PRELIMINARY DATASHEET

Similar documents
AMS 6916 Board mount pressure sensor with ratiometric analog output

Connections The C20B can be connected either using the Molex locking socket, or by connection to four plated through holes. The plated through

AMS 6915 Board mount pressure sensor with digital output (I²C)

GasSense NDIR User Manual

AMS 2710 PCB pressure sensor module with V output

O3 3E 1 F Gas Sensor Module

Datasheet: K-30 ASCII Sensor

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Operation manual Oxygen sensor

NOVALYNX CORPORATION MODEL BAROMETRIC PRESSURE SENSOR PCB MODEL BAROMETRIC PRESSURE SENSOR IN NEMA ENCLOSURE INSTRUCTION MANUAL

NIBP OEM Module. (Model : M_NIBP) Contents. 1. Concept 2. Composition 3. PCB Dimension 4. Specification 5. Protocol 6. Cuff & Electrical Connection

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

SX150A. Features. Typical Applications. Description

ASDX Series Silicon Pressure Sensors

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Sensoric 4-20 ma Transmitter Board Operation Manual

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

Precision pressure sensor Basic version Model CPT6020

D-Opto Dissolved Oxygen Sensor Operation Manual

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

M iniature Amplified Pressure Sensors

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co.

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

MANUAL KPS Pressure Control Valve

D-OptoLogger Dissolved Oxygen Logger Operation Manual

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

HY-OPTIMA 740 In-Line Process Hydrogen Analyzer (%H 2 S & CO)

Installation and Operation Manual

OXY-Flex Oxygen Analyser

Optical Dissolved Oxygen Meter

HTD series digital differential pressure sensors

TR Electronic Pressure Regulator. User s Manual

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

HumiSys HF High Flow RH Generator

MODEL GT820 OXYGEN SENSOR

Manual. MEMS Combustible Gas Sensor. Zhengzhou Winsen Electronics Technology Co., Ltd. (Model No.:GM-402B) Version: 1.0. Valid from:

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

MARTINI. instruments. THANK YOU FOR CHOOSING. Sales and Technical Service Contacts:

Application Note AN-107

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Instruction and Maintenance Manual

Model FS5001B VA.1. MEMS Mass Flow Sensors ISO 9001 ISO OHSAS 18001

PRODUCT MANUAL. Diver-MOD

GAS FUEL VALVE FORM AGV5 OM 8-03

OXY 3690 MP. Measuring transducer for air oxygen

BI-680 Online Dissolved Oxygen Controller Instruction Manual

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

MEC OEM. User Manual. Commercial in Confidence

USER'S GUIDE. Vaisala CARBOCAP Carbon Dioxide Calibrator for the GMP220 series probes GM K220 U421EN-1.1

HPSD 3000 Pressure Transducer

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

PRODUCT MANUAL. Diver-DCX

DTG - LCD Digital Temperature Gauge USER MANUAL

E instruments 7823 Oxygen Analyser

SENSORS Pressure CALDARO

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

Differential Pressure Transmiter

Optical Dissolved Oxygen Meter

FTC130 Transmitter. Operating Manual

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

Instruction and Maintenance Manual

DESCRIPTION FEATURES

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Fixed Ozone Monitor User Manual December, Automatikprodukter

86BSD Backside Digital Output

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

User manual CF8-D/W-IN

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Ultima. X Series Gas Monitor

P499 Heavy Duty Pressure Transducer

Datasheet May, 2017 HPSD 4000 Pressure Transducer 1/5. Applications

TH-1800-T TRX-700-CNG Converter

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Electrochemical Sensor

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

Membrane covered optical CO 2 sensor

Mass Flow Controller (MFC) for Gases

Mass Flowmeters. Mass Flowmeters for Gases

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

Transmitter CS 21 Operation Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Electronic gas volume corrector model DGVC-04

Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17

Operating Instructions

Pneumatic high-pressure controller Model CPC7000

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

Pneumatic high-pressure controller Model CPC7000

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Basic Board Mount Pressure Sensors

Instruction Manual BA90 Precision Barometer

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

Transcription:

