GLAST Large Area Telescope: TEM/TPS TRR

Similar documents
SLAC (650) DAQ & FSW

GLAST Large Area Telescope:

GLAST Large Area Telescope:

GLAST Large Area Telescope:

GLAST Large Area Telescope:

GLAST Large Area Telescope: W.B.S Electronics, Data Acquisition & Flight Software. Gamma-ray Large Area Space Telescope

Integrated Space Systems

GLAST Large Area Telescope Monthly Mission Review

GLAST Large Area Telescope: I & T Input to Monthly Technical/Cost/Schedule Review 09/27/05

Proton Monitor Thermal Vacuum Test Procedure GP-B P0635

Coda cx1 Thermal Cycle Test Procedure

Monthly Mission Review. TVAC at NRL? Status. July 12, Neil Johnson NRL Gamma-ray Large Area Space Telescope

Process. Summary results. RFA Status

IEP SENSOR BRACKET CHECKOUT AND VERIFICATION. This is a non-hazardous test.

LOW PRESSURE VOLTAGE BREAKDOWN TEST PROCEDURE FOR GSS FSU FLIGHT SPARE HVA BOARD October 28, P0938 Rev

DESIGN VERIFICATION AND QUALIFICATION OF NEW POPPET AND BUSHING ON GMA FLIGHT SOLENOID VALVES

GLAST Large Area Telescope

Monthly Mission Review. Project Status Overview. June 6, Ken Fouts SLAC Gamma-ray Large Area Space Telescope

Application Note AN-107

MIL-STD-883G METHOD

Proto-qual Vibration Test Procedure 2.5 and 6 Vacuum Valves (3179 and 3223) Retest of Flight Spare Valves. GP-B P0735 Rev.-

Monthly Mission Review. Project Status Overview. July 12, Neil Johnson NRL Gamma-ray Large Area Space Telescope

Qualification of Fastrak & First Gen Product to Railway applications Shock and Vibration Standard EN 61373

GMA FUNCTIONAL TEST SETTING & TESTING OF SPIN UP PARAMETERS. P0586 REV -- 20, June 2000 GPB SCIENCE MISSION PROCEDURE

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Pressure Sensor Bridge Configurations

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

CONTROL TECHNOLOGY INC Middlebrook Pike, Knoxville, TN Phone FAX

Pneumatic high-pressure controller Model CPC7000

HumiSys HF High Flow RH Generator

ASDX Series Silicon Pressure Sensors

GasSense NDIR User Manual

Testing of Active Flow Control actuators at harsh environment

Product Overview. Product Description CHAPTER

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

UNDERSTANDING, ACCELERATED

PEAPOD. Pneumatically Energized Auto-throttled Pump Operated for a Developmental Upperstage. Test Readiness Review

Protocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO. Quality Assurance Plan/Standard Operating Procedure

THE CANDU 9 DISTRffiUTED CONTROL SYSTEM DESIGN PROCESS

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

RPS900W Redundant Power Supply. Installation Guide.

Quadruple mass spectrometers (transducer type)

PRODUCT SPECIFICATION. SFP+ Cage and Cage Assembly 1 of 8 A

Mass Flowmeters. Mass Flowmeters for Gases

Programmable pressure and temperature transmitters PTM/RS485

Supplementary Certificate of Approval. No S433

HASTAC High stability Altimeter SysTem for Air data Computers

UltraLo 1800 Alpha Particle Counter

Supplementary Operator s Manual 42/24-14 EN Rev. 3

SonoMeter 30 Energy Meters

CRaTER Thermal-Vacuum Test Procedure. Dwg. No

Electronic gas volume corrector model DGVC-04

Mass Flow Controller (MFC) for Gases

Gamma-ray Large Area Space Telescope

CALIBRATING THE GMA PRESSURE SENSORS AND THE ECU ENGINEERING UNIT

Pneumatic high-pressure controller Model CPC7000

Design Features. General Description

Programmable pressure and temperature transmitters PTM/RS485

FTC130 Transmitter. Operating Manual

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

How to specify a product. Process Sensors and Mechanical Instruments

Additel 780 Series Pressure Controller

Vibration/leak Test 2.5 and 6 Vatterfly Valves (3179 and 3223) spare units. GP-B Engineering Procedure P0761 Rev.-

Technical Review Agenda

3. Real-time operation and review of complex circuits, allowing the weighing of alternative design actions.

This test shall be carried out on all vehicles equipped with open type traction batteries.

