INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41

Similar documents
INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28

Your safety and the safety of others are very important.

Installation Instructions

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

ACCESSORY KIT INSTALLATION MANUAL

installation instructions

ACCESSORY KIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions For Natural Gas Conversion

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Natural Gas to L.P. Gas Conversion Kit

Natural Gas to L.P. Gas Conversion Kit

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas

Installation Instructions

INSTALLATION INSTRUCTIONS

/2004 US/CA

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

ACCESSORY KIT INSTALLATION INSTRUCTIONS

SL G3. Warning

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

INSTALLATION INSTRUCTIONS

Propane Conversion Kit Instructions

Installation Instructions

Installation Instructions

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

Instructions for High Altitude Conversion

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

USER S INFORMATION MANUAL

Conversion instructions from natural gas to propane

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Parts List. Qty. Qty.

WARNING: AVERTISSEMENT. LP & HIGH ALTITUDE LP CONVERSION KIT FOR INSTALLATIONS IN the United STATES (0-10,000 Ft)

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Propane Conversion Kit Instruction

Operator: Save these instructions for future use!

GAS CONVERSION KIT Installation Instructions Range/Rangetop

INSTALLATION INSTRUCTIONS

Natural Gas Conversion Kit

Propane Conversion Kit Instruction

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301

INSTALLATION INSTRUCTIONS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36H SERIES Combination Gas Valve

Installation Instructions

Gas Conversion Kit Pilot Ignition Heaters

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Installation Instructions

Propane Conversion Kit Instruction

Gas Valve Replacement Kit

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

WARNING: FOR OUTDOOR USE ONLY

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

Natural Gas Conversion Kit

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

Installation Instructions

VR8205S,T Direct Ignition Combination Gas Controls

Operator: Save these instructions for future use!

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

CASUAL FIRESIDE A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR FIRE PIT FOR PROPANE AND *NATURAL GAS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Operator: Save these instructions for future use!

GM-7000 Series CE Approved Gas Control Valve

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

For *G7 / *GC2 & GUH* / GDD* Series Furnaces & Appliances Using Honeywell Gas Valves

VR8305 Direct Ignition Combination Gas Control

G96 Series BASOTROL Dual Operator Valve

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY

DANGER WARNING IMPORTANT

VR8105, VR8205, and VR8305 Direct Ignition Combination Gas Controls

BGA158 Series CE Approved Class A Shutoff Gas Valve

Installation Instructions

Installation Instructions

VR8200A Continuous Pilot Combination Gas Controls

Installation Instructions

BGA158 Series CE Approved Class B Shutoff Gas Valve

INSTALLATION GUIDE Gas Rangetops

Installation Instructions

VS8420 Millivolt Gas Valve

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

Pressure Dump Valve Service Kit for Series 3000 Units

WARNING IMPORTANT H Identifying the Model, Control Code and Date of Manufacture

Pressure Dump Valve Service Kit for Series 2300 Units

CO2 Tank Conversion Kit P.N , P.N , and P.N

Dual Solenoid Gas Valve Installation

Transcription:

