ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

Similar documents
Robert H. Peterson Company

AC POWERED ELECTRONIC PILOT KIT

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

INSTALLATION AND OPERATING INSTRUCTIONS

G45-2 STAINLESS STEEL BURNER FOR INDOOR OR OUTDOOR USE

ROBERT H. PETERSON CO. EPIC BURNER GAS LOG SET

WARNING: FOR OUTDOOR USE ONLY

EPIC BURNER GAS LOG SET

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

ROBERT H. PETERSON CO.

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

OCBE-34-01M (P) OUTDOOR CAMPFYRE ELECTRONIC SYSTEM WITH REMOTE CONTROL

OPERATING INSTRUCTIONS

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

INSTALLATION GUIDE Gas Rangetops

OCBE-44 series ROUND OUTDOOR CAMPFYRE CONTROL SYSTEM

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

INSTALLATION AND OPERATION INSTRUCTIONS

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

Installation and Operation Instructions

JACKSON GRILLS PATIO FIRE

Standard Gas Countertop Griddle

Natural Gas Conversion Kit

GAS FRYER Instruction Manual Model #5099NS

Gas Fired Residential Heating Boilers

USER S INFORMATION MANUAL

INSTRUCTION MANUAL. Gas Salamander

Gas Countertop Hot Plates

OWNER'S MANUAL WARNING WARNING WARNING WARNING. Factory No.: HYFP Item No.: 67668ST

Operator: Save these instructions for future use!

ACCESSORY KIT INSTALLATION INSTRUCTIONS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

CASUAL FIRESIDE A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR FIRE PIT FOR PROPANE AND *NATURAL GAS

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Robert H. Peterson Co.

installation instructions

Vianti Falls Fire Burner Kit (HBF16) & Propane Adapter Kit (HBF16AK) (These instructions are intended for use with a 20 lb.

ACCESSORY KIT INSTALLATION MANUAL


G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G92 Series BASOTROL Automatic Pilot Gas Valve

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

ASSEMBLY & OPERATING INSTRUCTIONS

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

ACCESSORY KIT INSTALLATION INSTRUCTIONS

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

Gas Countertop Griddle

INSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300

G96 Series BASOTROL Dual Operator Valve

TK Torch Match Lit WARNING: FOR OUTDOOR USE ONLY

FPK Spark Ignition Safety Manual Installation & Operation Instructions. This Product is for use with Natural Gas Only.

ASSEMBLY & OPERATING INSTRUCTIONS

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Natural Gas to L.P. Gas Conversion Kit

Operator: Save these instructions for future use!

ACCESSORIES MAY BE PURCHASED SEPARATELY.

GAS CONVERSION KIT Installation Instructions Range/Rangetop

Installation Instructions

Natural Gas to L.P. Gas Conversion Kit

Match Lit Fire Pit Insert MLFPK Series Installation & Operation Instructions

OWNERS MANUAL WARNING WARNING WARNING WARNING WARNING WARNING DANGER. Series No.: Style No.: READ BEFORE USE!

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

Installation Instructions

Thanks for shopping with Improvements! Monterey Propane Fire Column Item #574852

Hearth Products Controls Co. 706 Congress Park Dr. Dayton, OH FPK Spark Ignition Safety Manual Installation & Operation Instructions

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

Congratulations! Hand Held Torch. Warranty Policy PARTS

Toll Free: (877) Fax: (877) TK Torch Match Lit WARNING: FOR OUTDOOR USE ONLY

36H SERIES Combination Gas Valve

Operator: Save these instructions for future use!

OWNER S MANUAL 28" GRIDDLE COOKING STATION

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

FPLP CONVERSION KIT- Small Tank Fire Pit LP Conversion Kit for Manual Ignition Pits

Operator: Save these instructions for future use!

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL. Gas Ranges

Operator Manual Gas Griddle / Cheesemelter

/2004 US/CA

INSTALLATION & OPERATION MANUAL FOR Stockpot Range

GAS BBQ 4 burner. instructions for. model no: BBQ10

- Do not store gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

FIREPLACE INSTALLATION

Match Lit Fire Pit Safety Manual Installation & Operation Instructions

Gas Conversion Kit Pilot Ignition Heaters

Operator: Save these instructions for future use!

Propane Conversion Kit Instructions

MATCH LIT FIRE PIT INSERT

127 / 460 Air Mixer and all FPSLPK Kits Installation & Operation Instructions

PUSH-BUTTON / FLAME SENSING FIRE PIT INSERT

Operator: Save these instructions for future use!

