Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Similar documents
P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

OPERATION MANUAL NTF-15

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

OPERATION MANUAL NTF-60 Plus

256 Pneumatic Pressure Indicator

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

OPERATING AND MAINTENANCE MANUAL

accidents which arise due to non-observance of these instructions and the safety information herein.

GBK-50M / GBK-110M. Booster. Instructions. Introduction. How to Contact Fluke Calibration

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Operation & Service Manual

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Pressure Regulators. Operating Instructions. Instrumentation

Spot Weld Drill Spot Weld Removal System Instruction Manual

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

MEGR-1627 Instruction Manual

User Operation Manual and Safety Instructions

Rejuvenation Instructions

750 Cable Cutter INSTRUCTION MANUAL

Operating Instructions Models and Hydrostatic Test Pumps

Freedom8 ShoeBox Compressor Manual

PANACEA P125 USER MANUAL

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

HPB25 Hydraulic Paving Breaker

NTF-515. Operation Manual

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Adjustable. Unloader Valve. O&M Manual. Part #

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

CS150 CAP STAPLER OWNER S MANUAL

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Oxygen Usage Best Practice Guide

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

SILENTAIRE TECHNOLOGY

PANACEA P200 STAINLESS STEEL USER MANUAL

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Smooth Vent Valve. XVD Series

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

STIH) Technical Information Accessories for STIHL cut-off machines / drills. 1. New pressurized water tank

GB-H M and GB-H M Gas Booster Packages Operation and Maintenance Manual

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Welcome to the Specialized Medical Services Respiratory training webinar series!

MANUAL BE SERIES Test Benches

Operation Manual Air Saver Unit ASV5000 Series

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Hydraulic Punch Drivers

Installation, Operation, and Maintenance Manual

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

PANACEA P100 LOW PRESSURE USER MANUAL

Types 749B and R130 Changeover Manifolds

AA-75CF Portable Air Compressor NSN:

RhinoPro Cartridge Gun Manual

Hydraulic Punch Drivers

Operating Instructions Models and Hydrostatic Test Pumps

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

Installation Instructions for NP100 Series Nitrogen Control Panels

Pressure Dump Valve Service Kit for Series 3000 Units

SINORIX Valve Reconditioning

Genie Supreme Model 123 Installation & Operation Instructions

Beverage Systems. Component Inspection and Service TSB-Y Date: Subject: Products Affected: Description: July Inspection of CO 2

Model Air Caddy Orig TABLE OF CONTENTS

Operating Instructions Model and Hydrostatic Test Pump

CSA Sample Draw Aspirator Adapter Operator s Manual

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Hydraulic Piston Accumulators

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

User Instruction Manual

G7S Hand Pump Owner s Manual

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

OWNER S TECHNICAL MANUAL

MAYHEM MAYHEM OWNERS MANUAL. Paintball Guns International. Manufactured by

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

OWNERS SERVICE MANUAL NO INSTALLATION, OPERATING & SERVICING INSTRUCTIONS

SAFETY MEASURES. These important guidelines should always be followed to work safely with the PRIMATECH pneumatic stapler model Q180:

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

DPC-30 DPC-100. Reference Manual

Techcon Systems TS1254 Pressure Pot

1020 Industrial Drive, Orlinda, TN fax

SUPER PRECISION AIR RELAYS

Smooth Vent Valve XVD. Series

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Pressure on Demand. Air Pressure Amplifiers

Transcription:

Operation Manual - PN 0017946001 A MENSOR MODEL 73 SHOP AIR BOOSTER Mensor Model 73 Shop Air Booster System (750 psi Version) April 23, 2012

Trademarks / Copyright Mensor is a registered trademark of Mensor Corporation. All other brand and product names are trademarks or registered trademarks of their respective companies. 2010 Mensor Corporation. All rights reserved.