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41 FOR MODULATING DOWNFLOW/HORIZONTAL AND DEDICATED HORIZONTAL MODELS (-GGD, -GGE, -GGF)! Recognize this symbol as an indication of Important Safety Information!! WARNING THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOR- OUGHLY BEFORE ATTEMPTING ANY MAINTENANCE OR OPERATION. FAILURE TO FOLLOW THESE INSTRUC- TIONS CAN RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. FOR CANADIAN INSTALLATIONS, THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURER S AUTHORIZED REPRESENTATIVE, IN ACCORDANCE WITH REQUIREMENTS OF THE MANUFACTURER, PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN/CGA-B149.1 OR CAN/CGA-B149.2 INSTALLATION CODES. RECOMMENDED TOOLS: Slotted screwdriver Needle-nosed pliers 7/16 Socket or wrench 1/4 Nut driver Pipe wrenches (2) Anaerobic Chemical Pipe Sealant (Pipe dope) 90 plus downflow modulating gas furnaces (Rheem/Ruud RGGD/UGGD) installed in high elevations require the installation of a high-altitude kit for proper operation. The high altitude kit consists of a high-altitude pressure switch assembly (two pressure switches in one assembly) which attaches (via a hose) to the induced draft blower. For furnace model -GGD- 06, no pressure switch changes are necessary at any elevation; therefore, there is no high altitude kit available for this model. For furnace model -GGD-07, the pressure switches must be changed at elevations greater than 8,000 ft. For furnace models -GGD-09, -10 & -12, the pressure switches must be changed at elevations above 5,000 ft. For ALL furnace models, an orifice change may be necessary depending on the elevation and the gas heating value. As an example, even though there is no kit available for the -GGD-06 furnace model, it may still require an orifice change depending on the elevation and gas heating value. Elevations above 2000 ft. require the furnace to be de-rated 4% per thousand feet. This means that for every thousand feet of elevation, the furnace loses 4% of its heating capacity. Burner orifices must be adjusted in order to achieve the reduced rates. NOTE: Factory installed orifices are calculated and sized based on a sea level Natural Gas heating value of 1075 BTU per cubic ft. Regional reduced heating values may nullify the need to change orifices except at extreme altitudes. Consult the section titled Orifice Selection for High Altitude Applications of this document to determine if an orifice change will be necessary and what the new drill size will be for the orifices. The high altitude kit consists of a high altitude pressure switch assembly that replaces the pressure switch assembly attached to the induced draft blower. The kit no longer contains additional orifices for high altitude applications as these may or may not be necessary and, if necessary, could be any of a number of different sizes. Please consult the section titled Orifice Selection for High Altitude Applications of this document for information on calculating the proper orifice drill size and where to order the necessary orifices. Kit Selection: RGGD/UGGD HIGH ALTITUDE FIELD CONVERSION Based on the furnace model number, the proper kit to use must be selected from the list below. Dedicated Downflow and Combination Downflow/Horizontal Models MODEL INPUT (BTU) KIT NO. ALT. OF SWITCH CHANGE -GG(D,E or F)-06 60,000 NONE NA -GG(D,E or F)-07 75,000 RXGY-F23 8000 ft -GG(D,E or F)-09 90,000 RXGY-F24 5000 ft -GG(D,E or F)-10 105,000 RXGY-F25 5000 ft -GG(D,E or F)-12 120,000 RXGY-F26 5000 ft Dedicated Horizontal Models Only MODEL INPUT KIT NO. ALT. OF SWITCH (BTU) CHANGE -GJ(D or F)-06 60,000 NONE NA -GJ(D or F)-07 75,000 RXGY-F38 8000 ft -GJ(D or F)-09 90,000 RXGY-F39 5000 ft -GJ(D or F)-10 105,000 RXGY-F40 5000 ft -GJ(D or F)-12 120,000 RXGY-F41 5000 ft 92-24096-04-04 SUPERSEDES 92-24096-04-03

FIGURE 1 HONEYWELL PRESSURE SWITCH ASSEMBLY WITH CORRECT MOUNTING HOLES INDICATED. NOTE: MOUNT WITH ELECTRICAL TERMINALS FACING TO THE FRONT OF THE FURNACE. MOUNTING HOLES FOR -GGD MODELS FIGURE 2 MPL PRESSURE SWITCH ASSEMBLY WITH CORRECT MOUNTING HOLES INDICATED. MOUNTING HOLES FOR -GGD MODELS FIGURE 3 MPL PRESSURE SWITCH ASSEMBLY USED ON (-)GJD & (-)GJF FURNACE MODELS 2

