FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG

Similar documents
4/2 way Pneumatic Solenoid Valve

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

SPCH/ Blowing block

Solenoid valves VZWF, force pilot operated

SOLENOID VALVES AND PNEUMATIC VALVES

Nugget 120 V14 Series

VALVES ISO 5599/1, SERIES IPV-ISV

Nugget 120 V14 Series

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

3-Way Safety Block DSV

Pneumatic pressure switch 20DD

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Spool compact valves pilot and solenoid actuated G 1/8 - G 1/4

Solenoid Valves VUVG Overview

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

VSD03M DIRECTIONAL CONTROL VALVES

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

Tightness controls TC 1 3 and TC 4

Pilot valves for pilot operated servo valves

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

II 2G EEx ia IIC T6. Ignition protection class

Tightness control TC. Product brochure GB 3 Edition AGA

Directional Control Valves Series VA13 and VA15 3- and 5-port valves, G1/8

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

2/2-Way Solenoid Control Valve

Pneumatic Gripping Modules. Pneumatic 2-Finger Radial Grippers

Gas Pressure Regulator HON 200

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

Pneumatic Grippers Swivel Modules

MATERIALS SPARE PARTS. iting pressure (b. Spool compact valves series MEK

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

PWG-S. Application example. Pneumatic 2-Finger Angular Gripper Universal Gripper. Sizes. Gripping moment 5.98 Nm Nm. Weight 0.21 kg 1.

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Proportional pressure regulators VPPE

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

Fast Switching Valves

PFH. Application example. Pneumatic 2-Finger Parallel Grippers Long-stroke Grippers. Sizes Gripping force 510 N N

PSH. Application example. Pneumatic 2-Finger Parallel Gripper Long-stroke Gripper. Stroke per finger 14 mm.. 64 mm. Sizes

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

PGN. Application example. Pneumatic 2-Finger Parallel Grippers Universal Grippers. Gripping force 100 N N. Sizes

Available models Devices Color White sealing bellows Black sealing bellows NDT SW NDT GB NDT RT NDT GN NDT WS NDT BL NDT GR

PSH (inch version) Application example. Pneumatic 2-Finger Parallel Grippers Long-stroke Grippers. Stroke per finger 14 mm.. 64 mm. Sizes 22..

Series 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

GWB Pneumatic 2-Finger Radial Gripper Universal Gripper Sizes Weight Gripping moment Opening angle per finger Workpiece weight

Product Information. Gripper for small components MPG-plus 16

Pneumatic valve islands

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

GM-7000 Series CE Approved Gas Control Valve

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Compact pressure switches for gas and air

MPG-plus. Application example. Pneumatic 2-Finger Parallel Gripper Gripper for small components. Gripping force 38 N 175 N. Sizes

SDM to 8 sections monoblock valve D1WWDA02A

PFH. Application example. Pneumatic 2-Finger Parallel Gripper Long-stroke Gripper. Weight 2.65 kg 12.6 kg. Gripping force 630 N 2950 N

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Gas Pressure Switch for DMV safety shutoff valves

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

SPG. Application example. Pneumatic 2-Finger Parallel Gripper Heavy-load Gripper. Weight 35 kg. Stroke per finger 100 mm.

PZN-plus. Application example. Pneumatic 3-Finger Centric Gripper Universal Gripper. Sizes Gripping force 580 N..

Pressure regulators Manually operated Fine setting valves. Brochure

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

Gas Pressure Switch for DMV safety shutoff valves

Safety and Shut-off Block SAF/DSV

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Diaphragm Valve, Metal

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV

filtered air without lubricant. If lubricated air is used, it is recommended to use ISOVG32 oil and to never interrupt lubrication.

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Valves ISO 5599/1 ISO 1, 5/2-5/3, electrically operated, with CNOMO pilot

Two-port seat valves

Solenoid valve type EVR for Hydrocarbons

TECHNICAL CHARACTERSTICS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

D62 - D63 Directional Control Valve l/min

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

seriesek Spool valves pilot and solenoid actuated G 1/8 - G 1/4 - G 1/2 DESCRIPTION Spool valves series EK 2.43 MATERIALS TECHNICAL DATA SPARE PARTS

Hand slide valves W/VBOH

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

W60 Spool & Sleeve Valves for ISO Bases (5599/I)

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Transcription:

PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG TECHNICAL CHARACTERISTICS Number of ways / positions : 3/2, 3/3, 5/2, 5/3, 5/4 Nominal sizes (ND) : 4, 6, 9, 12 Medium : compressed air Actuation type : solenoid actuation (with/ without auxiliary pilot air connection) with manual override as standard pneumatic actuation Return type : solenoid return (with/ without auxiliary pilot air connection) with manual override as standard pneumatic return spring return Voltage (Un) : 12, 24, 48, 110, 220 VDC 24, 110, 220 VAC 50-60 Hz optional Permissible frequency fluctuations : TYPICAL VERSIONS 0.85...1.1 Un or 0.75...1.25 Un Duty cycle : ED=100% Power consumption for U=(0.85...1.1)Un : DC: 4.5 W AC: inrush / hold: 8 / 6 VA Power consumption for U=(0.75...1.25)Un : DC: 6 W AC: inrush / hold: 11 / 8 VA Degree of protection with socket : IP 65, acc DIN 40050 Ambient temperature range : -40 C...+70 C Body material : anodized aluminium Seals material : Perbunan Flow coefficient (Kv), as in table bellow: ND [mm] 4 6 9 12 Kv [m 3 /h] 0,3 0,78 1,6 2,6 PACKET OF VALVES SINGLE VALVE FOR PACKET A135-1/1-99

