Rad-57 Pulse CO-Oximeter

Similar documents
Oxygen Saturation Monitors & Pulse Oximetry

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

Emergency Transport and Ventilation

Hospital and Transport for Controlled Breathing

Oxylog VE300 Emergency & Transport Ventilation

IEC C LASSIFICATIONS:

VT650. Gas Flow Analyzer. Technical data. Key benefits and features:

Oxylog 3000 plus Emergency & Transport Ventilation

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

Introducing Astral. Greater freedom. Confident care. Designed efficiency

WARNING: EXPLOSION HAZARD

Solutions for transcutaneous monitoring

.$2;,)*3/6$ USER MANUAL

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Airox Supportair Ventilator

CARESCAPE V100. Vital signs monitor Connecting intelligence and care. Features

Warning: Keep away from small children; -30 C +70 C User Guide GO2 % SpO2

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Gebrauchsanweisung Mode d' emploi Instrucciones para el uso Istruzioni per l'uso Инструкции по зксплуатации. ri-fox N

Instructions to User

Fingertip Pulse Oximeter

SenTec OxiVenT Illuminate Ventilation and Oxygenation PCO2 PO2. Digital Transcutaneous Blood Gas Monitoring

Hallowell EMC Anesthesia WorkStation Operating Manual

Instruction for Use. Mobile Pulse Oximeter. (File No.: IFU-MPO) Version: 01. Zhejiang Medzone Medical Equipment Co.,Ltd

Operation and Maintenance of the EPV200 Portable Ventilator

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

HAMILTON-C1. Technical specifications

Supporting your patients every breath

Portable Oxygen Concentrator. Give your patients more freedom with mobile oxygen on demand


MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

DATA SHEET. VENTILATION SERVO-s

Oxylog 2000 plus Emergency & Transport Ventilation

Blood Parameter Monitoring System 550

TABLE OF CONTENTS 1 Overview Appearance Name and Model Intended Use Feature List Important Acroynms...

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

HAMILTON-C1 neo. Technical specifications

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

Optical Dissolved Oxygen Meter

D-MAS HyperSat DanMedical hyperbaric remote patient monitoring system

Optical Dissolved Oxygen Meter

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

HAMILTON-T1 HAMILTON-T1. Intelligent transport ventilation

Code Blue III Simulators. ALS and Emergency Care Simulators

A9600 Anesthesia Workstation. Your healthcare, we care.

Dräger Oxylog 3000 plus Emergency & Transport Ventilation

The anaesthesia workstation focused on you

Technical specifications for SW version 2.0.x. Mode form Mode name Mode Adult/Ped Neonatal

SenTec Digital Monitoring System Illuminate Ventilation and Oxygenation in Neonatology PCO2 PO2

How Ventilators Work. Chapter 3

Organis TestChest. Flight Simulator for Intensive Care Clinicians

Solutions. Digital pressure management solutions. Copyright 2013 GaleMed Corporation

Milestones of Aeonmed Ventilators

INTRODUCING CARDIOSAVE Hybrid MORE THAN A PUMP. A REVOLUTION. SPECIFICATIONS

Hand-held pressure calibrator with integrated pump Model CPH6600

PULSOX -2 INSTRUCTION MANUAL

Multi-Gas Analyzer. Multi-Gas Analyzer bcgroupintl.com. Features - MGA MGA-3050 Multi-Gas Analyzer

Instructions to User

Technical Data and Specifications

SLE5000 Infant Ventilator with HFO

INTENSIVE CARE VENTILATORS

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Oxygen Saturation Monitor PULSOX -2. Instruction Manual

Using the Lifebox oximeter in the neonatal unit. Tutorial 1 the basics

fabian HFO Our 4-in-1 device

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Minimum size for maximum performance

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

COPYRIGHT Ramsey Medical, Inc.

SLE5000 Neonatal Ventilator with High Frequency Oscillation

HAMILTON-T1. Technical specifications HAMILTON-T1

The anaesthesia workstation focused on you

fabian HFO: Modular, Powerful, Versatile.

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

Portable Oxygen Concentrator. Introduction

First Class. Monitoring. solutions for. Range of monitors CO 2 O 2 SpO 2 ECG NIBP. More Choices to meet your needs

Monitoring & Critical Care. Midmark Animal Health Products

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Pneumatic high-pressure controller Model CPC7000

CATALOG NO. FIG DESCRIPTION NIB A Replacement Hose for Critikon-type devices-models 8100, 8100T, 9300XL, & 1846SX. 12

RESPIRATORY MONITORING AND OXIMETRY

Instructions to User

HAMILTON-G5. The modular high-end ventilation solution

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

NEONATAL/INFANT VENTILATOR

Finger Pulse Oximeter. User Manual. Innovo Medical Stafford Centre Drive Suite B Stafford, TX

Additel 761 Automated Pressure Calibrators

Sensor. Directions For Use


Mass Flowmeters. Mass Flowmeters for Gases

Astral in AirView: Improving patient care through connectivity. ResMed.com

D Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

The centerpiece of a comprehensive anaesthesia workstation

V8800 Ventilator System. Your healthcare, we care.

