Capillary Flow Porometer/Frazier/C-522 CFP-1100AEX-F-C522

Similar documents
THE PMI ADVANCED PERM POROMETER

THE PMI ADVANCED CAPILLARY FLOW POROMETER

CAPILLARY FLOW POROMETER CFP-1500AL. Not just products... solutions.

Frazier Permability Tester & Average Fiber Diameter Analyzer. Permeability measurement according to ISO: 4003 & ASTM D standard

PMI ADVANCED AUTOMATED HYDRAULIC PRESSURE LEAK TESTER APCS-H-60K. Not just Products... Solutions!

PMI Advanced Automated. Pulse Decay Permeameter APDP-10K-HP-101. Not just products... Solutions!

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

THE MARKET LEADER IN CAPILLARY FLOW POROMETRY CFP1

PMI Pulse Decay Permeameter for Shale Rock Characterization Yang Yu, Scientist Porous Materials Inc., 20 Dutch Mill Road, Ithaca NY 14850

POROMETER 3G POROMETER. through-pore size analyzer. Membranes. Filters. Non-Woven. Textiles. Papers. Ceramics. Sintered Metals SERIES

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

HumiSys HF High Flow RH Generator

US A1 (19) United States (12) Patent Application Publication (10) Pub. No.: US 2005/ A1 Gupta et al. (43) Pub. Date: Oct.

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Automatic Isokinetic Sampler. ST5 Evo

tel: fax: web:

Triaxial automated systems

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

PMI Advanced Media Bubble Point Tester

Project Title: Pneumatic Exercise Machine

Automatic Isokinetic Sampler. ST5 Evo

Tensiometer For the measurement of surface and interfacial tension

Determination of Capillary pressure & relative permeability curves

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display: Quick connect spindles:

Complete Range of Force Tensiometers

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Series Environmental Chambers

Level MEASUREMENT 1/2016

AUTOMATIC HOSE TEST UNIT, TYPE SPU

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

RM-80 respiration monitor

Agilent Flowmeter ADM1000

Pressure calibration equipment

Digital deadweight tester Model CPD8500

PTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3

Tensiometer For the measurement of surface and interfacial tension

Pressure calibration. 20

ACTUATORS AND INSTRUMENTS

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

COSMO INSTRUMENTS CO., LTD.

Pressure Measurement

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Florida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES

SPH 4C Unit 4 Hydraulics and Pneumatic Systems

Air permeance of paper and paperboard (Sheffield method)

[Graphic Division] 10

Hydraulic pressure balance Model CPB5800

Series 2G Diaphragm Actuators

How to specify a product. Process Sensors and Mechanical Instruments

Using PV Diagram Synchronized With the Valve Functioning to Increase the Efficiency on the Reciprocating Hermetic Compressors

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Ultrasonic level transmitter and indicator

Modeling Case Study: Surge Tanks, Valves, Level sensors, and modeling

ABRASIVE REGULATOR II

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Air Operated Hydraulic Pumping Systems to 50,000 psi

High flow rate. Cost effective. Compliant. Gripper with GSW-B Shaft Interface and Compensation Unit

628 Differential Pressure Decay Leak Tester

CAPITAL CONTROLS SERIES NXT3000

CONTROL VALVE TESTING

Gripping modules Pneumatic 2-finger parallel gripper Long-stroke gripper for small components Gripping force 120 N..

PERME- OX2/230 Oxygen Transmission Rate test system

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

TECHNICAL DATA. Page 1 of 12

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Design of an Automated Perfusion Pump James J Higham

Design Features. General Description

The Discussion of this exercise covers the following points:

Porter Analytical & Industrial Products

UNIVERSAL MASK TEST SYSTEM

PSH (inch version) Application example. Pneumatic 2-Finger Parallel Grippers Long-stroke Grippers. Stroke per finger 14 mm.. 64 mm. Sizes 22..

Additel 780 Series Pressure Controller

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Plant, components and devices for very high and high pressures (7000 bar and over)

Operations Manual. Internal automatic Pressure control for orbital tube welding. By Exel Orbital Systems, Inc. Page

Pressure Calibrators. Series PC..., PM...

High Pressure Breathing Air Compressors

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

FlexAct BT (Bag Tester) Validation November, 2015

SEMEM3-78 Testing and calibrating instrumentation and control equipment and circuits

CHAPTER 3 RESULTS AND DISCUSSION

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

Ideal gas law. Introduction

Hardware Triaxial and Consolidation Testing Systems Pressure Measurement and Control

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

Setting a New Standard in Flash Chromatography Performance

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display:

PHYSICS ENTERPRISES TEACHING EQUIPMENT FOR SCIENCE

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

NR-Tec Ltd. S2S SMARTSHOT Acoustic Fluid Level Instrument

PTFE-SINGLE GLASS FLOW METERS

Primary standard differential pressure balance Model CPB6000DP

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Pressure Sensor Experiment Guide

Transcription:

Capillary Porometer/Frazier/C-522 CFP-1100AEX-F-C522 Not just products...solutions!

