J800 HOPE BUOYANCY COMPENSATOR OWNER S MANUAL

Similar documents
LTS BCD USER GUIDE. Hollis (2014) Doc r01 (8/29/14)

BUOYANCY COMPENSATOR DEVICE OWNER S MANUAL

Travel Wing. Buoyancy Compensator User Instruction Manual

BUOYANCY COMPENSATOR DEVICE MANUAL

RG2200 BC Integrated Octopus

T3200 TransPlate Harness

SIDE 16 Sidemount System User Manual

B.C.D. Buoyancy Compensator Device User Manual

Katana Sidemount Harness USER GUIDE

ZEOS 28 ZEOS 38 HYDROS 40 HYDROS 50 READ CAREFULLY. YOUR COMFORT AND SAFETY IS WORTH MORE THAN 15 MINUTES.

ZEOS 28 ZEOS 38 HYDROS 40 HYDROS 50. User manual English

Note: For CE certification, this wing was tested with the T3000 TransPac Harness System.

READ CAREFULLY. YOUR COMFORT AND SAFETY IS WORTH MORE THAN 15 MINUTES.

Ocean Management Systems, Inc. P.O. Box 146, Montgomery, NY 12549

SMS75 HARNESS USER GUIDE

with SureLock OWNER'S MANUAL

SCUBATECH. User Instruction Manual. Buoyancy compensators. Range of models

SHERWOOD OWNER S MANUAL

fenzy x4 technical manual PN (orange) PN (black)

SHERWOOD PRO OWNER S MANUAL

RG3100 and RG3100Ice Regulator System

COPYRIGHT NOTICE WARNINGS, CAUTIONS AND NOTES

User Instruction Manual

Gemini Owner s Manual

Congratulations on the purchase of your new EDGE Buoyancy Compensator (BC).

Women's Buoyancy Compensator. Owner's Manual

AIR SOURCE. Owner's Manual

READ CAREFULLY. YOUR COMFORT AND SAFETY IS WORTH MORE THAN 15 MINUTES.

WSX Sidemount Owner s Manual

Wave TABLE OF CONTENTS. Copyright Notice. Weight Integration Features. Warnings, Cautions and Notes. Inflation Methods. Safety Information

BD Buoyancy Compensator

APPENDIX D. On-Site Fatality Investigation Checklists. Steven M. Barsky Marine Marketing & Consulting 2419 E. Harbor Blvd. #149 Ventura, CA USA

QUICK REFERENCE. Right Shoulder dump valve. Pull knob for right shoulder dump valve. Hide-away pocket flap. Rear dump valve (1 of 2)

Regulator Owner s Manual. Regulator Owner s Manual

BUOYANCY COMPENSATOR OWNERS MANUAL

Pearl TABLE OF CONTENTS. English. Copyright Notice

Rapid Diver System User's Manual

AP100 AUTO AIR. User Instruction Manual

Halcyon. Contour BC OWNER S MANUAL

Flathead VI Owner s Manual

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

R0001. Northern Diver. HYDRA Regulator Manual

NORTHERN DIVER PFD MANUAL

BC4300, BC4400 Buoyancy Compensator Wings. Product Description and Specifications REC EXP BC4300

SAFETY INFORMATION... 3 BASIC SETUP... 5 WEIGHT INTEGRATION FEATURES... 9 DONNING AND ADJUSTMENT PROCEDURES INFLATION METHODS...

32364B01 USER MANUAL DIVATOR RESCUE BC

OWNER S MANUAL. A Diver s Reserve Parachute

1 waterp wa r te o rp o r f o - of us us a a..com co m Waterproof Wetsuit Manual

WETSUIT OWNER S MANUAL

REGULATOR OWNER S GUIDE

Axiom TABLE OF CONTENTS. English. Copyright Notice

ADMINISTRATION GENERAL INFORMATION OCEANIC ADMINISTRATION FOR PRODUCT SERVICE PROCEDURES

Table of Contents 2 ATOMIC AQUATICS BC1 OWNERS MANUAL

Buoyancy Control Device

X-Tech CLV User Manual. English

WTX-D Buoyancy System

RG1200 Regulator System

NATIONAL (NATO) STOCK NUMBER: NSN

isup MANUAL THANK YOU FOR PURCHASING A KAHUNA isup, WE HOPE YOU HAVE MANY YEARS OF PADDLING ENJOYMENT.

