Mechanical pressure switches Liquids and gases. Pressure switches and vacuum switches with stainless steel sensors (1.4571)

Similar documents
Mechanical pressure switches Liquids and gases. Pressure switches and vacuum switches with stainless steel sensors (1.4571)

Mechanical pressure switches Liquids and gases. Negative pressure switches (vacuum switches)

Mechanical pressure switches Tested to ATEX 94/9/EC. II 2G Ex d e IIC T6 Gb II 1/2D Ex ta/tb IIIC T80 ºC Da/Db. SIL 2 according IEC

Mechanical pressure switches Tested to PE Directive 97/23/EC

Mechanical pressure switches Tested to PE Directive 97/23/EC. Maximum pressure limiters for liquid gas installations

Mechanical pressure switches Tested to PE Directive 97/23/EC

Mechanical pressure switches Tested to PE Directive EU/2009/142/EC. Pressure monitors for fuel gases

Mechanical pressure switches Tested to ATEX 94/9/EC. II 2G Ex d e IIC T6 Gb II 1/2D Ex ta/tb IIIC T80 ºC Da/Db

Pressure Switches Application Guideline

Mechanical pressure switches Tested to ATEX 94/9/EC. II 2G Ex d e IIC T6 Gb II 1/2D Ex ta/tb IIIC T80 ºC Da/Db

Tested to PE Directive 97/23 EC

Mechanical pressure switches

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Mechanical pressure switches Tested to ATEX 94/9/EC. II 2G Ex d e IIC T6 Gb II 1/2D Ex ta/tb IIIC T80 ºC Da/Db. SIL 2 according IEC

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

SCH. Mechanical Pressure Switches. for overpressure, vacuum pressure and differential pressure

Pressure Monitoring Flow Monitoring

Pressure Switches. Assembly and Operating Instructions. Important safety information!

Pressure Switch Pressure Limiter

Product Catalog. Pressure Switches. Pressure Transmitters. Thermostats. Temperature Transmitters. Solenoid Valves TÜV DVGW ATEX.

SITRANS P measuring instruments for pressure

OPTIBAR P 1010 C Technical Datasheet

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Pressure switch and Thermostat CAS

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Pressure switch Type BCP

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

[Instruments for vacuum measurement, checking and adjustment] 3

Pneumatic pressure switch 20DD

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

High-performance submersible pressure transmitter For level measurement Model LH-10

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Types and approvals. Page 1/6. Data Sheet

Gas density monitor With integrated transmitter Model GDM-100-TI

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.

Instruction Manual Contact Pressure Vacuum Gauge

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Pressure controls, differential pressure controls type RT

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure Transmitters 36 F-27839

Pressure Switch for gas and air GGAO-A4

Product Catalogue MINICOMB. Switches for Pressure and Vacuum

Pressure switch and Thermostat Type KPS

Pressure switch KP-E. Data sheet

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pressure Switch for gas and air

Pressure Switch for gas and air

Pressure switch, Differential pressure switch and Thermostat RT-E

Product information. Pressure. Pressure switches Pressure transmitters CERTIFIED ISO 9001 ISO DVGW TÜV

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Pilot valves for pilot operated servo valves

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Pressure switch and Thermostat KPS

Product Catalogue. P-SERIES Pressure Gauges

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Torque Tube TB300 Digital Transmitters

Pressure transmitters EMP 2

Data sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782

How to specify a product. Process Sensors and Mechanical Instruments

Pressure switches and thermostats, type KPS

VACUUM REGULATORS CONTENTS

ATM.1ST/Ex - High Precision Transmitter

9700 Transmitter Submersible hydrostatic level transmitter

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Model range*1) Switching pressure difference

4/2 way Pneumatic Solenoid Valve

Technical Data. General specifications. Rated operating distance s n 5 mm

High-performance submersible pressure transmitter For level measurement Model LH-20

GA24 Technical Datasheet

High-performance submersible pressure transmitter For level measurement Model LH-20

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

INSTRUCTION MANUAL Pressure Relief Device LPT

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pressure measurement. Pressure gauges

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Expert Hydrostatic Level Transmitters

ATM/Ex - Analog Pressure Transmitter

Monitoring device NTS 30

ATM.ECO/IS - Analog Transmitter with Temperature compensation

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Technical Data Sheet T 2025

Compact pressure switches for gas and air

Pressure Measurement Single-range transmitters for general applications

Pressure switch for gas and air

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Technical Data. General specifications. Rated operating distance s n 2 mm

Pressure Measurement Single-range transmitters for general applications

Transcription:

