Explosion Isolation. No matter what happens - nothing happens. / RICO Slide Valve RSV-D, RSV-G, RSV-P

Similar documents
6-5 Maintenance Manual

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

KLINGER CONAXE Double Offset High Performance Butterfly Valve DN

IS YOUR FLAP VALVE IN COMPLIANCE WITH NFPA ?

New Findings for the Application of Systems for Explosion- Isolation with Explosion Venting

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.

ST/SG/AC.10/C.3/2016/8. Secretariat. United Nations. Transport of gas tanks for motor vehicles. Introduction

Low-Pressure Airjet-Filter MVRT

CR Series. Special doors for clean room application

Tubes Components Valves Units Engineering SO EVERYTHING KEEPS FLOWING. Safety valves Bunging valves Vacuum valves Tank dome fittings

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

SAFE AND ENVIRONMENTALLY FRIENDLY

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

High Pressure Tube Unions

M A B MAB INFLATABLE GASKET SLIDE VALVES SERIES TSV FOR POWDERED AND GRANULAR SOLID MATERIALS

Workshop Compressors CLASSIC Series

Transport of gas tanks for motor vehicles

PV-ECO SERIES. High velocity pressure/vacuum valves MARINE LIFE WITHOUT FOOTPRINTS

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

THE WATER-COOLED INDUSTRIAL RANGE

SMART Explosion. Efficient Boiler Cleaning with Explosion Generators

2/2-Way and T Valve Bodies in Stainless Steel

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Valvex Valves for Mining Applications

Type overview. R B2 en-gb subject to changes 1

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

KOMPRESSOREN COMPRESSORS KAESER AIR SERVICE Our Services An Overview

Since 1946: Innovation and reliability combined. Slide gate valves for the industry made in Germany.

STINGER SERIES INLET ISOLATION VALVES

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. C Series Range. Pressure Reducing Valves. Broady Flow Control

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

Level switches Series LD Vibrating fork level switch for liquids and solids

The Original Dome Valve Range

Magnetic level switch type MR783 Instruction Manual

Innovative Pressure Testing Equipment

For the cleanest tablets and capsules

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

BUCKET ELEVATORS 1 BUCKET ELEVATORS. Technical Data for Bucket Elevators (BW)

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

SAMPLING SYSTEMS FOR LIQUIDS AND GASES FOR ALL TYPES OF APPLICATIONS

BASIC BROEN-LAB UNIFLEX LIFT/TURN VALVES FOR BURNING GASES

SAFE/REYCO. More than 35,000 variations in DIN EN and ASME. NEW! Now with zero leakage in combination with SHR premium soft seal* (now up to +220 C)

Oil & gas. Safe Reliable. Pumps. Pumps. CSA Accessories. Toll Free: Int'l:

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

II 2G EEx ia IIC T6. Ignition protection class

A guide to Part 10 of the

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Valves. Diaphragm shut-off valves, kidney-type

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

Level switches Series LD Vibrating fork level switch for liquids and solids

W E NE E D TO TA LK A BOUT COLD FLOW. The Problem With The Cold Flow Standard.

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Gas Pressure Regulator R 51

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Cellular Gas Filters DF 100. Product Information

STANDARD HIGH PRESSURE COMPRESSORS COMPACT PACKAGE FOR DEMANDING APPLICATIONS

Gas Pressure Regulator HON 300

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Water Solenoids Safety Valves Air. Meters. Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

Materials : Stainless steel ASTM A351 CF8M

WHITEPAPER: ATEX IN PRACTICE (EXPLOSION PROTECTION)

Workshop Compressors CLASSIC Series

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. D Series Range. Pressure Reducing Valves. Broady Flow Control

Pressure/Vacuum Diaphragm Valve PROTEGO UB/SF. deflagration- and endurance burning-proof

CALIFORNIA STATE UNIVERSITY, LOS ANGELES WELDING, CUTTING, AND HOT WORK OPERATIONS. October 2007

INDICATIONS FOR CHOICE OF ATEX FANS

AMT-Ex Dewpoint Transmitter

Gas Filters DN15 DN300. elektrogas.com EE151 06/13

Good things come in threes

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

BULK SOLIDS HANDLING Valve Solutions Unlock the Potential

Pressure Piping Code-Industrial Piping. Part 6: Safeguarding

EasyLine Continuous Gas Analyzers. So smart, they re simple

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

CAST IRON SAFETY VALVE TYPE 6301

Pressure control, differental pressure control and thermostat Type RT

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

High Pressure Asher HPA-S

DK46 - DK800 Supplementary instructions

Confined Space. A Death Trap in Waiting. Technical Article

Pressure switch, Differential pressure switch and Thermostat RT-E

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens.

