JLab Cryogenic Plant Capacities

Similar documents
System Optimization &

Cryogenics The Basics. Lesson 2 D. Kashy

Cryogenics of SRF Spoke Cavity Development at SMTF

Oxygen Deficiency Hazard Safety Booklet

Refrigeration Plants for the SSC

A Brief Introduction to Helium Liquefaction At ITER

SUMMARY AND RESULTS OF THE CRYOPLANT OPERATION FOR HERA

ESS Cryogenic System Process Design

Spallation target cryogenic cooling design challenges at the European Spallation Source

Proposal for the Cryogenic Supply of a Single TTF / FEL - Cryomodule Test Bench

Safety in Cryogenic Operations at RHIC *

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

ESS SPOKE CRYOMODULE AND TEST VALVE BOX

ATL. Take Control of your Helium Supply. Advanced Technology Liquefier The next generation of helium recycling

Specifications of Cryogenic vacuum jacketed valves

Storage and transfer of cryofluids

C2-B-03 Spallation Neutron Source Cryogenic System Installation. September 24, 2003

PRad Target. Chris Keith JLab Target Group

Thomas Jefferson National Accelerator Facility Newport News, Virginia, 23606, USA

Numerical Tools for LCLS-II Vacuum Systems

Magnet and RF Cavity Test Stand Design. Tom Peterson, SLAC USPAS January, 2017

LARGE CRYOGENIC SYSTEMS AT 1.8 K

Figure 1 The LHC cryogenic islands and plants layout

Research activities on cryogenic safety

FAILURE SCENARIOS AND MITIGATIONS FOR THE BABAR SUPERCONDUCTING SOLENOID

- Brief overview of the Tevatron cryogenic system - Operations for Run II

COMMISSIONING REPORT OF THE MUCOOL 5 TESLA SOLENOID COUPLED WITH HELIUM REFRIGERATOR

EXPERIENCE WITH CRYOGENICS SAFETY, PROBLEMS AND SOLUTIONS

Hall C SHMS Q2, Q3, and Dipole: Magnet Pressure Safety. Eric Sun. October 12, Experiment Readiness Review of Physics Division.

Fermilab MTF Cryogenic System & Vertical RF Cavity Test Facility. Yuenian Huang, on behalf of Fermilab, TD/TID May 11, 2006

CRYO. SuperVariTemp Magnet Inserts

Cryomodule Maintenance Workshop Maintenance, Repair Strategies, and Fault Scenarios. J. Ozelis Senior SRF Coordinator

Cryogenic Considerations for Cryomodule Design. Tom Peterson, SLAC USPAS January 2017

The LHC Cryogenic System and Operational Experience from the First Three Years Run

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

Achieving Ultra-High Vacuum without (in-situ) Bakeout

PURCHASE AND DELIVERY OF A HELIUM CLOSED-CYCLE OPTICAL CRYOSTAT. The present tender is only an unofficial translation provided as a courtesy.

RECENT PROGRESS IN POWER REFRIGERATION BELOW 2 K FOR SUPERCONDUCTING ACCELERATORS

SPECIFICATION FOR AN MRBR 9.4 TESLA/310MM/AS CRYO-COOLED MAGNET SYSTEM

3-Stage ADR for the SXS Instrument on the Astro-H Mission

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

The Model L1410 can be counted on for many years of trouble-free, reliable operation.

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

LESER Deutschland Standard Functional Tightness Test (Cryo) Content

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

RHIC CRYOGENIC SYSTEMS MAINTENANCE PROGRAM

An Assessment of the Hall D Magnet Work Scope at JLAB. April 5, Introduction

First Experimental Data of the Cryogenic Safety Test Facility PICARD

Vacuum Jacketed Piping Solutions

NPDGamma LH2 Target OJT Lesson Plan: Senior Operator for the NPDGamma LH2 Target Operators

Cryogenic system for SCC horizontal test

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

EXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC MAGNETS

2.8 Beam Stops Introduction. 2.8 Beam Stops

Cryocooler-Based Helium Recovery Plant for Applications Requiring Gas or Liquid with Extreme Purity

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

ENGINEERING DESIGN OF CRYOCONDENSATION PUMPS FOR THE DIII-D

The Committee is asked to report to the LANSCE-12 group leader, Alan Hurd. The Committee is asked to;

HAUG Kompressoren AG. Founded in Design & manufacturing in St. Gallen Switzerland. Own sales subsidiaries in Frankfurt and Shanghai

Temporary Connections to Process. Supersedes: 10/31/09 (Rev.02) Preparer: Owner: Approver: EHS Team Member EHS Team Member EHS Manager

A NEW PROCESS FOR IMPROVED LIQUEFACTION EFFICIENCY

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Step By Step Instructions for VT Experiments on the Bruker 300 MHz Spectrometer

Cooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

TECHNICAL INSTRUCTION

Oxford Instruments Austin, Inc.