LEVIFLOW INTEGRATED FLOWMETER LFIF USER MANUAL

Safety Manual VEGAVIB series 60

STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Programmable Submersible Level Transmitters

A i r c r a f t E l e c t r i c a l S y s t e m s ( 1 2 B )

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Mass Flow Controller (MFC) for Gases

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Yokogawa Systems and PCI Training

628 Differential Pressure Decay Leak Tester

Additel 780 Series Pressure Controller

Gas density monitor With integrated transmitter Model GDM-100-TI

Commissioning and safety manual

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Parametrable / Programmable Pressure Transmitter

Service & Support. Questions and Answers about the Proof Test Interval. Proof Test According to IEC FAQ August Answers for industry.

User Manual. Quantos Automated Dosing Liquid Module

82C288 BUS CONTROLLER FOR PROCESSORS (82C C C288-8)

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

TEST OF GMA SPINUP ASSEMBLY PRESSURE SENSOR CALIBRATION

POROUS PLUG CHARACTERIZATION TEST

AMS 6915 Board mount pressure sensor with digital output (I²C)

INSTRUCTION MANUAL. Lesker Model KJL615TC-K Lesker Model KJL615TC-H. Digital Vacuum Gauge/Controller. KJL615TC K/H Ranges

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

DCS Series 1 kw, 1.2 kw, & 3 kw

Flight Software Overview

ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN

Improve Process Reliability

THERMAL MASS FLOW MEASUREMENT FOR GASES

Transcription:

Gamma-ray Large Area Space Telescope GLAST Large Area Telescope: TEM/TPS TRR Presented by G. Haller SLAC haller@slac.stanford.edu (650) 926-4257 4.1.7 DAQ & FSW V3 1

Contents Introduction Overview Significant Changes since CDR Objectives Status Requirements/Verification EGSE and Test-Procedures Verification Test Plan and Flow At Assembly Vendor Test-plan and Flow Facility Man-Power Quality Assurance Vibration At SLAC Test-plan and Flow Thermal Vacuum Test Mass Property EMI/EMC (at sub-contractor) Man-Power Quality Assurance Equipment Calibration/Safety Risk Assessment Schedule Status of Procedures Issues and Concerns 4.1.7 DAQ & FSW V3 2

LAT Electronics TKR Front-End Electronics (MCM) ACD Front-End Electronics (FREE) CAL Front-End Electronics (AFEE) TKR Global-Trigger/ACD-EM/Signal-Distribution Unit* Spacecraft Interface Units (SIU)* Storage Interface Board (SIB): Spacecraft interface, control & telemetry LAT control CPU LAT Communication Board (LCB): LAT command and data interface CAL 16 Tower Electronics Modules & Tower Power Supplies 3 Event-Processor Units (EPU) (2 + 1 spare) Event processing CPU LAT Communication Board SIB Power-Distribution Unit (PDU)* Spacecraft interface, power LAT power distribution LAT health monitoring * Primary & Secondary Units shown in one chassis 4.1.7 DAQ & FSW V3 3

TEM/TPS Mounted to CAL TKR not shown LAT GRID with 16 CAL/TEM/TPS Modules CAL TEM TPS 4.1.7 DAQ & FSW V3 4

Tower Electronics Module Main DAQ module, one on each tower Controls and reads out data from TKR MCM and CAL AFEE front-end electronics Zero-suppresses CAL event data Buffers events in cable ASIC FIFO s Assembles CAL and TKR event fragments to tower event Transmits data to GASU Contains monitoring and low-rate science circuits LVDS interface to front-end electronics and GASU EM Tower Electronics Module (TEM) before coating/staking 6 3 4 5 3 4 29X 2 5 TEM Assembly 4 2 3 26X 3 1 2 1 4.1.7 DAQ & FSW V3 5

