DANGER WARNING IMPORTANT

Similar documents
SL G3. Warning

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

/2004 US/CA

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

Installation Instructions

Propane Conversion Kit Instruction

Natural Gas to L.P. Gas Conversion Kit

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

Your safety and the safety of others are very important.

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Natural Gas to L.P. Gas Conversion Kit

Installation Instructions For Natural Gas Conversion

Propane Conversion Kit Instruction

INSTALLATION INSTRUCTIONS

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Installation Instructions

ACCESSORY KIT INSTALLATION MANUAL

Propane Conversion Kit Instruction

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

installation instructions

Conversion instructions from natural gas to propane

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Propane Conversion Kit Instructions

Natural Gas Conversion Kit

ACCESSORY KIT INSTALLATION INSTRUCTIONS

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

Instructions for High Altitude Conversion

Gas Fired Residential Heating Boilers

USER S INFORMATION MANUAL

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

36H SERIES Combination Gas Valve

INSTALLATION INSTRUCTIONS

OC Panel High Limit Aquastat Kit, Manual Reset p/n

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Gas Valve Replacement Kit

INSTALLATION INSTRUCTIONS

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

WARNING: AVERTISSEMENT. LP & HIGH ALTITUDE LP CONVERSION KIT FOR INSTALLATIONS IN the United STATES (0-10,000 Ft)

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28

Operator: Save these instructions for future use!

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

G96 Series BASOTROL Dual Operator Valve

Operator: Save these instructions for future use!

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41

GM Series Dual-Block Multi-Function Gas Control Valves

WARNING: FOR OUTDOOR USE ONLY

Operator: Save these instructions for future use!

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

LNVx Gas Conversion Kit Instructions

GAS CONVERSION KIT Installation Instructions Range/Rangetop

Installation Instructions

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

INSTALLATION INSTRUCTIONS

GM-7000 Series CE Approved Gas Control Valve

Gas Conversion Kit Pilot Ignition Heaters

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Natural Gas Conversion Kit

INSTALLATION AND OPERATION INSTRUCTIONS

C645A-E Pressure Switches

SPECIFICATIONS ATTENTION

Gas Countertop Griddle

VR8205S,T Direct Ignition Combination Gas Controls

Technical

VR8200A Continuous Pilot Combination Gas Controls

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

Installation Instructions

INSTALLATION GUIDE Gas Rangetops

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

Instruction Manual No. 742, 8/98

G92 Series BASOTROL Automatic Pilot Gas Valve

For *G7 / *GC2 & GUH* / GDD* Series Furnaces & Appliances Using Honeywell Gas Valves

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

CASUAL FIRESIDE A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR FIRE PIT FOR PROPANE AND *NATURAL GAS

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

INSTALLATION INSTRUCTIONS

Valve Proving System VDK 200 A S06*

VR8305 Direct Ignition Combination Gas Control

INSTALLATION AND OPERATING INSTRUCTIONS

SERVICE MANUAL. UDS / UDH Series Ultra Low NOx Direct Vent Water Heaters. Troubleshooting Guide and Instructions for Service

Unipower VA Series. OEM Installation & Start Up Instructions. Variable Air Gas Burners OEM Start Up IHEA U L. Quality Designed for Proven Performance

Operator: Save these instructions for future use!

Transcription:

BWC Series Instructions for Field Conversion From: Natural Gas to LP LP to Natural Gas D E S I G N E D T O L E A D DANGER These instructions include a procedure for adjusting the air-fuel mixture on this boiler. This procedure requires a combustion analyzer to measure the C (or Oxygen) and Carbon Monoxide (CO) levels in flue gas. Adjusting the air-fuel mixture without a proper combustion analyzer could result in unreliable boiler operation, personal injury, or death due to carbon monoxide poisoning. WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, an explosion or production of carbon monoxide may result causing property damage, personal injury, or loss of life. The qualified service agency is responsible for proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit. IMPORTANT Not all BWC Series boilers may be used on both natural and LP gas. Before attempting a field conversion, refer to Table 1 to verify that the planned conversion is permitted.

