Operation Manual ARTICEL SunSun CUF SunSun CUF SunSun CUF-6000

Similar documents
Airbrush Diaphragm Compressor AS06

Operation Manual Airbrush Compressor AS196A ARTICLE 34207

Operation Manual Airbrush Compressor AF18-2 ARTICLE 34203

Operation Manual Airbrush Compressor AF186 ARTICLE 34208

XPOSE UV-C QUICK INSTALLATION GUIDE

03/07/2014 V

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Cocoa Patio Pond with Lit Spillway

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

CUT OFF TOOL MODEL: CAT113

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

PRAHER PLC-MP AQUASTAR MANAUL 2009

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

Budget Range Operators Handbook

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

ATS430 turbidity sensor Retractable insertion assembly

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

3/8" Dr. Air Butterfly Impact Wrench

Instructions for use Compressed air injector with water trap

Endura AZ40 Sensor assembly Smart electronics PCB

OWNER S MANUAL. Page: 1 of 8

AIR/OVER HYDRAULIC JACK 20 TON

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Endura AZ40 Sensor assembly High temperature filter assembly kit

Innovative Vacuum for Automation. Operating Instructions Dust Filter STF P / STF-D P.

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

[ACT 005] Manual E 5/25/05 9:24 PM Page 3 MULTI-FUNCTION

User Guide for. UTR Turbo Air Lappers Pneumatic Air Grinders & Lappers UTR-30, UTR-70, UR , ,

200L BELT DRIVEN AIR COMPRESSOR

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

FPD20 Series. Gear wheel flow sensor

1/4 SHEET PALM SANDER

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Code AWC20HP Air Compressor

Safety instructions and operating manual

accidents which arise due to non-observance of these instructions and the safety information herein.

USER MANUAL. JET TST and JET TST S.

80 Litre Suction Oil Drainer

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

1 DRIVE INDUSTRIAL IMPACT WRENCH

444C DUAL PERFORMANCE VALUE PACK

Fiber Cable Puller with Tuf-Lugger lite

50L BELT DRIVEN AIR COMPRESSOR

Installation and Operating Instructions Bypass Flow Meter DST

Pre-filter for Brushless Blower Instruction Manual

Type BBS-03, BBS-05, BBS-06, BBS-25

Installation, Operation & Maintenance Instructions

Operating Instructions Part No

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SOVEREIGN W Electric Hover Mower (Model: MEH929)

Med Aire Alternating Pressure Pump and Pad System

Pressure relief valve

4 ANGLE GRINDER MODEL NO: CAT 52 PART

COMPACT AIR COMPRESSOR MODEL NO OWNER S MANUAL

Storage Shelving. User Manual [Revision 3.0 May 2017]

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

SC100V AIR COMPRESSOR

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Achat 112 mid-high-range speaker. user manual

Operating and maintenance manual Filter and reducing station Series / 1.0

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

12V AIR STATION ALL-IN-ONE

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

Pressure relief valve

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

DK46 - DK800 Supplementary instructions

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

ST1600 SAND FILTER PUMP

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Steel Spring Driven Reel Instruction Manual

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Airmate TS1.5/6 Oil-less Air Compressor

AIR COMPRESSOR MODEL NO: CHAMP

400C & 450C DUAL PERFORMANCE VALUE PACKS

INTENDED USE TECHNICAL SPECIFICATIONS

3hp. model no: SAC10030VE

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

UsER manual for Watersens ph -REDOX

New AQF Filter Polymer Filtration System

Aquatics. Spares Manual February 2017

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Operating Instructions Part No

TEM# Air Hammer Combo USER'S MANUAL

EG15*... SERIES. SOLENOID GAS VALVES WITH 1/2 CONNECTION AND OPERATING PRESSURE UP TO 500 mbar DESCRIPTION

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

INSTALLATION / USER MANUAL Wallom2 mobile lift HEY YOU, LET ME HELP! Share, inspire, have fun! With CTOUCH by your side.

