G-EOL. Discover the simplicity of gait therapy intended for daily use

Similar documents
G- EOSYSTEM training more, more effectively. visit rehatechnology.com

WalkOn product range. Dynamic Ankle-Foot Orthoses. Information for specialist dealers

Rifton Pacer Gait Trainers A Sample Letter of Medical Necessity: School-based Therapy with Adolescents

ErgoTrainer. body-weight-supported rehabilitation. Training with significant

C-Brace Orthotronic Mobility System

Normal and Abnormal Gait

Running injuries - what are the most important factors

Mechanical Knee Prescription Guide

ASSESMENT Introduction REPORTS Running Reports Walking Reports Written Report

EasyStand Evolv. Evolv Basic Specifications. The Natural Way to Stand

Biomechanics and Models of Locomotion

SCHEINWORKS Measuring and Analysis Systems by

Spinal Cord Injury (SCI) and Gait Training

Self-fulfilling prophecy? Current affairs. Reality check 11/29/2011

REAL. Simple, Intuitive, Powerful Real.

Rifton Pacer Gait Trainer

Microprocessor Technology in Ankle Prosthetics

BIODEX. New Jersey clinic enhances patient rehab using music-assisted gait training CASESTUDY. Body In Balance Physical Therapy and Fitness Center

The three steps for biomechanical assessment are the following: > Periodically verify the results and the efficacy of treatment

Center of Mass Acceleration as a Surrogate for Force Production After Spinal Cord Injury Effects of Inclined Treadmill Walking

Rifton Pacer Gait Trainers A Sample Letter of Medical Necessity: Homecare Setting for Adults

Gait Analyser. Description of Walking Performance

Transformation of nonfunctional spinal circuits into functional states after the loss of brain input

Spasticity in gait. Wessex ACPIN Spasticity Presentation Alison Clarke

A mechanized gait trainer for restoration of gait

Adaptive Locomotor Training on an End-Effector Gait Robot Evaluation of the ground reaction forces in different training conditions

INTRODUCTION TO GAIT ANALYSIS DATA

The Starting Point. Prosthetic Alignment in the Transtibial Amputee. Outline. COM Motion in the Coronal Plane

empower Reclaim your power. Information for technicians empower Ottobock 1

video Outline Pre-requisites of Typical Gait Case Studies Case 1 L5 Myelomeningocele Case 1 L5 Myelomeningocele

EN-MOTION TREADMILL. EN-Motion: the ultimate PHYSIO treadmill

WORKBOOK/MUSTANG. Featuring: The R82 Next Step Development Plan. mustang. R82 Education

1B1 Meridium. Reclaim your way. Information for practitioners. Meridium Ottobock 1

Posture influences ground reaction force: implications for crouch gait

Clinical view on ambulation in patients with Spinal Cord Injury

PRO-FLEX. Less load, more dynamics

Meeting the Challenges of Diverse Seniors Many with Dementia, Stroke, Parkinson s disease BIODEX

The History. Larry A. Suecof, DPM, FACFAS, CWS Orthomerica Products, Inc. All Rights Reserved. SL00189 Rev. E

Unity Sleeveless Elevated Vacuum System

Alignment & Stance in High Performance Skiing

The overarching aim of the work presented in this thesis was to assess and

NeuroOrthopaedics lower extremity

CHAPTER IV FINITE ELEMENT ANALYSIS OF THE KNEE JOINT WITHOUT A MEDICAL IMPLANT

The Rifton TRAM. long-term care but home and into the community. In-home healthcare solution RIFTON TRAM

REPORT DOCUMENTATION PAGE

Empower. Reclaim your power. Information for technicians. Empower Ottobock 1

Body Stabilization of PDW toward Humanoid Walking

Mobility Lab provides sensitive, valid and reliable outcome measures.

The importance of physical activity throughout an individual's life is indisputable. As healthcare

Walking Aids. 258 Introduction to LiteGait. 259 LiteGait - Gait Training Devices. 262 LiteGait - Accessories. 264 Walkers for adults

Motion Control of a Bipedal Walking Robot

video Purpose Pathological Gait Objectives: Primary, Secondary and Compensatory Gait Deviations in CP AACPDM IC #3 1

Aeris Performance 2. Product Manual

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

ROBOTIC EXOSKELETONS. BME 281 Brandon Williams

FROM CHINESPORT S GENERAL CATALOGUE 2015 EDITION

C-Brace Reimbursement Guide

empower Reclaim your power. Information for users

Intelligent Ventilation. Hamilton Medical. Intelligent Ventilation since 1983

Dynamic Pacer (K640 standard upper and utility base)

The technique of reciprocal walking using the hip guidance orthosis (hgo) with crutches

ParaGolfer. Get up and play. Information for end users

SPECIFIC METHODS OF HIP IMPLANT NON-INVASIVE ASSESSMENT

TITLE subtitle. Session Examples BASIC STAGE

PURPOSE. METHODS Design

Gait Analysis at Your Fingertips:

