Agilent 1290 Infinity LC System Applications requiring the Agilent Ultra-Low Dispersion Kit

Similar documents
Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

Fast method for Ginseng Analyses using Agilent Poroshell 120 Columns Scaled from a Traditional Method

More Speed and Resolution for Current Methods

Video Notes. LC Troubleshooting Series Retention Time Shifts

Ensuring Best Possible UHPLC Performance Through an Innovative Capillary and Fitting Design

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Method Development Solutions

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Tips and Tricks of Faster LC Analysis Without Capital Investment It may be easier than you think! There Are Many Reasons to Reduce Analysis Time

Agilent Dimension Software for ELSD User Manual

LC, RSLC, Bio RS and Dual Gradient Systems

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

A Column-Flow Independent Configuration for QuickSwap. Application. Authors. Abstract. Introduction

Extended Application Note

Running HPLC Methods on an ACQUITY UPLC System

Agilent 1100 Series Analytical and Preparative Scale Fraction Collectors. User s Guide

Carrier Gases in Capillary GC

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

Carrier Gases in Capillary GC

SOP: Buck Scientific BLC-20P HPLC Operation

Agilent 1290 Infinity Pump Head Maintenance

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Agilent 1260 Infinity Purification Solution

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

no peaks missing peaks too small peaks increasing retention decreasing retention

Ascentis Express HPLC Columns with Fused-Core Technology

Trace-Level Analysis of Metanephrines in Plasma by HILIC LC-MS/MS

Best Practice for Identifying Leaks in GC and GC/MS Systems

Low-Pressure Retention Time Locking with the 7890A GC. Application. Authors. Abstract. Introduction HPI

UltiMate 3000 Viper Capillary Kits for Intelligent LC (LCi) System Solutions

6890 GC Site Preparation

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

Prep LC Training Manual

Agilent 7697A Headspace Sampler

FRANZ CELL TEST OF NANO GLUTATHIONE WITH HPLC ANALYSIS

Quantitative Analysis of Hydrocarbons by Gas Chromatography

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

BETTER SAMPLE CARE. Spark Holland introduces. SPH1299 UHPLC Gradient Pump

User Manual. Agilent 1260 Infinity Analytical- and Preparative-scale Fraction Collectors

Retention Time Locking: Concepts and Applications. Application

DOS in Food Science & Nutrition, Manasagangotri, Mysore

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

The instrument should have a mass range from 2 to 2000 m/z or better Interface

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

HPLC troubleshooting guide

International Journal of Generic Drugs ANALYTICAL METHOD PROCEDURES THIS SOP IS 'SWITCHED : OFF : ON'

Prep LC Training Manual S.V.

Setting a New Standard in Flash Chromatography Performance

Fused-Core TM Particle Columns provide UHPLC performance on any HPLC

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

GCMSD-Headspace Analysis SOP

The instrument will process the samples one by one till all the samples have been cleaned up.

1290 Infinity II Preparative Open-Bed Fraction Collector

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Customer Responsibilities

Agilent G3180B Two-Way Splitter Kit

A NOVEL RP-HPLC METHOD FOR THE QUANTIFICATION OF ICATIBANT IN FORMULATIONS

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Considerations and Best Practices for Maintaining Your Agilent GC s Split/Splitless Injection Port

Agilent G3185B QuickSwap Accessory

User Manual. Agilent 1260 Infinity Micro-scale Fraction Collector/Spotter

Extend the time window for the detection of low level anabolic androgenic steroids and their metabolites

5890II GC Standard Operating Procedure 9/2/2005

High speed UHPLC-MS/MS determination of multiple steroids in human serum using the Nexera MX system for multiplex analysis

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 5975C MSD Series G3170A, G3171A, G3172A, G3174A

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Peak Biotech - Company & Product Presentation

SOP: Derivatized testosterone_01 Revision: 01 Date Effective: 05/17/15

SHIMADZU LC-10/20 PUMP

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Recent Advances to Ensure Simple, Leak Free GC Column Connections. Ken Lynam R&D/Application Chemist Agilent Consumables and Supplies Division

Technical Procedure for Drug Chemistry Gas Chromatograph/Mass Spectrometry (GC-MS)

The Application of QuEChERS in the Extraction of Anabolic Steroids in Whole Blood

Precisely HPLC. Hints, Tips, Guidelines and Important Considerations. Presenters: Wilhad Reuter / Tom Breslin

Impact of Air Leaks on the Productivity of GC and GC/MS Systems

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

Operation of the Perkin Elmer TGA-GC/MS

Agilent G Rebuilt Electron Capture Detector

Thermo Scientific Chromatography Well Plates

Thermo Scientific Chromatography Well Plates

Pre-installation Checklist

The. «Modular Alliance» Gas Generators. ALLIANCE, the partnership that keeps the gas flowing. One step ahead!

