TECHNICAL DATA OBSOLETE

Similar documents
FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Wet pipe low flow foam/water system

OBSOLETE. Wet pipe low flow manifold system

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. Dry 132a. October 1, 2008

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Deluge Valves 211a. November 30, 2007 DELUGE VALVE MODEL E-1 ANGLE STYLE 3 (DN80), 4 (DN100) & 6 (DN150)

TECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Deluge Valves 218a. November 30, 2007 DELUGE VALVE MODEL F-1 STRAIGHT THROUGH STYLE 2-1/2 (DN65) - 8 (DN200)

TECHNICAL DATA. Q = C v P S

Anti-flood device Model B-1

TECHNICAL DATA CAUTION

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA ACCELERATOR MODEL E-1

Speed control assembly model A-1

TECHNICAL DATA CAUTION

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE

VERTICAL BLADDER TANK

HORIZONTAL BLADDER TANK

TECHNICAL DATA NOTICE

INSTALLATION OPERATION MAINTENANCE

Bladder Tank Installation & System Design Information

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

Preaction System with Model DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200)

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Preaction System with Model DV-5 Deluge Valve Single Interlock, Supervised Dry Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200)

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Horizontal Bladder Tanks

Vertical Bladder Tanks

TotalPac X Single interlock Preaction system Electric release

Bermad Model:

Model MTB-ASME Horizontal Bladder Tanks

Features. Model DDX-LP Dry Pipe Valve System 2 (50 mm), 2½ (65 mm), 3 (80 mm), 76 mm, 4 (100 mm), 6 (150 mm), 165 mm & 8 (200mm) Listings & Approvals

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Bermad Pressure Reducing. Model: 42T

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

FOAM TANK (1/2) DATA SHEET

Model MTB-ASME Vertical Bladder Tanks

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

Model MTB-ASME Vertical Bladder Tanks

FOAM TANK (1/2) DATA SHEET

Instructions for Installation, Operation, Care and Maintenance

Preaction System with Model DV-5 Deluge Valve Single Interlock, Supervised Electric Actuation 1-1/2 thru 8 Inch (DN40 thru DN200)

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Model: 43T. Bermad Pressure Relief Valve

a pilot sprinkler were to be closed after its initial operation, for example a remote manual control station).

BLADDER TANK PROPORTIONING SYSTEM PRE-PIPED

Data Sheet Issue A

FireLock NXT Preaction Valve with Series 798 Pneumatic/Pneumatic Actuator

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

Technical Data. UL Listing is based on the following criteria:

CONCENTRATE CONTROL SYSTEM

GENERAL DESCRIPTION MODEL RCW DRY SYSTEM CONFIGURATION. Technical Support Airpark Dr. Standish, MI 48658

VIKING OBSOLETE CONCENTRATE CONTROL SYSTEM OPERATING, MAINTENANCE, AND FILLING MANUAL. Vertical And Horizontal Bladder Tanks

BALANCED PRESSURE PROPORTIONERS

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Electric Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

FireLock NXT Dry Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

BERMAD Fire Protection Hydraulic Control Valves

MODEL RCW DRY SYSTEM VALVE

N2 BLAST Datasheet Preaction single interlock electric c/w N 2 Blast Nitrogen generating system Remote controlled unit

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

Irrigation System Winterization and Pressurization Procedures

ASTRA - DRY PIPE VALVES GROOVE/GROOVE

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

Transcription:

August 2, 2006 Foam 70a 1. DESCRIPTION A Hi-Expansion Foam System is a standard deluge system capable of discharging a foam/water solution automatically through open Hi-Ex Generators. A Hi-Expansion Foam System with a hydraulically actuated Halar coated Viking Deluge Concentrate Control Valve consists of a standard deluge system using a Viking Deluge Valve complete with full standard trim and detection and releasing devices on the water supply line, a concentrate controller- proportioning device with appropriately sized orifice, a hydraulically actuated Halar coated Viking Deluge Concentrate Control Valve on foam concentrate line, a foam concentrate bladder tank with trim and foam agent. 2. LISTINGS AND APPROVALS No formal approval as a system. Main component approvals listed below. Deluge Valve and Trim UL Listed - Guide VLFT FM - Automatic Water Control Valves Concentrate Controller (Proportioner) UL Listed - Guide GFGV FM Approved - Low Expansion Foam Systems Halar Coated Concentrate Control Valve (CCV) UL Listed - Guide VLFT FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate UL Listed - Guide GFGV FM Approved - Low Expansion Foam Systems Hi-Expansion Generators UL Listed - Guide GLHZ Viking Bladder Tank ASME Sect. VIII Certified UL Listed - Guide GHXV FM Approved - Low Expansion Foam Systems 3. Specifications: Refer to individual component technical data page Material Standards: Refer to individual component technical data page Ordering Information: Refer to Tables 1 through 5 4. INSTALLATION A. Discharge Devices Hi-Ex Generators Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikingcorp.com. The Web site may include a more recent edition of this Technical Data Page. B. General Instructions And Warnings 1. Refer to the Design Notes of the Design section of the foam water data book. 2. Refer to specific technical data sheets, acceptable installation standards, codes and Authority Having Jurisdiction for additional installation, operation and maintenance instructions. 3. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection and Maintenance. 4. WARNING - Any system maintenance or testing which involves placing a control valve or detection system out of service may eliminate the Fire Protection of that system. Prior to proceeding, notify all Authorities Having Jurisdiction. Consideration Form No. F_011205 Revised page replaces page Foam 70a-f dated April 29, 2005. (Reformatted page and updated drawing,)

