M18W49_MME100_MUS_EN MANUAL

Similar documents
M18W49_MME100EX_F_EN MANUAL

M18W49_MME75_F_EN MANUAL

MANUAL. Verkstadsvagen 2, SE SKELLEFTEA, Sweden Tel , Fax P17W45_MPREX_F_EN

MANUAL R EXHC RZ EXHC. Verkstadsvägen 2, SE SKELLEFTEÅ, Sweden Tel , Fax

A17W23_MASE_MUS_EN MANUAL

A18W35_MASE 130_F_EN MANUAL

A17W49_MASEM_F_EN MANUAL

Technical Data. Dimensions

Technical Data. Dimensions

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

6-5 Maintenance Manual

DK46 - DK800 Supplementary instructions

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

User Manual. Quantos Automated Dosing Liquid Module

Technical Data. General specifications. Rated operating distance s n 5 mm

Siphon vessel / Priming aid

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

ATEX installation and service instruction

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146

OFFICINE OROBICHE S.p.A. 1/9

PENCOFLEX COUPLING ASSEMBLY AND MAINTENANCE

Table of Contents Documentation for PIT TROLLEY A4

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

(Certification N:o VTT 08 ATEX 066 or IECEx VTT )

Safety Powder Spray Systems

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. Dimensions

Pre-filter for Brushless Blower Instruction Manual

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Powers Controls D Day-Night Thermostats

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Vision Painting Inc Safety Management System

Operating instruction

3/8" Dr. Air Butterfly Impact Wrench

Technical Data. Dimensions

Technical Data. Dimensions

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

BGA244 Binary Gas Analyzer

CleanAIR ARES CA-83. welding leather hood. Contents. 1 General information 2 Use 3 Technical specification 4 Maintenance 5 List of parts 6 Approvals

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

INDICATIONS FOR CHOICE OF ATEX FANS

Diaphragm Pressure Keeping Valve

IP65 Air Differential Pressure Switch

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

FLANGED TWO-PIECE BALL VALVES

Parts and Owners Manual

Operating Instructions

TECHNICAL DESCRIPTION

Operation Manual Advanced-Conventional Pressure Feed Spraygun

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

Operating instructions

Sample Concentrator SBH CONC/1 Instructions for use

RTD Temperature sensor TH11

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

VACUUM REGULATORS CONTENTS

Technical Data. General specifications. Rated operating distance s n 2 mm

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Magnetic level switch type MR783 Instruction Manual

INDICATIONS FOR CHOICE OF ATEX FANS

Operating Instructions

VG5 Supplementary instructions

G10K - 1/2" Heavy-Duty Air Impact Wrench

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

INSTRUCTION MANUAL IS3.003

Title: Abrasive Blasting Effective Date: 11/17/2014 Control Number: THG_0034 Revision Number: 1 Date: 10/22/2015 Annual Review Completed: 5/13/2015

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style

Temperature gauge Installation Guide

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

INTENDED USE TECHNICAL SPECIFICATIONS

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

NEW TYPE M PRESSURE RELIEF DEVICE

Technical Data. Dimensions

Specifications. JIS Symbol 2 port valve 3 port valve (A) 2 (A) 2. Construction. 2 port valve/series VHK2 3 port valve/series VHK3.

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

Air Differentail Pressure Switch

Safety in the Collision Center Paint Department. Safety Tips while working

/ FLT-M Quick Clean Rotary Airlock Valve Operators Manual. Kice Industries, Inc. RAV-M RAV-M

Pressure control, differental pressure control and thermostat Type RT

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

TExT Thorough Examination & Test of LEV Local Exhaust Ventilation Systems

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Arran LED Floodlight Luminaire

User Guide for. UTR Turbo Air Lappers Pneumatic Air Grinders & Lappers UTR-30, UTR-70, UR , ,

VA FLOWMETERS Supplementary Instructions

FLANGED TWO-PIECE BALL VALVES

Instructions for Safe Use

Series AMJ. Drain Separator for Vacuum

CUT OFF TOOL MODEL: CAT113

Transcription:

M18W49_MME100_MUS_EN MANUAL

Contents Important information 3 Applications 3 Technical data 3 Installation and use 4-6 Cleaning 7 Service and repairs 7 Spare parts and accessories 8-9 Testing and troubleshooting 10 Log book for measuring resistance 10 Notes 11 2 Fumex AB, 2017 With provision for changes