GENERAL DESCRIPTION The Family (LOX) is a range of factory calibrated oxygen sensors which measure ambient oxygen partial pressure (ppo₂) levels using the principle of fluorescence quenching by oxygen. By default measures ppo2 (mbar) and temperature ( C). An optional pressure sensor enables to also measure barometric pressure (mbar) and to convert the ppo2 reading to an oxygen concentration (O2%). CLEANING The housing of the sensor can be cleaned using a damp cloth. The sensor should not be immersed in any cleaning media. Full application and technical support can be provided by our knowledgable and highly experienced engineering team if required. The sensor benefits from low power operation, traditionally associated with electrochemical sensors, while providing a much longer lifetime due to the non-depleting sensing principle. is ppo2 and temperature compensated, enabling accurate operation over a wide environmental range without the need for additional system components. Unlike other sensor technologies, is very stable and robust, does not contain lead or any other hazardous materials and has negligible cross sensitivity to other gases. ELECTRICAL AND ENVIRONMENTAL SPECIFICATION Supply Voltage (Vs) Supply Current (Is) Output Type Operating Temperature Storage Temperature Humidity Barometric Pressure Range PERFORMANCE SPECIFICATION* Oxygen Measuring Range Response Time ppo 2 Accuracy / Resolution Temperature Accuracy / Resolution Pressure Accuracy / Resolution O 2 % Accuracy / Resolution Lifetime 4.5 to 5.5 Vdc <7.5mA (streaming 1 sample per second), <20mA Peak 3.3V TTL level RS232-30 C to +60 C -30 C to +60 C 0-99% Rh (non-condensing) 100 to1400mbar (LOX-01) 500 to1200mbar (LOX-02) 0-300mbar ppo₂ 0-25% O₂ (LOX-02) T90 <30s (Typical) <2%FS / 0.1mbar Indication Only / 0.1 C ±5mbar / 1mbar (LOX-02) Determined by ppo 2 and Pressure Accuracy / 0.1% (LOX-02) >5 years *At ambient conditions. All performance measurements are at STP unless otherwise stated. Following extreme temperature fluctuations, re-calibration may be required. BENEFITS Low power Can also measure O 2 % & barometric pressure (LOX-02) Suitable for battery power use Long life High accuracy Small & compact Low cost Maintenance free Contains no hazardous materials Connects directly to microcontroller without any additional circuitry. Factory Calibrated APPLICATIONS Oxygen Detection Portable Equipment Breathing Apparatus Inerting Medical Lab Equipment Agriculture Incubation Fire Prevention Flue Gas in Condensing Boilers MECHANICAL Connection Housing Dimensions 4 gold-plated pins (0.64mm 2 ) on a 2.54mm grid for PCB mounting via sockets or hand soldering with a no-clean flux (do not put the sensor through a PCB washing process) 20mm max diameter x 12.5mm high 2013 SST Sensing Ltd Page 1 of 5 www.sstsensing.com

The range has been designed as an alternative to electrochemical sensors but with the benefits of RoHS compliance, long life and complete environmental compensation built-in. The sensor is available with and without a built-in barometric pressure sensor. s native measurement is partial oxygen pressure (ppo 2 ) in mbar. By incorporating a barometric pressure sensor, is able to measure O 2 vol. % in addition to ppo 2 is designed to measure ambient oxygen levels are therefore the entire sensor must be in the measurement gas for correct operation. Unlike electrochemical sensors, requires no additional signal conditioning circuitry and connects directly to the interfacing microcontroller via 3.3V-level RS232 link. This reduces costs and simplifies system design. Details of the RS232 protocol and commands are given below. RS232 Setup: The following setup should be used when using the RS232 interface. Baudrate: 9600 Flow Control: None Parity: None Stop bits: One Data Length: 8 bits RS232 Command Set: All RS232 communication is performed using ascii characters, Table 1 shows the legal characters for each description block. There are three modes available: Poll Mode, Stream Mode and Off Mode. Description Block Legal Character(s) Hex <Command> M, O, %, T, P, A, #, e 0x4D, 0x4F, 0x25, 0x54, 0x50, 0x41, 0x23, 0x65 <Argument> 0 9 0x30 0x39 <Separator> 0x20 <Terminator> \r\n 0x0D 0x0A Table 1 Poll Mode (M 1): Each request is built using a combination of the description blocks. (See Table 1). A typical arrangement will be one of the following formats: <Command><Terminator> <Command>< Separator><Argument><Terminator> Each response will be in the following format: <Command>< Separator><Argument><Terminator> Page 2 of 5