PRINCIPLE (CFP) A wetting liquid is allowed to spontaneously fill the pores in the sample and a nonreacting gas is allowed to displace liquid from the pores. The gas pressure and flow rates through wet and dry samples are accurately measured. The gas pressure required to remove liquid from the pores and cause gas to flow is given by: D = 4γ cos θ/p where, D is the pore diameter, γ is the surface tension of liquid, θ is the contact angle of liquid, and p is the differential gas pressure. From measured gas pressure and flow rates, the pore throat diameters, pore size distribution, and gas permeability are calculated. DESCRIPTION (GP-C522) The PMI GP-C522 follows the specifications of ASTM C522-03 and provides quick and accurate resistivity values in Rayls. Air is forced through the material at required velocity or flow rate and corresponding pressure drop is measured to provide the resistivity valves. The PMI GP-C522 provides direct Rayl values to be used by QC and R&D engineers working on acoustic damping materials for various s. Specific Airflow Resistance is defined as the product of the airflow resistance of a specimen and its area. This is equivalent to the quotient of the air pressure difference across the specimen divided by the linear velocity, measured outside the specimen, of airflow through the specimen. DESCRIPTION (Frazier) Our Advanced Frazier Permeability Tester is used to determine the permeability of porous solids. A gas such as air is forced to flow through the test sample. easurements of the steady-state flow rate and the corresponding pressure drops provide the necessary data for calculation of the Permeability using darcy, Liters per minute, Frazier and other units.

FEATURES (CFP) Testing of small samples as well as complete parts Any nonwetting liquid Real time graphic display Straight flow path avoiding turbulence Versatile sample chamber for a variety of samples and test modes Tests in QC, research, or any number of user defined modes See-through sample chamber for visual observation of test available Any sample geometry (Example: sheets, rods, tubes, hollow fibers, cartridges, & powders) Window based software for all control, measurement, data collection, data reduction, and report preparation Adjustable pressure on O-rings through pneumatically controlled piston-cylinder device Measurement of pressure close to the sample to minimize pressure drop correction FEATURES (GP-C522) FEATURES (Frazier) Compatible with Windows 97 or higher Fully automatic Non-destructive testing Length of test approximately 1 minute Wide range of acceptable sample types and sizes Multiple sample chambers available Minimal maintenance required Units in Frazier, Darcy, Coresta, Rayl matic, pneumatic sample clamping Interchangeable test head and adapter plates Permeability measurement according to ISO: 4003 & ASTM D 3574 standard Windows-based software handles all control, measurement, data collection, and report generation; complete manual control also possible Comes with a PC computer equipped with real-time graphical LCD test display that depicts testing status and results throughout operation Non-destructive testing Length of test approximately 10 minutes Minimal maintenance required Multiple sample chambers available Real-time graphical test display depicts testing status and results throughout operation Windows-based software handles all control, measurement, data collection, and report generation; complete manual control also possible

SPECIFICATION Pressure Accuracy: 0.15% of reading Test Pressure: 100, 200, and 500 psi instrument versions (700, 1400, 3500 kpa nstrument versions) Pressure & Resolution: 1/60,000 of full scale (1 part in 60,000) Maximum Pore Size Detectable: 500 mm Minimum Pore Size Detectable: Varies with intrusion liquid Rates: Up to 200 SLPM (liters per minute) Sample Geometry: Sheets, Rods, Tubes, Hollow Fibers, Cartridges, Powders Sample Sizes: Standard: 0.25-2.5 diameter (up to 1.5 thick) Standard: 5 mm - 60 mm diameter (up to 40 mm thick) *Others available C-522 Permeability: Frazier Permeability: Permeability Range: 100-10,000 Mks Rayls Permeability measurement according to ISO: 4003 & ASTM D 3574 standard Sample Size: 5 cm³ to 100 cm³ test area Pneumatic Clamping: (180±30)N Pressure Range: Up to 138 inches of water column Pressure controller: 0.5 ± 0.1 inches of water Accuracy: 0.15% of reading Mass Transducer Range: upto 500 liters per Pressurizing Gas: Clean, dry or compressed air (or any other non-flammable and non corrosive gas) Pressure Transducer Range: 0-500 PA Resolution: 1-60,000 Accuracy: 0.15% of reading Mass Transducer Range: 10cm³/min50,000 cm³/min minute Pressurizing Gas: Clean, dry or compressed air (Or any other nonflammable and noncorrosive gas) Parameters CFP 1100A CFP 1200A CFP 1300A CFP 1500A Standards Measuring principle Pore size min 0.1 microns 0.05 microns 0.02 microns 0.01 microns Max Pressure range 100 psi 200 psi 300 psi 500 psi Sample size standard (1.5 / 40mm thick) Unique Sample Chamber Sample geometries, (optional) rate available available available available resolution Pressure controller, each, each, each, each Pressure sensors Pressure regulator switch

PMI SOFTWARE We work closely with our customers to provide the most user friendly software for porometery. PMI Capwin software is updated to meet customer needs & requirements. The comprehensive software can be used for all PMI porometers. The software is customized to offer convenient operation with default setting tor beginners & full access to ail relevant measuring parameters for advanced researchers: Capwin manages manual instrument control, automated measuring routines ( jobs ) and report print out or graph Capwin Data manager for interactive evaluation of measured data as well as providing sophisticated tools forcreating reports & generating templates for graphs, tables & screen views Capwin user manager for comprehensive user management regarding useraccess, control & assignment of specific jobs On Iine diagnostic from anywhere in the world User defined definitions of paths & sub directories for data filling SALES & SERVICES Our sales team is dedicated to helping our customers find which machine is right for their situation. We also offer custom machines for customers with unique needs. To find out what we can do for you, contact us. We are committed to customer support including specific service products, short response times & customer specific solutions. To quickly & flexibly meet our customer's requirement, we offer a comprehensive range of services. CUSTOMIZE YOUR MACHINE TODAY Disclaimer : *Other specifications of this product are also available.

The most advanced, accurate, easy to use and reproducible Porometers in the world. U PRO DLY Email: info@pmiapp.com www.pmiapp.com M AD S E IN U A 20 Dutch Mill Rd, Ithaca, NY 14850, USA Toll Free (US & Canada): 1-800-TALK-PMI (1-800-825-5764) Phone: 607-257-5544 Fax: 607-257-5639