Important information NOTE: Read the instructions carefully before installing and using this equipment. The local extractor in the ME EX series is designed to meet the requirements in the ATEX directive 94/9/EC, applicable to equipment intended for use in potentially explosive atmospheres. In order to maintain explosion proof integrity, you must observe the instructions in this manual. Only personnel with the right qualifications may handle this equipment when installing or for service and repairs. Only use original spare parts when repairing the equipment in order to maintain explosion proof integrity. Contact your nearest dealer or head office when purchasing spare parts or if you have technical queries. Note that all other equipment in the explosively hazardous environment must also be intended for use in this environment to avoid any risk of explosion. Applications The local extraction in the ME EX series is intended for use in environments where the atmosphere may be explosive as a result of air and gas mixtures, mist, steam or dust, in otherwise normal circumstances as regards temperature and air pressure. The equipment thereby meets the requirements for equipment category 2 for gas and dust, which means that it is suitable for use in zones 1 or 21, where gas or dust can sometimes be expected to occur. This means that the equipment is also suitable for use in zones 2 or 22, where gas or dust occurs only occasionally. Do not use the equipment in environments where there are substances that attack or react with the material it consists of, see material specification in Technical data, as such substances may degrade the explosion proof integrity of the equipment or cause a risk of explosion when reacting. If in doubt, contact your nearest dealer or head office. The equipment should not be used for non-conductive dust with MIE < 4 mj if there is a risk that the dust is, or could become, highly charged (MIE = Minimum Ignition Energy). Do not hang objects or suchlike on the arm as it is not designed for such purposes. Note that the proprietor is responsible for the classification and zone division of the workplace. Technical data Suitable for use in zones 1, 2 (gas) och 21, 22 (dust) Rec. ambient temperature 50 F to 104 F Dimension Ø4 Material ME EX: Plastic details Damper blade Conductive PP, R< 200kΩ Conductive PP, and TPE 3

Installation and use The equipment can be delivered partially assembled and installed as per the following description. The equipment can be mounted on a wall or to the ceiling using special brackets. Measure a suitable height for the bracket before mounting the arm to the wall, and check that the existing air duct reaches the hose when fitting to the ceiling, see figures. Torx 30 Torx 30 Ø 3/16 1 Torx 30 Ø 5 Ø 5/16 4 1) Fit the wall bracket 2) Instal the arm to the bracket. Fit the ground cables to the wallbracket. Use attachment that is dimensioned for the weight of the arm. Also check that the bearing capacity of the wall or ceiling is adequate.

2 Left Right Torx 30 M6x4 M6x4 3 MET 1150-100* MET 1350-100* MET 1650-100 MET 1900-100 MET 2100-100 MET 2650-100 *No gasspring MEB 1150-100* MEB 1350-100* MEB 1650-100 MEB 1900-100 *No gasspring 4 A B C 5 6 5

5) Ensure that proper electrical contact is made. Connect the ground cable on the bracket to a suitable connection point with the grounding system of the installation. Important: Take the appropriate action if a risk of corrosion has been assessed at the connection point. 6) Tighten the friction joints to an appropriate torque allowing the extraction arm to be easily set and retain its set position without dropping. Where applicable, check that the ground cables across the joints move freely in all directions and that there is no risk of them getting caught in the arm or other objects. Important: Prior to initial operation, the resistance of the arm must have been measured at a satisfactory value as per Testing and troubleshooting and the connection to the earth system must have been checked. NOTE: Personnel working in environments where an explosive atmosphere may arise, as well as all other people that enter the area, must be aware of the risks involved. - Ensure that sparks or objects that may give rise to sparks are not sucked in. - Guard the suction head and supporting arm against impacts from hard objects. - When extracting different kinds of dust in combination, start by ensuring that the mix is not ignitable, such as grinding dust from iron in combination with aluminium dust. - Ensure that objects or people that may be electrostatically charged cannot come into contact with the equipment. - Avoid charging of non-conductive dust. - Avoid hygroscopic dust or dust that may stick - Exercise caution where hybrid mixtures of gas and dust are involved, as they are more easily ignited than the safety data shows individually for the solvent and powder used. 6

Cleaning Clean the extraction arm in the same way as the other equipment at the worksite, however, at least once a year. Clean when there is no risk of explosion in the environment. Observe the risk of electrostatic discharge from people or cleaning tools where there are dust deposits. People are recommended to wear semi conductive shoes and suitable clothing when cleaning where there is dust with MIE < 30 mj. Wear respiratory protective equipment and other appropriate personal safety equipment when cleaning. For dry cleaning: Vacuum and dry externally and internally where necessary. For wet cleaning: Check that the solvent does not attack any of the material used in the equipment, see Technical data. Observe manufacturer dosing instructions. Allow the equipment to dry before using again. Remeasure the resistance to ground as per Testing and troubleshooting before using the extraction arm again. Service and repairs In addition to the routine cleaning, the equipment must be remeasured with respect to the resistance where necessary, or at least twice per year as per Testing and troubleshooting. Remeasure each time the equipment is worked on. You should check the connections at the earth lines, spiral hose and earth point at the same time as the resistance measurement in order to identify any corrosion or loose connections. This is particularly important if the equipment is used in damp or corrosive environments. Carry out service and repairs when there is no risk of explosion in the environment. People are recommended to wear semi conductive shoes and suitable clothing when servicing where there is dust with MIE < 30 mj. Only use original spare parts when needed; see Spare parts and accessories. 7

