TP Validating a dynamic grid model with tracer gas injection and analysis

Similar documents
Drilling Efficiency Utilizing Coriolis Flow Technology

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow

Traveling Waves vs. Standing Waves

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

CFD Modeling of Thermal Manikin Heat Loss in a Comfort Evaluation Benchmark Test

Finding leaks in Main Cryogenic Heat Exchangers without shutdown

Flow metering in gases Introduction to COMBIMASS family

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

A SEMI-PRESSURE-DRIVEN APPROACH TO RELIABILITY ASSESSMENT OF WATER DISTRIBUTION NETWORKS

The Next Generation for Level Control. By Ryan Spooner, Singer Valve

Low gas volume & flow measurements made easier Gas Endeavour

VALVE CRITICALITY MODELING

FIRE PROTECTION. In fact, hydraulic modeling allows for infinite what if scenarios including:

RESIDENTIAL WATER DISTRIBUTION

Fisher DVI Desuperheater Venturi Inline

Pipeline Flooding, Dewatering and Venting Dr Aidan O'Donoghue, Pipeline Research Limited, Glasgow, Scotland

Experimental determination of deflagration explosion characteristics of methane air mixture and their verification by advanced numerical simulation

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System

BLOCKAGE LOCATION THE PULSE METHOD

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility

Modelling of the Separated Geothermal Water Flow between Te Mihi flash plants

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

Application Note AN-107

INTEGRITY, SAFETY AND EFFICIENCY IN LNG TRANSFER IMPACT OF EMERGENCY SHUTDOWN AND RELEASE OPERATIONS

DP Ice Model Test of Arctic Drillship

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Physical Analysis Model Report

OIL AND GAS INDUSTRY

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

SAFETY PHILOSOPHY FOR SERVICE LINES AND GAS INSTALLATION

WAVE IMPACTS DUE TO STEEP FRONTED WAVES

Characteristics of Decompression Tank Internally Pressurized With Water Using OpenFOAM Syamsuri 1, a

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

DEVELOPMENT AND TESTING OF AIR EXCHANGE RATE METHODS TO IMPROVE COST EFFECTIVENESS WHILE MAINTAINING ACCURACY

Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers TABLE OF CONTENTS

SPE The paper gives a brief description and the experience gained with WRIPS applied to water injection wells. The main

Cold-acclimatised pipelines

Wave Motion. interference destructive interferecne constructive interference in phase. out of phase standing wave antinodes resonant frequencies

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

TESTING BENCHES for watermeters

TechTalk. Purging for Delayed Coking. Understanding purging system design in heavy-fouling applications. Outline

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

Flow transients in multiphase pipelines

Fig. 2. M.I. Yaroslavtsev, 2002

Design DSA Steam-Atomized Desuperheater

EUROPEAN NEW CAR ASSESSMENT PROGRAMME (Euro NCAP) SLED TEST PROCEDURE FOR ASSESSING KNEE IMPACT AREAS

MARKET OUTLOOK. Power Chemicals Petroleum Water/Wastewater Oil & Gas Pulp & Paper and more

Fail Operational Controls for an Independent Metering Valve

Hazard Operability Analysis

RICK FAUSEL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

Instruction Manual. Pipe Friction Training Panel

Improve Process Reliability

Quick Installation Guide Doc nr.: C Date:

Author s Name Name of the Paper Session. Positioning Committee. Marine Technology Society. DYNAMIC POSITIONING CONFERENCE September 18-19, 2001

Safety Systems Based on ND Pressure Monitoring

23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN APRIL 2007

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

Journal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1)

Start-up of the Three-shaft Closed Loop

AN EVALUATION OF ENCAPSULATED OIL FLOODED SCREW COMPRESSOR SYSTEMS. Nikola Stosic, Ahmed Kovacevic, ian K Smith and Elvedin Mujic

Proof Testing A key performance indicator for designers and end users of Safety Instrumented Systems

The API states the following about tube rupture for a shell-and-tube heat exchangers:

MODELING&SIMULATION EXTRAPOLATED INTERNAL ARC TEST RESULTS: A COUPLED FLUID-STRUCTURAL TRANSIENT METHODOLOGY

Fluid-Structure Interaction Analysis of a Flow Control Device

AN31E Application Note

Fisher DSA Steam-Atomized Desuperheater

Thermal Mass Flow Controllers for High Accuracy Process Gas Applications

MANY REQUIREMENTS - ONE SOLUTION: SCENTY control

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

SHELL FLAGS INSPECTION CASE STUDY

Heat Pump Connections and Interior Piping

STANDARD PROCEDURE OF A TIGHTNESS TEST OF A SOLAR COLLECTOR BOX. (EUROSUN 2000 SOLAR CONGRESS)