DNS3-201 Technical data Pressure connection External thread G 1/2 (pressure gauge connection) according to DIN 16 288 and internal thread G 1/4 according to ISO 228 Part 1. Switching device Robust housing (200) made of seawater resistant die cast aluminium GD Al Si 12. Protection class IP 54, in vertical position. Pressure sensor materials Pressure bellows and all parts in contact with medium. X 6 Cr Ni Mo Ti 17122 Material no. 1.4571 Mounting position Vertically upright and horizontal. Max. ambient temperature at switching device 25 +70 C. Max. medium temperature The maximum medium temperature at the pressure sensor must not exceed the permitted ambient temperature at the switching device. Temperatures may reach 85 C for short periods. Higher medium temperatures are possible provided the above limit values for the switching device are ensured by suitable measures (e.g. siphon). Mounting Directly on the pressure line (pressure gauge connection) or on a flat surface with two 4 mm Ø screws. Switching pressure Adjustable from outside with screw driver. Switching differential For values see Product Summary. Contact arrangement Single pole change over switch. Switching 250 VAC 250 VDC 24 VDC capacity (ohm) (ind) (ohm) (ohm) Normal 8 A 5 A 0.3 A 8 A Plastic coating The diecast aluminium housing in GD Al Si is chromated and stove enamelled with resistant plastic. Corrosion tests with 3% saline solution and 30 temperature changes from +10 to +80 C showed no surface changes after 20 days. Liquids and gases DNS/VNS Pressure switches and vacuum switches with stainless steel sensors (1.4571) Pressure switches of the DNS series are suitable for monitoring and controlling pressures in chemical plants, process engineering and any situation where the pressure of aggressive liquids and gases must be monitored. SIL 2 according IEC 61508-2 Product Summary s Protection Class: IP 54 41 All components of the sensor system are made of highquality stainless steel (1.4571) and welded using the latest methods without filler metals. The pressure sensor is gasket free plasma welded. Type Setting range Switching Max. Dimendifferential permissible sioned (mean values) pressure drawing Switching differential not adjustable page 25 + 26 VNS301-201 -250 +100 mbar 45 mbar 3 bar VNS111-201 -1* +0.1 bar 50 mbar 6 bar DNS025-201 0.04 0.25 bar 30 mbar 6 bar 1 + 15 DNS06-201 0.1 0.6 bar 40 mbar 6 bar DNS3-201 0.2 2.5 bar 0.1 bar 16 bar DNS6-201 0.5 6 bar 0.15 bar 16 bar 1 + 18 DNS10-201 1 10 bar 0.3 bar 16 bar DNS16-201 3 16 bar 0.5 bar 25 bar 1 + 16 Switching differential adjustable VNS111 203 1* +0.1 bar 90 550 mbar 6 bar DNS025 203 0.04 0.25 bar 60 300 mbar 6 bar 1 + 15 DNS06 203 0.1 0.6 bar 80 400 mbar 6 bar DNS3 203 0.2 2.5 bar 0.15 1.5 bar 16 bar DNS6 203 0.5 6 bar 0.25 2.0 bar 16 bar 1 + 18 DNS10 203 1 10 bar 0.45 2.5 bar 16 bar DNS16 203 3 16 bar 0.8 3.5 bar 25 bar 1 + 16 * At very high vacuums, close to the theoretical maximum of 1 bar, the switch may not be usable in view of the special conditions of vacuum engineering. However, the pressure switch itself will not be damaged at maximum vacuum. Calibration The DNS and VNS series are calibrated for falling pressure. This means that the adjustable switching pressure on the scale corresponds to the switching point at falling pressure. The reset point is higher by the amount of the switching differential. (See also page 27, 1. Calibration at lower switching point). -DNS/VNS see page 66

42 Liquids and gases DNS/VNS Pressure and vacuum switches with stainless steel sensors (1.4571) DNS6-351 Chemical version (switching housing with surface protection) Pressure switches of the DNS series are suitable for monitoring and controlling pressures in chemical plants, process engineering and any situation where the pressure of aggressive liquids and gases must be monitored. All components of the sensor system are made from highquality stainless steel (1.4571) and welded using the latest methods without filler metals. The pressure sensor is gasket free plasma welded. SIL 2 according IEC 61508-2 Technical data Pressure connection External thread G 1/2" (pressure gauge connection) according to DIN 16 288 and internal thread G 1/4" according to ISO 228 Part 1 Switching device Robust housing (300) made of seawaterresistant die cast aluminium GD Al Si 12 Protection class IP 65, in vertical position Pressure sensor materials Mounting position Pressure bellows and all parts in contact with medium X 6 Cr Ni Mo Ti 17122 Material no. 1.4571 Vertically upright and horizontal Max. ambient temperature at switching device 25 to +70 C Max. medium temperature Plastic coating The maximum medium temperature at the pressure sensor must not exceed the permitted ambient temperature at the switching device. Temperatures may reach 85 C for short periods. Higher medium temperatures are possible provided the upper limit at the switching device is ensured by suitable measures (e.g. siphon). The die cast aluminium housing in GD Al Si is chromated and stove-enamelled with resistant plastic. Corrosion tests with 3% saline solution and 30 temperature changes from +10 to +80 C showed no surface changes after 20 days Contact arrangement Single pole change over switch Type Setting range Switching Max. Dimendifferential permissible sioned (mean value) pressure drawing Hysteresis not adjustable page 25 + 26 VNS301-351 -250 +100 mbar 45 mbar 3 bar VNS111-351 -1* +0,1 bar 50 mbar 6 bar DNS025-351 0,04 0,25 bar 30 mbar 6 bar 2 + 15 DNS06-351 0,1 0,6 bar 40 mbar 6 bar DNS1-351 0,2 1,6 bar 60 mbar 6 bar DNS3-351 DNS10-351 0,2 2,5 1 10 bar bar 0,1 bar 0,3 bar 16 bar 16 bar DNS6-351 DNS16-351 0,5 6 3 16 bar bar 0,15 bar 0,5 bar 16 bar 25 bar 2 + 18 2 + 16 * At very high vacuums, close to the theoretical maximum of 1 bar, the switch may not be usable in view of the special conditions of vacuum engineering. However, the pressure switch itself will not be damaged at maximum vacuum. Calibration The DNS and VNS series are calibrated for falling pressure. This means that the adjustable switching pressure on the scale corresponds to the switching point at falling pressure. The reset point is higher by the amount of the switching differential. (See also page 27, 1. Calibration at lower switching point). Switching 250 VAC 250 VDC 24 VDC capacity (ohm) (ind) (ohm) (ohm) Normal 8 A 5 A 0.3 A 8 A DNS/VNS see page 66 s Protection Class: IP 65

Technical features / Advantages Technical features / Advantages Diecast aluminium housing IP 54 or IP 65 version also available Wall mounting or directly on the pressure line Switching element (microswitch) Lead sealable setpoint adjustment Setting spindle locking element Terminal connection or plug connection to DIN EN175301 Form A Stainless steel sensor housing Stainless steel bellows with internal stop Pressure connection G 1/2" external G 1/4" internal Centring pin 19