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

Precision pressure sensor Basic version Model CPT6020

Transcription:

Pulse co-oximeter Rad-57 Pulse CO-Oximeter Helps detect methemoglobinemia and carbon monoxide poisioning on-site in seconds

PeRFoRMance Specifications measurement range Oxygen Saturation (SpO2)........................................ 0% - 100% Methemoglobin (SpMet)........................................ 0% - 99.9% Carboxyhemoglobin (SpCO)....................................... 0% - 99% Total Hemoglobin (SpHb)........................................0-25 g/dl Oxygen Content (SpOC)........................................... 0% - 99% Perfusion Index (PI)............................................ 0.02% - 20% Pleth Variability Index (PVI)......................................... 0-100 Arterial Oxygen Saturation Accuracy 1 Saturation*................................................... 60% to 80% No Motion Adults, Infants, Pediatrics............................................ ±3% Saturation....................................................70% to 100% No Motion Adults, Infants, Pediatrics............................................ ±2% Neonate............................................................ ±3% Motion Adults, Infants, Pediatrics, Neonates.................................. ±3% Low Perfusion Adults, Infants, Pediatrics, Neonates.................................. ±2% CaRBoxyhemoglobin Saturation accuracy (%Spco) 1 SpCO....................................................... 1% - 40% ±3% Methemoglobin Saturation accuracy (%SpMet) 1 SpMet........................................................1% - 15% ±1% TOTAL HEMogloBin ACCURacy (SpHb g/dl)** 1 Adults/Infants/Pediatrics................................ 8-17 g/dl ±1 g/dl pulse rate accuracy 1 Pulse Rate................................................... 25-240 bpm No Motion Adults, Infants, Pediatrics, Neonate............................... ±3 bpm Motion Adults, Infants, Pediatrics, Neonate................................ ±5 bpm Low Perfusion Adults, Infants, Pediatrics, Neonate................................±3 bpm batteries Type..........................................................4 AA Alkaline Capacity.................................................... up to 10 hours environmental Operating Temperature.......................... 0 F to 129 F (-18 C to 54 C) Storage Temperature....................... -40 F to 158 F (-40 C to +70 C) Operating Humidity..............................5% to 95%, non-condensing Operating Altitude........................500 mbar to 1060 mbar pressure, -1,000 ft to 18,000 ft (-304m to 5,486m) Effective battery life will be reduced when operating the instrument below 5 degrees Fahrenheit due to alkaline battery technology. dimensions Handheld.......................... 6.2 x 3.0 x 1.4 (15.8 cm x 7.6 cm x 3.6 cm) weight Handheld.....................................................13 oz (.37 kg) trending Provides 72 hours of trending at 2 second resolution of SpO2, SpCO, SpMet, Pulse Rate, Perfusion Index, and PVI. Output to PC running Masimo TrendCom Utility. SpO2 modes Averaging mode............................... 2, 4, 8, 10, 12, 14 or 16 seconds Sensitivity.......................................... APOD, Normal and Max FastSat...........................................................On / Off alarms Audible and visual alarms for high and low saturation and pulse rate (SpO2 1% to 99%, SpCO 1% - 98%, SpMet 1% to 99.5%, PI 0.03% - 19%, PVI 1% - 99%, and pulse rate 30-235 bpm) display/indicators Data Display....................................... %SpO2, %SpCO, %SpMet, SIQ bar, PI bar, Pulse Rate, Perfusion Index, Patient Volume Index, low Signal I.Q., alarm status, alarm silenced status, and battery status. Type.................................................................. LED 2011 Masimo Corporation. All rights reserved. resolution Oxygen Saturation (%SpO2)..............................................1% Pulse Rate (bpm).................................................... 1 bpm Carboxyhemoglobin Saturation (%SpCO) Numeric Display.........................................................1% Methemoglobin Saturation (%SpMet) Numeric Display.......................................................0.1% compliance EMC Compliance.......................................EN60601-1-2, Class B Equipment Classification........................................IEC 60601-1 Degree of Protection................................... Type BF-Applied part * When used with rainbow sensors ** Requires rainbow SpHb sensor 1 SpO2, SpCO, and SpMet accuracy has been validated on healthy adult male and female volunteers with light to dark skin pigmentations in the range of 60% - 100% SpO2, O% - 40% SpCO, and 0% - 15% SpMet against a laboratory CO-Oximeter. SpHb accuracy has been validated on healthy adult male and female volunteers and on surgical patients with light to dark skin pigmentations in the range of 8 g/dl to 17 g/dl SpHb against a laboratory CO-Oximeter. The SpCO, SpMet and SpHb have not been validated with motion or low perfusion. Pulse Rate accuracy has been validated in the range of 25-240 bpm in bench top testing against a Biotek Index2 simulator. Respiration rate accuracy has been validated for the range of 4 to 70 breaths per minute in bench top testing. Clinical validation for up to 30 breaths per minute was also performed with the Masimo Acoustic Respiration sensor and instrument. The variation in accuracy specifications equals plus or minus 1 standard deviation which encompasses 68% of the population. Contact Masimo for testing specifications. AcceSSories Sensors PN 2201 Adult rainbow DCI-dc3 Light Shields Carry Case Quick reference GUIDE PN 2696 Adult rainbow DCI P/N 2357 PN 2405 1 Foot rainbow Patient Cable PN 2207 (Black) PN 2815, pack of 10 PN 2208 (Red) PN 33650 Protective boots available in multiple colors Masimo U.S. Tel: 1 877 4 Masimo info-america@masimo.com Masimo International Tel: +41 32 720 1111 info-international@masimo.com 6245-7031A-0811