Installation Instructions For Natural Gas Conversion

Fire's Edge. Fire Pit or Fire Pit Insert Model 100A-M (Manual Operation) OWNER S MANUAL / OPERATING AND MAINTENANCE INSTRUCTIONS

Owner s Manual for Assembly, Operating & Maintenance of

APPROVED FOR USE IN SOUTH AFRICA STAINLESS STEEL STOVE

MATCH LIT FIRE PIT MANUAL INSTALLATION & OPERATION INSTRUCTION

Owner's Manual and Instructions

FPLP CONVERSION KIT- Small Tank Fire Pit LP Conversion Kit for Manual Ignition Pits

Transcription:

ROBERT H. PETERSON CO. Owner s Manual AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS FEATURES: CONTROL OPERATED ON/OFF VARIABLE FLAME-HEIGHT REMOTE VARIABLE FLAME HEIGHT CONTROL SUITABLE FOR PAN BURNERS (P-SERIES), G4 SERIES BURNERS, & G45 SERIES BURNERS Installer: Leave this manual with the consumer. Consumer: Retain this manual for future reference. Model APK-17(M)(P) FOR USE WITH PETERSON GAS LOG SETS ONLY WARNING If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: Open a window. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in the building. Immediately call the gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach the gas supplier, call the fi re department. - Installation and service must be performed by a qualified installer, service agency, or the gas supplier. INSTALLER & CONSUMER These instructions MUST be retained with this appliance Important: Read these instructions carefully before starting installation. BE SURE DAMPER IS FULLY OPEN WHEN OPERATING THE LOG SET PETERSON VENTED GAS LOG SETS ARE TO BE OPERATED ONLY IN A FULLY VENTED, NONCOMBUSTIBLE FIREPLACE WITH DAMPER AND CHIMNEY FREE OF ANY OBSTRUCTIONS. THE FIREPLACE MUST BE DESIGNED AND APPROVED TO BURN WOOD. Like burning natural fi rewood, the Peterson log set is designed to burn with a yellow, smoky fl ame. For this reason, it must be adequately vented. Be sure the fi replace damper is fully open when you burn the gas log set. The smallest dimension of the chimney fl ue must be at least 8". If it is smaller, DO NOT USE A PETERSON LOG SET. If fumes from the burner emerge into the room when the damper is fully open, creating a smell like a smoldering oil lamp, it indicates that the fi replace draft is defective. Check chimney fl ue for obstructions. DO NOT OPERATE LOGS UNTIL THE FIREPLACE DRAFT IS CORRECTED. Check with your dealer or installer. Do not use fi rewood with this unit. This safety pilot system contains a control certified by C.S.A. Robert H. Peterson Co. 14724 East Proctor Avenue City of Industry, California 91746 1

IMPORTANT INFORMATION The installation, including provisions for combustion and ventilation air, must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition). This appliance and its individual shutoff valve must be disconnected from the gas supply piping system when testing at pressures exceeding 1/2 psig. Do this by closing the gas supply valve. This appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any testing of the gas supply system at test pressures up to and including 1/2 psig. WHEN GLASS FIREPLACE ENCLOSURES (DOORS) ARE USED, OPERATE THE GAS LOG SET WITH THE GLASS DOORS FULLY OPEN; BOTH SIDES IF FIREPLACE IS SEE-THRU TYPE. PARTS LIST 3 6 7 Pilot gas supply line Thermocouple lead 2 10 (If equipped) 5 0FF PILOTON 4 Gas inlet nipple 8 1 Item No. Description 1 Safety pilot valve (natural gas) or Safety pilot valve (propane gas) 2 Heat shield (fi ts over valve) 3 Pilot assembly (natural gas) or Pilot assembly (propane) 4 Knob 2 Item No. Description 5 Knob extension 6 Pilot orifi ce (natural gas) or Pilot orifi ce (propane gas) 7 Mounting Bracket, pilot Assembly 8 Flame diverter 9 VR-1A remote kit (if equipped) Remote kit with remote instructions.

