RobLight FL 1500 B-2. User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn. Phone:

Similar documents
Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

Operating Instructions Part No

SILENTAIRE TECHNOLOGY

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

SILENTAIRE TECHNOLOGY

UsER manual for Watersens ph -REDOX

INSTRUCTION MANUAL Pressure Relief Device LPT

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Operating Instructions Part No

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

SPECIFICATIONS ATTENTION

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

INSTALLATION GUIDE Gas Rangetops

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

User Manual V14.1 IP68 LED FLEX NEON

RPS900W Redundant Power Supply. Installation Guide.

A17W23_MASE_MUS_EN MANUAL

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Flow and check valves Logic valves series 551. Brochure

Automatic extractor outlet

MoveRoll Conveyor Operating and Maintenance Manual

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54)

A18W35_MASE 130_F_EN MANUAL

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Pressure switches for air and water CS

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Operating Instructions

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.

VR46.5V(A)/VR86.5V(A) SERIES

Inverse Proportional Pressure-Relief Cart., Size 2 4

High Pressure Breathing Air Compressors

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3M Telecommunications Solutions for Networks. Quante QSA (= LSA plus) System Catalogue. Innovation

Technical Data Sheet TI-F50 Locking Units series KFH

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Columbus Instruments

A17W49_MASEM_F_EN MANUAL

User Instruction Manual

Residential Road_Lighting Class S5

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam MED96/98/EC

Technical Information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

444C DUAL PERFORMANCE VALUE PACK

Installation and Operation Manual

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Infrared Linescanners

VERTICAL AIR COMPRESSORS

Portable oxygen concentrator

AutoChanger Installation & User Guide Issue 2

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

Electropneumatic Transducer (I/P) Installation, Operation and

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

USER S INFORMATION MANUAL

Proportional Pressure-Relief Cartridge Valve, Size 2...4

INSTRUCTION MANUAL. Gas Salamander

TECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC

Air preparation units

DK48 - DK800. Quick Start. Variable area flowmeter

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

Sensoric 4-20 ma Transmitter Board Operation Manual

Instruction and Maintenance Manual

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Instruction Manual EMA 84 Digital Pressure Gauge

Transmitter CS 21 Operation Manual

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Pneumatic spool valve islands

TECHNICAL INFORMATION

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Technical information

Regalia Oxygen Concentrator

Installation Instructions

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Inverse Proportional Pressure-Relief Cart., Size 2 4

TECHNICAL DESCRIPTION

cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

VERTICAL AIR COMPRESSORS

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Introduction. Description. Series P48 Pressure Controls for Steam, Air or (hot) Water. Feature and Benefits

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

400C & 450C DUAL PERFORMANCE VALUE PACKS

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

JET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE

OPERATION MANUAL NTF-15

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

Transcription:

98082129 22-08-2018 Rev. 2.6 User manual FL 1500 B-2 A/S Nordhavnsvej 1A DK - 9900 Frederikshavn Applies to: + 0130 0058 FL 1500 B-2 3000K CRI 90+ + 0130 0068 FL 1500 B-2 4000K CRI 90+ + 0130 0658 FL 1500 B-2 3000K CRI 90+ DALI + 0130 0668 FL 1500 B-2 4000K CRI 90+ DALI + 0130 0758 FL 1500 B-2 3000K CRI 90+ 1-10V + 0130 0768 FL 1500 B-2 4000K CRI 90+ 1-10V Phone: +45 9244 4888 E-mail: info@rob-light.com

Page 2 Page 15 Table of Contents Troubleshooting Warnings... 3 Introduction... 4 Technical data... 5 Attachment of harness... 6 Mounting... 7 9 Accessories... 10 Application notes... 12 Troubleshooting... 15 Problem Trace the problem Solution No light Light switches on and off Check the power Check the temperature. Check the dimming Check the operating conditions of the light generator Check active cooling system. Connect the power cord properly/ Turn on the device Check it is installed according to the instructions. Unplug. Unplug the dimmer system from the driver. Turn on the power. Check it is installed according to the instructions. Remove dirt and dust from light generator. Light output has diminished Check if the light has been dimmed via a dimmer? Check the operating conditions of the light engine Increase brightness to the normal level. If the light engine has been running at elevated temperatures for an extended time, a permanent decrease in the output will be observed FOLLOW THE INSTALLATION INSTRUCTIONS TO ENSURE Safe operation Full functionality Stated expected lifetime Uninterrupted illumination If problems is not solved using this guide please contact Roblight A/S Phone: +45 9244 4888 E-mail: info@rob-light.com

Page 14 Page 3 Accessories / Spare part Warnings Part name Description Ordrering Adapter Ø28/Ø9 If you want to change the light port from Ø28 to Ø9 mm. +7800 0130 This device has a built in high power phosphor converted blue led. The light source is grouped in Risk Group 2. Fan replacement Kit Repair kit with parts to install new fan. (You need to have hand tools) +01308000 Mounting kit Mounting plate to mount light generator on plane surface. +01309000 1-10V dimmer potentiometer 01300758, 01300768 Do not look into the light port when lit. Be aware that placing highly light absorbing material directly in front of (Distance 0-1cm) of the port or a fiber. The extremely high intensity will increase the temperature in the material. Using non harnesses in this light generator is at own risk. Insure that the poly connector is undamaged and clean before using the light generator in retrofit Roblon installations. Be aware that when light generator is operated at max ambient temperature the surface temperature can exceed 75 C. The light generator is only tested with standard polyconnector end. Need to order or get more information. Phone: +45 9244 4888 E-mail: info@rob-light.com If you have any questions regarding the safety of this device. please contact A/S