20 Definitions Definitions Pressure data Overpressure Vacuum Absolute pressure Pressure over the relevant atmospheric pressure. The reference point is atmospheric pressure. Pressure under the relevant atmospheric pressure. The reference point is atmospheric pressure. Overpressure relative to absolute vacuum. Differential pressure Difference in pressure between 2 pressure measuring points. Relative pressure Overpressure or vacuum relative to atmospheric pressure. Pressure data in all FEMA documents refers to relative pressure. That is to say, it concerns pressure differentials relative to atmospheric pressure. Overpressures have a positive sign, vacuums a negative sign. Permissible working pressure (maximum permissible pressure) The maximum working pressure is defined as the upper limit at which the operation, switching reliability and water tightness are in no way impaired (for values see Product summary). Bursting pressure (test pressure) Type-tested products undergo a pressure test certified by TÜV affirming that the bursting pressure reaches at least the values mentioned in the Product summary. During the pressure tests the measuring bellows are permanently deformed, but the pressurized parts do not leak or burst. The bursting pressure is usually a multiple of the permissible working pressure. Setting range Pressure range in which the cutoff pressure can be set with the setting spindle. Pressure units Unit bar mbar Pa kpa MPa (psi) Ib/m 2 1 bar 1 1000 10 5 100 0.1 14.5 1 mbar 0.001 1 100 0.1 10-4 0.0145 1 Pa 10-5 0.01 1 0.001 10-6 1.45 10-4 1 kpa 0,01 10 1000 1 0.001 0,145 1 MPa 10 10 4 10 6 1000 1 145 In FEMA documents pressures are stated in bar or mbar. Pressure data for a pressure switchbased on the example of DWR625: Setting range: 0.5-6 bar Perm. working pressure: 20 bar Bursting pressure: >100 bar Important: All pressure data refers to overpressures or vacuums relative to atmospheric pressure. Overpressures have a positive sign, vacuums a negative sign.

Maximum pressure monitoring RSP = SP xd Minimum pressure monitoring RSP = SP + xd Definitions Definitions Switching differential The switching differential (hysteresis) is the difference in pressure between the switching point (SP) and the reset point (RSP) of a pressure switch. Switching differential tolerances occur due to tolerances in the microswitches, springs and pressure bellows. Therefore the data in the product summaries always refers to average values. In the case of limiter functions the switching differential has no significance, as one is only interested in the switching point at which cutoff occurs, not the reset point. For a controller function, i. e. in the case of pressure switches used to switch a burner, pump etc. on and off, a pressure switch with an adjustable switching differential should be chosen. The switching frequency of the burner or pump can be varied by changing the switching differential. Adjustable switching differential/ calibration In the case of pressure switches with adjustable switching differential, the hysteresis can be set within the specified limits. The switching point (SP) and reset point (RSP) are precisely definable. When setting the pressure switch, the switching differential situation and the type of factory calibration must be taken into account. Some pressure switches (e.g. minimum pressure monitors of the DCM series) are calibrated under "falling" pressure, i.e. switching under falling pressure takes place at the scale value with the switching differential being above it. The device switches back at scale value + switching differential. If the pressure switch is calibrated under rising pressure, switching takes place at the scale value and the device switches back at scale value - switching differential (see direction of action). The calibration method is indicated in the data sheets. Direction of action In principle, any pressure switch can be used for both maximum pressure and minimum pressure monitoring. This excludes pressure limiters, whose direction of action (maximum or minimum) is predefined. The only thing to remember is that the scale reading may deviate by the amount of the switching differential. See example at bottom left: The scale value is 2.8 bar. Maximum pressure monitoring With rising pressure, switching takes place once the preset switching pressure is reached (SP). The reset point (RSP) is lower by the amount of the switching differential. Minimum pressure monitoring With falling pressure, switching takes place once the preset switching pressure is reached (SP). The reset point (RSP) is higher by the amount of the switching differential. Direction of action in vacuum range It is particularly important to define the direction of action in the vacuum range. Rising does not mean a rising vacuum, but rising pressure (as viewed from absolute "0"). "Falling" pressure means a rising vacuum. For example: Vacuum switch set to -0.6 bar falling means: Switching (SP) takes place under falling pressure (rising vacuum) at -0.6 bar. The reset point is higher by the amount of the switching differential (e.g. at -0.55 bar). Setting a pressure switch 21 To define the switching point of a pressure switch exactly, it is necessary to determine the direction of action in addition to the pressure. "Rising" means that switching takes place at the set value when the pressure rises. The reset point is then lower by the amount of the switching differential. "Falling" means exactly the opposite. Please note when specifying the setting of a pressure switch: In addition to the switching point it is also necessary to specify the direction of action (falling or rising). Example for selection of a pressure switch: A pump is to be turned on at 2.8 bar and off again at 4.2 bar. Chosen type: DCMV6 according to data sheet DCM. Setting: Scale pointer to 2.8 bar (lower switching point). Switching differential to 1.4 bar (set according to pressure gauge). Cutoff point: 2.8 bar +1.4 bar = 4.2 bar.

22 General description Operating mode The pressure prevailing in the sensor housing (1) acts on the measuring bellows (2). Changes in pres sure lead to movements of the measuring bellows (2) which are transmitted via a thrust pin (4) to the connecting bridge (5). The connecting bridge is frictionlessly mounted on hardened points (6). When the pressure rises the connecting bridge (5) moves upwards and operates the microswitch (7). A counter-force is provided by the spring (8), whose pre-tension can be modified by the adjusting screw (9) (switching point adjustment). Turning the setting spindle (9) moves the running nut (10) and modifies the pre-tension of the spring (8). The screw (11) is used to calibrate the microswitch in the factory. The counter pressure spring (12) ensures stable switching behaviour, even at low setting values. 1 = Pressure connection 2 = Measuring bellows 3 = Sensor housing 4 = Thrust pin 5 = Connecting bridge 6 = Pivot points 7 = Microswitch or other switching elements 8 = Setting spring 9 = Setting spindle (switching point adjustment) 10 = Running nut (switching point indicator) 11 = Microswitch calibration screw (factory calibration) 12 = Counter pressure spring Pressure sensors Apart from a few exceptions in the low-pressure range, all pressure sensors have measuring bellows, some made of copper alloy, but the majority of high-quality stainless steel. Measured on the basis of permitted values, the measuring bellows are exposed to a minimal load and perform only a small lifting movement. This results in a long service life with little switching point drift and high operating reliability. Furthermore, the stroke of the bellows is limited by an internal stop so that the forces resulting from the overpressure cannot be transmitted to the switching device. The parts of the sensor in contact with the medium are welded together without filler metals. The sensors contain no seals. Copper bellows, which are used only for low pressure ranges, are soldered to the sensor housing. The sensor housing and all parts of the sensor in contact with the medium can also be made entirely from stainless steel 1.4571 (DNS series). Precise material data can be found in the individual data sheets. Pressure connection The pressure connection on all pressure switches is executed in accordance with DIN 16288 (pressure gauge connection G 1/2A). If desired, the connection can also be made with a G 1/4 internal thread in accordance with ISO 228 Part 1. Maximum screw-in depth on the G 1/4 internal thread = 9 mm. Centring pin In the case of connection to the G 1/2 external thread with seal in the thread (i.e. without the usual stationary seal on the pressure gauge connection), the accompanying centring pin is not needed. Differential pressure switches have 2 pressure connections (max. and min.), each of which are to be connected to a G 1/4 internal thread.