OFF PILOT NO HOW TO HOW ASSEMBLE TO ASSEMBLE YOUR APK-17(M)(P) YOUR SAFETY SAFETY PILOT PILOT KIT SYSTEM This safety pilot kit must be installed by a qualified professional installer. Instructions must be followed carefully during installation to ensure proper performance and achieve full benefit from your gas log set and safety pilot kit. GENERAL - These instructions must be used as a supplement to the instructions supplied with your Peterson gas log set. Follow the gas log set instructions and make adjustments as appropriate for the addition of a safety pilot kit. Use gas pipe sealing compound which is resistant to all gasses or Tefl on tape and apply to all male pipe connections. Make sure that all connections are tight. Caution: Do not cover the safety pilot valve with sand or lava granules, it may cause overheating. FOR L.P. (PROPANE) GAS - The safety pilot kit may require a pilot conversion unless it is a propane model. Replace the natural gas orifi ce with the L.P. gas orifi ce (Item No. 6, PARTS LIST) contained in the envelope marked "L.P.-GAS". Reattach the pilot gas supply line to the pilot. STEP 1 - CONNECTING THE SAFETY VALVE TO THE BURNER A. Remove the heat shield, knob and handle extension. B. Apply gas pipe compound or Tefl on tape to the fuel injector/air mixer pipe threads. Be careful not to block the opening of the fuel injector/air mixer. C. Screw the safety valve (Item No. 1) to the fuel injector or air mixer on the burner (Fig. 3-1). Be sure that the valve is positioned parallel with the fi replace fl oor. STEP 2 - INSTALLING THE FLAME DIVERTER BRACKET Purpose: The fl ame diverter, when properly installed onto Peterson "G4", "GX4", "VG4" and "P" series burner pans equipped with a safety control system, will promote quicker ignition of your Peterson gas log set and increase safety. Note: Heat shield is not shown but must be in place when operating your log set. Fuel injector / Air mixer SPK Valve Fig. 3-1 A. Install the flame diverter before installing the pilot assembly. B. Place the fl ame diverter (Item 8) over the side edge of the burner pan where the Peterson safety control system pilot (Item 7) will be attached. The should be placed approximately 1 1/4" from the back of the burner pan (see Fig. 3-2). C. Tap the lightly with a hammer to secure it in place. Fig. 3-2 a. Pilot assembly b. Pilot assembly Flame diveter Pilot Insulation pad Burner pipe Burner pipe Flame diveter Burner pan 3

HOW TO INSTALL THE APK-17(M)(P) SAFETY PILOT SYSTEM (Cont.) CAUTION: Keep granules and all foreign objects away from pilot burner assembly and valve assembly. CAUTION: Route the pilot supply tube and thermocouple lead as required so that they curve gradually. DO NOT KINK. (Reference Fig. 3-1.) STEP 3: INSTALL THE PILOT ASSEMBLY TO THE BURNER Refer to the PARTS LIST when following these instructions. GLOWING EMBER - G4, GX4, and G45 SERIES FLAME PAN - P SERIES Pilot assembly Pilot assembly Burner pan Flame diverter Insulation pad Mounting Flame diverter Mounting Insulation pad Burner Fig. 4-1 pan Fig. 4-2 A. Carefully bend the thermocouple lead and the pilot gas supply line so the pilot assembly is positioned as illustrated above. B. Place the insulating pad between the and the pan. Insert the screws through the pilot and the holes in the end of the pan. A. Carefully bend the thermocouple lead and the pilot gas supply line so the pilot assembly is positioned at end of the pan as illustrated. B. Place the insulating pad between the and the pan. Insert the screws through the pilot and the holes in the end of pan. STEP 4: HEAT SHIELD PLACEMENT Cover the APK-17(M)(P) safety valve with the heat shield (PARTS LIST item 2) as shown in Fig. 4-3. Do not cover the valve with sand or granules. Heat Shield Note: Place the plastic heat shield over the remote receiver (if equipped) with the open side facing front to allow access to the receiver controls. Fig. 4-3 CONNECT THE REMOTE RECEIVER TO THE APK-17(M)(P) VALVE (WHEN EQUIPPED) A. Discard the wires that come with the remote receiver. Connect the valve wires to the remote receiver as shown in Fig. 4-4. APK-17 valve Insulation Red wire this side Note: It is recommended to place the receiver as far from the gas log set as possible. Fig. 4-4 Black wire this side ADJ. OFF REMOTE ON LEARN Remote receiver 4