Foam 70b August 2, 2006 should be given to employment of a Fire Patrol in the affected area. 5. The valve, trim and assembly must be installed in an area not subject to freezing temperatures or physical damage. C. Design & Installation WARNING: Locate all portions of the foam/water system subject to freezing, in a heated area. 1. Refer to the Special Notes on page 70g and the Warnings and General Notes on pages 50a-d in the Design Notes Section of the foam water data book. 2. Install the deluge valve (C) and trim in accordance with the Viking Engineering and Design Data Book. 3. Install the proportioning device (B), concentrate controller with integral orifice, in riser piping. 4. Install foam solution test valve (17) and system isolation valve (18). These valves are used to conduct foam/water solution tests. 5. Install hydraulically actuated Halar coated Viking Deluge foam concentrate control valve (D) and associated trim as indicated on Figure 70A, B, or C and trim charts or technical data pages. 6. Install bladder tank (A) in accordance with the manufacturer s instructions with connections as shown on Figure 70A, B, or C. a. Locate the tank as close as practical to the system riser. (See Special Note B on Page 70) b. Allow enough room around the tank to service the bladder. c. Allow access to the tank for filling from barrels of foam concentrate d. Install the pipe from the riser to the tank as indicated on Figure 70A, B, C or D. Install the piping from the tank (A) to the concentrate controller (B) as straight as possible. e. All valves and devices should be located for easy access for operation and maintenance. 7. Pressurize System a. Verify that water supply valve (10) is closed, then place bladder tank (A) in service by following manufacturer s instructions. b. Close tank water supply control valve (11), then place the deluge valve (C) in service as follows (See installation instructions on Viking Technical Data Sheet). c. Set release and detection system according to installation instructions for type of release used (Pneumatic, Hydraulic or Electric). d. Prime both Viking Deluge valves (C & D) by opening the priming valve on the deluge valve (C) trim. Bleed off any air pressure trapped in the priming line (13) to the Halar coated concentrate control valve (D) by opening the 3-way pressure gauge valve (14). Once air pressure has been relieved, close the 3-way valve and plug outlet. Re-open 3-way valve to maintain pressure on gauge (14). e. When pressure in deluge valve (C) priming chamber equals system water supply pressure, turn on system water supply by opening main drain on deluge valve (C) and partially opening water supply valve (10). When water appears at main drain, slowly close main drain. Before fully opening water supply control valve (10), place alarm test shut-off valve in alarm position, and open tank water supply control valve (11) and system isolation valve (18). With system set, fully open and secure water supply control valve (10). f. Verify normal valve positions and secure in proper position (See system components table). g. Check for and repair any leaks. D. REMOVING THE SYSTEM FROM SERVICE AND RETURNING THE SYSTEM TO SERVICE WARNING: See Warning under Item 7, Inspection and Maintenance 1. For system and riser piping maintenance and service. a. Close water supply control valve (10). b. Close concentrate shut-off valve (9***) and tank water supply valve (11). c. Open all drain valves on deluge system. d. Leave system isolation valve (18) open. e. Refer to instructions for removing the deluge valve (C) from service in the Viking Engineering and Design Data Book. f. Perform maintenance and service on system and riser piping. g. Open concentrate shut-off valve (9***). h. With tank water supply valve (11) closed, place the deluge valve (C) in service as follows (See installation instructions in Viking Engineering and Design Data Book. i. Set release and detection system according to installation instructions for type of release used (Pneumatic, Hydraulic or Electric). j. Prime both Viking Deluge valves (C & D) by opening the priming valve on the deluge valve (C) trim. Bleed off any air pressure trapped in the priming line to the concentrate control valve by opening the 3-way pressure gauge valve (14).

