OXYGEN CONSUMPTION AND TEMPERATURE IN THE AQUATIC ENVIRONMENT

Similar documents
OXYGEN CONSUMPTION AND TEMPERATURE IN THE AQUATIC ENVIRONMENT

Aerobic Respiration. Evaluation copy

Dissolved Oxygen in Water. Evaluation copy. Table 1. Temperature Range ( C) Trout Smallmouth bass Caddisfly larvae

Fish Respiration and Q 10

12mm Dissolved Oxygen Sensor Care and Use Instructions

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

PRODUCT SHEET. Order probe only as RXPROBE02

SS32L Dissolved O 2 Probe

DISSOLVED OXYGEN SENSOR BT34i

LAB 06 Organismal Respiration

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

LogIT Dissolved Oxygen Probe

Radnoti Liver Perfusion System

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Experiment 1 Introduction to Some Laboratory Measurements

Vapor Pressure of Liquids

SOLUBILITY OF A SOLID IN WATER

Vapor Pressure of Liquids

Gas Laws: Boyle s and Amonton s Laws Minneapolis Community and Technical College v.9.08

AP Biology 12 Cellular Respiration Lab

Pre-Lab 6: Gas Law ~ 70 ~

REASONS FOR NATURAL VARIATIONS IN DISSOLVED OXYGEN LEVELS

Biology Unit 2, Structure of Life, Lab Activity 2-3

Inquiry Investigation: Factors Affecting Photosynthesis

Experiment 18 Properties of Gases

Evaluation copy. Vapor Pressure of Liquids. computer OBJECTIVES MATERIALS

Generating Calibration Gas Standards

EXPERIMENT 1 TOOLS FOR LAB MEASUREMENT

C 6 H 12 O 6 + 6O 2 6H CO kilocalories of energy/mole of glucose

Physics 1021 Experiment 4. Buoyancy

PRECISION DISSOLVED OXYGEN MEASUREMENT SYSTEMS

Chemistry. TEKS 2D Organize, analyze, evaluate, make inferences, and predict trends from data.

Vapor Pressure of Liquids

D. De La Matter 2004 Swimming Pool Chemistry STUDENT ACTIVITIES:

Experiment C-6 Gas Solubility

SOLUBILITY OF A SOLID IN WATER

FISH 415 LIMNOLOGY UI Moscow

Technical Procedure for General Laboratory Equipment

Purpose: Hypothesis: Procedure:

Experiment #12. Gas Laws.

CHM111 Lab Gas Laws Grading Rubric

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Dissolved Oxygen/Temp Waterproof Tester

Gas Laws: Boyle s and Amonton s Laws MCTC Chemistry v.9.17

Experimental Procedure

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

Before you start sampling, be sure to read

UNIT 2 Chapter 3. Elodea and Photosynthesis. The Origins of Life. Learning Outcomes: Chapter 3 Lab/Activity #2. Introduction: Safety Issues:

What factors affect the rate of cellular respiration in multicellular organisms?

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Research Question How does the concentration of catalase affect the speed of the decomposition reaction of Hydrogen Peroxide into oxygen and water?

EXPERIMENT 1 BASIC LABORATORY TECHNIQUES AND TREATMENT OF DATA MEASUREMENTS

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

Oxygen Sensor with Electrode

Additional Reading General, Organic and Biological Chemistry, by Timberlake, chapter 8.

Application Note 183. Page 1 of Aero Camino, Goleta, CA Tel (805) Fax (805)

What does the % represent on the beakers?

To derive from experiment the relationships between Pressure (P), Volume (V), Temperature (T), and Water Solubility of gases.