Switch housing Pressure connection Switching function and connection scheme (applies only to version with microswitch) Switching capacity (for microswitches with a silver contact) Mounting position Protection class (in vertical position) Electrical connection Cabel entry Ambient temperature Switching point Hysteresis Medium temperature Relative humidity Vacuum Repetition accuracy of switching points Vibration resistance Mechanical durability (pressure sensor) Electronical durability (microswitch) Isolation values Oil and grease-free Principal technical data Principal technical data Valid for all pressure switches of the DCM, DNM, DWAM, DWAMV, SDBAM, VCM, VNM, DNM, DWR, DGM, DNS and DDCM series that have a microswitch. The technical data of type tested units may differ slightly (please refer to particular type sheet). Standard version Plug connection Terminal connection 200 300 Die cast aluminium GDAISi 12 G 1/2" external thread (pressure gauge connection) and G 1/4" internal thread. 1/4" internal thread for DDCM differential pressure switches Floating changeover contact. With rising pressure single pole switching from 3 1 to 3 2. 8 A at 250 VAC 5 A at 250 VAC inductive 8 A at 24 VDC 0.3 A at 250 VDC min. 10 ma, 12 VDC Preferably vertical (see technical data sheet) IP 54 Plug connection Pg 11 25 to +70 C (exceptions: DWAM, DWAMV, SDBAM series 20 to +70 C DGM and FD series: 25 to +60 C DCM4016, 4025, 1000, VCM4156: 15 to +60 C) Adjustable using the setting spindle Adjustable or not adjustable (see Product Summary) Max. 70 C, briefly 85 C 15 to 95 % (non-condensing) Die cast aluminium GDAISi 12 G 1/2" external thread (pressure gauge connection) and G 1/4" internal thread. 1/4" internal thread for DDCM differential pressure switches Floating changeover contact. With rising pressure single pole switching from 3 1 to 3 2 8 A at 250 VAC 5 A at 250 VAC inductive 8 A at 24 VDC 0.3 A at 250 VDC min. 10 ma, 12 VDC Vertical IP 65 Terminal connection M 16 x 1.5 25 to +70 C (exceptions: DWAM, DWAMV, SDBAM series 20 to +70 C DGM and FD series: 25 to +60 C DCM4016, 4025, 1000, VCM4156: 15 to +60 C) Adjustable using the setting spindle once the switch housing cover is removed Adjustable or not adjustable (see Product Summary) Max. 70 C, briefly 85 C 15 to 95 % (non-condensing) Higher medium temperatures are possible provided the above limits for the switching device are ensured by suitable measures (e.g. siphon). All pressure switches can operate under vacuum. This will not damage the device (exception DCM1000). < 1 % of the working range (for pressure ranges > 1 bar). No significant deviations up to 4 g. With sinusoidal pressure application and room temperature, 10 x 10 6 switching cycles. The expected life depends to a very large extent on the type of pressure application, therefore this figure can serve only as a rough estimate. With pulsating pressure or pressure impacts in hydraulic systems, pressure surge reduction is recommended. 100.000 switching cycles at nominal current 8 A, 250 VAC. A reduced contact load increases the number of possible switching cycles. Overvoltage category III, contamination class 3, reference surge voltage 4000 V. Conformity to DIN VDE 0110 is confirmed. The parts of all pressure switches in contact with the medium are oil and grease free (except the HCD and DPS series). The sensors are hermetically sealed and contain no seals (also see ZF1979, special packing). 23