Tower Power Supply Tower Power Supply module, one on each tower Input 28V Generates low-noise voltages for TKR (2.65V analog, 2.65V Digital) CAL (3.3V analog, 3.3V digital) TEM (3.3V and 2.5V digital) TKR Bias (20V-140V programmable) CAL (20V to 90V programmable) Temperature sensors EM Tower Power Supply (TPS) before coating/staking 20X 3 6 8 8 3 2X 7 2 2X 2 3 5 12 5 16 2X 2 13 J1 4 26X 2 3 4 26X 2 6 TPS Assembly 2 3 6 4X 5 3 4X 4 J2 1 1 8 2X 3 7 4.1.7 DAQ & FSW V3 6

TEM/TPS Assembly After TEM and TPS are tested individually, the two modules are mated and the TEM/TPS package is tested TPS 3 1 2 40X TEM 1 2 Shown upside-down TPS 1 1 TEM 4.1.7 DAQ & FSW V3 7

Changes since TEM CDR and Power-Supply Delta CDR Power Supply Review from 9-22-03 SLAC GLAST web-site -> Electronics & DAQ -> Reviews TEM Modification of FPGA code To fix a couple of bugs To change flow-control slightly to optimize dataflow throughout system Code was reviewed by GSFC reviewer (Dr Rod) Some resistor/capacitor values have changed to optimize monitoring ranges Details of monitoring circuit have changed and a sub-set of current monitoring functions were eliminated TPS Resistor/capacitor changes to optimize circuit performance over temperature Changes in poly-switch values to protect better over temperature (instead of RXE185, split the load into two paths with a RXE110 each), increased the current sensing resistor from a 1W to a 3W resistor. Changed resistor values to Modify TKR 2.5V to 2.65V Decrease maximum CAL Bias from 120V to 90V Changed Zener diodes at Bias output voltage for new max values Changed resistor values to optimize in-rush current level Worst Case Analysis updated to incorporate changes Thermal Analysis from CDR/Delta-CDR remained since changes don t impact thermal performance 4.1.7 DAQ & FSW V3 8

Objectives Demonstrate that hardware, software, procedures, and support equipment are prepared to support system environmental test Demonstrate that planned and completed testing meets performance and interface requirements Identify and understand all the risks and limitations TRR is not intended to Review TEM/TPS design Review flight readiness Buy-off hardware or software RFA s should only be of sufficient concern to stop test Prior to start of an given test, any applicable TRR RFAs must be closed 4.1.7 DAQ & FSW V3 9

Test Entrance / Exit Criteria Entrance All required paperwork released and in place Procedures, drawings, etc Test configuration verified and approved Essential personnel in place Pre-test TEM/TPS functional successfully passed Exit As-run procedures completed Correct and accurate application of test environment Test data acquired and archived No damage to TPS/TEM TEM/TPS performance within specification limits Post-test TEM/TPS functional successful 4.1.7 DAQ & FSW V3 10

Status 3 TEM/TPS Qualification unit, Tower A, and Tower B units Assembled, Functional tested Ready for environmental test Assembly of balance of 19 TEM and TPS authorized to proceed, but not started yet All parts at assembler 4.1.7 DAQ & FSW V3 11

Tests To-Date TEM and TPS engineering modules were extensively tested As EGSE in DAQ/CAL/TKR/I&T >50 test-stands were tested with SLAC TPS and TEM Test Procedure TEM and TPS were used to test functionality and performance of TKR and CAL sub-system electronics Met requirements by sub-system CAL performed vibration tests on coated/staked TEM/TPS to CAL levels, passed (exceptions were first modules in-house staked) Additional TEM/TPS tests Informal thermal-vacuum test -40C to 55C, passed CPT Vibration tests of staked TEM/TPS passed DAQ qual levels On test-bed 16 TEM/TPS connected to EM PDU and GASU and to Front-End Simulator modules generating trigger and event-data Run up to 10 KHz data-rates 4.1.7 DAQ & FSW V3 12