A NOTE ABOUT DIFFERENT PRESSURE SWITCH ASSEMBLIES FOR -GGD/-GGE/-GGF FURNACE MODELS: There are two different possible manufacturers of pressure switch assemblies; Honeywell and MPL. For downflow models, the Honeywell Assembly is shown in Figure 1 and the MPL assembly is shown in Figure 2. These assemblies are interchangeable with each other. Do not be alarmed if the replacement pressure switch assembly does not exactly match the existing assembly. As long as either assembly looks like one of the assemblies in either Figure 1 or 2, there should not be a problem. PROCEDURE: CHANGING PRESSURE SWITCH ASSEMBLIES! WARNING 1. DISCONNECT THE MAIN ELECTRICAL POWER TO THE UNIT BEFORE ATTEMPTING ANY MAINTENANCE. FAILURE TO DO SO CAN CAUSE ELECTRICAL SHOCK RESULTING IN SEVERE PERSONAL INJURY OR DEATH.! WARNING 2. SHUT OFF THE GAS SUPPLY AT A MANUAL VALVE IN THE SUPPLY PIPING TO THE UNIT BEFORE ATTEMPT- ING MAINTENANCE. FAILURE TO DO SO CAN CAUSE FIRE OR AN EXPLOSION RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. 3. Turn the thermostat to the off position. 4. Remove the burner door. FIGURE 4 REMOVE THE HOSE FROM THE INDUCER (MPL ASSEMBLY SHOWN) TO REPLACE THE PRESSURE SWITCH: 5. Remove the wiring from the existing pressure switch assembly. See Fig 5. 6. Disconnect the pressure switch hose that connects to the induced draft blower. See Figure 4. FIGURE 5 REMOVE WIRES FROM SWITCH ASSEMBLY (MPL ASSEMBLY SHOWN) 7. Remove the pressure switch assembly by removing the two screws that attach the assembly to the blower shelf. 8. Use the existing screws to mount the high altitude pressure switch to blower shelf. 9. Reattach the hose from the induced draft blower to the replacement pressure switch assembly. 10. Reattach all wires to the replacement pressure switches. Reference the wiring diagram attached to the unit. 11. If conversion requires an orifice change, continue on to next section. If not, replace the door, turn on the electrical power and the main gas supply to the unit. Set the thermostat at a temperature which will cause the unit to operate in heat mode. Let the furnace operate through several cycles to confirm proper operation. AT CERTAIN ELEVATIONS, BOTH THE PRESSURE SWITCH ASSEMBLY AND THE ORIFICES MUST BE CHANGED. FOL- LOWING IS A PROCEDURE FOR DETERMINING AT WHAT ELEVATION THE ORIFICES WILL NEED TO BE CHANGED AND WHAT DRILL SIZE THEY MUST HAVE. THE INSTRUC- TIONS ARE BASED ON ALTITUDE AND GAS HEATING VALUE. THE INSTALLER WILL NEED TO DETERMINE BOTH THE ELEVATION AND THE HEATING VALUE (BTU/FT 3 ) OF THE GAS AT SEA LEVEL BEFORE MAKING THE CALCULA- TIONS. TABLE 1 NATURAL GAS ORIFICE DRILL SIZE (4% PER 1000 FT. DE-RATE) BURNER INPUT (PER BURNER) 15,000 BTU @ SEA LEVEL Annual Avg. Heat Value (btu per ft 3 ) 850 900 1000 1075 1170 Sea level to 2000 to 3000 to 4000 to 5000 to 6000 to 7000 to 8000 to 1999 ft. 2999 ft. 3999 ft. 4999 ft. 5999 ft. 6999 ft. 7999 ft. 8999 ft. 47 48 48 49 49 49 50 50 48 49 49 49 50 50 50 51 49 50 50 50 51 51 51 52 50 51 51 51 51 52 52 52 51 51 52 52 52 53 53 53 3