EXPERIMENTAL RESULTS OF GUIDED WAVE TRAVEL TIME TOMOGRAPHY

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

The Science of Quantitative Risk Assessment for Explosives Safety

44 (0) E:

The Future of Hydraulic Control in Water-Systems

Engineering Letter. Pump Protection

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Effect of noise in the performance of the transducers in an ultrasonic flow meter of natural gas

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION

Design of a double quadruped for the Tech United soccer robot

Courses of Instruction: Controlling and Monitoring of Pipelines

Application of CFD for Improved Vertical Column Induced Gas Flotation (IGF) System Development

This test shall be carried out on all vehicles equipped with open type traction batteries.

Full scale measurements and simulations of the wind speed in the close proximity of the building skin

Every things under control High-Integrity Pressure Protection System (HIPPS)

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Tutorial. BOSfluids. Relief valve

Constant Pressure Inlet (CCN) Operator Manual

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

An innovative technology for Coriolis metering under entrained gas conditions

Transcription:

International Gas Research Conference 2014 TP3-12 433 Validating a dynamic grid model with tracer gas injection and analysis S.C. Brussel, R. Warmerdam, J. Weda, E. Hardi,T. van Onna, N. Ligterink, H. Blokland Liandon B.V. (part of Alliander N.V.), Liander N.V. (part of Alliander N.V.), Alliander N.V.,TNO The Netherlands Abstract Commissioned by Liander, the Dutch research institute TNO has developed a dynamic computer model of its gas grid. This model provides an insight how gas predictively flows through this grid, and is one of the building blocks toward making a smart grid. A combination of data from a variety of already present measuring devices, including flowmeters, pressure and temperature sensors, as well as information from static modelling software, was used to build this dynamic model. To validate the dynamic model a tracer gas test was conceived and executed. During this field test a traceable gas was injected in the gas grid, and analysers were attached to two gas pressure regulating stations further along the network to detect it. The spread and time of arrival of the tracer gas revealed how the gas actually travelled through the grid. This real-time information could then be compared with the virtual flow inside the model. A dry run of the test itself was done in Liander s Gas Test Facility, a grid bypass in 1

Amsterdam where in a controlled and monitored environment gas flows up to 14.000m(n)3/h and a pressure up to 8bar can be achieved. During this dry-run phase intimate working knowledge of all the necessary equipment - and the tracer gas itself - was gained, to minimise the risk of any unforeseen problems during the upcoming field test. The field test was designed in such a way that the gas grid itself does not have to be opened up and the live gas supply to customers remains uninterrupted. Existing valves, both under and above ground, where used to connect the equipment, or non-intrusive devices were used.the tracer gas test was a complete success and the Dynamic Grid Model was validated with it. The tracer technique itself is relatively simple and undisruptive to use and can be repeated indefinitely to fine-tune the model even further. Introduction A grid operators main responsibility is to maintain a safe and reliable gas grid. In the past gas quality in the Netherlands was never an issue becausethe gas always originated from one single supplier. However the upcoming growth of bio methane insertion in the Netherlands, forces the grid operators, like Liander, to gain better understanding of the gas flows and the gas quality in its grid. When off spec gas is detected somewhere in the grid, it is imperative to be able to trace the origin in order to prevent further contamination of the grid. Dynamic grid model Commissioned by Liander, the Dutch research institute TNO has developed a dynamic computer model of its gas grid. This model provides a predictive insight of how gas flows through the grid, making this model one of the building blocks towards the creation ofg a smart grid. A combination of data from a variety of readily available measuring devices, including flowmeters, pressure and temperature sensors, as well as information from static modelling software, was used to build this dynamic model. As a base, grid information stored in the Geographical Information System (GIS) of the grid operator, was used to construct a virtual representation of the grid. The simulations permit to use limited sensor readings to predict the flow inside a gas grid. Pressure, flow and mixture can be calculated at every location and at any moment in time. The calculation speed and accuracy of these calculations are critical requirements for this model. The simulation methodology used in this model is based on simulation techniques which uses quantum field theory for describing elementary particles. The main requirement is an explicit mass balance. The methodology (also known as direct integration) automatically confines the amount of gas within the grid. By using the relations in an explicit manner, the methodology is also very fast in comparison to other simulation techniques. A necessary condition for this fast simulation methodology is an upfront inventory of the grid. All nodes and loops between insertion points and customers must be known. 2