Success Paths: A Risk Informed Approach to Oil & Gas Well Control

Working in Gas Hazard Areas

Class 1 Cartridges and Filters for use with Honeywell Twin Filter half and full-face masks We listened to you. Respiratory Protection

OPERATION MANUAL PNEUMATIC VALVES

Electronic Turbine Meter TERZ 94

TP1 and TP2 Temporary Cone Shaped Strainers

Gebrüder Dreher Drehteile & Gasfedern GmbH

Pressure Switches Application Guideline

Quick Specs. INERGEN Clean Agent Fire Suppression System

Section 1.3: PRESSURE VESSEL COMPONENTS AND SYSTEMS AND COMPRESSED GAS CYLINDERS

Transcription:

Explosion Isolation. No matter what happens - nothing happens. / Ventex ESI-E/-D, ESI-C, ESI-P RICO Slide Valve RSV-D, RSV-G, RSV-P REDEX Flap REDEX Slide

Confidence through safety: rico Sicherheitstechnik AG. / Constantly enhancing your safety this has been the objective of RICO Sicherheitstechnik AG since 1988. The components we have developed provide effective protection against the spread of explosions in industrial systems and our butterfly valves close off ventilation ducts, providing a 100 % gastight seal. By applying the highest standards in terms of quality and functionality of our technology, we develop products you can trust. Swiss quality in worldwide use. As a global company with Swiss roots, we support well-known businesses in a variety of industrial sectors worldwide, providing expertise, service and top-class products. In the explosion protection market we have a worldwide network of system providers at our disposal, specialised in optimum operational protection concepts. With support from agents and commercial partners we market our 100% gastight butterfly valves in various countries throughout the world. Every employee is a specialist. We meet ambitious targets with optimum performance: RICO employs an experienced and motivated team of engineers, administrators, CNC operators, fitters and certified welding experts. With this pooled expertise, we work continuously to enhance the high quality and innovation of our products. Experience engenders trust. Our many years of experience mean that we are familiar with the needs of our customers in a wide variety of industries and can respond flexibly to their wishes. We help companies to choose the right components and develop tailor-made special executions. Consistent quality management. RICO Sicherheitstechnik AG is certified according to EN ISO 9001 and ATEX directive 94/9/EC respectively since 2014 according to 2014/34/ EU. In the explosion protection sector we see it as a natural requirement that an ATEX CEtype ex amination is carried out for every single execution. 2 rico

The RICO quality promise. Take our word for it. / Quality cannot be taken for granted. Our quality guarantee. It is the result of focused work and careful control. At Rico, we are very conscientious about this. After all, our products are used where it really matters. And to make sure nothing happens when something happens, we are especially meticulous in our development, certification, production and testing. During development, we make sure our solutions are not designed according to cost aspects but in line with safety criteria. Only the best materials are used in production. When it comes to certification, we only have our products certified where testing is especially rigorous. And our quality assurance calls for the very best quality from our partners. Whether you contact us or one of our partners, we always want you to receive the best possible service. This is the reason why we work with our partners for several years and make sure that they get to know our products as well as we do. We provide information about our products, innovations or changing principles and requirements in training seminars that are held on a regular basis. The Service App developed by RICO offers you further assistance. It helps you to document and manage service intervals and maintenance work. This helps to ensure the functionality of RICO products throughout their lifetime. With certified quality of RICO, we make sure that our customers are safer. certified Quality rico 3

/ / The choice is yours, so make the most of our options. / If the preventative protection measures are insufficient to reliably prevent an explosion, design measures have to be worked out. Apart from some defined exceptions, this calls for the use of explosion isolation components to protect persons and systems against damage or injury irre spective of whether the system is explosion pressure resistant designed, suppression devices are used or relief components have been defined at the vessel. Explosion pressure resistant design. In order to protect the vessel or apparatus against the effects of pressure from an explosion, it is possible to use an explosion pressure resistant design for the maximum explosion pressure. The explosion is consciously taken into account. Explosion suppression. Sensors detect an explosion in the system within few milliseconds. They send a signal to the control unit, which opens pressurized containers and allows extinguishing agent to be sprayed. This stops an explosion right at the start. Explosion pressure relief. The pressure of an explosion is directed out of the system via relief components (with or without flames), for example rupture disks. The so called reduced explosion pressure is smaller than the maximum explosion pressure. Explosion pressure relief prevents the build-up of an unacceptably high explosion pressure in the vessel and apparatus. Irrespective of what explosion protection design measures concept is applied, the explosion must also be isolated. If an isolation is omitted, the ex plosion can spread to other system parts via the connected pipes. A potential consequence would be a flame jet ignition in a neighbouring vessels owing to pre compression effects and increased turbulences. But with an explosive pressure that can be many times higher than the value determined in the laboratory for the medium used. 4 rico

Find the right solution quickly. / VENTEX ESI REDEX Flap RICO Slide Valve RSV VENTEX ESI-P REDEX Slide Value passive component active component, additional detection and control unit necessary Pressure > 10 bar < 10 bar ~ 1 bar Dust load > 50 g/m 3 < 50 g/m 3 Medium metallic dusts hybrid mixtures gases organic dusts Pressure drop no Flow velocity > 35 m/s < 35 m/s Process temperature > 250 C > 100 C < 100 C Mode of operation double acting single acting Installation position any vertical horizontal rico 5