Axiom i3 TABLE OF CONTENTS. English. Copyright Notice

SURFACE SUPPLIED HARNESS

Ambient Pressure Diving Ltd. Back Mounted Counterlungs. User Instruction Manual

RECOVERY VEST MANUAL

Leglifter. user instructions. Simple solutions for everyday independence

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Inflatable Stand Up Paddle Board Manual

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

ST53SD. Self Contained Breathing Apparatus. User Manual

ANNUAL SELF INSPECTION / SERVICING INSTRUCTION SHEET

Mangar ELK Instruction & Safety Manual

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

Inflatable Stretcher. Product Manual

Introduction. 2. Limited Lifetime Warranty. 3. Drysuit Guidelines.. 4. Responsible Drysuit Diving... 5

IMPORTANT SAFETY PRECAUTIONS! TABLE OF CONTENTS

Operation Manual Guillotine Cutter RC-5

80 Litre Suction Oil Drainer

CREWFIT 165 SPORT. self care and maintenance manual

In this manual; Warnings, Cautions and Notes calls your attention to information provided to help ensure your safety. Always dive safely.

STEALTH 2.0 Side Mount System

DIVATOR RS4 USER MANUAL

air/hydraulic nut riveter heavy-duty vacuum system

User Operation Manual and Safety Instructions

- Manufactured and tested in accordance with ADCI. - Each of the 9 D-rings has been tested to a breaking strength of 1000kg

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

117 West Washington Street Lake City, FL USA Phone (386) Fax (386)

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

Operating and maintenance manual Filter and reducing station Series / 1.0

SMA1060 INSTRUCTIONS FOR SELF INSPECTION SMA1061 MANUAL INFLATION SMA1062 AUTO INFLATION

WTX Buoyancy System TABLE OF CONTENTS. Mounting a Single or Twin Cylinder(s) Using Nuts and Bolts. Copyright Notice. Warnings, Cautions and Notes

Bimini Top, Bimini Top Plus for Jeep Wrangler Vehicles Items # , # and #

Sea Rebel Kayak Owner s Manual

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

STEALTH 2.0 TEC Side Mount System

T130/T131/T147. Economy Basket Stretcher with Lifting Kit

MODEL NUMBER: AS18-2 USER GUIDE

Pressure Relief Valve Instruction Manual

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

Owner s Guide. ElevateSUP.com

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Transcription:

J800 HOPE BUOYANCY COMPENSATOR OWNER S MANUAL EN1809 0 www.istsports.com 1 0120

I. INTRODUCTION I. INTRODUCTION CONTENTS II. GENERAL WARNING AND CAUTION Definition of WARNING, CAUTION and ATTENTION III. USING THE BCD Power inflator Attaching low pressure inflator hose Rapid exhaust valve Threading the tank band Attaching the BCD to the tank Donning the BCD Over pressure relief valves Cummerbund adjustment Care and storing IV. BUOYANCY DATA V. WARRANTY VI. PURCHASE & MAINTENANCE RECORD THANK YOU FOR CHOOSING IST J800 HOPE Buoyancy Compensating Device (BCD). Only the best materials specifically suited to diving conditions were used and your new BCD was designed, developed, and made according to the highest standard in diving equipment manufacturing so you can have many years of reliable service from it. Notice: Buoyancy compensation device is considered a Personal Protective Equipment (PPE). IST was submitted for testing and design validation, and was certified according to Art. 10 of Directive 89/686/EEC by: SGS United Kingdom Ltd. (Notified body No. 0120) 202B Worle Parkway, Weston-super-Mare, BS22 6WA United Kingdom The marking on this product represents compliance to the basic health and safety requirements of Annex II of Directive 89/686/EEC (European standard EN1809: 1997 (Category II PPE)). The number 0120 represents the certifying body SGS UK Ltd., which was entrusted to perform such task for the EC quality control system according to Art.11 A of Directive 89/686/EEC. The manufacturing process is carried out under strict supervision by: IST Sports Corp. Room A, 6 th Floor, No. 6, 345 Lane, Yangkuang Street, Taipei, Taiwan. Tel: +886 2 26272516 / Fax: +886 2 26599056 2 3