30T A/Manual Hydraulic Shop Press

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

Transcription:

Operation Manual ARTICEL 50945 SunSun CUF-2500 50946 SunSun CUF-5000 50947 SunSun CUF-6000 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments, illustrations, functioning steps and technical data can differ insignificantly. Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us. by WilTec Wildanger Technik GmbH Seite 11

The information contained in this document is subject to change without prior notice. No part of this document can be copied or duplicated in another form without the prior written consent of Wiltec Wildanger Technik GmbH. The Wiltec Wildanger Technik GmbH assumes no liability for any errors in this user manual or the connection diagram. Although Wiltec Wildanger Technik GmbH has made every effort to make sure that this user manual is complete, accurate and updated, errors cannot always be avoided. In the event of problems with this user manual please complete and send this form back to us. FAX-notification (+++49 2403 55592-15), from: Name: Firm: Tel/Fax: I would like to report the following mistakes: Customer Service Wiltec Wildanger Technik GmbH e-mail: service@wiltec.info Tel:++ +49 2403 55592-0 Introduction Thank you for purchasing this quality product. To minimize the risk of injury by means of fire or electric shock we urge that our clients take some basic safety precautions when using this device. Please read the operation instructions carefully and make sure you have understood its content. Always use a grounded power connection with the appropriate mains voltage. You can find the corresponding mains voltage on the type plate. If you have any doubts about the connection being grounded, have it checked by a qualified professional. Never use a faulty electric cable. Do not inspect the electrical part of the pressure pond filter in a wet or damp environment or when you are wet yourself and protect it from direct sunlight. Install this device in a safe location so that nobody can step on the cable, fall over or damage it. Disconnect the power plug before cleaning it and use only a damp cloth for cleaning. Avoid using cleaning agents and make sure that no liquid enters the electrical part of the pump. The electric part of the device contains no parts that can be inspected or serviced by the user. Leave the maintenance, adjustment and repair to qualified technical personnel. In case of unauthorised intervention the 2-year warranty is no longer valid! Keep these operation instructions safe. by WilTec Wildanger Technik GmbH Seite 12

Before the first time use, please read this instruction and acquaint this equipment. In order to use the equipment safely, the following secure suggestions should be abided. Caution CUF is UV clarifier equipment which can be fixed. It contains water pu,p and one piece of UV lamp. Any damage on the equipment or unmerited operation will bring dangerous radiation to the skin and eyes. So if there is any damage of the equipment, it cannot be used any more. This equipment is not intend for use by persons (including children) with reduced physical, sensory of mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the equipment by a person responsible for their safety. The equipment should be placed out of children reach. For the consideration of security, people younger than 16 years old and those who cannot identify danger or grasp the instruction cannot use the equipment. This equipment should be placed under the water. Be sure the equipment is submerged completely in the water and the deepness should not bigger than 2m. Before the water submerge the equipment, please never plug in to avoid the equipment working without water which will bring damage to the equipment. The equipment is a kind of fixed appliance with rubber feet under it which can help the eqiupment to fix on the slippy surface (such as glass and so on); Because the UV lamp is made of quartz glass, please avoid drop of it or wallop on it. The detailed information about installation, please check the instruction information. Before all parts are installed completely, the equipment cannot be plugged in. If there is any damage on the power cable, UV lamp or shell, the equipment cannot be used. And it should be discared as useless. When any person in the water, the equipment cannot be used. Please make sure that the electrical voltage, frequency used are consistent with the indication on the label of the equipment. When installing the equipment, the installation regulation of domestic should be followed The equipment should be earthed, And the professional person should check the condition of earthed. For the considered of safety, we advise customer to install creepage protector in order to make sure the electric current will not exceed 30mA. Pull in the connecting cable is forbidden. And please keep the connecting cable away from heat, greasiness or sharpness. Make sure the max. pressure of the bod shell endured is less than 0.3 bar. When know the frost is coming, please move away UV filter. The dirtiness on the quartz tube will influence the effect of the equipment, please clean the quartz tube in time. In order to ensure the effect of the equipment, the UV light tube should be replaced after 8000 hours' usage. When the body shell is blocked with the sands and rubbish, it is possible to destroy the quartz tube. So please add the filter sponge in the inlet of the water. And the sponge should be cleaned in time (one month one time). U'VC is harmful to the eyes and shin. Please do not watch UVC directly or let the shin approach to the UVC. When Install or repair this equipment, the electrical source of the aquarium must be switched off. Applicability & Technical Parameter This series equipment are suitable for aquarium and pond filter the water. They cannot used in the swimming pool. The major technical parameter is as follows (The Max. water pressure: 2M, Too big pressure will damage the equipment.) by WilTec Wildanger Technik GmbH Seite 13