24 Principal technical data Principal technical data Valid for all pressure of the DCM, VCM, VNM, DNM, DWR, DGM, DNS, DWAM, DWAMV and DDCM series that have a microswitch. The technical data of type-tested units may differ slightly (please refer to particular type sheet). Ex-i-version version (Ex-d) 500 700 Switch housing Pressure connectionn Switching function and connection scheme (applies only to version with microswitch) Switching capacity Mounting position Protection class (in vertical position) Explosion protection Code EC Type Examination Certificate Number Electrical connection Cabel entry Ambient temperature Medium temperature Relative humidity Switching point Hysteresis Vacuum Repetition accuracy of switching points Vibration resistance Mechanical durability (pressure sensor) Electronical durability (microswitch) Isolation values Oil and grease-free Die cast aluminium GDAISi 12 G 1/2" external thread (pressure gauge connection) and G 1/4" internal thread. 1/4" internal thread for DDCM differential pressure switches Floating changeover contact. With rising pressure single pole switching from 3 1 to 3 2 max.: 100mA, 24VDC min.: 2mA, 5VDC Vertical IP 65 II 1/2G Ex ia IIC T6 Ga/Gb II 1/2D Ex ia IIIC T80 C IBExU12ATEX1040 Terminal connection M 16 x 1.5 25 to +60 C (exceptions: DWAM series 20 to +60 C DGM and FD series: 25 to +60 C DCM4016, 4025, 1000, VCM4156: 15 to +60 C) Max. 60 C 15 to 95 % (non-condensing) After removing switch housing cover Not adjustable Die cast aluminium GDAISi 12 G 1/2" external thread (pressure gauge connection) and G 1/4" internal thread. 1/4" internal thread for DDCM differential pressure switches Floating changeover contact. With rising pressure single pole switching from 3 1 to 3 2 3 A at 250 VAC 2 A at 250 VAC inductive 3 A at 24 VDC 0.1 A at 250 VDC min. 2 ma, 24 VDC Vertical IP 65 II 2G Ex d e IIC T6 Gb II 1/2D Ex ta/tb IIIC T80 C Da/Db IBExU12ATEX1040 Terminal connection M 16 x 1.5 20 to +60 C Max. 60 C 15 to 95 % (non-condensing) After removing switch housing cover Not adjustable Higher medium temperatures are possible provided the above limits for the switching device are ensured by suitable measures (e.g. siphon). All pressure switches can operate under vacuum. This will not damage the device. < 1 % of the working range (for pressure ranges > 1 bar). No significant deviations up to 4 g. With sinusoidal pressure application and room temperature, 10 x 10 6 switching cycles. The expected life depends to a very large extent on the type of pressure application, therefore this figure can serve only as a rough estimate. With pulsating pressure or pressure impacts in hydraulic systems, pressure surge reduction is recommended. 100.000 switching cycles at nominal current 8 A, 250 VAC. A reduced contact load increases the number of possible switching cycles. Overvoltage category III, contamination class 3, reference surge voltage 4000 V. Conformity to DIN VDE 0110 is confirmed. The parts of all pressure switches in contact with the medium are oil and grease free (except the HCD and DPS series). The sensors are hermetically sealed and contain no seals (also see ZF1979, special packing).

48.5 45.5 37 76.5 56 8.2 4.8 42.3 32.5 SW24 8.2 60 46±0.2 4.8 G1/2A 112 72 46 60±0.1 102.6 6 G1/4 Dimensioned drawings Dimensioned drawings of switch housings (mm) 1 Housing 200 (plug connection) 2 Housing 300 (terminal connection) Pg11 DIN EN 175301 3 Housing 500 (terminal connection Ex-i) 4 33.5 3.5 20 45 76.5 36.5 67 76.5 56 56 42.3 32.5 32.5 8.2 11.1 8.2 4.8 4.8 72 46 60±0.1 72 46 60±0.1 102.6 Housing 700 (terminal connection Ex-d) Dimensioned drawings of pressure sensors (mm) 10 11 26 20 3.5 102.6 Ø6 G1/4 G1/2 132 SW22 33.5 33.5 45 45 76.5 56 25

26 Dimensioned drawings Dimensioned drawings of pressure sensors (mm) 12 2 13 Ø69 64 82 SW22 20 hex22 20 G1/4 G1/2 30 3.5 Ø6 G1/4 G1/2 14 15 he41 61 20 50 hex22 20 3.5 Ø6 G1/4 G1/2 3.5 Ø6 G1/4 G1/2 16 19 hex Dimensioned drawing hex (mm) 90 55 G1/4 20 40 16 22 17 24 18 30 19 32 3.5 Ø6 G1/4 G1/2 20 11max 21 21 44 74 G1/4 70 hex 41 102

Clockwise: lower switching pressure Anticlockwise: higher switching pressure Direction of action of setting spindle Clockwise: greater difference Anticlockwise: smaller difference With pressure switches from the DWAMV and DWR...-203 series, the direction of action of the differential screw is reversed. Setting instructions Setting instructions Factory calibration of pressure switches In view of tolerances in the characteristics of sensors and springs, and due to friction in the switching kinematics, slight discrepancies between the setting value and the switching point are unavoidable. The pressure switches are therefore calibrated in the factory in such a way that the setpoint adjustment and the actual switching pressure correspond as closely as possible in the middle of the range. Possible deviations are equally distributed on both sides. The device is calibrated either for falling pressure (calibration at lower switching point) or for rising pressure (calibration at higher switching point), depending on the principal application of the type series in question. Where the pressure switch is used at other than the basic calibration, the actual switching point moves relative to the set switching point by the value of the average switching differential. As FEMA pressure switches have very small switching differentials, the customer can ignore this where the switching pressure is set only roughly. If a very precise switching point is needed, this must be calibrated and checked in accordance with normal practice using a pressure gauge. 1. Calibration at lower switching point 2. Calibration at upper switching point Setpoint x S corresponds to the lower switching Setpoint x S corresponds to the upper switching point, the upper switching point x O is higher point, the lower switching point x U is lower by the amount of the switching differential x d. by the amount of the switching differential x d. The chosen calibration type is indicated in the technical data for the relevant type series. Setting switching pressures Prior to adjustment, the securing pin above the scale must be loosened by not more than 2 turns and retightened after setting. The switching pressure is set via the spindle. The set switching pressure is shown by the scale. To set the switching points accurately it is necessary to use a pressure gauge. Changing the switching differential (only for switching device with suffix "V", ZF203) By means of setscrew within the spindle. The lower switching point is not changed by the differential adjustment; only the upper switching point is shifted by the differential. One turn of the differential screw changes the switching differential by about 1/4 of the total differential range. The switching differential is the hysteresis, i.e. the difference in pressure between the switching point and the reset point. Lead sealing of setting spindle (for plug connection housing 200 only) The setting spindle for setting the desired value and switching differential can be covered and sealed with sealing parts available as accessories (type designation: P2) consisting of a seal plate and capstan screw. The sealing parts may be fitted subsequently. The painted calibration screws are likewise covered. 27