Validation project To ensure the model is producing accurate results, a validation location was chosen, in which field measurements were taken and compared to the results of the model. To validate the dynamic model a tracer gas test was conceived and executed. At the beginning of the validation project a series of steps were defined. 1. Finding a suitable location for the model validation test 2. Determining the exact insertion and analysis points in the validation grid 3. Designing and building a tracer injection and analysis installation 4. Testing the tracer injection and analysis installation in Liandon s Test Facility Gas 5. Installation and execution of the validation in the chosen grid 6. Running simulation using the boundary conditions measured during validation test 7. Analysing and comparing results gained from simulation and field validation test Model validation location The first task during the project was to find a suitable location within the grid, to be used as a test location. This location was found in the city of Haarlem. A section of the 4 barg transportation grid in Haarlem fulfilled the conditions set at the beginning of the test, being not too large or too complicated, with only a limited amount of boundary crossing points and containing at least one loop. North crossing South crossing Figure 1 Schematic representation of the chosen grid with only two boundary points The grid only crosses the chosen testing boundary at two locations, marked in figure 1 as north and south crossing. Inside the testing boundary lie several customers and gas reduction stations. Each of these points, as well as the boundary crossings will also have to be monitored. This is not an issue at the customers location due to the presence of gas meters used for billing purposes. The gas stations and gas lines at the crossings however are not monitored. Specific monitoring equipment had to be installed at these locations for the duration of this test. Injection and analysis points After the test location was found, the exact points for the injection of the tracer gas and the location for measuring flow and for placing the tracer gas analysers needed to be determined. Some locations had to be chosen carefully due to the presence of contaminated grounds in certain parts of the validation grid. Soil samples were taken and analysed to confirm the chosen locations were clean. 3

Designing and building a tracer injection and measuring system To measure the gas flow within the grid a variety of sensors and instruments are necessary. Tracer gas injection and analysis equipment Flow measuring equipment Tracer gas injection and analysis equipment The validation will take place using a tracer gas. After evaluating different ways of tracing, the choice was made for using CO 2 as the tracer gas. The main reasons for using CO 2 is the already natural occurrence of this component in Dutch natural gas and the fact that it is an inert gas. A rise of 1% on top of the already present CO 2 -concentration of 2-3% is more than enough to detect using a precise CO 2 analyser. For the injection of the CO 2 high pressure bottles were used. The bottles were connected to a buffer tank. Via a Bronkhorst High Tech In-Flow mass flow controller with a maximum capacity of 300 normal cube per hour the precise amount of CO 2 could be injected into the gas stream. To measure the tracer gas concentration, a S-AGM plus (single Advanced Gasmitter Plus) from Sensor Europe GmbH was used. To control the flow to the analyser a Bronkhorst High Tech flow controller with a maximum of 10 litres per minute was used at the inlet side of the analyser. Flow measurements To measure the flow within the grid different types of flow meters had to be used. At the boundary crossings the grid could not be disconnected, therefore the flow needed to be measured using clamp-on ultrasonic meters from General Electric, specially designed for gas flow measurements. Figure 2 Clamp-on ultrasonic flow meters (left photo: built onto a pipe line in the test facility ; right photo: built onto one of the pipe line in the field) The flows in the gas stations were measured using ST51 Thermal dispersion mass flow meters from FCI LLC. These meters could be mounted and inserted without the need of shutting down the gas supply through this station. 4