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

BI-680 Online Dissolved Oxygen Controller Instruction Manual

EXPERIMENT 8 Ideal Gas Law: Molecular Weight of a Vapor

Dissolved Oxygen Probe (Order Code DO-BTA)

Vapor Pressure of Liquids

ASPHALT PLANT LEVEL 1

Contact Person(s) : Isabel M. Fisenne APPLICATION

BEFORE YOU OPEN ANY FILES:

Optical Dissolved Oxygen Meter

Reinforce design of experiments theory Make individual factorial designs and conduct analysis on responses

What is photosynthesis? Photosynthesis II: Dissolved O2

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

Deep Water Currents Lab

Water Quality Guidelines for Total Gas Pressure: First Update

A LAZAR LABORATORIES HANDBOOK DISSOLVED OXYGEN PRIMER

AP Biology Lab - Cell Respiration

APBiology Unit 2, Chapter 8

Title: Solubility of Gas A Daily Experience. Subject: Chemistry. Grade Level: 10 th 12 th

Boyle s Law: Pressure-Volume Relationship in Gases

TEMPERATURE S RELATIONSHIP TO GAS & VAPOR PRESSURE

Name Student Activity

TECHNICAL BULLETIN. TriControls. Control Materials for Liquid QC and Calibration Verification

1. Photosynthesis and Light. See real-time evidence that light causes photosynthesis to occur!

Dissolved Oxygen Probe (Order Code DO-BTA)

Determination of the Gas-Law Constant (R) using CO2

Conducting an XFe Assay in an Hypoxia Chamber at 3% O ²

Experiment 8 GAS LAWS

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Real World Metric System

AN OVERVIEW OF RESPIRATION AND AN INTRODUCTION TO DIFFUSION AND SOLUBILITY OF GASES 1

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

Experiment 12: MOLAR VOLUME OF AN IDEAL GAS

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq)

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Introduction to ChemSense

Aerobic reoxidation in marine sediments

LABORATORY INVESTIGATION

Exploring the Properties of Gases

User s Guide. Pressure Controller for liquid delivery systems

CORESTA RECOMMENDED METHOD N 6

Transcription:

OXYGEN CONSUMPTION AND TEMPERATURE IN THE AQUATIC ENVIRONMENT BACKGROUND READING Animal Physiology by Hill, Wyse & Anderson, 2004: pp. 130 139 & 198 201. Living material Freshwater fish, probably goldfish. ANIMALS & EQUIPMENT Equipment Macintosh computer; PowerLab virtual chart recorder; MacLab oygen meter and the Cameron O2 probe; BNC cables and other assorted cable connections; conditioned sea water; 100% N2 gas; compressed air; large test tubes; beakers; tubing; respiration chamber; vacuum grease. (Include a sketch of the equipment set up in your lab book that is of sufficient quality that you could use it to set up the same eperiment at a later date) STANDARD EXPERIMENTAL PROCEDURE This eperiment is based on closed system respirometry. Calibration of the Oygen Probes and Meters You will be recording the oygen content of water within the respiration chamber. To make your data meaningful, however, you must first calibrate the oygen probes and meters. This is very similar to calibrating a ph meter ecept that (a) the solutions used contain a known amount of O2 instead of H+/OH-, and (b) you will be injecting the calibration solutions into a small chamber in which the probe connects. 1. Preparing oygen calibration standards: We will do a 2-point calibration of each oygen probe. One probe will be at room temperature and the other will be at a higher or lower temperature. This is because you will be measuring oygen consumption of the fish at two different temperatures and it is important that the probe be calibrated with standards that are at the same temperature at which you are doing the eperiment. Thus, if you are measuring oygen consumption of a fish at 15 C, then you will want to use the probe that has been calibrated at 15 C. Calibration solutions: Air saturated water (~21% oygen) is generated by stirring a beaker of water using a stir bar and stir plate. This represents your high oygen standard. Your low oygen standard is a syringe containing water that with sodium sulfite added to it. This chemical effectively removes all the oygen from the water leaving your with a 0% oygen solution. Calculate the partial pressure of O2 (in units of mmhg) in each air-saturated standard: Probe 1 Probe 2 Temp: Barometric pressure: Partial pressure of oygen in air-saturated sample: 1