28 Pressure switch with locking of switching state (reclosing lockout) Pressure switch with switching state locking (reclosing lock out) In the case of limiter functions, the switching state must be retained and locked, and it may be unlocked and the system restarted only after the cause of the safety shutdown has been eliminated. There are two ways of doing this: 1. Mechanical locking inside the pressure switch Instead of a microswitch with automatic reset, limiters contain a "bi-stable" microswitch. If the pressure reaches the value set on the scale, the microswitch trips over and remains in this position. The lock can be released by pressing the unlocking button (identified by a red dot on the scale side of the switching device). The lock can operate with rising or falling pressure, depending on the version. The device can only be unlocked when the pressure has been reduced (or increased) by the amount of the predefined switching differential. When selecting a pressure limiter, it is necessary to distinguish between maximum and minimum pressure monitoring. Ex-d versions cannot be equipped with internal locking. Maximum pressure limitation Switching and interlocking with rising pressure. Additional function ZF205. Minimum pressure limitation Switching and interlocking with falling pressure. Additional function ZF206. Connection of control Connection of control current circuit to current circuit to terminals 1 and 3. terminals 2 and 3. 2. External electrical interlock in the control cabinet (suggested circuits) A pressure monitor (microswitch with automatic reset) can also be used as a limiter if an electrical interlock is added. For pressure limitation in steam and hot water boilers, an external interlock is only permitted if it has been ascertained that the pressure monitor is "of special construction". Maximum pressure limitation with external interlock Minimum pressure limitation with external interlock Where the above lock circuit is used, the requirements of DIN 57 116/VDE 0116 are met if the electrical equipment (such as contactors or relays) of the external interlock circuit satisfy VDE 0660 or VDE 0435.

Explanation of type designations type codes Explanation of type designations type codes The type designations of FEMA pressure switches consist of a combination of letters followed by a number denoting the setting range. Additional functions and version variants are indicated by an extra code which is separated from the basic type by a hyphen. Ex-versions (explosion protection Ex-d) are identified by the prefix "Ex" in front of the type designation. Basic version With additional function Ex-version (based on the example of DCM series) DCMXXX DCMXXX-YYY Ex-DCMXXX DCM XXX YYY Ex Switch housing version Series code (e. g. DCM) Codes for pressure range Code for additional function Code for Ex-version DCMXXX Basic version with plug connection housing DCMXXX-2... Basic version with plug connection housing DCMXXX-3... Terminal connection housing (300) Ex-DCMXXX Ex-d switching device (700) DCMXXX-5... Ex-i version (500) Which additional function fits with which pressure switch? Plug connection, 200 series Additional function ZF Terminal connection, 300/500 series Additional function ZF 203 213 217 301 307 513 574 575 351 576 577 DCM/VCM 1 1 1 VNM/DNS/VNS DWAM DDCM DWR DGM available 1 except DCM4016, DCM4025, VCM4156 and DCM1000 Combination of several additional functions is not possible! Ex-versions (Ex-d) can only be supplied in basic form. Additional functions are not possible. 29

30 Additonal functions / Connecting schemes Pressure switches and pressure monitors Additional functions / Connection schemes Plug connection, Terminal connection, Connection scheme 200 series (IP 54) 300 series (IP 65) Standard version (plug connection) Micro switch, single pole switching, switching differential not adjustable Terminal connection housing (300) ZF301 Unit with adjustable switching differential ZF203 Maximum pressure limiter with reclosing lockout Interlocking with rising pressure see DWR series ZF205 Minimum pressure limiter with reclosing lockout Interlocking with falling pressure see DWR series ZF206 Note to non-available items: In our article master all the possible technical combinations are not created. Therefore we recommend the previous request for clarification and selection of an alternative solution.

Two micro switches, switching in parallel or in succession. Fixed switching differential, only possible with terminal connection housing. State the switching differential (not possible with all pressure switches). Two micro switches, 1 plug ZF217 * switching in succession, no adjustable switching differential. State the switching scheme * (not possible with all pressure switches). Gold-plated silver contact, single pole switching (not available with adjustable switching differential). Switching capacity: max. 24 VDC, 100 ma, min. 5 VDC, 2 ma Switch housing with surface protection (chemical version) * Connection schemes for switching schemes, see page 36. Please state interval when ordering! Example for ordering: DCM10-217A-S. Additional text: switching scheme A4 Additonal functions / Connecting schemes Plug connection Terminal connection Connection scheme 200 series (IP 54) 300 series (IP 65) ZF213 ZF307 ZF351 Connection scheme selection, see page 36 Note to non-available items: In our article master all the possible technical combinations are not created. Therefore we recommend the previous request for clarification and selection of an alternative solution. Example for ordering: DCM 6 205 Code of additional function (e.g. maximum limiter) Code for pressure range Sensor system How to order: Pressure switch DCM6-205 or DCM6 with ZF205 31

32 Additonal functions / Connecting schemes Pressure switches and pressure monitors Additional functions for Ex-i-equipment Housing (500) with terminal connection (IP 65), "blue" cable entry and terminals. Also available with resistor combination for line break and short-circuit monitoring (with isolating amplifier).! Important: All pressure switches with the ZF5 additional functions listed here can only be operated in combination with a suitable isolating amplifier. DWAM6-576 i Additional information: Our pressure switches and thermostats are considered to be "simple electrical equipment" within the meaning of standard EN60079-11: 2007. Testing is not mandatory for this type of equipment. i ATEX-Certificate: please see page 10 13 Additional functions for Ex-equipment II 1/2G Ex ia IIC T6 Ga/Gb II 1/2D Ex ia IIIC T80 C Connection scheme Gold plated contact single pole switching, fixed hysteresis, not adjustable Switching capacity: max. 24 VDC, 100 ma, min. 5 VDC, 2 ma For the power supply circuit: U i 24 V DC C i 1 nf I i 100 ma L i 100 µh ZF513 Versions with resistor combination for line break and short-circuit monitoring in control current circuit, see DBS series, pages 54 56: For the power supply circuit: U i 14 V DC R i 1500 Ohm C i 1 nf L i 100 µh Normally closed contact with resistor combination, for minimum pressure monitoring, gold plated contact, plastic-coated housing (chemical version). ZF574 Normally closed contact with reclosing lockout and resistor combination, for minimum pressure monitoring, plastic coated housing (chemical version). Normally closed contact with resistor combination, for maximum pressure monitoring, gold plated contact, plastic coated housing (chemical version). ZF575 ZF576 see DBS series pages 54 56 Normally closed contact with reclosing lockout and resistor combination, for maximum pressure monitoring, plastic-coated housing (chemical version). ZF577 Note to non available items: In our article master all the possible technical combinations are not created. Therefore we recommend the previous request for clarification and selection of an alternative solution.