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

Capillary Conversion System CCS-4/NC & CCS-05/NC. Installation and Operating Instructions. Operating Instructions

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Supporting information for J. Med. Chem., 1994, 37(5), , DOI: /jm00031a018

May 1, By John Heim,Doug Staples

ZEFIRO series NITROGEN GENERATORS. The constant and completely autonomous supply of nitrogen flux DESIGN AND PRODUCTION OF LABORATORY GAS GENERATORS

CORESTA RECOMMENDED METHOD Nº 67

DEBUBBLERS & DEGASSERS ACTIVE DEBUBBLERS APPLICATION NOTE WHY DEGAS YOUR MOBILE PHASE? PAGE 177 STAND ALONE DEGASSERS PAGE 175 PAGE 178

Varian 3300 Gas Chromatograph Abbreviated Operating Instructions

Figure 1: Plug in ion inlet of mass spec

Transcription:

Agilent 19 Infinity LC System Applications requiring the Agilent Ultra-Low Dispersion Kit Technical Overview Author Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany mau 15 1 1 3 1 All components kit without flow cell 3 No 5..3.4.5.6.7 min Abstract Improvements with respect to peak width, peak capacity, and plate number were evaluated using the Agilent Ultra-Low Dispersion Capillary Kit and the Agilent Ultra-Low Dispersion Flow Cell for the Agilent 19 Infinity LC System. Based on the experimental results presented in this Technical Overview, we recommend using the Ultra-Low Dispersion () Kit for short runs with 5-mm columns, especially for columns with.1-mm and 3-mm id. For longer runs with.1-mm and 3-mm id columns, the improvements using the kit were negligible. However, for 1-mm and 15-mm 4.6-mm columns, the increased pressure, for example, due to smaller capillary ids, exceeds the limit of 6 bar for sub- µm 4.6-mm id columns when used with gradient runs. Therefore, the kit is not compatible with these columns or for long gradient or low-organic isocratic runs.

Introduction Extra-column volume leads to dispersion and therefore increased peak widths and lower peak heights. Depending on the columns used, the effect can be observed in different degrees. The extra-column volume is defined by the International Union of Pure and Applied Chemistry (IUPAC) as the volume between the effective injection point and the effective detection point, excluding the part of the column containing the stationary phase. It is composed of the volumes of the injector, connecting lines, and detector. Equation 1 displays the ratio of the extra-column dispersion (s col ) and the column dispersion (s ex ) to the total dispersion (s tot ). s tot = (s col + s ex ).5 Equation 1 Extra-column dispersion is especially critical for low id columns, because it accounts for a higher percentage of the total extra-column volume of the system. The Ultralow Dispersion () Capillary Kit in combination with the Agilent Max-Light Ultra-low Dispersion Cartridge Flow Cell reduces the extracolumn volume of the LC system to a minimum using 75-µm capillaries and a flow cell with V(s) =.6 µl instead of V(s) = 1 µl. This Technical Overview shows the effect of low dispersion components on factors such as peak width and resulting calculations of peak capacities and plate numbers for different common column ids and lengths (4.6, 3, and.1 mm 5, 1, and 15 mm) with the Agilent Eclipse Plus stationary phase for isocratic and gradient runs. The results of these experiments, provide recommendations as to which applications require the components for better chromatographic results. Experimental Instruments The Agilent 19 Infinity LC System consisted of the following modules: Agilent 19 Infinity Binary Pump (G4A) with 35-µL Jet Weaver Agilent 19 Infinity Autosampler (G46A) Agilent 19 Infinity Thermostat (G133B) Agilent 19 Infinity Thermostatted Column Compartment (G1316C) Agilent 19 Infinity Diode Array Detector (G41A), equipped with a standard 1-mm flow cell Agilent Ultra-Low Dispersion Capillary Kit (567-5189) Agilent Max-Light Ultra-Low Dispersion Cartridge Flow Cell V(s) =.6 µl, 1 mm (G41-638) Columns Agilent ZORBAX Eclipse Plus C18, 4.6 15 mm, 1 mm and 5 mm, 1.8 µm Agilent ZORBAX RRHD Eclipse Plus C18, 3 15 mm, 1 mm and 5 mm, 1.8 µm Agilent ZORBAX RRHD Eclipse Plus C18,.1 15 mm, 1 mm and 5 mm, 1.8 µm Software Agilent OpenLAB CDS ChemStation Edition for LC & LC/MS Systems, Rev. C.1.3 [3] Solvents and samples Solvents: A = H O dd B = acetonitrile For isocratic runs: 7% acetonitrile and 3% H O dd Samples: RRLC Checkout Sample (p/n 5188-659) including acetophenone, propiophenone, butyrophenone, valerophenone, hexanophenone, heptanophenone, octanophenone, benzophenone, and acetanilide All solvents used were LC grade. Fresh ultrapure water was obtained from a Milli-Q Integral system equipped with a.-µm membrane point-of-use cartridge (Millipak).