Page 4 Page 13 Introduction Maintenance, spare parts & repairs The FL1500 light generator is designed for use indoor/dry location with glass and PMMA fibre harness Ø28 mm. It can be used in all installations set-ups, including closed compartments if limits for max ambient temperature are followed. FL 1500 is designed as replacement for FL 150-series. Product overview/unboxing 1 FL 1500 light generator 2 User manual Allen key Power cord The effectiveness of active cooling device in greatly diminished if the cooling fins and the air intake is blocked or polluted with dust. This will reduce the expected lifetime of the product. The dust need to be removed routinely. Interval depending on the environment. A fine brush, vacuum cleaning or light compressed air can be used for the cleaning. This light source is not supposed to be otherwise serviced, if it is used as recommended. The fan can be exchanged using standard tools. A replacement kit with guide is available (page 13). If the product isn t performing as specified, use the troubleshooting guide. If you need further assistance please contact. The warranty label should not be broken under ANY circumstances. If broken the warranty is terminated.! WARNING! Remove red cap before turning on!

Page 12 Page 5 Application notes Technical data The light generator is an electronic device so it will not work forever. The different components will have different factors influencing the practical lifetime. The most important factor for this system is the condition of the surrounding air (temperature and cleanliness). The data we have stated the expected lifetime of the key components are at the temperatures the suppliers has performed their standardized tests and in clean environments. The light generator is designed to run at max ambient, but the longest usable operation is achied lower temperatures. Although there is thermal protection built into this device; it is only a safety device and should not be used as a measurement device to test if the light generator is running at a tolerable surrounding temperature. The poly connector is the most stressed part in this system. Care should be taken to insure that the fibre ends are 100% clean and free from dust and grease (fingerprint will do damage.). See www.rob-light.com for recommendation to clean fibre end. Running the light generator at too high temperature will not only risk damage to the light source but also the fibre harness. General Light port Fibre type Material Dimensions (L x H x W) Dist. between driver and LG Weight (total) Safety Environmental Ø28 mm PMMA or Glass Aluminium 232 x 93 x 158 mm 150 mm 5103 g Protection rating IP 20 Thermal protection Cooling CE, RoHS, WEEE Yes, automatic resettable. Light source cut off Axial fan Ambient temperature -10 C to 45 C KEEP COOL CLEAN AIR Driver/electrical Driver LED driver constant current Driver size (L x H x W) 225 x 40 x 68 Supply voltage (mains) 100 240V 50/60 Hz Driver expected lifetime 100,000 h (@Ta = 70 C) Dimmer systems applicable DALI and 1-10V, others on special req. Total power consumption 115 W Fan expected lifetime 40.000 h@60 C (L90) Fan sound level 30 db Light source Applied LED Nichia LED expected lifetime >35.000 hours @ T a = 45 C Typical CCT 3000 K or 4000 K, 3 SDMC Typical Ra (CRI 1-8 ) 92 (min. 90)

Page 6 Page 11 Attachment of harness Colour Filter (01261004, 01261005, 01261007, 01261007) a) Remove cap from the light port b) Check that the end face of the poly connector is clean or undamaged c) Insert the poly connector fully in the light port d) Tighten the screw onto the light port with an allen key e) Ensure all installation and ventilation requirements are met (see page 7 & 8) f) Connect the supply cord to the mains. WARNING! Remove cap before turning on. Surface mounting Attach to surface using three screws (not supplied) in the baseplate holes. Be aware that the total weight of this system is more than 5 kg + the downforce from the poly connector.

Page 10 Page 7 Installing accessories Vertical mounting 1-10V dimmer potentiometer (01300758, 01300768) This light generator should not be mounted with light port up wards. At high ambient temperature the operational lifetime of the internal components and harness will be reduced. Controlling/measuring the temperature Always unplug, before working with the driver Ambient temperature: Measured 50 mm from the light generator (placed on a vertical plane) at the same height as the center of the light generator, and at the inlet not above 45 C. (p2) All temperatures to be measured when the installation has been running for at least 2 hours continuously. (Temperature will not decrease during the 2 hours if ambient environment is constant). (p1)

Page 8 Page 9 Closed compartments Installing adjacent light generators MAX AMBIENT TEMPERATURE 45 C. Recommendations: (should always be tested in a mock up) Enough space to allow natural heat transmission through surfaces. Surfaces should not be insulated. Cooling air for the poly connector can not be obstructed in any way, as it is essential to avoid damage to the harness. General minimum distance from light generator to any enclosing surface 10 cm (excluded mounting surface) - see drawing for details. Air volume per light generator minimum 0.35 m³ (For insulated surfaces the volume has to be increased) Airflow recommendation. Should be from obstacles inlet/outlet min 30 cm. Recommendation: Minimum 15 cm distance between adjacent light generators to ensure enough free cooling air. If multiple rows. Use offset to avoid vertical rows. Minimal free distance between rows 100 cm. T max has to be observed for all light generators. Measured at air inlet for each light generator. MAX AMBIENT TEMPERATURE 45 C. Recommendation: For compartments smaller than 0.35 m³ Ventilation holes per light generator with min. 100 cm² air inlet and min. 120 cm² air outlet. The observed limits are based on measurements for a wooden box (Ta=+22 C) Airflow