Testing the tracer injection and analysis installation in Liandon s Test Facility Gas Configuration In Liandon s Test Facility Gas a configuration was constructed to test the tracer injection and analyser installation. At the inlet side of the test setup the injection installation was connected to the main gas line. Figure 3 Schematic representation of the lab test setup, from right to left the tracer gas injector, the clamp-on flow meter and the tracer gas analyser Behind the injection point the clamp-on flow meter was installed. The clamp-on is used to measure the total flow from which the necessary amount of tracer gas can be calculated. At the end of the setup the analyser was connected. All components are controlled from the lab s control room. The pressure inside the setup was raised to 4 barg and a fixed gas demand of 2000 normal cubes per hour was created at the end side. A number of dry runs were performed to gain a better understanding in the interaction and accuracy s of the used components. This knowledge would later be used to minimise the risk of any unforeseen problems during the upcoming field test. Results The need for a tracer gas buffer tank became evident during the first lab test sessions, where oscillations occurred when a direct connection between the CO 2 bottles and the mass flow controller was used. The introduction of a buffer resolved this problem and added the possibility to attach more than one bottle. The experiment showed that a single CO 2 bottle was able to deliver a capacity of 23 normal m 3 /hr. During the field test higher tracer gas flows would be necessary meaning that at least four bottles would have to be connected simultaneously. A concentration rise of 1% was measured by the analyser after injecting a calculated amount of trace gas, which proofed that the chosen configuration was working perfectly and that the field tests could commence. 5

Installation and execution of the validation in the chosen grid Installation At the beginning of the field test, all the required measurement equipment had to be installed. To successfully validate the simulation model two teams were simultaneously operating at different locations. At one location a team was responsible for measuring the flow using the clamp-on technology and to calculate and inject the necessary tracer amount. Figure 4 Tracer gas injection point At the second location another team was responsible for the measurement of the concentration of tracer gas within the gas flow. These sample locations are depicted in figure 5 as DS01 and DS02. By means of telephone the exact moment of injection was passed on to the second team. Using rough calculation results from the model an estimation was available of the duration between injection and detection of the tracer gas. This was helpful in determining if the analyser was working accordingly. Figure 5 Schematic representation of the validation grid containing the flow values at each boundary point and the locations of injection and analysing of the tracer gas. 6

Results First measuring location The first two measurements were performed at gas station DS01, approximately 1,5 kilometres from the injection point. The first pulse arrived there after 6,5 minutes, the second try arrived after 5,5 minutes. Figuur 6 Measured tracer concentration values at the first analysing location The difference between the two values could later be explained due to a sudden increase in gas demand after the first measurement, leading to higher flows during the second measurement. The results also showed that almost no spreading of the pulse had taken place during transportation. De block pulse that was injected six minutes earlier arrived at the analysing location almost unchanged. This was not expected. This surprising result was afterwards explained using the Taylor dispersion theory for turbulent flows. The theory describes a direct relationship between pressure loss and dispersion at high velocities. The lower the pressure drop, the less dispersion takes place. This was also the case at the test side where high velocities and almost no pressure loss was measured. Second measuring location The third and fourth tracer gas measurement were made on gas station DS02. This station was located at approximately 2,5 kilometres from the point of injection. This meant that the expected time span between injection and detection would also be significantly longer than during the first two tests. Also due to the loop in this part of the grid, the tracer gas could flow via two seperate ways to the station. Measurements showed that the majority of the flow (97%) arrived via the main pipeline. The remaining 3% used the loop. Although no distinguishable concentration rise was expected through this loop, the results proofed otherwise. 7

Figure 7 Measured concentration pulses of tracer gas at the second analysing location The first pulse arrived at the gas station after 12 minutes, the second pulse took almost 32 minutes. The second try gave almost the same results, differing less than 2% of the first one. The deviating form at the end of the second pulse from one emptytracer gas bottle. The remaining bottlescould not provide the necessary amount of tracer gas needed and the increase of 1% could not be maintained anymore. Conclusion The tracer validation project was a success. The dynamic model, designed to predict flows, pressures and gas spreading in a 4 barg gas grid has been evaluated on the following points: The measured duration of a tracer gas pulse over a distance of several kilometres corresponds to the simulated value with a deviation far beneath 10%. Based on the measured duration values after the loop, the flow within that loop can be reconstructed with high accuracy. The measured tracer gas concentrations, being 1% of the total flow, are a near perfect match with the simulated values. This even counts for the concentrations after the loop, where the measured and calculated values were merely 0,04%. The spread of the pulse over time was limited, being a maximum of 20 seconds after five kilometres. This corresponds well with the calculated values. The flow within the grid moves like a clod. Almost no mixing occurs in the pipe lines. Mixing only takes place when two different flows merge. This results in the fulfilment of the main objective of this project, being the validation of a dynamic model for predicting flows, pressures and gas spreading. Next to this main objective much insight was gained in the different aspects concerning the managing of a natural gas grid. The field measurements for example gave different results for the flows in this part of the grid than what was anticipated by the grid operator. This clearly shows the importance of such models for gaining a better understanding of gas flows within a grid. 8