Chromatographic conditions Time (min) % B Gradient 3 x 95 5 mm and 5 1 mm 1 15 mm Post time 1 Isocratic with 7% B 5 mm 1 mm 3.3 15 mm 5 Flow rate 4.6 mm.4 ml/min 3 mm 1 ml/min.1 mm.5 ml/min Injection volume 4.6 mm µl 3 mm.9 µl.1 mm.4 µl Thermostat 4 C Column temperature 5 C UV 45 nm/1 nm Ref.: 4 nm/1 nm Peak width.63 min (.13 s response time) (4 Hz) 3

Results and discussion The reduction of the extra-column volume by using the components was evaluated with the RRLC standard sample consisting of a mix of nine phenones (see Figure 1). The effect of the capillary kit (including capillaries, needle seat and heat exchanger) is displayed in Figure for the first peak, demonstrating the effective reduction of peak width, which results in sharper and more intense peaks. The use of the flow cell increased this effect. Peak width reduction, due to the use of the components (both capillary set and flow cell), was significant especially for the first peaks in a fast -minute gradient using a.1 5-mm column as shown in Figure 3. The mean peak widths at 5s were used for all graphics and calculations of peak capacity for gradient runs. mau 175 15 15 1 75 5 5 Figure 1 RRLC sample. mau 15 1.5 1 1.5.5 3 1 3 1 All components kit without flow cell 3 No min 5..3.4.5.6.7 min Figure Overlay peak 1 showing the advantages of the components for.1 5 mm, 1.8 µm with a -minute gradient. Peak width (min).5.45.4.35.3.5..15.1.5 Peak width.1 5 mm - -minute gradient 3 4 5 Peak 6 7 8 9 No Figure 3 Comparison of peak widths for.1 5-mm column with a -minute gradient with and without components. 4

n was calculated using Equation (t p = time from first to last peak, w 5s = mean peak width at 5s). 7.1 5 mm - -minute gradient n = t p w 5s Equation Figure 4 shows the increase in peak capacity with the use of the components compared to the standard capillaries and flow cell. Note that an improvement of 5% in peak capacity can be achieved with the components for short -minute gradients with.1-mm id columns and 5-mm length. Using the components, the peak width was reduced, leading to sharper and more intense peaks. However, depending on the application, the flow cell with an internal volume of.6 µl might show increased noise values due to the reduced diameter. Figure 5 shows the signal-to-noise (S/N) ratios of all nine peaks of the short -minute gradient with.1 x 5 mm columns. The improvement of S/N, as seen for the first peak is not consistent for the residual eight peaks. The increase in peak height due to reduced peak widths with the components does not compensate the increase in noise of the flow cell for all peaks. 6 5 4 3 1 no Figure 4 for.1 5-mm columns with -minute gradients. S/N 8 7 6 5 4 3 1 Signal-to-noise ratios.1 5 mm - -minute gradient 3 4 5 Peak + 5 % Figure 5 Signal-to-noise ratios of the RRLC sample using.1 5-mm column with a -minute gradient. 6 7 8 9 No Figure 6 shows an overview of the calculated peak capacities of.1-mm columns of different lengths for gradient runs. The shorter the run (and the shorter the column), the bigger the effect resulting in increased peak capacity especially for the -minute runs with the.1 5-mm column. 14 1 1 8 6 4 + 5 5 %.1-mm columns with gradients + 14 % + 14 % + 8 % + 8 % + % No 5 mm min 5 mm 5 min 1 mm 1 min 15 mm min Figure 6.1-mm columns. 5