VENTEX ESI-E/-D Type 6. All-round protection. / Functional diagram VENTEX ESI-E/-D Passive protection against explosions. In the versions ESI-E «single acting» and ESI-D «double acting», VENTEX Type 6 is suitable for explosion protection in one or both directions of flow without external energy. When idle or rather without air flow, the closing device is held in the middle position. In normal operation, the medium flows around the closing device. Versions Sizes DN100 to DN600 E: single acting without external energy / passive D: double acting without external energy / passive In case of an explosion, the pressure wave pushes the closing device against the closing device seal. The valve is locked in this closed state, preventing the spread of flames and pressure waves. 6 rico

VENTEX ESI-C Type 6. Just open when the time is right. / Functional diagram VENTEX ESI-C The passive explosion isolation valve VENTEX ESI-C Type 6 is a check valve. Its special mode of operation makes it suitable for explosion protection against the flow direction. When idle or rather without air flow, the closing device is held in the closed, but not locked, position by a return spring. In normal operation, the air flow keeps the valve open. Versions Sizes DN100 to DN600 C: check valve without external energy / passive In case of an explosion, the pressure wave pushes the closing device back to the closed position. The valve is now locked, preventing the spread of flames and pressure waves. VENTEX ESI-C is thus suitable for explosion isolation against flow direction. rico 7

Ventex ESI-P. Fast protection in limited space. / Functional diagram VENTEX ESI-P The active explosion protection valve VENTEX ESI-P is operated with external energy and also enables effective protection against fires thanks to its special mode of operation. Versions / / Sizes DN100 to DN500 / / P: single acting with external energy / active The system to be protected is equipped with pressure and /or flame sensors. In normal operation, the medium flows around the closing device, the valve can easily be opened and closed pneumatically. The control issues a signal that activates one or more gas generators. The pressure generated moves the closing device in only a few milliseconds for sealing and closes the valve. 8 rico

RICO Slide Valve RSV. Always the right match to close! / Functional diagram RICO Slide Valve RSV Do you require a free pipe without pressure drop and the shortest installation distances? The rico Slide Valve RSV enables safe explosion protection in the pipe system. Available in different versions, it is suitable both for use in pharmaceutical media as well as for systems processing dust and gas. RSV-D The rico Slide Valve RSV-D protects systems conveying dust against explosion propagation. RSV-D ensures protection on both sides. RSV-G The double acting rico Slide Valve RSV-G is an explosion protection in gas version. RSV-P The double acting RICO Slide Valve RSV-P is especially suitable for pharmaceutical applications. Its special pharmaceutical-grade housing allows for optimum cleaning at the point of contact with the product, both inside and outside. Versions Sizes DN50 to DN400 Further sizes as special execution D: dust, double acting G: gas, double acting P: pharmaceuticals, double acting The protected system is fitted with pressure and/or flame sensors. These detect an explosion and transmit a signal. Depending on the size of the slide valve, the signal activates one or more gas generators, which close the slide valve through the generated pressure. The spread of flames and pressure waves is therefore effectively prevented. The extremely fast closing time also enables very short in stallation distances. In normal operation, the slide valve can be opened and closed pneumatically. rico 9

REDEX Flap. Safely locked. / Functional diagram Redex Flap The passive explosion isolation flap valve enables optimal protection thanks to a mechanical locking device. The REDEX Flap complies with the standard EN 16447. The flap valve is single acting and prevents the propagation of explosions opposite the flow direction. Without air flow, the flap valve is closed, but not locked. In this position the functional safety is monitored via a switch. Versions Sizes DN140 to DN400 for organic dusts single acting for pull applications minimum pressure drop In normal operation, the flap valve is in the open position, allowing the medium to flow around it. In case of an explosion, the pressure wave pushes the flap valve into the closed and locked position. This prevents the spread of flames and pressure waves. A switch monitors the function. 10 rico

REDEX Slide. Single pressure double action. / Functional diagram REDEX Slide Do you need to protect a process with a high dust load and low explosion pressure? The explosion isolation slide valve, REDEX Slide, is the perfect solution thanks to its simple technical structure accompanied by attractive prices and low maintenance costs. Versions Sizes DN80 to DN150 for organic dusts double acting The protected system is fitted with pressure and/or flame sensors. These detect an explosion and transmit a signal. The signal activates a gas generator, which closes the slide valve through the generated pressure. The spread of flames and pressure waves is therefore effectively prevented. The extremely fast closing time enables very short installation distances. In normal operation, the slide valve can be opened and closed pneumatically. rico 11

GD0362GB_c You can find our sales partners at www.rico.ch/en/partner-representatives Rico Sicherheitstechnik AG St. Gallerstrasse 26 CH-9100 Herisau / Switzerland T +41 (0)71 351 10 51 F +41 (0)71 351 10 52 info@rico.ch / www.rico.ch