Spare parts and accessories Always state the type designation and serial number of the arm (see rating plate on arm), the number of required spares and the spare part name and number as per the list below, when ordering spare parts or accessories. Ceiling brackets in EX design are available as accessories for ME EX arms. Fit these according to the instructions in this manual; see Installation and use. Never use any other accessories for ME EX arms as this may jeopardize the explosion protection. Connection tube w/sviwel A-tube L = 17 11/16 A-tube L = 21 5/8 A-tube L = 29 1/2 B-tube L = 13 3/4 B-tube L = 17 11/16 B-tube L = 21 5/8 Complete hood joint Tension knob, black Internal spring Gas spring, tension type Gas spring holder (collar), black Friction ring, connection tube Friction ring, middle joint MET 1150-100EX MET 1350-100EX MET 1650-100EX ME 100322EX ME 100262EX ME 100322EX ME 100261EX ME 100328EX ME 100260EX ME 100277EX ME 100276EX ME 100275EX ME 102154-01 ME 102157-01 ME 100342 ME 100192 Connection tube w/sviwel A-tube L = 39 3/8 A-tube L = 39 3/8 A-tube L = 51 3/16 B-tube L = 21 5/8 B-tube L = 29 1/2 B-tube L = 39 3/8 Complete hood joint Tension knob, black Gas spring, tension type Gas spring Gas spring holder (collar), black Gas spring holder joint mounted Friction ring, connection tube Friction ring, middle joint MET 1900-100EX MET 2100-100EX MET 2650-100EX ME 100328EX ME 100315EX ME 100275EX ME 100344 ME 100192 ME 100328EX ME 100259EX ME 100274EX ME 100344 ME 102116 ME 100192 ME 100990 ME 100009 ME 100328EX ME 100258EX ME 100273EX ME 100346 ME 102117 ME 100912 ME 100990 ME 100009 Connection tube w/sviwel A-tube L = 17 11/16 A-tube L = 21 5/8 A-tube L = 29 1/2 A-tube L = 39 3/8 B-tube L = 13 3/4 B-tube L = 17 11/16 B-tube L = 21 5/8 Complete hood joint Tension knob, black Internal spring Gas spring Gas spring holder (collar), black Gas spring holder joint mounted Friction ring, connection tube Friction ring, middle joint MEB 1150-100EX MEB 1350-100EX MEB 1650-100EX MEB 1900-100EX ME 100322EX ME 100262EX ME 100322EX ME 100261EX ME 100314EX ME 100314EX ME 120883EX ME 120884EX ME 100277EX ME 100276EX ME 100275EX ME 100275EX ME 102157-03 ME 102157-03 ME 120897 ME 100192 ME 100990 ME 100009 ME 120897 ME 100192 ME 100990 ME 100009 8 Always state the type designation and serial number when ordering spare parts or accessories.

MVK MTF 12 1 2 13 MET 1650-100 MET 1900-100 MTI 7 A-tube Gas spring holder (collar) 8 3 10 4 11 Gas spring Friction ring Friction ring Connection tube Tension knob B-tube MET 1150-100 MET 1350-100 Damper Friction ring A-tube Connection tube Friction ring B-tube Complete hood joint Internal spring Tension knob Damper MET 2100-100 MET 2650-100 A-tube Gas spring holder (collar) Complete hood joint Friction ring Gas spring Friction ring Gas spring holder PLACEHOLDER SILVER STICKER Connection tube Tension knob B-tube Damper Complete hood joint 9

Testing and troubleshooting The most important factor for satisfactory explosion protection is that the grounding of the equipment is in good condition. Check this by measuring the resistance with an accurate ohmmeter between the ground connections at the bracket/connection to the extraction duct and suction head. The resistance between the suction head and the ground connection/air duct must not exceed 100Ω. The resistance value should be documented preferably in a log book to facilitate identifying a deterioration of the explosion protection. If the resistance is noticeably higher, the reason for this must be found by measuring the resistance between the connection to the equipment's ground and at different points along the arm, starting with the suction head and step by step in towards the attachment. The fault source will be located as a result. Replace defective components with new, original spare parts. Where there is the slightest doubt, contact your nearest dealer or head office. In the event of reduced suction capacity: check that damper is not closed, that all connections are tight and that the fan is in a satisfactory condition. Log book for measuring resistance Resistans (Ω) Date Resistans (Ω) Date Resistans (Ω) Date 10

Notes 11

104 Commerce Drive, Suit C, NORTHAMPTON, PA 19067, USA Tel 610-440-0478 Fax 610-440-0480 info@movexinc.com www.movexinc.com