ITEM VOLTAGE POWER UVC LAMP H-MAX Q-MAX OUTLET CUF-2500 220-240V/50HZ 28W 9W 1.6M 1000L/H 1/2-3/4-1 CUF-5000 220-240V/50HZ 42W 9W 2.0M 2000L/H 1/2-3/4-1 CUF-6000 220-240V/50HZ 54W 9W 2.5M 2500L/H 1/2-3/4-1 by WilTec Wildanger Technik GmbH Seite 14

PART LIST 1 Outlet 9 Filter base 17 O-ring 2 Elbow pipe 1 10 adapter 18 Connection pipe 2 3 Filter cover 11 Water pump 19 nut 4 sponge 12 Fountain head(tent type) 20 flange 5 UV-C lamp 13 Fountain head(rain type 1) 21 T-joint 6 Elbow pipe 2 14 Fountain head(rain type 2) 22 screw 7 Filter boxes 15 Fountain sets base 8 Runner plate 16 Connection pipe 2 by WilTec Wildanger Technik GmbH Seite 15

5-1 UV-C lamp shell body 5-5 45*4 o-ring 5-9 UV-C device head with cable 5-2 Spiral sleeve 5-6 Quartz glass tube sleeve 5-10 Safety clasp 5-3 Quartz glass tube 5-7 60*3.1 o-ring 5-4 Fasten screw 5-8 Uvc bulb 11-1 Impeller cover 11-3 rotor 11-5 shaft 11-2 Rubber bearing 11-4 O-ring 11-6 Shell body by WilTec Wildanger Technik GmbH Seite 16