In addition to these instructions, this kit consists of the following items: Part Number Description Color 980236 Natural to LP Conversion Label Sheet ( 1 of 2) Red 980246 Natural to LP Conversion Label Sheet ( 2 of 2) Red 980237 LP to Natural Conversion Label Sheet (1 of 2) Yellow 980247 LP to Natural Conversion Label Sheet (1 of 2) Yellow 1) Make sure that the planned fuel conversion is listed in Table 1. If the planned conversion is not shown in Table 1, it is not permitted. Some of the models shown below may be equipped with either a Dungs or Honeywell gas valve. Refer to Figures 1 and 2 to identify the valve used on the model being converted. Table 1: Permitted Conversions Boiler Model Gas Valve Fuel Converted Planned From To Installation Altitude BWC070EN Dungs GB-WND 055 (HO) Natural Gas LP 0-10200ft BWC070EL Dungs GB-WND 055 (HO) LP Natural Gas 0-10200ft BWC090EN Dungs GB-WND 055 (HO) Natural Gas LP 0-10200ft BWC090EL Dungs GB-WND 055 (HO) LP Natural Gas 0-10200ft BWC120EN Dungs GB-WND 055 (HO) Natural Gas LP 0-7800ft BWC120EL Dungs GB-WND 055 (HO) LP Natural Gas 0-10200ft BWC150EN* Dungs GB-WND 055 (RH)* Natural Gas LP 0-7800ft BWC150EL Dungs GB-WND 055 (RH) LP Natural Gas 0-10200ft BWC151EN Dungs GB-WND 055 (HO) Natural Gas LP 0-7800ft BWC151EL Dungs GB-WND 055 (HO) LP Natural Gas 0-10200ft BWC225EN** Honeywell VK8115 Natural Gas LP 0-7800ft BWC225EL Honeywell VK8115 LP Natural Gas 0-10200ft BWC300EN Dungs GB-WND 057 Natural Gas LP 0-10200ft BWC300EL Dungs GB-WND 057 LP Natural Gas 0-10200ft BWC399EN Dungs GB-WND 057 Natural Gas LP 0-10200ft BWC399EL Dungs GB-WND 057 LP Natural Gas 0-10200ft BWC425EN Dungs GB-WND 057 Natural Gas LP 0-10200ft BWC425EL Dungs GB-WND 057 LP Natural Gas 0-10200ft * Conversion of BWC150 EN boilers equipped with Honeywell gas valves to LP is not permitted. ** Do not attempt to convert BWC225EN to LP at altitudes above 2000 ft unless the manufacturing date on the rating plate is after 6/1/10. 2) Conversion of BWC series boilers from one fuel to another is accomplished using the throttle screw on the gas valve. Figure 1 shows the location of the throttle screw on the Dungs GB-WND 055 valve. Figure 2 shows the location of the throttle screw on the Honeywell valve. Figure 3 shows the location of the throttle screw on the Dungs GB-WND 057 valve. Locate the throttle on the boiler being converted. 3) If conversion is being made on a new installation, install the boiler in accordance with the installation instructions supplied with the boiler. If an installed boiler is being converted, connect the new gas supply to the boiler, check for gas leaks, and purge the gas line up to the boiler in accordance with the National Fuel Gas Code (ANS Z223.1) or the requirements of the authority having jurisdiction. 4) Before attempting to start the boiler, make the number of turns to the throttle screw called for in the Table 2 below. When converting from Natural to LP gas, the screw is turned clockwise. When converting from LP to Natural Gas, the screw is turned counter-clockwise. 1

Figure 1a: Dungs HO Gas Valve Detail (BWC070, BWC090, BWC120, BWC151) Figure 1b: Dungs RH Gas Valve Detail (BWC150) Figure 2: Honeywell VK8115 Gas Valve Detail (BWC225) 2

Figure 3: Dungs GB-WND 057 Gas Valve Detail (BWC300, BWC399, BWC425) WARNING The pressure regulator has been factory set using precision instruments and must never be adjusted in the field. The gas valve outlet pressure is the same for both natural gas and propane. Make sure that all adjustments are made with the throttle, not the pressure regulator. Attempting to adjust the pressure regulator will result in damage to the gas valve and may cause property damage, personal injury or loss of life. WARNING The throttle adjustments shown in Table 2 are approximate. The final throttle setting must be found using a combustion analyzer. Leaving the boiler in operation with a CO level in excess of the value shown in Table 3 could result in injury or death from carbon monoxide poisoning. Boiler Model Gas Valve Table 2: Number of Throttle Turns Full Turns at Various Altitudes 0-2000ft 2000-5200ft 5200-7800ft 7800ft-10200ft BWC070 Dungs GB-WND 055 (HO) 2 3/4 2 3/4 2 3/4 2 3/4 BWC090 Dungs GB-WND 055 (HO) 2 3/4 2 3/4 2 3/4 2 3/4 BWC120 Dungs GB-WND 055 (HO) 4 4 1/2 4 1/2 BWC150 Dungs GB-WND 055 (RH) 4 1/4 5 5 BWC151 Dungs GB-WND 055 (HO) 4 4 4 BWC225 Honeywell VK8115 3 1/2 3 1/2 3 1/2 3 1/2 BWC300 Dungs GB-WND 057 2 1/2 2 1/2 2 1/2 2 1/2 BWC399 Dungs GB-WND 057 2 1/2 2 1/2 2 1/2 2 1/2 BWC425 Dungs GB-WND 057 2 1/2 2 1/2 2 1/2 2 1/2 3