Operation Manual Mensor Model 73 Shop Air Booster System GENERAL INFORMATION The Mensor Model 73 Shop Air Pressure Booster generates 325 psi to 750 psi using a 70 psi to 150 psi clean dry shop air source. The Model 73 consists of a single 5 to 1 pressure boost stage with limits for speed control and maximum output pressure control. To achieve the 325 psi output, a minimum supply of approximately 70 psi is required. To achieve 750 psi, a 150 psi supply is required. 150 psi is the maximum input pressure the unit should be subjected to. The unit is purely a mechanical device and has no electrical requirements. WARNINGS AND SAFETY PRECAUTIONS High Pressure Gas can be extremely dangerous if improperly handled. Unit should be operated, adjusted and maintained by qualified personnel trained in high pressure pneumatics. All Tubing, Fittings and connected devices must have a working pressure rating equal to or greater than the maximum required pressure. All connections should be in good mechanical condition, i.e. good threads on fittings, tubing free of kinks or nicks, etc. All connections should be properly installed and tightened. Small articles exposed to the escaping gas can be propelled at ballistic speeds to the endangerment of nearby personnel and equipment. Under certain conditions the noise level created by gas exiting equipment under high pressure can become dangerously high. The maximum input pressure to the unit is 150 psi gauge pressure. The input regulator and the input filter are rated for 150 psi maximum. INITIAL SETUP AND CHECKOUT On initial setup, user should check to insure no shipping damage has occurred to the unit or the container it was shipped in. Prior to connecting pressure, check all hoses for kinks and nicks and insure fittings are snug. Verify that the regulator filters are not contaminated with

liquid or particulates. User should verify input pressure (shop air) is within the operating range of the booster and within the range of any test device connected prior to applying the input pressure. Although the regulator pressure settings have been set at the factory, the user should on initial application verify the incoming shop air is 150 psi or less and the input pressure gauge on the rear of the unit is approximately 50 psi or less. The black regulator knob should be used to adjust the input pressure either increasing or decreasing the output pressure as appropriate. The front panel gauge shows the actual output pressure value. Once the system is operational, the black regulator knob should be used to set the final output pressure to match the application and the controller full scale. Some final adjustments may be required to compensate for differences in actual supply pressure. PORTS, CONTROLS AND ADJUSTMENTS There are two pressure ports on the rear of the Model 73 chassis. The input pressure port is designed for a shop air supply which functions as the drive pressure as well as the output media. It should be clean dry compressed air (or Nitrogen) at a pressure of 70 to 150 psi. (Absolute Maximum Input Pressure is 150 psi to the rear mounted pressure filter.) This pressure is regulated down to a typical working pressure of 50 to 150 psi. The second pressure port is the HIGH PRESSURE OUTPUT port. It is designed for a typical output pressure of 325 to 750 psi. The mechanical advantage is derived by using differing piston area sizes to generate high pressures. The output equation is : Output Pressure = Input Pressure + (Regulated Pressure * 4) The input port is a 3/8 Swagelok male type tube fitting mounted on the external pressure filter. The Output port is a ¼ Swagelok male type tube fitting. Input Pressure Port The input pressure port labeled INPUT PRESSURE is used to supply and drive the booster and is intended to be connected to a shop air supply of 70 to 150 psi (150 psi max). The port is a 3/8 male Swagelok type tube fitting mounted on the end of a pressure filter. A 200 psi rear mounted panel gauge provides an indication of the regulated shop air pressure input. If shop air is not present on the gauge the user should check to see if the shop air is present on the input port and the regulator knob is not fully counterclockwise. The input regulator filter provides basic filtering of large particles and liquids. It should periodically be checked for excessive contamination and emptied of liquids. Note: The input pressure supply should have