August 2, 2006 Foam 70c Once air pressure has been relieved, close the 3-way valve and plug the outlet. Re-open 3-way valve to maintain pressure on gauge (14). k. When pressure in deluge valve (C & D) priming chambers equal system water supply pressure, turn on system water supply by opening main drain on deluge valve (C) and partially opening water supply valve (10). When water appears at main drain, slowly close main drain. Before fully opening water supply valve (10), place alarm test shut-off valve in alarm position. Verify system isolation valve (18) is open and open tank water supply valve (11). With system set, fully open and secure water supply control valve (10). l. Verify normal valve positions and secure in proper position (See system components table). m. Check for and repair any leaks. 2. For tank maintenance and service - While leaving deluge system in service: a. Close concentrate shut-off valve (9***) and tank water supply (11). b. Follow tank manufacturer s procedures for removing from service, and perform maintenance. c. To return to service, close water supply control valve (10) and verify Halar coated foam concentrate control valve (D) is closed. Follow tank manufacturer s procedure. d. Verify that concentrate shut-off valve (9***), tank water supply (11) and system isolation valve (18) are open. Verify deluge valve (C) is primed, then open water supply control valve (10). e. Verify normal valve positions and secure in proper position (See system components table). f. Check for an repair any leaks. 3. For total system maintenance and service: a. Close water supply control valve (10), concentrate control shut-off valve (9***) and tank water supply valve (11). b. Open all drain valves on deluge system. c. Leave system isolation valve (18) open. d. Refer to instructions for removing the deluge valve (C) from service. See appropriate Viking Technical Data Sheet. e. Perform maintenance and service as required. f. Refer to the Special Notes on page 70g and the Warning and General Notes in the Design Notes section of the Foam Data Book. g. All valves should be closed, including concentrate control shut-off valve (9***), water supply control valve (10), tank water supply valve (11), foam solution test valve (17), system isolation valve (18) and Halar coated foam concentrate control valve (D), and alarm test shut-off valve on deluge valve (C) trim. h. Verify that water supply valve (10) is closed, then place bladder tank (A) in service by following manufacturer s instructions. i. Place the deluge valve (C) in service as follows (See installation instructions on Viking Technical Data Sheet) j. Set release and detection system according to installation instructions for type of release used (Pneumatic, Hydraulic or Electric) k. Prime both Viking Deluge valves (C & D) by opening the priming valve on the deluge valve (C) trim. Bleed off any air pressure trapped in the priming line (13) to the Halar coated concentrate control valve by opening the 3-way pressure gauge valve (14). Once air pressure has been relieved, close the 3-way valve and plug outlet. Re-open 3-way valve to maintain pressure on gauge (14). l. When pressure in deluge valve (C & D) priming chambers equal system water supply pressure, turn on system water supply by opening main drain on deluge valve (C) and partially opening water supply valve (10). When water appears at main drain, slowly close main drain. Before fully opening water supply control valve (10), place alarm test shut-off valve in alarm position, and open tank water supply control valve (11) and system isolation valve (18). With system set, fully open and secure water supply control valve (10). m. Verify normal valve positions and secure in proper position (See system components table). n. Check for and repair any leaks. E. Troubleshooting 1. For operating and maintenance instructions pertaining to Viking manufactured equipment, refer to the appropriate Viking Technical Data Sheet. 2. For operating and maintenance instructions pertaining to foam equipment manufactured for Viking, refer to the appropriate section of the Viking Foam Data Book. 3. For operation and maintenance instructions for all other equipment, refer to appropriate equipment data F. Emergency Instructions 1. During and after a fire: a. Make sure the fire is OUT! Make a complete inspection of all areas covered by this system including areas not involved