Tests To-date (con( con t) On fully-instrumented tower 36 TKR MCM s 4 CAL AFEE s Ran tests and passed Test results for TEM/TPS performance tests posted for the EGSE TEM/TPS E.g. TEM/TPS delivered to CAL: http://www-glast.slac.stanford.edu/elec_daq/egse/cal-afee/cal.htm IO tested to sub-system ICD s Configuration and data-taking tested Monitoring functions/performance tested Tested over Frequency (16Mhz to 22 MHz, 20 MHz nominal) Temperature (-40C to 55C) TEM supply range (3.3V +/- 10%, 2.5V +/-10%) One flight PCB TEM/TPS was loaded at SLAC with mostly parts from flight lots, including flight-lot ACTEL FPGA s Passed tests from -40C to 55C over voltage and frequency Three TEM and TPS flight modules assembled at flight-assembly vendor individually tested with CPT procedures, over temperature, passed tests 4.1.7 DAQ & FSW V3 13

Requirements LAT-SS-00019 Specifications, Level 3 T&DF Subsystem Specification LAT-SS-00284 Specifications, Level 4 Trigger LAT-SS-00285 Specifications, Level 4 Dataflow LAT-SS-00136 Specifications, Level 3 Power Supply System LAT-SS-00183 Specifications, Level 4 Power Supply System LAT-SS-05522 Specifications, Level 5 TEM Specification LAT-SS-01281 Specifications, Level 5 TPS ICD & Specification LAT-SS-05533 Specifications, Level 5 TEM/TPS Specification 4.1.7 DAQ & FSW V3 14

Derived Requirements LAT-SS-05533 TEM/TPS lists 132 requirements for TEM/TPS package (most are from TEM LAT-SS-05522 (108) with extensions (24) to include TPS requirements for the TEM/TPS package) Verification Matrix gives approach to verify each requirement LAT-TD-05536 Lists verification method used Assembly level at which requirement is verified All TEM requirements at TEM assembly level (LAT-SS- 05522) ALL TPS requirements at TPS assembly level (LAT-SS- 01281) TEM/TPS package requirements at TEM/TPS assembly level (LAT-SS-05533) 4.1.7 DAQ & FSW V3 15

System Performance Level 3 and level 4 DAQ and TRG and power-system requirements are met with a combination of DAQ modules (TEM/TPS, GASU, SIU, PDU, etc), since the DAQ and trigger and power system is comprised of several sub-system module types Level 5 TEM/TPS requirements which are verified are derived from Level 3 and Level 4 DAQ and Trigger and Power system specifications (as noted in the L5 requirements doc) Level 5 requirement doc includes derived requirement addressing Functionality/performance Power Mass/C.G. EMI/EMC Environmental incl temperature and vibration 4.1.7 DAQ & FSW V3 16

Verification Status Engineering Module TEM/TPS EM completed full environmental/functional test program with exception of EMI/EMC, mass, and C.G. Demonstrated compliance with specifications 4.1.7 DAQ & FSW V3 17

EGSE and Test-Procedures EGSE for Functional/Performance Tests Test-Stand documented in LAT-DS-04085 TEM (at TEM module level) TEM Stray-Voltage-Test Procedure LAT-TD-04097 TEM Electrical Interface Continuity and Isolation Test procedure LAT-TD-03831 TEM Test-Procedure LPT LAT-TD-03415 TPS (at TPS module level) TPS Stray-Voltage-Test Procedure LAT-TD-04098 TPS Electrical Interface Continuity and Isolation Test procedure LAT-TD-04099 TPS Test-Procedure LPT LAT-TD-01652 TEM/TPS (at combined unit level) TEM/TPS Performance Test Procedure LAT-TD-01485 4.1.7 DAQ & FSW V3 18