Emergency Mainstream Capnometer EMMA Mainstream Capnometer Immediate capnometry at your fingertips Actual Size > Small, portable capnometer, EMMA requires virtually no warm-up time, with full accuracy in 15 seconds to measure end-tidal carbon dioxide (EtCO2) and respiration rate > Compact, lightweight design fits in the palm of your hand for unmatched mobility and convenience > Used for short-term EtCO2 monitoring for adult, pediatric, and infant patients > Flexible use at multiple points of care, including pre-hospital, emergency medicine, operating room, intensive care unit, and long-term acute care > Helps clinicians assess the effectiveness of CPR and guide ventilation, allowing them to make adjustments in the course of treatment, breath by breath > Rugged, water-resistant design for reliable operation in challenging environments > Easy to maintain no routine calibration required

FEAtURES > Simple, easy-to-use interface for quick setup and one-touch programming > Audible and visual alarm system for No Breath Detected, No Adapter, Check Adapter, and adjustable high and low EtCO2 alarm > Long battery life up to 12 hours of normal use with two standard AAA lithium batteries Alarm Limits Alarm limits and visual alarm status indicator, silence active alarms for two minutes Bar Graph Highly visible bar graph provides continuous feedback on end-tidal carbon dioxide concentration, breathing activity, or alarm status End-tidal Carbon Dioxide Quantitative EtCO2 is updated every breath Respiration Rate RR is displayed after two breaths and updated every breath 2013 Masimo Corporation. All rights reserved. Power Button Airway Adapter Warm-up time to full accuracy in 15 seconds Comes in adult/ pediatric and infant sizes PERFORMAnCE Ranges CO2...0-99 mmhg 0-9.9 kpa RR...3-150 bpm accuracy (standard conditions) CO2...0-40 mmhg +2 mmhg; 41-99 mmhg 6% of reading 0-5.3 kpa +0.3 kpa; 5.4-9.9 kpa 6% of reading RR...+1 bpm BattERiES Type...2 (two) AAA Cell Alkaline or Lithium Battery life... 8 hours (Alkaline) 12 hours (Lithium) environmental Operating temperature... -5 to 50 C (23 to 122º F) Operating atmospheric pressure...70 to 120 kpa Operating humidity...10-95%, non-condensing Storage temperature... -30 to 70 C (-22 to 158º F) Storage atmospheric pressure...50 to 120 kpa physical characteristics Dimensions...2.1 x 1.5 x 1.5 (5.2 x 3.9 x 3.9 cm) Weight... 2.1 oz (with Alkaline batteries) AdAPtER information Dead space adult/pediatric...6 ml Dead space infant...1 ml Kit ACCESSORies > EMMA Kit* EMMA (mmhg) PN 9632 EMMA (kpa) PN 9633 > EMMA Airway Adapter Adult/Pediatric Box of 25 PN 17448 > EMMA Airway Adapter Infant Box of 10 PN 17449 * In order for the EMMA Kit to provide readings, either of the listed airway adapters is required. Kit includes EMMA, pouch, and lanyard. Caution: Federal law restricts this device to sale by or on the order of a physician. Masimo Sweden AB Svärdvägen 15, 182 33 Danderyd, Sweden Masimo U.S. Tel: 1 877 4 Masimo info-america@masimo.com Masimo International Tel: +41 32 720 1111 info-international@masimo.com 7094-7582D-1213