Foam 70d August 2, 2006 in the fire. Place a fire watch in the entire area until the system is back in service. b. Close the system water supply control valve (10). Post a person at the valve ready to turn it back on, should the fire rekindle. Close the tank water supply valve (11). c. Open the flow test angle valve, system drain valve and all auxiliary drain valves. Close drain valves once the system has completely drained. d. Replace any fused sprinklers in the pilot line (if so equipped), with the same type and temperature rating as were removed. Check all releases and/or detectors in the fire area for damage. e. Isolate the bladder tank (A) by closing the concentrate control shut-off valve (9***) and verify that the tank water supply control valve (11) is closed. f. Check the level of foam concentrate and refill the foam concentrate bladder tank (A) by following tank manufacturer s instructions. Always replace the foam concentrate with the same brand and type as that being used currently. Note: Never intermix different types or brands of foam concentrate, as this could cause them to gel or solidify, and render the concentrate useless. g. Return the complete system to service by following the procedure listed in Section 6C, Steps 6 through 14. h. Perform quarterly test. NOTE: If replacement foam concentrate is not immediately available, activate the deluge system portion of the foam/water system until the replacement concentrate arrives. 2. For emergency shut down of the complete system: a. Close main water supply valve (10). b. Close concentrate control shut-off valve (9***) to eliminate the flowing of the foam concentrate to the hydraulically actuated Halar coated Viking Deluge concentrate control valve (D) and the concentrate controller (B). c. Close tank water supply control valve (11) to reduce the pressure on the bladder tank (A). d. Open main drain. e. Completely drain system. f. Repair the damaged portion of the discharge system, or perform emergency maintenance as required. g. Return the riser and foam system to service by following the procedure listed in Section 6C, Steps 4 and 6 through 14. 3. If the foam concentrate pipe system is damaged: a. Close the concentrate control shut-off valve (9***) to eliminate the flowing of the foam concentrate to the hydraulically actuated Viking deluge foam concentrate control valve (D) and the concentrate controller (B). b. Close the tank water supply control valve (11) to reduce the pressure on the bladder tank (A). c. Verify that the Halar coated foam deluge concentrate control valve (D) is closed by observing water pressure gauge (14). If the water pressure gauge reads the same or higher than the system water pressure gauge located on the Viking deluge valve (C), the foam deluge concentrate control valve (D) is closed. d. Repair the damaged portion of the foam concentrate piping system. e. Return the foam concentrate system to service, by following the procedure as described above in Section 6B, items 3 through 6. NOTE: If there are no damaged sections of the distribution system, the deluge portion of the system may be kept in service for protection, while repairs to the foam concentrate system are performed. 5. OPERATION Actuation of the release line (pneumatic, hydraulic or electric) relieves the pressure in the priming chamber of both the Viking deluge valve (C) and the Halar coated Viking deluge concentrate control valve (D). This allows the clapper to open on both valves (C) and (D). The system piping is filled with water, activating connected alarms and pressurizing the bladder tank (A) by the water supply piping (12). System water pressure in the space between the flexible bladder and the inside surface of the steel tank, causes the bladder to collapse, forcing the foam concentrate out through the foam concentrate discharge piping (15), Halar coated concentrate control valve (D), and the metering orifice of the concentrate controller (B), into the venturi, (low pressure) area of the concentrate controller (B). The foam concentrate is proportioned (usually 2%), with the main water supply, sending foam solution to the Hi-Ex Generators downstream. 6. INSPECTIONS, TESTS AND MAINTENANCE NOTICE: The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to recognized standards such as those produced by NFPA, LPC and VdS which describe care and maintenance of sprinkler systems. In addition, the Authority Having Jurisdiction may have additional maintenance, testing and inspection requirements which must be followed.

August 2, 2006 Foam 70e WARNING - Any system maintenance or testing which involves placing a control valve or detection system out of service may eliminate the Fire Protection of that system. Prior to proceeding, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a Fire Patrol in the affected area. INSPECTIONS - It is imperative that the system be inspected and tested on a regular basis. The following recommendations are minimum requirements. The frequency of the inspections may vary due to contaminated or corrosive water supplies and corrosive atmospheres. In addition, the alarm devices or other connected equipment may require more frequent inspections. Refer to the technical data, system description, applicable codes and Authority Having Jurisdiction for minimum requirements. Prior to testing the equipment, notify appropriate personnel. A. Alarm Test - At least quarterly, test all connected alarm devices by opening the remote inspectors test valve. B. Riser Flow Test - At least quarterly, perform a riser flow test. Observe and record the supply pressure gauge reading. Open the main drain valve fully. Again, observe and record the supply pressure gauge reading. Close the main drain valve. If the readings vary significantly from those previously established or from normal, check the main supply line for obstructions or closed valves and correct. C. General - Visually inspect the valve, trim, piping, alarm devices and connected equipment for physical damage, freezing, corrosion or other conditions that may inhibit the proper operation of the system. 7. AVAILABILITY The Hi-Expansion Foam System is available through a network of domestic and international distributors. See the Viking Corp. web site for closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly. A B C SPECIAL NOTES Provide a minimum of 5 pipe diameters of straight pipe on the inlet and outlet of the concentrate controller (B) to minimize turbulence inside the concentrate controller. Exception, the outlet for the tank water supply control valve (11) maybe connected nearer to the inlet of the concentrate controller and should not cause excessive turbulence. However, if the outlet for the foam solution test valve (17) is located closer than 5 pipe diameters, there may be turbulence at high flow rates. The combined total equivalent length of pipe, fittings and valves in both the water supply inlet piping (12) and the foam concentrate discharge piping (15), must not exceed 50 equivalent feet (15.2 meters). This will allow both pipes to be the same size as the foam liquid inlet to the concentrate controller. Should the total equivalent length exceed 50 feet (15.2 meters), then refer to the Proportioning Device Design Data located in the Design section of this Data book for the method of calculating these pipe sizes. The Halar coated deluge concentrate control valve (D) and swing check valve (16) must be connected adjacent to the concentrate controller using pipe nipples as short as possible. D E F G Figure 70A, B or C is a general schematic of the required piping arrangement. Refer to the appropriate technical data page for specific information regarding the valve, tank and related trim and devices. The technical information, statements and recommendations contained in this manual are based on information and tests which, to the best of our knowledge, we believe to be dependable. It represents general guidelines only, and the accuracy or completeness thereof, are not guaranteed since conditions of handling and usage are outside our control. The purchaser should determine the suitability of the product for its intended use and assumes all risks and liability whatsoever in connection therewith. The Halar coated foam concentrate control deluge CCV (D) does not require any trim except for a ½ priming line (13) and water pressure gauge and 3-way valve (14) from the main deluge valve (C) to the priming chamber of valve (D). Plug all the remaining valve trim outlets. Connect concentrate control valve (D) priming line (13) to deluge valve (C) as shown on Figure 70. Refer to the Equipment section of this data book under Valves, to find the correct trim kit part number for the corresponding size of Halar coated foam concentrate control deluge valve (D) required. A strainer is not required in the foam concentrate discharge piping (15) of bladder tank systems per NFPA Standards.