EGSE Test-Configuration LAT-DS-04085 TEM (Unit Under Test) 14 TEM connectors: 9-51 pin connectors (Trk, GASU) 4-69 pin connectors (Cal) 1 50 pin connector (TEM PS) JC0 JC1 JC2 JC3 JT0 JT1 JT2 JT3 JT4 JT5 JT6 JT7 J1 JS1 J2 JC0 JC3 Connector savers LAT-DS-04724 P2 P1 LAT-DS-04467 P2 P1 LAT-DS-04467 P2 P1 LAT-DS-04467 P2 P1 LAT-DS-04467 P2 P1 LAT-DS-04466 P2 P1 LAT-DS-04466 P2 P1 LAT-DS-04466 P2 P1 LAT-DS-04466 P2 P1 LAT-DS-04466 P2 P1 LAT-DS-04466 P2 P1 LAT-DS-04466 P2 P1 LAT-DS-04466 P2 JT0 JT7 Connector savers MWDM2L-51USP1 Tower Power Supply J1 TEM Test Board LAT-DS-04465 13 connectors: 8-51 pin connectors (TKR) 4-69 pin connectors (CAL) 1-2 pin connector (PWR In) P1 +X JC0 +Y JC1 -X JC2 -Y JC3 C0 JT0 C1 JT1 C2 JT2 C3 JT3 C4 JT4 C5 JT5 C6 JT6 C7 JT7 Connector saver DGBH26MF J1 Test Board Cooling Fan Assembly P3 LAT-DS-03246 P2/P2 DC Power (-) Supply #1 BK 1697 P1/P1 Set to 28 V (+) RS-232 Cable LAT-DS-03567 Pomona B-12-0 LAT-DS-02106 P1 P2 LAT-DS-03246 LAT-DS-04831 (+) DC Power Supply #2 BK1697 (-) Set to 3.3 V Function Generator P3 P2 NC P1 J1 J2 LAT-DS-03247 J3 EXT CLK 28 V GND PS CTRL EXT TRIG To TEM (GASU) To LCB EVENT To LCB CMD Slot 0 SBC MVME 2304 Card VME Slot 4 TST-STP Trans Card LAT-DS-00999 LCB Mezzanine Card LAT-TD-00860 Connector saver MWDM2L-51USP1 Local network connection TRD855PL-50 CAT5 Ethernet 10/100 Base Local PC Serial port connection and adapter TDC003-7, (RECO98M Connectors) RS-232 Cable Debug 4.1.7 DAQ & FSW V3 19

Verification Level Module Detail Breakout of verification at TEM/TPS Module Level Tests to be conducted after successful TRR At assembly vendor Functional test Vibration Functional test Thermal cycle Functional test Pre-ship review At SLAC Incoming functional test Mass properties Thermal vacuum (in-situ testing) EMI/EMC Functional test Review Deliver to I&T» DAQ (out-going) / I&T (incoming) test combined In the following slides first the work/tests at the assembly vendor is defined, then the work/tests at SLAC 4.1.7 DAQ & FSW V3 20

At Assembly Vendor Test-Stand Supplied by SLAC Operated by SLAC engineers Vibration facility at General Technology Vibration test-procedure http://www-glast.slac.stanford.edu/elec_daq/reviews/tem-trr/sk-282-slac- ESS-Procedure-11-03-04.pdf Also includes» Thermal test procedures» Environmental chamber (thermal/vibration) description SLAC engineers present for vibration tests Work at assembly vendor specified in SOW LAT-PS-02615 4.1.7 DAQ & FSW V3 21

Process & Test Flow-GTC (Assembly Vendor) See also in more detail in http://www-glast.slac.stanford.edu/elec_daq/reviews/tem-trr/sk-282-slac-ess- Procedure-11-03-04.pdf Assemble TEM/TPS Stake HW Vibration Test Functional Test Functional test Thermal test Final functional test Source inspection &EIDP review Pack & ship to SLAC 4.1.7 DAQ & FSW V3 22

GTC Qualification and Acceptance Test Matrix CCA Qual Unit (Qty. 1) Module Qual Unit (Qty. 1) TEM/TPS Qual Unit (Qty. 1) CCA Production Units (Qty.21) Module Production Units (Qty. 21) Initial ambient x x x x x x Thermal Cycling (Qualification) x x x Thermal Cycling (Acceptance) x x x Post Thermal Cycle Funtional x x x x x x Low Level Sine Sweep x x Random Vibration (Qualification) x Random Vibration (Acceptance) x Low Level Sine Sweep x x Final Performance x x TEM/TPS Production Units (Qty. 21) 4.1.7 DAQ & FSW V3 23