IMPORTANT If the throttle is very far out of adjustment on the rich (counter-clockwise) side, the rules for adjusting the C will reverse: C will actually drop as the throttle is turned counterclockwise and increase as the throttle is turned clockwise. Under these conditions, the level will read 0% and the CO level will be extremely high (well over 1000PPM). If the boiler appears to be operating under these conditions, turn the throttle clockwise. If this is the problem, the C level will rise as the throttle is turned clockwise, eventually peaking at between 11% and 13% before falling. Once the C peaks, the CO level should start to fall. After this happens, continue turning the throttle clockwise until the C drops (or increases) to the level shown in Table 3. 5) Attempt to start the boiler using the lighting instructions located inside the lower front cover of the boiler. If the boiler does not light on the first try for ignition, allow to boiler to make at least four more attempts to light. If boiler still does not light, turn the throttle counter clockwise in 1/4 turn increments, allowing the boiler to make at least three tries for ignition at each setting, until the boiler lights. 6) After the burner lights, force the burner to high fire by simultaneously pressing and holding the Mode button and + button. After a few seconds, the display should flash H, indicating that the boiler has been driven to high fire. Allow the boiler to operate for approximately 5 minutes before taking combustion readings. Note: after 15 minutes, the boiler is automatically released from high fire hold. Be sure to restore high fire hold if additional time is needed to obtain high fire combustion readings. 7) Perform a combustion test. Boilers equipped with a concentric vent system have a flue gas sample tap located in the boiler vent collar (under the screw cap). For other vent systems, the sample probe may be inserted into the terminal. If this is not possible, remove the flue temperature sensor and insert the analyzer probe in the sensor opening. For the boiler to operate, this sensor will need to be remain connected to the wiring. If the flue gas sensor is removed, be sure to replace it after combustion testing is complete. 8) While the burner is at high fire adjust the throttle as needed to obtain the C (or ) settings shown in the Table 3: To reduce the C (increase the ) turn the throttle clockwise To increase the C (reduce the ) turn the throttle counter-clockwise Make adjustments in increments of 1/8 to 1/4 turn and allow the boiler at least a minute to respond to each adjustment before making another. In general, the CO level will be at its lowest somewhere in the C range shown in this table. Table 3a: Recommended Combustion Settings, Natural Gas Altitude Boiler Model 0-2000ft 5200-7800ft 7800ft-10200ft C Max CO C Max CO C Max CO (%) (%) PPM (%) (%) PPM (%) (%) PPM BWC070 9.4 4.4 75 9.4 4.4 75 9.0 5.1 75 BWC090 9.5 4.3 75 9.5 4.3 75 9.1 4.9 100 BWC120 9.5 4.3 75 9.5 4.3 75 8.8 5.4 100 BWC150 8.7 5.6 75 8.7 5.6 75 8.7 5.6 100 BWC151 9.5 4.3 75 9.5 4.3 75 9.0 5.1 100 BWC225 9.0 5.1 75 9.0 5.1 100 8.8 5.4 100 BWC300 9.0 5.1 75 9.0 5.1 75 8.8 5.4 100 BWC399 9.0 5.1 75 9.0 5.1 75 8.8 5.4 100 BWC425 9.0 5.1 75 9.0 5.1 75 8.8 5.4 100 4

Boiler Model Table 3b: Recommended Combustion Settings, LP Gas 9) Verify that the gas inlet pressure is between the upper and lower limits shown in Table 4 with all gas appliances (including the converted boiler) both on and off: Fuel Altitude 0-2000ft 5200-7800ft 7800ft-10200ft C Max CO C Max CO C Max CO (%) (%) PPM (%) (%) PPM (%) (%) PPM BWC070 10.4 5.1 75 10.4 5.1 75 10.2 5.4 100 BWC090 10.5 5.0 75 10.5 5.0 100 10.3 5.3 100 BWC120 10.5 5.0 75 10.5 5.0 100 BWC150 10.1 5.6 75 10.1 5.6 100 BWC151 10.5 5.0 75 10.5 5.0 100 BWC225 10.2 5.4 75 10.2 5.4 100 BWC300 10.2 5.4 75 9.9 5.8 100 9.9 5.8 100 BWC399 10.2 5.4 75 9.9 5.8 100 9.9 5.8 100 BWC425 10.2 5.4 75 9.9 5.8 100 9.9 5.8 100 Note: The CO2 and O2 values shown in Table 3 are at high fire and are +/-0.1%. Table 4: Inlet Pressure Limits Inlet Pressure (inches w.c.) Min. Max. Natural Gas 5.0 14.0 LP 11.0 13.0 10) Two sheets of labels are provided with this kit: one for conversions from natural to LP gas and one for conversions from LP to natural gas. Select the appropriate sheet of labels and apply them as follows: Apply the Rating Plate Label adjacent to the rating plate. Apply the Gas Valve Label to a conspicuous area on the gas valve. Apply the Boiler Conversion Label to a conspicuous surface on, or adjacent to, the outer boiler jacket. Fill in the date of the conversion and the name and address of the company making the conversion with a permanent marker. 11) Refer to the Start-up and Checkout section of the boiler installation manual and perform any checks not already completed. 5

Manufacturer of Hydronic Heating Products P.O. Box 14818 3633 I. Street Philadelphia, PA 19134 www.crownboiler.com PN: 980235 BWC - 01/12 Rev2