Foam 70f August 2, 2006 FIGURE 70A

August 2, 2006 Foam 70g FIGURE 70B

Foam 70h August 2, 2006 FIGURE 70C

August 2, 2006 Foam 70i For a Hi-Expansion Deluge Foam/Water System, select deluge valve, conventional trim and release trim, Foam Concentrate Control Valve and Trim, Foam Concentrate, Controller, Bladder Tank, Hi-Ex Generator and accessories. Click on part number listed for technical data page. If there is no hyperlinked part number, there is either no data page available or the parts are provided by Viking SupplyNet (http://www.supplynet.com) DESCRIPTION NOMINAL PART DESCRIPTION NOMINAL PART SIZE NUMBER SIZE NUMBER 2% SYSTEMS PORTABLE & FIXED 2% HI-EXPANSION HI-EXPANSION FOAM CONCENTRATE GENERATORS 55 gallon drum F02416/55 Portable 4000 CFM F02410 Fixed 4000 CFM F02411 5 gallon containers available upon request POA. Fixed 7500 CFM F02412 Fixed 16000 CFM F02413 Fixed 22000 CFM F02414 2% HI-EXPANSION Fixed 28500 CFM F02415 CONCENTRATE CONTROLLERS 30-180 GPM (113,5-681,3 LPM) 2 / DN50 F02417 70-550 GPM (164,9-2081,7 LPM) 3 / DN80 F02418 60-1579 GPM (227-5976,5 LPM) 4 / DN100 F02419 150-2858 GPM (597,7-10817,53 LPM) 6 / DN150 F02420 Table 1 Form No. F_011205 Revised page replaces page Foam 70a-f dated April 29, 2005. (Reformatted page and updated drawing,)