GTC Environmental Test Requirements Parameter Required Characteristic Thermal Cycling (4 cycles) -40 to +55 C (Qualification) Thermal Cycling (4 cycles) -35 to +50 C (Acceptance) Random Vibration See Figure 1. Sinusoidal Vibration 0.5g rms, 20 to 2000Hz 1.000 ASD Level (G 2 /Hz) Freq (Hz) Accept Qual 20 0.010 0.010 80 0.040 0.040 150 0.040 0.076 220 0.040 0.076 260 0.040 0.040 500 0.040 0.040 2000 0.010 0.010 Overall 6.8 Grms 7.1 Grms Duration 60s/axis AT, PT 120s/axis QT 0.100 0.010 0.001 ASD Level (G^2/Hz) Accept Qual 10 100 Freq. (Hz) 1000 10000 Figure 1. Vibration Levels, Duration, and Spectra 4.1.7 DAQ & FSW V3 24

Manpower & Quality Assurance at Assembly Vendor Man-Power Thermal and vibration test man-power provided by assembler Test man-power supplied by SLAC TEM: L. Sapozhnikov TPS: D. Nelson Test Support: J. Ludvik Quality assurance: see below Quality Assurance Assembly QA by vendor as required by SOW On-site, full-time LAT QA presence (P. Lujan) Required changes to documentation at GTC is immediately documented on an NCMR and forwarded to SLAC for disposition All outstanding changes to documents are incorporated and a new revision released into LAT DOCs prior to final inspection at each manufacturing/test level (CCA, Module, Top Assembly) 4.1.7 DAQ & FSW V3 25

At SLAC After TEM/TPS module has been shipped from assembly vendor to SLAC: Test-Stand Supplied by SLAC, operated by SLAC engineers Work flow Functional Test Mass Property Plus C.G. measurement Thermal Vacuum (in-situ testing) Functional Test Ship to EMI/EMC vendor EMI/EMC test Ship back to SLAC Final functional test Review 4.1.7 DAQ & FSW V3 26

Mass Property Mass properties checked at SLAC Procedure in progress (done at SLAC Metrology) Measured on EM (ref LAT-TD-00564) TEM 2.710 kg TPS 4.340 kg TEM/TPS Total 7,050 kg Allocation 12% above = 7,896 kg C.G. to be measured for the qualification unit 4.1.7 DAQ & FSW V3 27

Thermal Vacuum Test Thermal Vacuum facility in Building 33 at SLAC Thermal Vacuum Chamber Operating Procedure LAT-TD- 02541 (draft in review) TEM/TPS Thermal Vacuum Test-Procedure LAT-TD-03631 ( draft in review) Chamber was relocated to Building 33 from Central Lab Needs earth-quake securing, in progress (by 1/10) Needs recalibration (by 1/15) 4.1.7 DAQ & FSW V3 28

Qual and Flight Acceptance Thermal Vacuum Test See TEM/TPS Thermal Vacuum Test-Procedure LAT-TD-03631 At < 10-5 Torr 4.1.7 DAQ & FSW V3 29

Manpower & Quality Assurance at SLAC Man-Power Thermal Vacuum test (R. Williams, J. Ludvik) Test man-power supplied by SLAC TEM/TPS: L. Sapozhnikov, D. Nelson, J. Ludvik Quality Assurance LAT QA already present at SLAC Required changes to documentation is immediately documented on an NCMR 4.1.7 DAQ & FSW V3 30

EMI/EMC Test Qualification Test (Conductive & Radiative) Sub-contracted to CK Labs Statement of Work: LAT-PS- 04568 CE102, CECN, CS102, CSCM, CS06, RE101, RE102, RS101, RS103 Detailed EMI/EMC procedure deliverable by vendor (in work) Required to be reviewed/released prior to tests SLAC engineers present at vendor for tests Vendor supplies test-report LAT QA at SLAC present for tests Flight Acceptance Test (Conductive) Performed at SLAC Procedure in work Required to be reviewed/released prior to tests CE102, CS102 SLAC supplies test-report LAT QA at SLAC present for tests 4.1.7 DAQ & FSW V3 31