This effect is evident with short gradients using 5-mm length columns with 3-mm id, but decreases strongly for longer gradients to % improvement for 15-mm columns with -minute gradients (see Figure 7). 16 14 1 3-mm columns with gradients + % + % For short runs with 4.6-mm id columns, a small improvement is still shown (Figure 8). However, the gradients runs with 1-mm and 15-mm columns could not be conducted due to the 6-bar pressure limit of the column. Generally, 4.6-mm id columns with a particle size of sub- µm are limited to a pressure of 6 bar. With the implementation of the components, the pressure increased more than double especially with the high flow rates used with the 4.6-mm id columns (see Figure 9). 1 8 6 4 + 18 % 5 mm min Figure 7 3-mm columns. 7 6 5 4 3 + 16 % 5 mm 5 min + 15 % 1 mm 1 min 4.6 5-mm column with gradients 15 mm min + 13 % No 1 5 mm min 5 mm 5 min Figure 8 4.6 5-mm columns. mau 35 3 5 15 1 5 1 3 Backpressure 1 All components max. 55 bar kit without flow cell max. 46 bar 3 No max. 7 bar.5 1 1.5.5 3 min Figure 9 Increase in backpressure using the components - 4.6 5-mm column with gradient. 6

For the evaluation of isocratic runs, the plate number N was calculated according to Equation 3 (RT = retention time, w 5 = peak width at half height) and averaged over all nine peaks. N = 5.54 * ( RT ) Equation 3 w 5 For isocratic runs, the improvement of the calculated plate number was prominent for the.1-mm id columns, especially for the short runs, with 5-mm id columns (Figure 1). For short isocratic runs, use of 3-mm id columns produced an improvement of 3%. For 1-mm and 15-mm, 3-mm id columns, and for all 4.6-mm id columns, no significant effect regarding peak width and plate number was observed. Figure 11 shows an overview of 4.6-mm and.1-mm id columns regarding plate number in isocratic runs. Note that larger id columns typically lead to higher plate numbers compared to smaller id columns for any given extra-column volume, whether the volume reduced using the kit or not. Therefore, for highest separation performance, larger id columns are preferred. % Plate number improvement 75 bar 43 bar 54 bar 6 bar 41 bar 5 bar 1 4.6 mm 3 mm Column id Figure 1 Improvement plate numbers isocratic runs with. Plate numbers 8 7 6 5 4 3 1 3 5 15 1 5 14 Improvement in plate number with 3 15 14 Plate numbers with 5 1 Column id 69 198 bar 49 4 bar.1 mm 15 4 495 bar 5 mm 1 mm 15 mm 4.6 mm.1 mm Figure 11 Plate numbers from isocratic runs with. 7

Conclusion The effects of the Ultra-Low Dispersion Kit (both capillaries and flow cell) were evaluated with respect to peak width, and as a result, plate numbers and peak capacity. Figure 1 illustrates the recommendations for the use of the kit, based on the experiments in this Technical Overview. The green color represents highly recommended, green-hatched highly recommend for isocratic runs, yellow conditionally recommended, red not recommended. The Ultra-Low Dispersion Kit (both capillaries and flow cell) shows the best effects, regarding plate numbers and peak capacities, when used for short runs with 5-mm columns, especially for.1- and 3-mm id. For short.1-mm id gradient runs, the improvement in peak capacity was about 5%, whereas the improvement in plate number for.1-mm id columns was calculated as 69%. For longer isocratic runs using.1-mm id columns, the improvement in plate number was 49% for 1-mm and 4% for 15-mm column length. The price for this improvement is a slight loss in sensitivity due to increased noise of the flow cell. The improvements due to the kit are negligible for.1- and 3-mm id columns regarding long gradient runs, but the kit does not interfere with the analysis as the pressure limits of the used columns are 1, bar. However, for 1-mm and 15-mm 4.6-mm id columns, the pressure reaches or even exceeds the limit of 6 bar of sub- µm 4.6-mm id columns when used with gradient runs. Therefore, the kit is not recommended for these columns and long runs (gradients or low-organic isocratic runs). Column id.1 mm 3 mm 4.6 mm In summary, the kit is highly recommended for short runs (gradient and isocratic) using.1-mm and 3-mm id columns (Figure 1, green boxes) and also for long isocratic runs with.1-mm id columns (Figure 1, green-hatched boxes). 5 mm/short 1 mm/long 15 mm/long Column length/run time Figure 1 Overview improvements with for sub- µm columns (green highly recommended, green-hatched highly recommend for isocratic runs, yellow conditionally recommended, red not recommended). www.agilent.com/chem/ bio-inert Agilent Technologies, Inc., 1 Published, July 1, 1 Publication Number 5991-86EN