2. While recording the data with PowerLab, slowly inject about 2 ml of air-saturated water into the miniature oygen-measuring chamber at the appropriate temperature. Make sure there are no air bubbles in the system and wait until the reading stabilizes (about 1-2 min). Inject another 0.5 to 1 ml and confirm that the reading has stabilized. 3. Without stopping data collection, slowly inject 2 ml of sodium sulfite solution at the appropriate temperature into the miniature oygen-measuring chamber at the same temperature. Make sure there are no air bubbles in the system and wait until the reading stabilizes (about 1-2 min). Inject another 0.5 to 1 ml and confirm that the reading has stabilized. * Flush the miniature oygen-measuring chamber with about 15 mls of clean water. The probe can remain in this water while you continue with the calibration. 4. Use the UNITS CONVERSION function on the PowerLab chart recorder to convert from voltage to mmhg. 5. Check the accuracy of your calibration by repeating steps 2 and 3. If the readings are substantially different than your initial calibration (say, more than ~5 mmhg O2), repeat step 4 to adjust the conversion values. You may keep the system running while you prepare the animal for the eperiment. General Procedure Measuring Aquatic Oygen Consumption: Each respirometer consists of an animal chamber and a lid with a volume-compensating syringe barrel, sample etraction port, and overflow hole. 1. Fill a chamber with the appropriate test water (your professor will tell you what this is) and record the temperature of the water. Place the chamber in a water bath if the desired temperature is different from room temperature. 2. Remove 2 mls of this water and measure its oygen content by slowly injecting about 1.5 ml into the miniature oygen-measuring chamber at the appropriate temperature. Make sure there are no air bubbles in the system and wait until the reading stabilizes (about 1-2 min). Inject another ~0.5 ml and confirm that the reading has stabilized. This measurement will tell you how much oygen was in the water before the animal was introduced. 3. Gently place an animal in the chamber and turn the stir plate on such that the stir bar stirs really slowly (you want the water well mied, but you don t want the animal moving against a current). 4. Remove the syringe plunger and overflow cork from the lid and carefully slide the lid on, making sure there are no air bubbles trapped inside. Fill the syringe barrel with the appropriate water and introduce the plunger such that there are 10 mls of water in the volume-compensating syringe. Seal the chamber by plugging the overflow hole. You are now ready to begin measuring the oygen consumption of the animal. 5. After about 2 minutes, remove 2 mls of the water with a syringe and measure its oygen content by slowly injecting about 1.5 ml into the miniature oygen-measuring chamber at the appropriate temperature. Make sure there are no air bubbles in the 2

system and wait until the reading stabilizes (about 1-2 min). Inject another 0.5 ml and confirm that the reading has stabilized. IMPORTANT: This measurement will be your time = 1 sample so make sure you record the precise time that you etracted the sample from the animal chamber (not the time that you injected the sample into the miniature measuring chamber). You can use the comment function on PowerLab to help you record the precise time. 6. After about 5-7 minutes repeat step 5 with another 2 mls of water from the animal chamber. Continue to repeat for 20 30 minutes or until the po2 drops below ~70 mmhg O2. Again, always record the precise time at which you etracted each sample from the animal chamber. ** Throughout this entire procedure, you should be carefully recording the behavior of the animal. 7. Repeat steps 1-6 with another animal at the same temperature. 8. Repeat steps 1-6 with the same two animals but at a different water temperature such that you end up with a sample size of two for both temperatures. 9. When you are done measuring the oygen consumption of a fish at 2 different temperatures, carefully remove the animal from the chamber and weigh it, in water, to the nearest 0.1 g on the top loading balance. Subtract the weight of the container + water. ADDITIONAL IMPORTANT POINTS How do you know that you are measuring the oygen consumption of the fish and not some goo clinging to the side of the chamber? What is the control for etraneous O2 consumption? Run at least one control for each probe after testing the animals. You may want to cover the respirometer to minimize light. Why might this help the eperiment? If you choose to do this, don't forget to note this in your lab notebook. Take chamber temps before and after each run and average. Use average temp for calculations. Weighing stresses the animals. Therefore, weigh each individual only after you have taken the VO2 measurements. 3