Table 2 provides a description of all commands and the valid arguments that can be applied to the interface when in Poll Mode (M1). All commands are case sensitive. Command Description Arguments Response M Output Mode 0 = Stream 1 = Poll 2 = Off M xx\r\n Where xx equals the Argument of the command. O Request current ppo 2 value O xxxx.x\r\n Where xxxx.x equals the ppo 2 in mbar % Request current O 2 value (only valid for sensors fitted with barometric pressure sensor. Otherwise returns - - - - - - ) T P Request current temperature inside sensor Request current barometric pressure (only valid for sensors fitted with barometric pressure sensor. Otherwise returns - - - - ) % xxx.xx\r\n Where xxx.xx equals the O 2 in percent % T yxx.x\r\n Where y equals the sign - or + and xx.x equals the temperature in C P xxxx\r\n Where xxxx equals the pressure in mbar e Sensor Status e 0000\r\n = Sensor Status Good e xxxx\r\n = Any other response contact SST Sensing for advice. A Request all values (see above: O, T, P, % and e) # Sensor Information 0 = Date of manufacture 1 = Serial Number 2 = Software Revision See Stream Mode (M 0), Page 4. # YYYYY DDDDD\r\n # xxxxx xxxxx\r\n # xxxxx\r\n Example 1: Table 2 Example 2: Request (What is the current oxygen partial pressure?): O\r\n 0x4F 0x0D 0x0A Response (210.3mbar): O 0210.3\r\n 0x4F 0x20 0x30 0x32 0x31 0x30 0x2E 0x33 0x0D 0x0A Request (Put into streaming mode): M 0\r\n 0x4D 0x20 0x30 0x0D 0x0A Response ( is now in streaming mode): M 00\r\n 0x4D 0x20 0x30 0x30 0x0D 0x0A Page 3 of 5

Error Codes When a request has been unsuccessfully received, an error code may appear in a response format. Table 3 provides more information on possible causes and actions. Response: Description: Possible Cause: Action E 00\r\n RS232 Receiver Overflow No <Terminator> received before overflow. E 01\r\n Invalid Command Unrecognised <Command> received. E 02\r\n Invalid Frame Incorrect character in frame < Separator>. E 03\r\n Invalid Argument <Argument> not allowed or in limits. Check RS232 Setup, Confirm correct termination. Check command is valid Check command is upper Case M instead of m Check correct separator is used. Check Argument is no longer than 6 characters long. Check Argument is within limits Check Argument is available for command. Table 3 pro- Argu- Stream Mode (M 0): By default stream mode is initiated on sensor power-up and will supply an output string approximately once every second. This vides the data for ppo 2, Temperature, Pressure, O 2 and Sensor Status. The format is provided below, for more details on the ment see Table 2. O xxxx.x T yxx.x P xxxx % xxx.xx e xxxx\r\n or the equivalent block description: <Command>< Separator><Argument>< Separator><Command>< Separator><Argument>< Separator> <Command>< Separator><Argument>< Separator><Command>< Separator><Argument>< Separator> <Command>< Separator><Argument><Terminator> Off Mode (M 2): In this mode, stops taking measurements and current consumption reduces to less than 6mA constantly. Page 4 of 5

PRODUCT DIMENSIONS (All dimensions in mm) PINOUT: Pin 1: Vs (+5V) Pin 2: GND (0V) Pin 3: 3.3V RS232 Sensor Transmit Pin 4: 3.3V RS232 Sensor Receive Bottom View Top View NOTES: Always apply power to the sensor pins 1 and 2 before attempting to communicate on pins 3 and 4. The sensor should be treated as an electronic component and handled using the correct ESD handling precautions. PART NUMBERING SYSTEM LOX - XX Type 01: Measures 0-300 mbar ppo 2 and temperature ( C) 02: Measures 0-300 mbar ppo 2, 0-25% O 2, temperature ( C) and 500-1200mbar barometric pressure For additional information or help in choosing the most suitable sensor for your application, please contact us. We can provide full application and technical support on all products. WARNING Personal Injury DO NOT USE these products as safety or Emergency Stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. CAUTION Do not exceed maximum ratings. Carefully follow all wiring instructions, incorrect wiring can cause permanent damage to the device. Do not use chemical cleaning agents. Failure to comply with these instructions may result in product damage. It is the customer s responsibility to ensure that this product is suitable for use in their application. technical assistance or advice, please email us: technical@sstsensing.com For General Note: SST Sensing Ltd reserves the right to make changes in product specifications without notice or liability. All information is subject to SST s own data and considered accurate at time of going to print. 2013 SST Sensing Ltd Page 5 of 5 www.sstsensing.com