Service functions Service functions Devices with service functions will be produced according to the customer s specifications. The system requires that these product combinations are identified in such a way as to prevent any possibility of confusion. These combinations are characterised by a product code with the suffix "-S" on the packaging label as well as separate labels with barcodes for each service function. Service functions Plug connection Terminal connection Ex-i / 200 series 300 series Ex-d Adjustment according to customer s instruction: - one switching point ZF1970* ZF1970* ZF1970* - two switching points or defined switching differential ZF1972* ZF1972* Adjustment and lead sealing according to customer s instruction: - one switching point ZF1971* - two switching points or defined switching differential ZF1973* Labelling of units according to customer s ZF1978 ZF1978 ZF1978 instruction with sticker Special packing for oil and grease-free storage ZF1979 ZF1979 ZF1979 Test reports according to EN 10 204 - Certificate 2.2 based on non specific specimen test WZ2.2 WZ2.2 WZ2.2 - Inspection test certificate 3.1 based on specific test AZ3.1B1 AZ3.1B1 AZ3.1B1 - Inspection test certificate for FV separating diaphragms AZ3.1-V AZ3.1-V AZ3.1-V * Switching point adjustment: Please specify switching point and direction of action (rising or falling pressure). Service functions are available for the following type series (including Ex-versions): Pressure switches: DCM, DNM, DNS, VNS, VCM, VNM, DDCM, DWR, DWAM, DWAMV, SDBAM, DGM, FD Ordering devices with service functions Example: Ordering 1 DCM6, set at 4 bar rising, identified with code PSH008 as requested by the customer and acceptance test certificate 3.1. The order confirmation contains: 1 DCM6-S ("S" is need for factory = following lines belong to this item) 1 ZF1970: set to 4 bar rising 1 ZF1978: PSH008 1 AZ3.1B1 Included items: Labels with barcodes on the packaging: DCM6-S ZF1970: set to 4 bar rising ZF1978: PSH008 AZ3.1B1 Pack contents: 1 DCM6 (without "S" suffix) marked 1 ZF1970: set to 4 bar rising 1 ZF1978: PSH008 1 AZ3.1 B1 will be sent by extra post 1 Installation and operating instructions 33

For pressure dependent control of automatic expansion valves and pressure holding devices Minimum and maximum pressure monitoring in a nitrogen line S2 type series S2 type series Examples of use for two stage pressure switches Pressure monitoring and controlling can be greatly simplified by using pressure monitors with two built-in microswitches which can be made to operate one after the other under rising or falling pressure. For example, minimum and maximum pressure monitoring can be achieved with only one pressure switch, doing away with the need for a second pressure switch (including the cost of installation). Step switching, e.g. pressure-dependent control of a two-stage pump, is of course also possible using this special series. Example 1: 37 Requirement Pressure holding devices and automatic expansion valves usually have a gas cushion whose pressure must be kept constant within a certain range. If the pressure is too low, a compressor is switched on. If the pressure is too high, a solenoid valve must be opened to vent the gas. Between these two levels is a neutral zone, in which the compressor and the solenoid valve are at rest. Solution All pressure switches of types DCM, DNS, each with additional function ZF217 and switching scheme A 2, are suitable. All pressure ranges listed in the technical documents are possible. Example for ordering: see page 24 Switching function / connection scheme Switch I: With falling pressure, contact 1 2 closes (compressor on) With rising pressure, contact 1 2 opens (compressor off) Switch II: Example 2: With rising pressure, contact 2 3 closes (valve open) With falling pressure, contact 2 3 opens (valve closed). In between there is a neutral zone in which the compressor is not switched on and the solenoid coil is not energized (off position). Requirement In a process engineering system, the pressure in a nitrogen line has to be monitored. A green signal lamp indicates that the pressure in the line is between 2.2 and 2.6 bar. If the pressure goes below 2.2 bar or above 2.6 bar, the indicator lamp goes out and the system shuts down. Solution The first contact of a DCM3 307 pressure switch with 2 microswitches opens under falling pressure at 2.2 bar; the second microswitch opens under rising pressure at 2.6 bar. If the pressure is >2.2 bar or <2.6 bar, the circuit is closed via both microswitches and the signal lamp is lit.