Solenoid return Pneumatic return Pneumatic actuation Pneumatic return VPP 5/2 (B) 2 4 (A) (Y) 14 12 (Z) (S) 3 1 5 (R) (P) A135-1/2-99

Spring return Pneumatic actuation Spring return OVERALL AND MOUNTING DIMENSIONS FOR VALVES PACKET Dn Lmax lp G Gp H Hp1 Hp2 Hp3 Hp4 Hpf Hpm Hpsi 4 6 206 75 G1/4" G1/2" 26 30 18 4 4 14 14 4 9 12 248 79 G1/2" G3/4" 34 36 28 4 4 14 14 4 A135-1/3-99

OVERALL AND MOUNTING DIMENSIONS FOR SINGLE VALVE Solenoid return VPG 3/2. XX. 1. 1. 1. X. X. 3-10 - VPG 3/2. XX. 8. 8. 1. X. X. 0-10 3-10 VPG 3/3. XX. 1. 1. 1. X. X. 3-10 - VPG 3/3. XX. 8. 8. 1. X. X. 0-10 3-10 VPG 5/2. XX. 1. 1. 0. X. X. 2-10 - VPG 5/2. XX. 8. 8. 0. X. X. 0-10 2-10 VPG 5/3. XX. 1. 1. 3. X. X. 2-10 - VPG 5/3. XX. 1. 1. 4. X. X. 2-10 - VPG 5/3. XX. 1. 1. 5. X. X. 2-10 - VPG 5/3. XX. 8. 8. 3. X. X. 0-10 2-10 VPG 5/3. XX. 8. 8. 4. X. X. 0-10 2-10 VPG 5/3. XX. 8. 8. 5. X. X. 0-10 2-10 VPG 5/4. XX. 1. 1. 6. X. X. 2-10 - VPG 5/4. XX. 1. 1. 6. X. X. 2-10 - VPG 5/4. XX. 8. 8. 7. X. X. 0-10 2-10 VPG 5/4. XX. 8. 8. 7. X. X. 0-10 2-10 Pneumatic return VPG 3/2. XX. 1. 2. 1. X. X. 3-10 2-10 VPG 3/2. XX. 8. 2. 1. X. X. 0-10 2-10 VPG 3/3. XX. 1. 2. 1. X. X. 3-10 3-10 VPG 3/3. XX. 8. 2. 1. X. X. 0-10 3-10 VPG 5/2. XX. 1. 2. 0. X. X. 2-10 2-10 VPG 5/2. XX. 8. 2. 0. X. X. 0-10 2-10 VPP ISO 5/3. XX. 1. 2. 3. X. X. 2-10 2-10 VPP ISO 5/3. XX. 1. 2. 4. X. X. 2-10 2-10 VPP ISO 5/3. XX. 1. 2. 5. X. X. 2-10 2-10 VPP ISO 5/3. XX. 8. 2. 3. X. X. 0-10 2-10 VPP ISO 5/3. XX. 8. 2. 4. X. X. 0-10 2-10 VPP ISO 5/3. XX. 8. 2. 5. X. X. 0-10 2-10 VPP ISO 5/4. XX. 1. 2. 6. X. X. 2-10 2-10 VPP ISO 5/4. XX. 1. 2. 6. X. X. 2-10 2-10 VPP ISO 5/4. XX. 8. 2. 7. X. X. 0-10 2-10 VPP ISO 5/4. XX. 8. 2. 7. X. X. 0-10 2-10 Spring return VPG 3/2. XX. 1. 3. 1. X. X. 3-10 - VPG 3/2. XX. 1. 3. 2. X. X. 3-10 - VPG 3/2. XX. 8. 3. 1. X. X. 0-10 3-10 VPG 3/2. XX. 8. 3. 2. X. X. 0-10 3-10 VPG 5/2. XX. 1. 3. 0. X. X. 2-10 - VPG 5/2. XX. 8. 3. 0. X. X. 0-10 2-10 Dn L1 L2 L3 lp H A B C 4 6 206 159 151,5 75 26 24 48 38 9 12 248 198 186,5 79 34 32 64 48 4 2 4 2 4 2 A135-1/4-99