Calculations You should have 3 5 data points (time, mmhgo2) per animal per condition. Graphing these points will show you how much oygen the animal used per time: E. po2 (mmhg O2) Time (min) In published papers, oygen consumption data is commonly represented in units of ml O2/individual*h or ml O2/g*h. Thus, you need to convert po2 into ml O2. This can be a bit tricky since the amount of gas dissolved in a fluid is dependent upon more than just partial pressure. To convert po2 into ml O2, you need to know the following temperature salinity volume of the fluid in the respirometer. You have measured the water temperature, and the salinity of sea water is roughly 32 ppt. Using these two factors, look up the solubility coefficient of O2 in your fluid sample from the table provided in lab. When estimating the volume of the respiration chamber, remember to take into account the volume of the animal. Now you can use Henry's law to calculate the O2 consumption of the fish in ml O2/g*h: Oygen Consumption = α * ( po2/h)* VH2O * (1/g) Where: α = solubility coefficient in units of ml O2/L liquid; po2 = the change in partial pressure of O2; h = time; VH2O = volume of water in respirometer; g = weight of fish in grams. Be careful with units. PRE-LAB (Due at the start of the lab) 1. Why can oygen consumption be used as a measure of metabolic rate? 2. When a physiologist equates oygen consumption with metabolic rate, what one big assumption is the physiologist making? Is this a valid assumption for the eperiment you are doing today? 3. What are three factors other than temperature that can influence an animal s metabolic rate? In today s eperiment, how will you account for each factor listed when you analyze the data? 4. When comparing your results to literature values, you discover that the oygen consumption that you measured was, on average, twice as high as that reported in the 4

literature for the same animal. What are three biologically-based plausible reasons for this difference? POST-LAB (Due net week in lab) 1. Generate one graph that summarizes the main result of your study on how temperature influences fish oygen consumption. The graph must be computer generated and made as "pretty" as possible (i.e., don't just slap something together in StatView and print it out). Don't forget to label the aes and include units. 2. Construct a complete figure legend to accompany the figure. Keep in mind the criteria outlined in the Paper Dissection lab and your writing handbook. 3. Calculate a Q 10 value for oygen consumption for each animal used in your study. RESEARCH PAPER **NOTE: If you are going to write this paper up for credit, you need to incorporate data from additional lab groups. This will give you a larger sample size and make your analysis much more meaningful and fun. You have just performed a classic eperimental study in animal physiology ==> you've taken one species and subjected it to different environmental conditions and monitored its response. As with previous studies, one of the best ways to begin writing this study up into a paper is to determine what your results are saying and how to present them. Some questions to consider when thinking about how to present your results: What type of metabolic rate have you measured (e.g., standard, resting, basal, routine, etc.)? Is it important to show raw data? Why or why not? What is the best way to show the trends that I want to emphasize? How should I deal with any outliers in my data set? You should have enough data points to analyze your data statistically. What aspects of your data would it be logical to compare? What test(s) will you use? How will you present the statistical results? One of the keys to writing this study up into a paper will also be determining what you want this study to be about. In other words, how are you going to pitch your study to readers. For eample, is this paper going to be about: General response of animals to changes in temperature (goldfish are simply a model system)? Specific responses of this species because they are of physiological importance (i.e., El Nino and global warming; in this case, you're really concerned with this particular animal). How metabolic rate changes with temperature (again, you are just using goldfish as a model system)? Discussions should definitely include a comparison with some previous studies. Another element you could bring into the discussion concerns the eperimental design. What do 5

you think your results would look like if the animals were acclimated to or raised in the different temperatures rather than acutely eposed? OXYGEN SOLUBILITIES in ml O2/(L*mmHg) Temperature ( C) Freshwater Sea water (appro. 30ppt) 5 0.0565 0.0464 10 0.0499 0.0413 15 0.0445 0.0371 20 0.0400 0.0336 25 0.0363 0.0306 30 0.0331 0.0279 35 0.0303 0.0256 6