Foam 70j August 2, 2006 For a Hi-Expansion Deluge Foam/Water System, select deluge valve, conventional trim and release trim, Foam Concentrate Control Valve and Trim, Foam Concentrate, Controller, Bladder Tank, Hi-Ex Generator and accessories. Click on part number listed for technical data page. If there is no hyperlinked part number, there is either no data page available or the parts are provided by Viking SupplyNet (http://www.supplynet.com) DESCRIPTION NOMINAL PART DESCRIPTION NOMINAL PART SIZE NUMBER SIZE NUMBER DELUGE VALVE Flange/Flange Painted Red Model E-2 / E-4 deluge valve is HALAR Flange Drilling Model F-1 coated and is protected against corrosion ANSI 3 12014 for mildly corrosive environments and ANSI 4 11953 conditions such as chemical plants or Rated to 250 psi (1 724 kpa) ANSI 6 11955 installations using sea water. Model E-1 / E-3 ANSI 8 11991 is the standard deluge valve painted red. ANSI/Japan 6 11964 PN10/16 DN80 12026 Angle Style PN10/16 DN100 11965 PN10/16 DN150 11956 Threaded NPT Painted Red PN10 DN200 11995 Model & Pipe O.D. PN16 DN200 11999 Model E-3 48mm 1½ / DN40 09889 HALAR Model E-1 60mm 2 / DN50 05852C Flange Drilling Model F-2 HALAR ANSI 3 12015Q/B Model E-4 48mm 1½ / DN40 09890Q/B ANSI 4 11960Q/B Model E-2 60mm 2 / DN50 08361Q/B ANSI 6 11962Q/B ANSI 8 11992Q/B Flange/Flange Painted Red PN10/16 DN80 12027Q/B Flange Drilling Model E-1 PN10/16 DN100 11966Q/B ANSI 3 05912C PN10/16 DN150 11963Q/B ANSI 4 05909C PN10 DN200 11996Q/B ANSI 6 05906C PN16 DN200 12000Q/B ANSI/Japan 6 07136 PN10/16 DN80 08626 PN10/16 DN100 08629 Flange/Groove Painted Red PN10/16 DN150 08631 HALAR Flange Drilling / Pipe O.D. Model F-1 Flange Drilling Model E-2 ANSI / 89mm 3 12018 ANSI 3 08362Q/B ANSI / 114mm 4 11952 ANSI 4 08363Q/B ANSI / 168mm 6 11954 ANSI 6 08364Q/B PN10/16 / 89mm DN80 12030 PN10/16 DN80 08862Q/B PN10/16 / 114mm DN100 11958 PN10/16 DN100 08863Q/B PN10/16 / 165mm DN150 12640 PN10/16 DN150 08864Q/B PN10/16 / 168mm DN150 11954 HALAR Flange/Groove Painted Red Flange Drilling / Pipe O.D. Model F-2 Flange Drilling / Pipe O.D. Model E-1 ANSI / 89mm 3 12019Q/B ANSI / 89mm 3 05835C ANSI / 114mm 4 11959Q/B ANSI / 114mm 4 05839C ANSI / 168mm 6 11961Q/B ANSI / 168mm 6 05456C PN10/16 / 89mm DN80 12644Q/B PN10/16 / 89mm DN80 09539 PN10/16 / 114mm DN100 12645Q/B PN10/16 / 114mm DN100 09540 PN10/16 / 165mm DN150 12641Q/B PN10/16 / 168mm DN150 05456C PN10/16 / 168mm DN150 11961Q/B HALAR Flange Drilling / Pipe O.D. Model E-2 Groove/Groove Painted Red ANSI / 89mm 3 11064Q/B Pipe O.D. Model F-1 ANSI / 114mm 4 11065Q/B 48mm 1½ / DN40 12125 ANSI / 168mm 6 11001Q/B 60mm 2 / DN50 12057 PN10/16 / 168mm DN150 11001Q/B 73mm 2½ / DN65 12403 76mm DN80 12729 Straight Through 89mm 3 / DN80 12022 114mm 4 / DN100 11513 Threaded Painted Red 165mm DN150 11910 Pipe O.D. Model F-1 168mm 6 / DN150 11524 NPT 48mm 1½ 12126 219mm 8 / DN200 11018 NPT 60mm 2 12059 HALAR NPT 65mm 2½ 12401 Pipe O.D. Model F-2 BSP 48mm DN40 12682 48mm 1½ / DN40 12127Q/B BSP 60mm DN50 12686 60mm 2 / DN50 12058Q/B HALAR Model F-2 73mm 2½ / DN65 12404Q/B NPT 65mm 2½ 12402Q/B 76mm DN80 12730Q/B 89mm 3 / DN80 12023Q/B 114mm 4 / DN100 11514Q/B 165mm DN150 11911Q/B 168mm 6 / DN150 11525Q/B 219mm 8 / DN200 11118Q/B Table 2

August 2, 2006 Foam 70k For a Hi-Expansion Deluge Foam/Water System, select deluge valve, conventional trim and release trim, Foam Concentrate Control Valve and Trim, Foam Concentrate, Controller, Bladder Tank, Hi-Ex Generator and accessories. Click on part number listed for technical data page. If there is no hyperlinked part number, there is either no data page available or the parts are provided by Viking SupplyNet (http://www.supplynet.com) DESCRIPTION NOMINAL PART DESCRIPTION NOMINAL PART SIZE NUMBER SIZE NUMBER CONVENTIONAL Rated to 250 psi (1 724 kpa) CONVENTIONAL DELUGE Use with Angle Style and DELUGE VALVE TRIM VALVE ACCESSORY PKG Straight Through Valves Includes Deluge Valve Use with Angle Style Valves Includes: Accessory Package Galvanized - 1/16 Restricted Orifice 1½ / DN40 10202 - Emergency Release Galvanized Deluge trim available 2 / DN50 10203 - Drip Check pre-assembled* in sections for 3 / DN80 10204 - ¼ / 8mm Check Valve additional cost of $180.00 list. 4 / DN100 10205 - ¼ / 8mm Strainer Galvanized 09316 Add suffix P to Part No. to 6 / DN150 10206 - Drain Cup denote preassembled. - PORV Brass 09743 Brass - Drain Check 1½ / DN40 10250 - ½ Ball Valve 2 / DN50 10251 3 / DN80 10252 4 / DN100 10253 TRIMPAC Use with Angle Style and Straight 6 / DN150 10254 Includes: Through for Conventional Trim - Conventional Trim Use with Straight Through Valves - Release Trim Galvanized - Flexible Hose Kit Hoz. 1½ / DN40 12410-1 Must order drain pkg (below) separately 2 / DN50 12410-1 Galvanized 2½ / DN65 12299-1 Single Interlock 3 / DN80 12299-1 Electric Release 12233B-3 4 / DN100 11938-1 Pneumatic Release 12234B-4 6 / DN150 11939-1 Double Interlock 8 / DN200 11072 Electric/Pneumatic Release 12235B-5 Vert. 1½ / DN40 12409-1 Electric/Pneu-lectric Release 12237B-6 2 / DN50 12409-1 Deluge 2½ / DN65 12298-1 Electric Release 12228B-1 3 / DN80 12298-1 Pneumatic Release 12229B-2 4 / DN100 11712-1 6 / DN150 11714-1 8 / DN200 11077 Drain Package Use with TrimPac (above) 1½ / DN40 11894-1 V25.4B Brass 2 / DN50 11894-2 Hoz. 1½ / DN40 12410-2 2½ / DN65 11894-3 2 / DN50 12410-2 3 / DN80 11894-3 2½ / DN65 12299-2 4 / DN100 11894-4 3 / DN80 12299-2 6 / DN150 11894-4 4 / DN100 11938-2 8 / DN200 11894-4 6 / DN150 11939-2 8 / DN200 11164 Replacement Hose Vert. 1½ / DN40 12409-2 Flexible Braided Hose 5 Length 11895 2 / DN50 12409-2 Stainless Steel/Teflon 2½ / DN65 12298-2 PVC Drain Hose 12071 3 / DN80 12298-2 4 / DN100 11712-2 6 / DN150 11714-2 Riser Mounting Kit Vertical 11900 8 / DN200 11165 - Use with TrimPac (above) Horizontal 11901 - Use when mounting to riser *Trim dimensions shown on technical data pages are based on loose trim. If pre-assembled trim is ordered, please allow for 6 maximum additional spacing. Pre-assembled trim is wrench tight. Table 3