Pneumatic actuation Pneumatic return VPG 3/2. XX. 2. 2. 1. 0. 0. 0-10 3-10 VPG 3/3. XX. 2. 2. 0. 0. 0. 0-10 3-10 VPG 5/2. XX. 2. 2. 0. 0. 0. 0-10 2-10 VPG 5/3. XX. 2. 2. 3. 0. 0. 0-10 2-10 VPG 5/3. XX. 2. 2. 4. 0. 0. 0-10 2-10 VPG 5/3. XX. 2. 2. 5. 0. 0. 0-10 2-10 4 2 Pneumatic actuation Spring return VPG 3/2. XX. 2. 3. 1. 0. 0. 0-10 3-10 VPG 3/2. XX. 2. 3. 2. 0. 0. 0-10 3-10 VPG 5/2. XX. 2. 3. 0. 0. 0. 0-10 2-10 4 2 Dn L4 L5 H l A B C 4 6 112 104,5 26 50 24 48 38 9 12 148 136,5 34 64 32 64 48 LEGEND : 1 (P) - Supply port 4, 2 (B, A) - Working or outlet lines 5, 3 (R, S) - Exhausts 14, 12 (Pz) - Auxiliary pilot air 14, 12 (Y, Z) - Pilot lines NOTE: connection 4 is missing for VPP 3/2, VPP 3/3 A135-1/5-99

OVERALL AND MOUNTING DIMENSIONS FOR ACCESSORIES Common supply - exhaust plate coded (P1) Single exhaust plate coded (P2) Exhaust separation plate codec (P3) Blanking plate (P4) Dn Lp l Hp1 Hp2 Hp3 Hp4 Gp G A B C 4 6 82 50 30 18 4 4 G1/2" G1/4" 24 48 52 9 12 108 64 36 28 4 4 G3/4" G1/2" 32 64 68 A135-1/6-99

CODING FOR VALVES PACKET ( HOW TO ORDER ) VPG Coding Level XX. X. XX. ( ) a b c d Coding level denomination a) Nominal size of valves (ND) 06 4 and 6 12 9 and 12 b) Holder length (Ls) / band - pass (dg) / Holes diameter( ) see figure 1 300 / 270 / 8.5 (for at most 5 valves noted with 06. at level a) 2 500 / 470 / 8.5 (for at most 10 valves noted with 06. or 5 valves noted with 12 at level a) 3 800 / 750 / 10.5 (for at most 16 valves noted with 06. or 10 valves noted with 12 at level a) 4 1000 / 950 / 10.5 (for at most 16 valves noted with 12 at level a) c) Number of components on holder specify the number of valves and number of plates d) Packet pattern specify consecutively (begin from left side of holder) every valve and every plate; select valves according the example bellow ; plates coding is as fallows : P1 common supply-exhaust plate P2 single exhaust plate P3 exhausts separation plate P4 blanking plate EXAMPLE OF CODING FOR ONE PACKET VALVES (HOW TO ORDER) Example of coding for one packet valves VPG 06. 2. 14. ( ) 1 P1 2 VPG 5/2. 06. 1. 1. 0. 2. 0. 3 VPG 5/2. 06. 1. 3. 0. 2. 0. 4 VPG 5/2. 06. 2. 2. 0. 0. 0. 5 P3 6 VPG 5/2. 04. 2. 2. 0. 0. 0. 7 P2 8 VPG 5/2. 04. 2. 2. 0. 0. 0. 9 P2 10 P1 11 VPG 3/2. 06. 2. 2. 1. 0. 0. 12 VPG 3/2. 04. 1. 3. 2. 2. 0. 13 VPG 3/2. 06. 1. 3. 1. 2. 0. 14 P1 Nominal size of valves ND 4 and ND 6 Holder lenght / band-pass / Φ (Ls / dg / Φ) 500 / 470/ 8.5 number of components on holder 14 Packet Pattern VPG 06. 2 14 specify consecutively every valve and every plate A135-1/7-99

CODING FOR SINGLE VALVES (HOW TO ORDER) VPG Coding Level XX. XX. X. X. 0. X. X. a b c d e f g Coding level denomination a) Number of ways / positions 3/2 3 ways / 2 positions 3/3 3 ways / 3 positions 5/2 5 ways / 2 positions 5/3 5 ways / 3 positions 5/4 5 ways / 4 positions b) Nominal size 04 4 mm 06 6 mm 09 9 mm 12 12 mm c) Actuation type 1 solenoid actuation (without auxiliary pilot air connection) 2 pneumatic actuation 8 solenoid actuation (with auxiliary pilot air connection) d) Return type 1 solenoid return without auxiliary pilot air connection 2 pneumatic return 3 spring return - only for 3/2 or 5/2 at level a 8 solenoid return with auxiliary pilot air connection e) Valve state 0 not applicable 1 normal closed (3/2NI) 2 normally open (3/2ND) 3 mid-pozition closed (5/3I) 4 mid-pozition open (5/3D) 5 mid-pozition pressurized (5/3P) 6 closed (5/4I) 7 open (5/4D) f) Voltage 0 c`nd not applicable 1 12 VDC 2 24 VDC 3 48 VDC 4 110 VDC 5 220 VDC 6 24 VAC / 50-60 Hz 7 110 VAC / 50-60 Hz 8 220 VAC / 50-60 Hz 9 optional g) Permissible frequency fluctuations 0 0.85...1.1 Un 1 0.75...1.25 Un NOTE: Versions available as in drawing with overall dimensional. A135-1/8-99