ORIFICE SIZE ADJUSTMENTS NEED TO BE CALCULATED AND APPROPRIATE ORIFICES INSTALLED BASED ON THE ACTUAL HEATING VALUE AND ALTITUDE USING GUIDELINES SET FORTH BY THE NATIONAL FUEL GAS CODE and NATURAL GAS AND PROPANE INSTALLATION CODE (CANADA). ORIFICE SELECTION FOR HIGH ALTITUDE APPLICATIONS! CAUTION The National Fuel Gas Code (NFGC) and (for Canada) The Natural Gas and Propane Installation Code and Gas-Fired Appliances for Use at High Altitudes (CGA 2.17-M91) guidelines should be followed when converting these furnaces for high altitude operation. Examples of orifice sizing using the National Fuel Gas Code Appendix F: In addition to any necessary pressure switch changes, installations at elevations above 2000 ft. require the furnace to be derated 4% per thousand feet. Note that #50 factory installed orifices are calculated and sized based on a sea level Natural Gas heating value of 1075 BTU per cubic ft. Regional reduced heating values may nullify the need to change orifices except at extreme altitudes. Table 1 shows some quick conversions based on elevation and gas heating value. This table is combined and simplified from Tables F1 and F4 of the NFGC. IMPORTANT: TO CALCULATE THE NEW ORIFICE SIZE, THE EQUIVALENT HEATING VALUE OF THE GAS AT SEA LEVEL MUST BE KNOWN. THE VALUE MUST BE THAT OF SEA LEVEL BEFORE ANY CALCULATIONS ARE PER- FORMED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. Example 1: 90+ Furnace with 900 BTU/ft 3 Regional Natural Gas Heating Value I / H = Q 15000 / 900 = 16.68 ft 3 /hr I = Sea Level input (per burner): 15000 (btu/hr) H = Sea Level Heating Value: 900 (btu/ft 3 ) Q = 16.68 ft 3 /hr Natural Gas From Table F.1 of National Fuel Gas Code Handbook, 2002 (3.5 w.c. column). Orifice required at Sea Level: # 48 (From Table F1 NFGC) From Table F.4 of National Fuel Gas Code Handbook, 2002 Orifice required at 5000 ft. elevation (4% de-rate per thousand ft): # 50 (Table F4 NFGC) Orifice required at 8000 ft. elevation (4% de-rate per thousand ft): # 51 (Table F4 NFGC) Example 2: 90+ Furnace with 1050 BTU/ft 3 Regional Natural Gas Heating Value I / H = Q 15000 / 1050 = 14.63 ft 3 /hr I = Sea Level input (per burner): 15000 (btu/hr) H = Sea Level Heating Value: 1050 (btu/ft 3 ) Q = 14.28 ft 3 /hr Natural Gas. From Table F.1 of National Fuel Gas Code Handbook, 2002 (3.5 w.c. column). Orifice required at Sea Level: # 50 From Table F.4 of National Fuel Gas Code Handbook, 2002 Orifice required at 5000 ft. elevation(4% de-rate per thousand ft): # 51 (Table F4 NFGC) Orifice required at 8000 ft. elevation (4% de-rate per thousand ft): # 52 (Table F4 NFGC) LP Gas LP Gas is a manufactured gas that has consistent heating value across most regions. The NFGC guidelines are used with the following exception: The recommended LP Gas high altitude orifice selections differ slightly in that the NFGC LP orifice chart, as they are not accurate for Rheem products. The National Fuel Gas Code LP orifices are based on an 11 of water column pressure at the orifice, which differs from Rheem products that use 10 of water column at the orifice. This difference requires a deviation from the NFGC orifice size recommendations. The Sea Level input should still be reduced by 4% per thousand ft. and the orifice size must be selected based on the reduced input selection shown in Table 2. TABLE 2 LP GAS ORIFICE DRILL SIZE AND PER BURNER DE-RATE BY ELEVATION BASED ON 15,000 BTU RHEEM 90+ BURNERS. Altitude Input (BTU per burner) 25000 Orifice Size 0 to 2000 ft 15000 1.15 mm (factory) 2001 to 3000 13200 1.15 mm 3001 to 4000 12600 1.10 mm 4001 to 5000 12000 #58 5001 to 6000 11400 #59 6001 to 7000 10800 #60 7001 to 8000 10200 #62 8001 to 9000 9600 #63 9001 to 10000 9000 #64 Orifice Ordering Information Orifice sizes are selected by adding the 2-digit drill size required in the orifice part number. Drill sizes available are 39 though 64; metric sizes available 1.10mm (-90) and 1.15mm (-91): Orifice Part Number 62-22175-(drill size) Example 1: # 60 drill size orifice required Part # 62-22175-60 Example 2: 1.15mm drill size orifice required Part # 62-22175-91 TO REPLACE THE ORIFICES: Once it has been determined (using the methods above) that orifices need to be changed, the following procedure should be followed to replace the orifices.! WARNING 1. DISCONNECT THE MAIN ELECTRICAL POWER FROM THE UNIT BEFORE ATTEMPTING ANY MAINTE- NANCE. FAILURE TO DO SO CAN CAUSE ELECTRI- CAL SHOCK RESULTING IN SEVERE PERSONAL INJURY OR DEATH. 4

! WARNING 2. SHUT OFF THE GAS SUPPLY AT A MANUAL VALVE IN THE SUPPLY PIPING TO THE UNIT BEFORE ATTEMPTING MAINTENANCE. FAILURE TO DO SO CAN CAUSE FIRE OR AN EXPLOSION RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. 3. Disconnect the gas supply line from the system at the union inside the furnace. 4. Remove all necessary wiring to permit removal of the manifold assembly. 5. Remove the four screws holding the gas manifold to the burner brackets and remove the manifold assembly. See Figure 5. FIGURE 6 REMOVE THE MANIFOLD ASSEMBLY 6. Remove the existing orifices from the manifold using a 7/16 socket or wrench. See Figure 6. 7. Replace the orifices with the proper high-altitude orifices. Screw them in hand tight and secure in place (with the wrench or socket) 1/4 turn from hand tight. 8. Replace the manifold assembly on the burner assembly with the four screws removed in step 5. 9. Replace all wiring removed in step 4. 10. Re-attach the gas line at the union. Tighten securely with a pipe wrench. IMPORTANT: When tightening gas pipe connections, use a back-up wrench to prevent any twisting of the control assembly and/or the gas valve. 11. Turn on the gas at the manual gas valve and check for any leaks using soap and water solution or other approved method.! WARNING DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS. USE OF AN OPEN FLAME CAN CAUSE A FIRE OR EXPLO- SION RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. 12. Turn on the electrical power to the unit. Set the thermostat at a temperature which causes the unit to operate in the heat mode. Let the furnace operate through several cycles to confirm proper operation. INSTALL THE CONVERSION LABEL Once all other work has been done, install the High Altitude Conversion Label supplied in the kit (part number 92-101842- 01). This label must be installed and properly filled out to complete the job. The label includes information about elevation, manifold pressure and etc to indicate that the furnace has been properly converted by the installer for the particular installation in question. The label must be filled out by the installer. FIGURE 7 ORIFICE REMOVAL 5

6

7

8 CM 0609