Cryogenic Equipment. Accessories. Directors. Director Series Storage Vessels Specifications

TURBO OXYGEN NITROGEN PLANT

Cryostream 800 Series

European Organization for Nuclear Research - Organisation européenne pour la recherche nucléaire

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler

Ingersoll Rand. X-Series System Automation

High Pressure Compressed Air and Gas Solutions

ACCELERATOR INSTALLATION SAFETY SUPPORT Strategy and lessons learned

TECHNICAL INSTRUCTION

Oxford Instruments Austin, Inc.

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

Practical Modelling & Hazard Assessment of LPG & LNG Spills

Current Leads for Cryogenic Systems

Quantitative study of sniffer leak rate and pressure drop leak rate of liquid nitrogen panels of SST-1 tokamak

PRELIMINARY RISK ANALYSIS OF THE LHC CRYOGENIC SYSTEM

Trillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

Title: Choosing the right nitrogen rejection scheme

Cryogenic Distribution System (CDS) for Eight HERA Superconducting RF Cavity Cryostats

Vacuum System at IUAC

MODIFICATION OF THE LHC VENTILATION SYSTEM

4m Blanco Glycol Chiller system: history, recent events, present status and plans

Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors

TECHNICAL SPECIFICATION. SPC-1 Stirling Process Cryogenerator

TECHNICAL SPECIFICATION. SPC-4 Stirling Process Cryogenerator

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

Loss of Vacuum Experiments on a Superfluid Helium Vessel

DEVELOPMENT OF LARGE-CAPACITY REFRIGERATION AT 1.8 K FOR THE LARGE HADRON COLLIDER AT CERN. Philippe Lebrun*, Laurent Tavian*, Gérard Claudet**

CRYO INDUSTRIES. Liquid Helium Research Dewars

PRESSURE EQUIPMENT: REGULATIONS AND INSPECTIONS CODE NSH 222 Date: July 2003 Revision: 00 Page: 1 of 7

KGW-ISOTHERM. Information and Operating Instructions for Dewar Vessels Type 26 to 29 B or B-E

CNS In-Pool Assembly Mechanical Design for OYSTER Project

Transcription:

JLab Cryogenic Plant Capacities March 26, 2010 Rao Ganni http://www.jlab.org/div_dept/dir_off/ccr/ Thomas Jefferson National Accelerator Facility

Cryogenic Plant Locations & Interconnecting Transfer Lines Thomas Jefferson National Accelerator Facility Page 2

FEL, 2K JLab Transfer Lines 2K Linacs CHL + SBR, 2K/4K CHL TL To Be Removed ESR, 4K CTF, 4K A B C Thomas Jefferson National Accelerator Facility Page 3

Typical Transfer Lines 4K, Warm Helium & LN2 Transfer Lines CHL to ESR Thomas Jefferson National Accelerator Facility Page 4

Transfer Line Capacities and Heat Load 4K, 30 grams/sec max flow capacity, 5 grams/sec to keep transfer line cold (heat leak) CHL to ESR ESR to CTF (Being removed for TEDF building) 3K/2K, 35 grams/sec max flow capacity, 10 grams/sec of which to keep transfer line cold (heat leak) CHL to FEL 4K, 10 grams/sec TL design flow capacity for ESR to each of Halls A,B,C; Hall A is using 40 g/s (~60% of Refrigerator Capacity) ESR to Each Hall Thomas Jefferson National Accelerator Facility Page 5

JLab Cryogenic Plant Capacities Thomas Jefferson National Accelerator Facility

CHL Max Capacity Current 6 GeV (CHL #1) Load: 4.25 kw @ 2.1K, 11.65 kw @ 35K Capacity: 4.6 kw @2.1K, 12 kw @ 35K 10 g/s liquefaction @ 4.5K New 12 GeV (CHL #1 + new CHL#2) Load: 7.4 kw @ 2.1K, 14.65 kw @ 35K Capacity: 8.8 kw @ 2.1K, 24 kw @ 35K 10 g/s (CHL#1) plus 15 g/s (CHL#2) of liquefaction Thomas Jefferson National Accelerator Facility Page 7