CAUTION CUF is UV-C clarify equipment which can be combined. It contains water pump and one piece of UV-C lamp. Any damage on the equipment or unmerited operation will bring dangerous radiation to the skin and eyes. So if there is any damage of the equipment, it can not be used any more. This equipment is not intend for use by person (including children) with reduced physical, sensory of mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the equipment by a person responsible for their safety. The equipment should be placed out of children reach. For the consideration of security, people under 16 years old and those who can not identify danger or grasp the instruction can not use the equipment. 1.This equipment should be placed under the water. Be sure the equipment is submerged completely in the water and the depth should not be greater than 2m. 2.When the water is not enough to submerge the equipment, please never connect power of the equipment to avoid running without water and cause damage. 3.As the UV-C lamp is made of quartz glass, please avoid drop of it or wallop on it. 4.Before all parts are installed completely, the equipment can not be plugged in. 5.If there is any damage on the power cable, UV-C lamp or shell, the equipment can not be used. And it should be discarded as useless. 6.Please make sure that the electrical voltage, frequency used are consistent with the indication on the label of the equipment. 7.When installing the equipment, the installation regulation of pond pumps should be followed. 8.The equipment should be earthed. And the professional person should check the condition of earthed. For the considered of safety, we advise customer to install leakage protector. 9.Pull the connecting cable is forbidden. And please keep the connecting cable away from heat, greasiness or sharpness. 10.When the pump have any unusual noise, please unplug to check the reason. 11.When know the frost is coming, please move away UV-C filter to avoid frost crack. 12.The dirtiness on the quartz glass tube will influence the effect of the equipment, please clean the quartz glass tube in time. 13.When the body shell is blocked with the sands and rubbish, it is possible to destroy the quartz glass tube and water pump. So please add the filter sponge to the inlet of the water. And the sponge should be cleaned timely. (once a month). 14.UV-C is harmful to the eyes and skin. Please do not watch UV-C directly or let the skin approach to the UV-C. 15.When install or repair this equipment, the electrical source of the equipment must be switched off. INSTRUCTION 1.This equipment built-in filter sponge, biochemical basket, UV-C lamp and water pumps. This equipment adopt reasonable water channel, suitable for both indoor, outside pond garden, aquatic breeding, clean water sterilization and water fountains. 2.Through the working of water pump, water flow from the filter cover to filter sponge, and then to the UV-C lamp. Inside of the UV-C lamp the harmful bacteria and algae will be killed. Then the water flow to outside finally. 3.The UV-C lamp was designed as a closed device, no UV-C will scattering. And UV-C light 253.7nm will kill the harmful bacteria and algae to keep a good condition of water. INSTALLATION AND MAINTENANCE Please switched off the electrical power when you clean the inside or change the UV-C lamp. When clean the inside or change the UV-C lamp, please take below part list as your reference. INSTALLATION Connect No.15-16-17-20-21 together, choose a suitable fountain head from 12-13-14 and connect to No. 15. Then connect fountain set to No.10. Adjust the height of the fountain set and submerge the equipment under water. If only need this equipment to take water, you can only connect No. 1-2, no need fountain set. by WilTec Wildanger Technik GmbH Seite 17

MAINTENANCE Maintenance for filter sponge and filter material 1. Take of the fountain set, unload the screw No, 22, and open the two clips on the side of the filter cover, then you can open the filter cover. 2. Take out the filter sponge and filter material boxes, clean or change these. (suggest to clean the filter sponge every week) MAINTENANCE FOR UVC-LAMP 1. Take out the UV-C lamp and open the safety catch, turn the shading cylinder components (NO. 1-2- 3-4-5-6) in anti-clockwise direction till the block position, then pull out the quartz glass tube. Now you can change your UV-C lamp. 2. If you need to clean the quartz glass tube, please take out the components inside of the shading cylinder, unload the screw No.4. Then you can take out the quartz glass tube and clean it. MAINTENANCE FOR WATER PUMP 1. turn impeller cover in anti-clockwise direction till the block position, then you can separate the the impeller cover and pump body. 2. Take out the impeller, clean it with clean water and suitable brush. Storage in winter 1. Take out the equipment from water 2. Clean the equipment thoroughly 3. Check the parts and conditions of the equipment 4. Keep this equipment in a area that free from frost. And in a container that with clean water by WilTec Wildanger Technik GmbH Seite 18

Disposal regulations EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2002/96/EC) were implemented in the law related to electrical and electronic equipment and appliances. All Wiltec electric devices that fall under the WEEE regulations are labelled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the domestic waste. The company Wiltec Technik GmbH has been registrated in the German registry EAR under the WEEE-registration number DE45283704. Disposal of used electrical and electronic appliances (intended for use in the countries of the European Union and other European countries with a separate collection system for these appliances). The logo on the article or on its packaging points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment. By contributing to the correct disposal of this article you protect the environment and the health of your fellow men. Environment and health are threatened by inappropriate disposal. Materials recycling helps reduce the consumption of raw materials. Additional information on recycling this article can be provided by your local community, municipal waste disposal facilities or the store where you purchased the article. Address: WilTec Wildanger Technik GmbH Königsbenden 12 / 28 D-52249 Eschweiler Important notice: The reprint or reproduction, even of excerpts, and any commercial use, even in part of this instructions manual require the written permission of Wiltec Wildanger Technik GmbH. by WilTec Wildanger Technik GmbH Seite 19