Ambulatory monitoring of gait quality with wearable inertial sensors

Lumbar Decompression Surgery: Correction of foot drop

The Promise of Achieving Higher Standards in Children s Health. The Gait and Motion Analysis Laboratory Referral Guide

WALKING AIDS AND GAIT TRAINING

Neurorehabil Neural Repair Oct 23. [Epub ahead of print]

3 people 3 unique lifestyles 3 advanced foot solutions

Element DS. Product Manual

Stride October 20, 2017

Serve the only stroke in which the player has full control over its outcome. Bahamonde (2000) The higher the velocity, the smaller the margin of

Ecole doctorale SMAER Sciences Mécaniques, Acoustique, Electronique, Robotique

Adaptation to Knee Flexion Torque Assistance in Double Support Phase

K2 Foot. Product Manual

Assessments SIMPLY GAIT. Posture and Gait. Observing Posture and Gait. Postural Assessment. Postural Assessment 6/28/2016

Analysis of ankle kinetics and energy consumption with an advanced microprocessor controlled ankle foot prosthesis.

C-Brace Reimbursement Guide

Plié 3 Microprocessor Knee

NEUROLOGICAL INSIGHTS FOR TEACHING GOLF TO TODAY S FITNESS CHALLENGED

premise that interdependent body systems (e.g. musculoskeletal, motor, sensory, and cognitive

Gait pattern and spinal movement in walking - A therapeutic approach in juvenile scoliosis

MOTION FOOT MX. Manual

MOVEMENT IN A STATIONARY WORLD

Development of a Gait Rehabilitation System Using a Locomotion Interface Hiroaki Yano*, Kaori Kasai*, Hideyuki Saitou*, Hiroo Iwata*

EXPERIMENTAL STUDY OF EXOSKELETON FOR ANKLE AND KNEE JOINT

or

Stability Trainer. New! Balance Products. Rocker and Wobble Boards. New!

Dynamix Ankle Foot Orthoses Range

Aeris Activity. Product Manual

Kintrol Instructions for Use Product Number: VS4

Safety/Injury. Short-Term. Long-Term. Balance/Imbalance Acute Injury Falls

LOCOMOTION CONTROL CYCLES ADAPTED FOR DISABILITIES IN HEXAPOD ROBOTS

EasyStand Evolv. Evolv Specifications. The Natural Way to Stand

Normal Gait and Dynamic Function purpose of the foot in ambulation. Normal Gait and Dynamic Function purpose of the foot in ambulation

Meridium. Reclaim your way. Information for clinicians

Identify and explain how specific kinematic and kinetic elements relate to the absolute speed technical model

Transcription:

G-EOL Discover the simplicity of gait therapy intended for daily use

Reha Technology a passion for robotic-assisted gait therapy For over 10 years, Reha Technology has been successfully developing innovative, robotic gait therapy systems in the field of neurological rehabilitation. The G-EO range of systems, which is based on the end-effector principle, simplifies the work of therapists, reduces the load on the body, and supports a broad and diverse spectrum of patients with limited movement and capability. Reha Technology products provide for an individual course of therapy with intelligent robotic technology and allow for the intensity of the therapy to be adapted according to the patient. One in 7 after stroke Who wants to relearn walking, has to walk. Prof. Dr. Stefan Hesse (1960-2016) Former Head of the Neurology Department at the Rehabilitation Clinic, Medical Park, Berlin Founding member of Reha Technology AG Study: Mehrholz, J. et al «Electromechanical-assisted training for walking after stroke.» Cochrane Database Syst Rev. 2013 Jul 25;7 The Cochrane Library 2013, Issue 7 (2) Robotic-assisted gait therapy is an effective method in the rehabilitation of neurological and orthopedic patients. Technology has evolved significantly over the last few years in collaboration with leading clinics and universities. Today, robotic-assisted therapy is indispensible in neurological rehabilitation. Countless studies have verified the clinical evidence of the effectiveness of end-effector-based gait therapy in comparison with conventional therapy. The use of gait trainers in clinics and practices has significantly increased the economy and efficiency of gait rehabilitation, eased the physical workload of therapists and helped patients to begin walking independently in a more effective and targeted way. The Reha Technology G-EOL gait trainer enables a wide variety of neurological pathologies to be treated very early on in a performance-related manner. G-EOL - reduce to the max Individual and Automated Gait settings such as step length, step height and ankle alignment without interrupting the ongoing therapy session. Motorized and automatic weight support for up to 200 kg (440 lb) - dynamic and static. Hip control mechanically active, with back pad.