II. GENERAL WARNING AND CAUTION Please read and thoroughly understand this owner s manual and the label affixed to the BCD before using this product. If there is anything not clear, do not use this product and please contact your nearest authorised IST dealer with your queries. Do not use this BCD if you have not received proper dive training and certification from a recognised scuba training agency. This is not a life jacket. It does not guarantee the wearer to always be in a head-up floating position at the surface.. Do not use this BCD deeper than 50m (164ft) below surface. Repair, maintenance task and any disassembly must only be performed by an authorised IST dealer. Unauthorised service will render the warranty void and may cause this product to malfunction. Temperature range for using this BCD: Air -20 ~ 50 /-4 ~ 122 Water -2 ~ 40 / 28 ~ 104 Definition of WARNING, CAUTION and ATTENTION: Improper use or intentional misuse of this product may cause serious injury or death. WARNING Indicates a situation that, if not avoided, will result in serious injury or death Do not inhale gas from within this BCD Maximum recommended cylinder capacity (with max. 8 / 203mm diameter) is 15 litres. Do not use this BCD as a lift bag. It is not designed for this purpose and by doing so can result in uncontrollable ascent, which could lead to serious injury or even death. CAUTION ATTENTION Indicates a situation that, if not avoided, may result in serious injury or death. Indicates a situation that, if not avoided, may result in minor or moderate injury or damage to your scuba equipment. Prior to each dive, fully inflate the BCD and inspect for leakage, damage and proper operation. Before diving with this BCD in open water, it is highly recommended to familiarise yourself with it first in confined water. Ensure that you have clear access to the weight belt so it can be easily and quickly released without any obstruction when required in an emergency. 4 5

III. USING THE BCD Power inflator Depressing the oral inflator button while the BCD is empty may allow water to enter the bladder! The power inflator is located in the end of the corrugated inflator hose. Its working pressure is 7.6BAR (110psi) ~ 11BAR (160psi) while the ideal pressure is between 9.5BAR (138psi) ~ 10BAR (145psi). Inflator button: Use thumb to press the inflation button to inflate the BCD. Attaching low pressure inflator hose 1) Make sure there is an o-ring present in the male end of the low pressure BC hose. 2) Screw the hose into a low pressure port in your regulator s first stage. It is recommended to route the hose directly over the left shoulder. Deflation / oral inflation button: Use index finger to press the button to 1) deflate the BCD; 2) orally inflate the BCD through the mouthpiece. Using J800 s oral inflator while diving is a skill to be learned under the supervision of a certified scuba diving instructor. 6 Only attach the hose to a regulator s low pressure port. Attaching to the high pressure port can cause the hose to burst, which may result in serious injury or death. 7

3) Pull back the quick disconnect sleeve in the female end of the low pressure BC hose and connect it to the power inflator s quick disconnect nipple. Rapid exhaust valve It is located over the left shoulder (connected to the power inflator by the BCD s corrugated hose). It automatically releases air when the air pressure inside the bladder is 0.17kg/cm² (2.4psi) over the ambience. You can also conveniently vent gas in the BCD (by pulling downward while holding onto the power inflator) to reduce buoyancy while diving. 4) Open the tank valve SLOWLY. Check for any air leakage and proper power inflator function before using the BCD. Threading the tank band (1) (2) 8 9