Problem Failure Report/ Configuration Management Problem Failure Reporting Via standard SLAC LAT Non-Conformance Reporting (NCR) System NCR is entered Reviewed/accepted/resolved LAT engineering LAT QC Already exercised during past TEM/TPS assembly Configuration Management Via standard LATDOC system 4.1.7 DAQ & FSW V3 32

Planned Tests Function/Performance Tests (LAT-TD-01485) Verifies all requirements in LAT-SS-05533 except below Thermal Vacuum Tests Verifies performance/function over temperature Mass/C.G. Verifies/measures mass and C.G. Vibrations test Verifies vibration performance requirements EMI/EMC Verifies EMI/EMC performance 4.1.7 DAQ & FSW V3 33

Equipment Calibration Electrical Functional Test Equipment EGSE Test-Stand was certified by SLAC (will be posted on LAT EGSE web-site shortly) EMI/EMC Test Equipment Quantitative measurement equipment (sensors, antennas, etc) calibrated to NIST standards Calibration performed annually All item are (will be) within calibration at time of testing Vibration Test Equipment Accelerometers calibrated against a standard accelerometer traceable to NIST Signal conditioners calibrated annually TVAC Equipment Thermocouples calibrated against standard temperature; calibrated prior to test Thermocouple reader calibrated very 2 years 4.1.7 DAQ & FSW V3 34

Sub-System System Safety EGSE Safe-to-mate Configuration control Calibration verification Functionality verification with golden TEM/TPS prior to test with flight hardware MGSE No custom MGSE Environment Temperature controlled in all test-facilities Cleanliness actively controlled in clean-room; hardware bagged and purged when required Training ESD training completed Clean room training completed 4.1.7 DAQ & FSW V3 35

Risk Assessment GTCC/GCCC TEM ASICs qualification program not completed at GSFC No issue to-date Test completion end of February ACTEL FPGA s TEM s use relatively new UMC fabrication-line space-qualified FPGA s, no flight heritage ESD sensitivity of ASIC s higher than expected (200V, class 0) Mate-demate and safe-to-mate are of concern when connecting/disconnecting TEM to front-end test (simulator) board. Keep cables as short as possible, apply handling taught in ESDtraining, use de-ionizers Schedule Pressure to deliver flight hardware could force less than complete characterization and analysis of modules, could result in replicating a problem in follow-on modules Performance None known 4.1.7 DAQ & FSW V3 36

Test-Schedule Depending on assembly vendor, estimate as follows 1/10/05: functional test of qual/twra/twrb 1/11-12/05: vibration test of qual/twra/twrb 1/13/05: functional test of qual/twra/twrb 1/14-15/05: TC of qual/twra/twrb 1/16/05: functional test of qual/twra/twrb 1/17-21: review/shipping 1/24/05: functional test of qual/twra/twrb 1/25/05: mass, c.g. property test of qual/twra/twrb 1/26/05: TV start of TwrA, end Feb 2 2/3/05: EMI/EMC of TwrA, end 2/5/05 2/7/05: TV start of TwrB, end Feb 14 2/15/05: EMI/EMC of TwrA, end 2/16/05 2/15/05: TV start of Qual, end Feb 22 2/22/05: EMI/EMC of Qual, end 3/8/05 4.1.7 DAQ & FSW V3 37

Status of Main Test Procedures TEM/TPS Performance Test Procedure LAT-TD-01485: released Vibration & thermal cycle procedure GT procedure SK-282-SLAC: approved EMI/EMC Qual CKC Lab procedure: will be started 2 nd week of January Flight Working together with TKR to get procedure finished by 3 rd week of January (procedures are similar) Thermal Vaccum LAT-TD-03631, in draft form All procedures must be released before respective test 4.1.7 DAQ & FSW V3 38

Issue & Concerns EMI tests Concern passing qualification tests Schedule Tight Qualification and Flight acceptance tests of flight TEM/TPS are performed with front-end simulators, not with actual CAL or TKR electronics In the planning phase: Taking qualification module after baseline environmental testing is completed Connect it to CAL AFEE / TKR MCM electronics Test over temperature (no vacuum required) Need documentation Possible for every flight modules: schedule issues 4.1.7 DAQ & FSW V3 39