Foam 70l August 2, 2006 For a Hi-Expansion Deluge Foam/Water System, select deluge valve, conventional trim and release trim, Foam Concentrate Control Valve and Trim, Foam Concentrate, Controller, Bladder Tank, Hi-Ex Generator and accessories. Click on part number listed for technical data page. If there is no hyperlinked part number, there is either no data page available or the parts are provided by Viking SupplyNet (http://www.supplynet.com) DESCRIPTION NOMINAL PART DESCRIPTION NOMINAL PART SIZE NUMBER SIZE NUMBER ACCESSORIES FOR FOAM/WATER SPRINKLER SYSTEMS Use with Angle Style Valve Bladder Tank Water Supply FOAM CONCENTRATE Galvanized Control Valve CONTROL VALVE TRIM 1½ / DN40 08098 Foam Concentrate Swing Check Valve Foam Solution Test Valve System Isolation Valve Ball Valve 1½ / DN40 WBV-0150 2 / DN50 08099 Ball Valve 2 / DN50 WBV-0200 OS & Y 2½ / DN65 8068A-0250 Brass OS & Y 3 / DN80 8068A-0300 1½ / DN40 09694 2 / DN50 09695 Use with Straight Through 1½ / DN40 99S-0150 Galvanized 2 / DN50 99S-0200 1½ / DN40 12848-1 2½ / DN65 05497C 2 / DN50 12848-1 2½ / DN65 12929-1 2½ / DN65 01G-0250 Brass Grooved Butterfly Valve Grooved Butterfly Valve 3 / DN80 01G-0300 1½ / DN40 12848-2 Grooved Butterfly Valve 4 / DN100 01G-0400 2 / DN50 12848-2 Grooved Butterfly Valve 6 / DN150 01G-0600 2½ / DN65 12929-2 Grooved Butterfly Valve 8 / DN200 01G-0800 RELEASE TRIM PACKAGES Grooved Butterfly Valve 2½ / DN65 01G-0250 Valves Use with Conventional Trim Use with Angle Style Grooved Butterfly Valve 3 / DN80 01G-0300 Galvanized Grooved Butterfly Valve 4 / DN100 01G-0400 Pneumatic 09069 Grooved Butterfly Valve 6 / DN150 01G-0600 Electric/Pneumatic 09314 Grooved Butterfly Valve 8 / DN200 01G-0800 Electric 09070 Pneumatic/Pneumatic 10372 Brass Water Supply Control Valve Pneumatic 09717 Electric/Pneumatic 09714 OS & Y 2½ / DN65 8068A-0250 OS & Y 3 / DN80 8068A-0300 Electric 09698 OS & Y 4 / DN100 8068A-0400 Pneumatic/Pneumatic 11187 OS & Y 6 / DN150 8068A-0600 OS & Y 8 / DN200 8068A-0800 Valves Use with Conventional Trim Use with Straight Through Galvanized Foam Concentrate Shut-Off Valve Pneumatic 10809 Ball Valve 1½ / DN40 T595Y66-0150 Electric/Pneumatic 12661-1 Ball Valve 2 / DN50 T595Y66-0200 Electric 10830 Valves Pneumatic/Pneumatic 12662-1 Brass FOAM CONCENTRATE This valve is HALAR coated for Pneumatic 10811 CONTROL VALVE protection in corrosive environments Electric/Pneumatic 12661-2 Model E-2/E-4 Deluge Valve and can be used with ARC Electric 10832 Model F-2 Deluge Valve or AFFF foam concentrates. Pneumatic/Pneumatic 12662-2 Angle Style NOTE: Solenoid valve and/or pneumatic actuator must be ordered separately. Threaded NPT (Pneumatic/pneumatic trims include pneumatic actuator.) HALAR Model & Pipe O.D. Model E-4 48mm 1½ / DN40 09890Q/B Model E-2 60mm 2 / DN50 08361Q/B Straight Through Threaded NPT HALAR Pipe O.D. Model F-2 NPT 65mm 2½ 12402Q/B Groove/Groove HALAR Pipe O.D. Model F-2 48mm 1½ / DN40 12127Q/B 60mm 2 / DN50 12058Q/B 73mm 2½ / DN65 12404Q/B Table 4