(3) (4) Loop the tank locator strap over the tank valve. Adjust it to hang the BCD at a height which the right hand can reach back and turn the valve on / off but without the head hitting the valve when bending back. Tank locator strap (5) (6) Open the buckle and pull the free end of the band until tight. Half-close the buckle and thread the free end of the band through the end slot of the buckle. Close the buckle and secure the Velcro closure. Attaching the BCD to the tank Always check the tank band s threading before attaching it to a scuba cylinder. Wet the tank band first as the nylon webbing can stretches a little in this state. Make sure the metal ring is as close to the BCD as possible (as picture 6 above). This will provide the greatest range of adjustment. 10 Donning the BCD Loosen each shoulder strap to its maximum length by lifting up the bottom edge of the buckles. Open up the sternum strap waist strap 11

buckle and cummerbund. Ask a dive buddy to hold the BCD (with cylinder attached) steady so you can put the arms through. Shoulder strap buckle Sternum strap At this point your dive buddy can slowly let go the BCD and cylinder. Bend forward at the waist and tighten the shoulder straps and cummerbund further. Close and tighten the sternum and waist strap until snug but nor restricting movement and breathing. Sternum strap Waist strap Cummerbund Over pressure relief valves Adjust the shoulder straps (by pulling the webbing through the shoulder strap buckle while holding onto the D-rings) and fasten the cummerbund until snug. Located on the right shoulder and behind the right waist, they automatically release gas when pressure inside the bladder is 0.17kg/cm² (2.4psi) over the ambience. You can also pull either handle to adjust buoyancy as needed. 12 13

Cummerbund adjustment To adjust the cummerbund length, loosen the back plate end of the cummerbund and re-secure the Velcro as shown below. Please note the adjustment should have an overlap of at least 10cm (4 ) after the closing of the cummerbund. BCD care and storing - Do not put or drag the BCD across rough and / or sharp surfaces. - Do not place any sharp and / or heavy object on the BCD. - Do not expose the BCD to the sun while not actually diving. - After dive, rinse the BCD both inside and outside with fresh water. To rinse the inside, press the deflation button to let fresh water into the bladder through the power inflator mouthpiece. Shake the BCD so all corners can be rinsed then drain the water out completely in turn through the rapid exhaust valve and 2 over pressure valves. Repeat this process a few times. - Fully inflate the BCD and allow it to dry inside and out. Do not put your BCD away until it is completely dry! - Store the BCD slightly inflated in a cool, shaded place. - Have an authorised IST dealer to perform a thorough inspection of this BCD at least once a year. Do not hang the BCD on hook as ithe bladder can be easily damaged damage. This BCD is not weight-integrated. Do not use its pockets to store any weight. The inability to remove weight quickly is dangerous and can result in serious injury or death. Use a weight belt instead. 14 15

IV. BUOYANCY DATA Sizes Newton Pound force XXS 70N 15lbf XS 120N 2lbf S 140N 31lbf M 170N 38lbf L 220N 49lbf XL 270N 60lbf If a problem has developed with your BCD, please contact your nearest authorised IST dealer or IST distributor for return authorisation. Please properly package the BCD and send with your proof of purchase with postage prepaid. We reserve the right to service any non-authorised returns. V. WARRANTY Use of non-factory parts or any modification may (irreparably) damage this BCD, which can lead to a loss of buoyancy control or air holding capability while diving. This could result in injury or death, and will void your warranty. ONLY replace worn or damaged items with genuine, factory supplied or specified parts. Your BCD should be inspected by an authorized IST dealer at least once a year, and more often if you dive frequently. This is a required action to keep your warranty in effect The warranty of this floatation device is valid to the original owner only (with proof of purchase) AND it covers any defects in materials and / or workmanship for the period of 2 years from the date of purchase. Proper maintenance as prescribed in this manual is required. This warranty does not cover any wear and tear under normal usage. The following action will also invalidate the warranty: incorrect use of the BCD, the use of non-original parts, any commercial / rental usage, any modification, servicing task performed by an unqualified, non-ist authorised dealer. 16 17

VI. PURCHASE & MAINTENANCE RECORD Serial # Date of purchase (dd) / (mm) / (yy) Dealer s name & address Tasks performed: Service person: Date of service: Dealer: Tasks performed: Service person: Date of service: Dealer: Purchaser: Address: Tasks performed: Service person: Date of service: Dealer: (Dealer s stamp) Tasks performed: Service person: Date of service: Dealer: Tasks performed: Service person: Date of service: Dealer: 18 19

IST Sports Corp. Room A, 6 th Floor, No. 6, 345 Lane, Yangkuang Street, Neihu, Taipei, Taiwan. www.istsports.com 20 Ver. 09 / 99