APK-17(M)(P) OPERATING INSTRUCTIONS HOW TO LIGHT THE PILOT Push in slightly on the control knob and turn to the 'OFF' position (Fig. 5-1). Then turn the knob to the 'PILOT' position (Fig. 5-2). Push the knob fully in and at the same time place a long lighted match or long necked lighter at the pilot burner. The pilot should light. Hold the knob in approximately 60 seconds. The pilot should stay lit. If the pilot does not stay lit, turn to the full 'OFF' position (Fig. 5-1). Wait fi ve minutes and repeat the lighting instructions. HOW TO TURN YOUR GAS LOG SET ON AND OFF USING YOUR SAFETY PILOT KIT BE SURE THE DAMPER IS FULLY OPEN WHEN OPERATING YOUR GAS LOG SET. TO TURN ON THE GAS LOG SET FROM THE PILOT POSITION when pilot is lit (Fig. 5-2), turn the knob 90 counter clockwise to the 'ON' position (Fig. 5-3). TO TURN OFF THE GAS LOG SET FROM THE ON POSITION (Fig. 5-3), turn the knob 90 clockwise to the 'PILOT' position (Fig. 5-2). TO TURN OFF THE GAS LOG SET AND THE PILOT FROM THE PILOT POSITION (Fig. 5-2), push in slightly on the knob and turn 90 clockwise to the 'OFF' position (Fig. 5-1). For remote lighting; follow the instructions for lighting the pilot above and then follow the instructions that came with your remote. FOR IMPROVED PILOT OPERATION READ HERE READ HERE READ HERE 1. Use "OFF" only when complete shutdown is necessary. Fig. 5-1 OFF POSITION BURNER OFF - PILOT OFF 2. Turn Dial to "PILOT" position. With match ready press knob in and hold for 60 seconds while lighting pilot. Fig. 5-2 PILOT POSITION BURNER OFF - PILOT ON 3. Turn knob to "ON" to light burner. Fig. 5-3 ON POSITION BURNER ON - PILOT ON PILOT ADJUSTMENT - Should the pilot require adjustment, the following steps should be taken: With the pilot lit and the control knob in the pilot position, use a long narrow screw driver and turn the pilot adjustment screw slowly clockwise to reduce the pilot fl ame or counter clockwise to increase the fl ame (Fig. 5-4). The adjustment screw can be turned so that the pilot fl ame is completely extinguished. Some tightening of the screw may occur during adjustment; this is normal. The pilot fl ame should be a soft blue color with slightly yellow tipping which encircles the thermocouple tip. After adjustment turn the control knob to the 'ON' position to assure proper ignition of the log burner. Pilot adjust Fig. 5-4 Example of burner pilot flame Fig. 5-5 5

NOTES PAGE Please use this page to record any information that you may want to have at hand. 6

TROUBLESHOOTING THE APK-17(M)(P) SAFETY PILOT KIT PROBLEM CAUSE SOLUTION 1. Pilot will not light. a. Obstruction in pilot gas supply/ pilot gas supply line is kinked. b. Inadequate gas supply. c. Air in line. 2. Pilot will not stay lit after releasing knob. 3. Log set extinguishes a few minutes after lighting. 4. Log set extinguishes after burning for some time (approximately 10 minutes to 1 hour). a. Thermocouple connection to valve either too tight or too loose. b. Bad thermocouple. a. Inadequate gas supply causes pilot fl ame to reduce after burner lights. a. Thermocouple has overheated; glass doors are closed. b. Thermocouple has overheated; insulation pad is not in place. c. Thermocouple has overheated; burner fl ames are heating the thermocouple cold junction. a. Clear out obstruction. Replace pilot gas supply line if kinked. b. Have gas pressure checked by installer or gas supplier. c. Air should clear, attempt to relight. a. Thermocouple should be fi nger tight and then 1/8" turn with a wrench. b. Replace thermocouple. a. Using pilot adjustment, increase gas to pilot. Pilot fl ame must be in contact with the thermocouple tip. a. Be sure glass doors are open during operation. b. Be sure that the insulation pad is in place between the burner pan and the pilot. c. Be sure the pilot assembly and the flame diverter are in their proper position. Rearrange logs so that flame is not defl ected to the thermocouple. 7

WARRANTY PETERSON VENTED GAS LOG SETS LIMITED WARRANTY All Peterson gas logs are WARRANTED for as long as you own them (lifetime). All Peterson burner assemblies are WARRANTED for TEN (10) YEARS. SPK-26 controls are covered by a THREE (3) YEAR All Parts Warranty. All other Peterson valves, pilots, and controls are covered by a ONE (1) YEAR Limited Warranty (excluding batteries). PLEASE KEEP A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASE This warranty applies to the original purchaser and to single family residential use only. It commences from date of purchase, and is valid only with proof of purchase. This warranty does not cover parts becoming defective through misuse, accidental damage, electrical damage, improper handling, storage, and/or installation. Product must be installed (and gas must be connected) as specifi ed in the instructions or operator s manual, by a qualified professional installer. Accessories, parts, valves, remotes, etc., when used must be Peterson Co. product. This warranty does not apply to rust, corrosion, oxidation, or discoloration, unless the affected component becomes inoperable. It does not cover labor or labor-related charges. This warranty specifi cally excludes liability for indirect, incidental, or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specifi ed legal rights, and you may have other rights that may vary from state to state. For additional information regarding this warranty, or to place a warranty claim, contact the R.H. Peterson dealer where the product was purchased. ROBERT H. PETERSON CO. Quality Check Date: Orifice # (Main): Orifice # (Other): Model #: Leak Test: Serial #: Burn Test: Air Shutter: Gas Type: NAT. / PROPANE Inspector: Robert H. Peterson Co. 14724 East Proctor Avenue City of Industry, CA 91746 8