34 S2 type series S2 type series Pressure switches with 2 microswitches - technical data FEMA pressure switches of the DCM (except DCM1000, DCM4016 and DCM4025), VCM (except VCM4156), VNM, DNS, VNS series can be equipped with 2 microswitches. This is not possible with any other type series or with Ex-versions. Technical data Standard equipment The standard equipment of every two stage pressure switch includes a switching device with 2 microswitches, both single pole switching. Switch I monitors the low pressure, switch II the higher pressure. The setting ranges indicated in the data sheets for the basic types apply to the two stage pressure switches as well. It should be noted that the switching differentials of the individual microswitches may not be exactly the same due to component tolerances. Switching difference (see table, page 35) The switching interval of the two microswitches is the difference (in bar or mbar) between the switching points of the two micro switches. Example for ZF307: When the pressure rises (e.g. 2.8 bar), a two stage pressure switch turns on a warning light, and if the pressure continues to rise (e.g. 3.2 bar) the system shuts down. The switching interval is 3.2-2.8 = 0.4 bar. The following applies to all versions: The switching interval remains constant over the whole setting range of the pressure switch. If the switching pressure setting is changed with the setting spindle, the switching interval does not change - the switching points are moved in parallel. Switching differential (see table page 35) The switching differential, i.e. the hysteresis of the individual micro switches, corresponds to the values of the relevant basic version referred to in the Product summary. In the case of two stage pressure switches, the switching differential of the individual micro switches is not adjustable. Versions Two stage pressure switches are available in three different versions, each identified by a ZF number. The versions differ in terms of their connection schemes and electrical connection types (terminal or plug connection). The applicable data sheet for the basic types contains the technical data for the two stage pressure switches. This includes all limits of use, such as temperature, maximum pressure, mounting position, protection class, electrical data etc. The principal dimensions are the same as for single-stage pressure switches with comparable pressure ranges and design features. Additional Switching difference Electrical Connection Ordering function between the two connection diagram information required micro switches ZF307 ZF217 Factory setting according to customer s instruction Switching difference fixed Adjustable via adjustment knobs I and II in accordance with "Switching difference" table Terminal connection (All terminals of both microswitches are accessible (6 terminals) Note on ordering additional function ZF217 Plug connection in accordance with DIN EN175301 (3-prong + earth conductor) Functionappropriate internal wiring in accordance with "Switching functions" table 2 x single pole switching Example selection in accordance with "Switching schemes" table, page 36. 1. Basic type with ZF 307 2. Switching points I and II, with direction of action in each case (rising or falling pressure) Example: DCM16-307 Switching point I: 10 bar falling Switching point II: 12 bar falling or switching interval only. 1. Basic type with ZF217 2. Switching scheme For example: DCM16-217/B 4 Since all values are adjustable within the specified limits, no further data is required. Switching scheme Switching device Ordering position Additional text A1 A DCM6-217A-S Switching scheme A1 A2 C DCM6-217C-S Switching scheme A2 A3 C DCM6-217C-S Switching scheme A3 A4 A DCM6-217A-S Switching scheme A4 B1 B DCM6-217B-S Switching scheme B1 B2 D DCM6-217D-S Switching scheme B2 B3 D DCM6-217D-S Switching scheme B3 B4 B DCM6-217B-S Switching scheme B4 C1 B DCM6-217B-S Switching scheme C1 C2 D DCM6-217D-S Switching scheme C2 C3 D DCM6-217D-S Switching scheme C3 C4 B DCM6-217B-S Switching scheme C4 D1 A DCM6-217A-S Switching scheme D1 D2 C DCM6-217C-S Switching scheme D2 D3 C DCM6-217C-S Switching scheme D3 D4 A DCM6-217A-S Switching scheme D4

S2 type series S2 type series (selection) ZF217 pressure switches with two microswitches and switching difference Switching difference of two stage pressure switches (ZF217, ZF307) Type series S2 ZF217 ZF307 Higher pressure Lower pressure min. switching difference max. switching difference (mean values) (ZF217) ZF217, ZF307 Type Factory default (parallel) switching scheme switching scheme switching scheme ZF307 A1/A3/B2/B4 A2/A4/C2/C4 B1/B3/D1/D3 C1/C3/D2/D4 + ZF 307 DCM06 40 mbar 165 mbar 190 mbar 140 mbar DCM025 20 mbar 140 mbar 160 mbar 120 mbar DCM1 40 mbar 240 mbar 280 mbar 200 mbar DCM3, DNS3-201 0,1 bar 0,65 bar 0,75 bar 0,55 bar DCM6, DNS6-201 0,15 bar 0,95 bar 1,2 bar 0,8 bar DCM10, DNS10-201 0,25 bar 1,6 bar 1,85 bar 1,35 bar DCM16, DNS16-201 0,3 bar 2,0 bar 2,3 bar 1,7 bar DCM25 0,6 bar 4,0 bar 4,6 bar 3,4 bar DCM40 0,9 bar 6,0 bar 6,9 bar 5,1 bar DCM63 1,3 bar 8,5 bar 9,8 bar 7,2 bar DNM025, DNS025-201 35 mbar 215 mbar 240 mbar 180 mbar VCM095 40 mbar 300 mbar 340 mbar 260 mbar VCM101 40 mbar 260 mbar 300 mbar 220 mbar VCM301 20 mbar 100 mbar 120 mbar 80 mbar VNM111, VNSM111-201 50 mbar 310 mbar 360 mbar 260 mbar Switching devices with adjustable switching difference Additional function ZF217 On switching devices with additional function ZF217, the switching differene is continuously adjustable via two adjustment knobs I and II accessible from outside. The maximum possible switching difference is stated in the "Switching difference" table. Turning adjustment knob I clockwise produces a lower switching point for microswitch I Turning adjustment knob II anticlockwise produces a higher switching point for microswitch II Adjustment knobs I and II have an internal stop to prevent the micro switches from being adjusted beyond the effective range. Adding together the adjustments on knobs I and II results in the switching difference between the two micro switches. Changes made with the setting spindle do not affect the switching difference. The switching difference remains constant over the whole setting range of the spindle. The two switching points are moved up or down in parallel. Recommended adjustment method for switching devices with ZF217 1. Set adjustment knobs I and II to their basic positions. Turn adjustment knob I anticlockwise as far as possible. Turn adjustment knob II clockwise as far as possible. 2. Adjust the setting spindle S by the scale to a value midway between the desired upper and lower switching points. 3. With pressure applied, set the lower switching point with adjustment knob I. 4. In the same way as in step 3, set the upper switching point with adjustment knob II. 5. If the desired upper and lower switching points cannot be reached, turn the setting spindle S in the appropriate direction and repeat steps 3 and 4. 35

36 S2 type series S2 type series Two stage pressure switches, switching schemes for ZF217 Function appropriate internal configuration of microswitches I and II, switching scheme selection table. The switch position shown corresponds to the pressureless state. On the horizontal axis is the switching function of microswitch I (A D); on the vertical axis is the switching function of microswitch II (1 4). At the intersection is the switching scheme which satisfies both conditions (e.g. A 2). Microswitch I (lower switching point) falling, close rising, close falling, open rising, open rising, open Microswitch II (upper switching point) falling, open rising, close falling, close Information required when ordering: As well as the basic type (e.g. DCM10) and the switching scheme (e.g. A 2), for factory setting it is also necessary to indicate the switching points and direction of action: Example: DCM10-217C-S, switching scheme: A2, Switch I: 6.5 bar falling, Switch II: 7.5 bar rising.