11126 GeV CEBAF Upgrade magnets and power supplies CHL-2 Two 0.6 1.1 GV linacs Enhanced capabilities in existing Halls Lower pass beam energies still available Thomas Jefferson National Accelerator Facility Page 9

NEW LINAC TL CONFIGURATION CURRENT 6GeV: CHL-1 Supplies Injector, N. and S. Linacs, FEL, and 10 g/s to ESR NEW 12 GeV: CHL-1: Injector, North Linac and ESR (10 g/s) CHL-2: South Linac and existing FEL NOTE: IN CASE OF A CHL-1 OR CHL-2 FAILURE, THE LINAC CAN BE RECONNECTED TOGETHER INTO SINGLE REMAINING CRYO PLANT FOR 6 GeV BEAM OPERATION Thomas Jefferson National Accelerator Facility Page 10

Requirement: LINAC TRANSFER LINES NEW FOR 12 GeV NEW 12 GeV 600W @2.1K on SL Thomas Jefferson National Accelerator Facility Page 11

Loads/Capacities: 6GeV/12GeV Breakdown (Accelerator Only) Unit Loads 6 GeV North Linac 12 GeV South Linac 2 K 50 K # 2 K 35 K # 2 K 50 K # 2 K 35 K Loads (#,W) Static Transfer Line 530 7000 1 530 7000 0.57 302 3990 0.43 228 3010 Original CM s 16 110 42.25 676 4648 22.25 356 2448 20 320 2200 12 GeV CM s 50 250 5 250 1250 5 250 1250 Dynamic Original CM s 72 42.25 3042 22.25 1602 20 1440 12 GeV CM 250 50 5 1250 250 5 1250 250 TL BAYONETS 75 75 Totals 42.25 4248 11648 25.25 3835 7938 29.25 3563 6710 TL SECTION Capacities (W) CHL#1 (W) 4600 12000 4400 12000 % of Full Load 92% 97% 87% 66% CHL#2(W) 4400 12000 % of Full Load 81% 56% Adding Existing 600W @ 2K for FEL on South Linac, ~95% Loading @2K for CHL#2 Thomas Jefferson National Accelerator Facility Page 12

ESR CRYOGENIC CAPACITY Serves Experimental Halls A,B,C Built in 1977 PROVIDES 1500W @4K HELIUM REFRIGERATION OR 11 GRAMS/SEC 4K LIQUEFACTION (CAN RECEIVE ADDITIONAL 10 G/SEC LIQUEFACTION FROM CHL VIA TL) Thomas Jefferson National Accelerator Facility Page 13

CTF CRYOGENIC CAPACITY Built in1989 35K Shield Refrigerator and 2K Liquefier 1kW @ 35K Shield Refrigerator 5 grams/sec 2K Liquefier (Average) User Max Draw, 15 g/s from Storage Dewar For Peak Refrigeration Loads Thomas Jefferson National Accelerator Facility Page 14

HALL D CRYOGENIC CAPACITY Built 1980 Hall D 4.5K Refrigerator 200W @ 4K Refrigeration or 2 g/s Liquefaction Capacity Hall Mixed Load 0.7 g/s liquefaction + 100W Refrigeration (includes transfer line load) Thomas Jefferson National Accelerator Facility Page 15

ESR#2 REFRIGERATOR CAPACITY (Unfunded BIA, Not Installed) Proposed Refrigerator to Boost 6 GeV Program Fabricated in 1992 4kW @ 4K Refrigeration Or 5 kw @ 20K Refrigeration (modified cold box) Thomas Jefferson National Accelerator Facility Page 16

STANDBY REFRIGERATOR (SBR) CAPACITY Replaces CHL during CHL Major Maintenance Or Emergency Backup to CHL @ 4K Built in 1996 1.8kW @ 4K + 12kW @ 35K Shield Refrigeration Or 20 grams/sec Liquefaction Can no longer meet static load of all cryomodules in emergency backup mode Thomas Jefferson National Accelerator Facility Page 17

Questions? May we answer any questions? Thomas Jefferson National Accelerator Facility Page 18