3D positioning of the body axes anterior electrically up/down posterior electrically right/left The positioning of the footplates at the same level as the patient s feet allows optimal access. End-effector principle short patient setup time The G-EOL gait trainer with its end-effector principle represents a significant reduction in workload for therapists. Guidance of the affected limb requires only distal securing in this case, the feet. There are no complicated setup and adjustment steps with the average setup time for a patient being around five minutes. In device-based gait rehabilitation, this represents an essential factor in an efficient course of therapy. The patient can begin his/her therapy quickly, avoiding lengthy setup procedures. The therapist s physical workload is reduced, leaving more time for effective therapy and allowing more patients to be treated in a day. Natural gait pattern - continuously adjusted during therapy G-EOL supports patients by providing a simulation of physiological gait pattern and muscle activation. Various gait settings can be changed without interrupting the therapy and allow the gait pattern to be customized in accordance with the clinical image of the patient. Gait parameter Step height 0 in Step length Step length Ankle angle correction 22 in 0º 3.3 in Dorsal flexion - 10º + 10º Step height 7.8 in 0 º 0 Steps/min Plantar flexion - 10º + 10º Cadence 70 steps/min 1.43 mph at max. step length

Modularity expanding the range of applications The modular nature of Reha Technology s G-EOL gait trainer supports therapists and the therapy process as a whole by customizing the therapy goals and expanding the patient population. The range of applications is broad and diverse: Stroke Parkinson's disease Multiple sclerosis Spinal cord injuries Traumatic brain injury Cerebral Palsy Orthopedic and trauma cases Step width settings, in 4 levels of 0.3 inches per footplate Mechanical knee brace for improved knee stability The knee brace provides for stable guidance of the knee and ankle joints. For patients with severely limited to no knee control (FAC 0 to 1), the mechanical knee brace is the perfect aid for targeted gait therapy. The knee brace guides the patient in a physiologically correct gait pattern. The therapist can thus focus on other important therapy-related priorities, such as their patient s hip and torso control. 5 Functional electrical stimulation for additional neuromuscular activity Functional electrical stimulation (FES) can be perfectly combined and synchronized with robotic-assisted gait therapy. It targets affected muscle groups and supports their activation at the appropriate time in the gait cycle. The patient benefits from a better therapeutic experience. 4 3 2 1 3 1 4 5 2

Evaluating the therapy high intensity, short times & reproducible Neurological rehabilitation must be customized and tailored to individual patients with the correct intensity. To ensure a long-lasting, successful course of therapy, it is important to perform movements with a high level of repetition, for a specific task, and in a physiologically correct way. Reha Technology s G-EOL performs a key function precisely for this targeted, early and intensive therapy. The robotic-assisted gait trainer simplifies and enhances both the course of therapy for therapists, as well as the therapy process as a whole. The patient, the therapist, and the field of therapy as a whole all enjoy huge benefits. The physical workload of therapists is minimized through the use of robotic-assisted gait therapy. The therapist can focus on the patient and the therapy in a more precise and targeted way. This improvement to the therapy leaves more time for monitoring and informing the patient, which in turn leads to an important positive increase in both the intrinsic and extrinsic motivation of patients and therapists. 67% 27% Efficiency comparison of robotic-assisted therapy versus conventional therapy Study: Hesse, S. et al «Robot-Assisted Practice of Gait and Stair Climbing in Non-Ambulatory Stroke Patients.» JRRD Volume 49, Number 4, 2012, p. 613 622. Conventional therapy up to 100 steps Treadmill up to 400 steps (with/without BWS) 30Min. G-EOL up to 1400 steps Hip and body position - the basis for good gait quality Therapy comparison with regard to number of steps Study: Moseley, et al. 2005; Hesse, et al. 2012 Controlling the body position is another important factor for successful, long-lasting neurological gait rehabilitation. The G-EOL gait trainer has a mechanical torso and hip control which operates on three planes - frontal, transverse and sagittal. The therapist can thus control the patient s body position, and also the natural knee and hip extension. The movement of the hips and torso can also be adjusted optimally to the patient at any time without interrupting the therapy via the graphical user interface. Motorized weight support plus/minus 0-2 in; dynamic/static Progression through the precise representation of the weight support Customized hip and torso guidance, right/left +/- 6 in; dynamic/static Continuous, static setting of the body position, anterior/posterior

Technical details/specification 310 cm (10 ft 2 in) 260 cm (8 ft 6 in) 204 cm 6 ft 8 in Specifications Weight Power supply Max. speed Max. cadence Max. step length 800 kg (1760 lb) 230V 2.3 km/h (1.43 mph) 70 steps/min. 55 cm (22 in) Step height 8.5-20 cm (3.3-7.8 in) Ankle angle correction -10 / +10 Torso guidance (right/left) +/- 15 cm (6 in) Weight support up to 200 kg (440 lb) Patient height (min./max.) 90-200 cm (2.9-6.5 ft) Headquarters Reha Technology AG Solothurnerstrasse 259 4600 Olten, Schweiz www.rehatechnology.com sales@rehatechnology.com US branch Reha Technology USA, Inc. 5209 Militia Hill Road, Suite 102 Plymouth Meeting, PA 19462, USA www.rehatechnology.com sales@rehatechnology.com G-EOL/PB_1810_EN