power unit is in operation, the oil level will not remain constant. Level changes result from the different volume requirements of plunger and differential cylinder and/or the absorption/delivery of oil in hydraulic accumulators during a working cycle. Due to the variable conditions mentioned above, a complete working cycle of the machine must be observed when undertaking the visual inspection of the oil level. This will enable to determine whether the oil needs to be refilled or topped up. During operation, the oil level must neither exceed the upper mark nor fall below the lower mark. If the minimum filling level is undershot, there is a risk of pump failure due to cavitation. 1.2 Fluid top-up It must be performed every time the fluid level falls below the minimum. The maintenance can be facilitated by the use of electric minimum level indicators with additional pump stop function. Do not ever top up the oil above the maximum level. 1.3 Fluid replacing It has to be performed in accordance with fluid supplier prescriptions, as average every 2000-3000 working hours or, in case of seldom using, once a year; frequent checks of the fluid chemical-physical characteristics and of its contamination level allows to put in evidence the necessity of a prompt maintenance. When the fluid has to be replaced also the fluxing of the whole hydraulic system must be performed. 5

1.4 Fluid temperature control The fluid deterioration due to the temperature is one of the causes of the system degradation. The formation of deteriorated products is influenced by the temperature. The oxidation rate can be considered constant up to 60 ; starting from this point it doubles for each 10 of temperature increment. 1.5 Functional control Pumps, solenoid valves and regulation components have to be separately handled by a qualified personnel. It is possible to organize a programmed series of checks which can help to prevent eventual failures. Starting from the commissioning, it is recommended that the system is provided with a complete series of spare parts. 1.6 Maintenance operations In case of failure, after it has been identified, it is necessary to define if the repairing operation can be performed by the end user or by the manufacturer s qualified personnel. 1.7 Accumulator control For correct accumulator functioning, the pre-charge pressure (Po) has to be kept constant and it has to be checked every three months using proper equipment. WARNING: Before any maintenance operation, make sure that the accumulator is not under pressure. It s customer responsibility to maintain the accumulator and to register the information. To modify the pre-charge pressure of the accumulators, always refer to qualified personnel. Accumulators must be pre-charged only with Nitrogen. RISK OF PERSONAL INJURY AND DAMAGE TO PROPERTY! Accumulators are a potential source of hazards. Leaking pressurized gas may result in serious injury or even death. Particular care must be taken when working on hydraulic systems with accumulators, as inappropriate behavior may result in serious injury. - Never perform welding or soldering work or any mechanical processing on accumulators! If air or oxygen is used as means of accumulation, there is a high risk of explosion! If uncleaned gases are used, the contaminating substances contained therein or the water content may lead to unforeseeable and uncontrollable behavior of the device. - Only use nitrogen as gas in the accumulator (Nitrogen lass 4.0 purest; N2: 99.99 Vol-%)! When draining the nitrogen from the accumulator, the composition of the air is changed. In very small rooms, this may result in fainting or even suffocation. - Before discharging the nitrogen accumulator pressure, the doors and windows of the room, in which the accumulator is located, must be opened. The draining of the nitrogen from the accumulator may result in an excessive increase in pressure. - Before discharging the nitrogen accumulator pressure, the doors and windows of the room, in which the accumulator is located, must be opened. There are legally prescribed inspections for accumulators, which have to be undertaken at defined intervals. This is the responsibility of the customer. In order for the accumulator to function as intended, the gas pre-charge is to be checked periodically according to the information in the preventive maintenance program. (see Table page 9) Due to the fast discharge of the gas pressure, the components and component parts affected will be subjected to extreme cooling. In extreme cases, contact with unprotected skin may even result in supercooling in the form of burns! - You should wear thermal gloves and avoid contact with the supercooled components. Wait for a reasonable period of time until the supercooled components have reached ambient temperature once more. 6

1.8 Heat exchanger control The heat exchangers have to be cleaned about every six months, the maintenance frequency depends from the quality of the used water in case of water/fluid exchangers and to the environmental conditions (high density of dust) in case of the air/fluid exchangers. The daily check of the fluid temperature is useful to put in evidence the progressive deterioration of the thermal exchange and the consequent necessity of maintenance. 1.9 Air filter control To be monthly performed with the eventual replacement of the filtering cartridge. 1.10 Oil filters control Effective contamination control can be assured by the correct use of clogging indicators (optical or electrical). This operation is of the maximum importance and shall be performed at least weekly. In case an electrical indicator is present, the fault signal is directly indicated on the control panel, so that automatic sequences to block the circuit can be set up. onsidering that the cartridges shall be replaced every time the filters clogging indicators indicate this need, it is however highly recommended to replace the cartridges at least once a year. 1.11 Leakages removing The leakages from pipes are usually removed by tightening the fittings that could self-unlock due to the vibrations and/or system temperatures. In case of leakages from the mounting surfaces, the relevant seals must be replaced with new ones. Replace the O-Ring seals of mounting surfaces every time that the valve is removed from its mounting position. 1.12 Piping The piping consists of the pipes and the connection elements. onnection types: - Form-type fitting - Flare-type fitting - Welded fitting - ompression joint - Flange connection The piping must be checked at least once every six months (or more frequently depending on operating conditions and use). In order to allow for a visual inspection, prior cleaning may be required. There is an inspection for: - orrosion - rack formation - Leaks - Indication of the application of external force 1.13 External cleaning To be performed every three months at least. It facilitates an easy identification of external leakages and thus an immediate corrective action. 1.14 External inspection of tanks and steel components The external inspection is a visual one and must be undertaken at least once every six months (or more frequently depending on operating conditions and use). In order to allow for a visual inspection, prior cleaning may be required. There is a visual inspection for: - Leaks - rack formation - orrosion - Dents due to the application of external force. 7

1.15 Exhaust fluid disposal The exhaust fluid have to be stocked in sealed containers to be located in insulated areas. WARNING: It is forbidden to store the containers outdoor and on absorbing land. Exhausted fluid should be withdrawn only by specialized companies for disposal in strict observance of the laws in force in the country. Accumulators and nitrogen bottle must be preventively discharged. At the time of decommissioning and disposal, in addition to the above mentioned warnings, it is important to separate the plastic parts that have to be sent to collection in accordance with the regulations. The metal parts of the power unit can be sent to recycling for melting. The decommissioning/disposal does not present special risks, as long as it is carried out by sufficiently prepared staff, equipped with adequate means. 8

2. PREVENTIVE MAINTENANE PROGRAM Frequency Inspection / Replacement Every Day Every Week Every Month *Every Three Months *Every Six Months *Every Year Fluid level Fluid temperature Fluid ontamination logging indicators Suction filters R Pressure Filter s cartridges R Return Filter s cartridges R Air Filters R Heat exchanger alibration of working pressures alibration of pump s flow Accumulators Pre-harge pressure (if present) F Pipes (Leakage or damage) Flexible Pipes (Leakage or damage) Elastic insert junction motor/pump R LEGEND : check : contamination control R: replace F: check by mean of dedicated instrument Program planned for non-stop working cycles 24 hours a day *Registration of quarterly,semi-annual and annual inspections/replacements is mandatory within warranty period 9

3. HANDBOOK OF REPAIRS AND MAINTENANE Date *Type Description Operator Signature *Assistance type: O = ordinary S = special 10

HANDBOOK OF REPAIRS AND MAINTENANE Date *Type Description Operator Signature *Assistance type: O = ordinary S = special 11

HANDBOOK OF REPAIRS AND MAINTENANE Date *Type Description Operator Signature *Assistance type: O = ordinary S = special 12