August 2, 2006 Foam 70m For a Hi-Expansion Deluge Foam/Water System, select deluge valve, conventional trim and release trim, Foam Concentrate Control Valve and Trim, Foam Concentrate, Controller, Bladder Tank, Hi-Ex Generator and accessories. Click on part number listed for technical data page. If there is no hyperlinked part number, there is either no data page available or the parts are provided by Viking SupplyNet (http://www.supplynet.com) DESCRIPTION MODEL PART DESCRIPTION MODEL PART NUMBER NUMBER VERTICAL HORIZONTAL Volume BLADDER TANK BLADDER TANK (gal/ltrs) Horizontal Tank 100 / 379 VB100H 150 / 568 VB150H 200 / 757 VB200H 300 / 1136 VB300H Vertical Tank Volume Includes: 400 / 1514 VB400H Includes: (gal/ltrs) - Water Drain / Fill Valve 500 / 1893 VB500H - Water Drain / Fill Valve - Fill Line Master Shut-Off Valve 600 / 2271 VB600H - Fill Line Master Shut-Off Valve 36 / 136 VB36V - Concentrate Drain / Fill Valve 700 / 2650 VB700H - Concentrate Drain / Fill Valve 50 / 189 VB50V - Fill Cup / Sight Gauge - Fill Cup / Sight Gauge 75 / 284 VB75V Shut-Off Valve 800 / 3028 VB800H Shut-Off Valve 100 / 379 VB100V - Sight Gauge Assembly 900 / 3407 VB900H - Sight Gauge Assembly 150 / 568 VB150V - Tank Water Vent Valve 1000 / 3785 VB1000H - Tank Water Vent Valve - Diaphragm Concentrate 1100 / 4164 VB1100H - Diaphragm Concentrate 200 / 757 VB200V Vent Valve Vent Valve 250 / 946 VB250V 1200 / 4542 VB1200H 300 / 1136 VB300V 1300 / 4921 VB1300H 400 / 1514 VB400V 1400 / 5299 VB1400H 500 / 1893 VB500V 1500 / 5678 VB1500H 600 / 2271 VB600V 1600 / 6056 VB1600H 700 / 2650 VB700V 1700 / 6435 VB1700H 750 / 2839 VB750V 1800 / 6813 VB1800H 800 / 3028 VB800V 1900 / 7192 VB1900H 900 / 3407 VB900V 2000 / 7570 VB2000H 1000 / 3785 VB1000V 2100 / 7949 VB2100H 1100 / 4164 VB1100V 2200 / 8327 VB2200H 1200 / 4542 VB1200V 2300 / 8706 VB2300H 1300 / 4921 VB1300V 2400 / 9084 VB2400H 1400 / 5299 VB1400V 2500 / 9463 VB2500H 1500 / 5678 VB1500V 2600 / 9841 VB2600H 1600 / 6056 VB1600V 2700 / 10220 VB2700H 1700 / 6435 VB1700V 2800 / 10598 VB2800H 1800 / 6813 VB1800V 2900 / 10977 VB2900H 1900 / 7192 VB1900V 3000 / 11355 VB3000H 2000 / 7570 VB2000V 3100 / 11734 VB3100H 2100 / 7949 VB2100V 3200 / 12112 VB3200H 2200 / 8327 VB2200V 3300 / 12491 VB3300H 2300 / 8706 VB2300V 3400 / 12869 VB3400H 2400 / 9084 VB2400V 3500 / 13248 VB3500H 3600 / 13626 VB3600H 3700 / 14005 VB3700H Foam System Start-Up Service available. 3800 / 14383 VB3800H 3900 / 14762 VB3900H 4000 / 15140 VB4000H Table 5

THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_011205 Revised page replaces page Foam 70a-f dated April 29, 2005. (Reformatted page and updated drawing,)