sufficient capacity (flow) to maintain the input pressure setting. Failure to do so may cause the booster to short cycle and not be able to achieve the desired output pressure. If external regulators are in line with the shop air supply, make sure that they do not restrict the input flow. Also use large diameter supply hoses (3/8 or larger) is recommended. High Pressure Output Port The output pressure port is a ¼ male Swagelok type tube fitting. The actual output pressure can be monitored with the pressure gauge located on the front panel. The output pressure is a combination of the raw input supply pressure plus four times the regulated pressure as read on the Regulator Pressure gauge. It can be adjusted with the black Regulator Adjustment Knob. OPERATION While operation of the booster system is quite simple, high pressure gas is dangerous. NOTE: Operation of this unit and maintenance of this unit should be performed by qualified personnel only. 1. Connect a low pressure supply such as shop air to the INPUT PRESSURE port. The system requires a minimum of 60 psi to obtain 300 psi output. 2. Connect the load (pressure controller) to the HIGH PRESSURE OUTPUT port. Be careful to use tubing rated for the boosted working pressure. 3. Slowly apply shop air to the INPUT PRESSURE port while monitoring the OUTPUT PRESSURE gauge on the front of the unit. For most applications, the booster piston temperatures will not be a problem. However, if a particular application causes the booster piston to operate frequently, the high pressure end of the booster cylinder may overheat. Temperatures in the cylinder above 300 degrees F will considerably shorten the life of the Rear View piston seal. Temperatures can be minimized by reducing the drive speed while still maintaining the output pressure, but at a slower recharge rate. The drive speed is adjusted by removing the top cover and adjusting the yellow ball valve lever. The unit is shipped with this lever in the wide open position. Experience has shown, that under all but the most extreme conditions, temperature problems should be of no concern. DISCONTINUE OPERATION To discontinue operation of the booster system:

1. Valve off any pressure going to the INPUT PRESSURE port. Disconnect the supply gas if desired. Alternately, the Regulator Pressure knob can be adjusted until the regulator pressure reads zero. 2. With the input pressure shut off, slowly vent the output pressure by cracking the output connector to let the pressure slowly release or by continually cycling the controller between an acceptable control pressure and vent until pressure is drained. Maintain a safe noise level when venting. Wait until the output gauge reads 0 psi before disconnecting the controller or load. TROUBLESHOOTING This section provides simple operational checks. The Haskel AAD-5 manual attached contains additional information. If the unit does not pump 1. Verify that the INPUT PRESSURE has pressure applied. 2. Verify that the regulator pressure knob is slightly open and the Regulator Pressure gauge reads approximately 50 to 150 psi (just not at zero). If the unit continually cycles after reaching pressure and the temperature of the gas has stabilized or when cycling occurs when not being used. 1. Check for leaks in the system. Use a leak detector to track down and correct the problem. MAINTENANCE NOTE: High Pressure Gas can be dangerous. Maintenance of this unit should be performed by fully qualified personnel only. Booster Unit: The control valve and the pilot valves on the Haskel Booster may occasionally need relubrication on units experiencing a high amount of use. Instructions and a special lubricant are provided in the Haskel manuals in the Appendix. Drive Pressure Filters Each booster is equipped with a filter and regulator. The filters should be inspected on a regular basis. Drain any accumulated moisture or sludge through the drain petcock on the base of the filter. Occasionally, clean the internal filter element inside the filter sediment bowl. To access the element, first disconnect all pressures from the system. Unscrew the filter bowl ring nut by hand and remove the bowl and filter element screw.

Clean the bowl with either soapy water or kerosene. Clean the element with a cleaning solvent. Dry all the parts and reassemble. Make sure that the o-ring seal for the bowl is properly positioned, replace the bowl and tighten the ring nut by hand. The Haskel recommended maintenance schedule is listed in the appendix.

High Pressure Output Gauge Front View Regulator Adjust High Pressure Output Port (750 PSI Max.) Regulator Gauge (50 to 150 psi) Input Pressure Filter (See Maintenance Section) Input Pressure Port 150 psi Max. Speed Adjust Lever (located inside chassis) Moisture Trap Release Valve Rear View

SPECIFICATIONS Input Pressure: Dry Compressed air or Nitrogen at a maximum of 150 PSI (1.03 MPa) Output Pressure: Compressed air or Nitrogen up to 750 psi with appropriate supply pressure Not to exceed 750 psi maximum. Charge Noise Level: Approximately 80 dba intermittent pulses measured at 1 meter Weight: 45 lbs or 20.4 kg Size: Rack Mounted 7U Chassis, 19 wide, 10.5 tall, 17.25 deep (482.6 mm x 266.7 mm x 438.15 mm) (User accessible filter extends depth by an additional 5 or 127 mm in the rear.)

APPENDIX Haskel Operating and Maintenance Instructions

Mensor Corporation 201 Barnes Drive San Marcos, Texas 78666-5994 Phone: 512.396.4200 Fax: 512.396.1820 Web site: www.mensor.com E-mail: sales@mensor.com