Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Similar documents
Super-Clean SCT Series SuperClean Sand Filter. Installation Manual

After filling the pool with clean water in the summer, two basic factors can take place due to the exposure of water to the sun and the air.

Sand Dollar Filter Owner s Manual IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

LIBERTY and PATRIOT SAND FILTER SERIES INSTALLATION & OPERATION MANUAL. RX Clear Patriot Sand Filters

LAMINATED SAND FILTERS Filtering Equipment. Manufactured in Spain for PQS Piscinas y Consumo SA

Cristal -Flo II Filter OwnerÕs Manual

PRAHER PLC-MP AQUASTAR MANAUL 2009

Pool Information 2015

POOL ROVER ST POOL CLEANER Installation Instructions

VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

CLEARPRO TECHNOLOGY FILTER LATERALS EXTENSION KITS

Vessel Installation and Operating Manual

Installation manual Sfera Combo

UsER manual for Watersens ph -REDOX

Budget Range Operators Handbook

Assembling & Installing your Pool Cleaner

ST1600 SAND FILTER PUMP

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Easy Nest Kits. Installation Suggestions

Installation and Operating Manual

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

accidents which arise due to non-observance of these instructions and the safety information herein.

Eaton Filtration, LLC

MAINTENANCE PROCEDURE FOR X 650

Eaton Filtration, LLC

SILENTAIRE TECHNOLOGY

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

Installation of Your SprayMaster System

OWNER S TECHNICAL MANUAL

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

WARNING! Equipment for treatment of water intended for human consumption (Directive 98/83 CE).

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

HGC-200 Hydro Gas Chlorinator

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Booster Pump PB4-60 Replacement Kits

OPERATING MANUAL LO-CROSS-FLOW CF M

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

POOL CARE GUIDE. The E-Z Clor System To Perfect Pool Water.

VERTICAL AIR COMPRESSORS

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Advanced Fluid Handling Cart Owner s Manual

Purifier for Vinyl Lined Pools

Installation and Operation Manual

200 PSI COMPRESSORS - MODEL NUMBERS

100C Air Compressor Kit

Portable Oil Lube Air Compressors

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

Calcium Reactor. CalcFeeder PRO. User Manual 1.1a. Model. CalcFeeder AC1 PRO CalcFeeder AC2 PRO CalcFeeder AC3 PRO CalcFeeder AC4 PRO

START UP MANUAL MADE IN USA REV US and Foreign patents and patents pending see

Operating Instructions Models and Hydrostatic Test Pumps

Arcadia Spas User Manual

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

ALF400 to 900, ALT-5/-9

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

AIR COMPRESSOR MANUAL INSTALLATION, OPERATION AND MAINTENANCE GUIDE

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

NIV EAU MATIC ST User Manual Made in Canada

MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX)

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 3000 Units

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Y:\Machine Manuals & Spare Parts Lists\PARTS BREAKDOWN\Commercial CW Gas\HD850WS Page 1

KREEPY KRAULY WARRIOR SUCTION SIDE POOL CLEANER

IT S TIME TO PLAY! Owner s Guide A&A BUILT-IN POOL CLEANING AND CIRCULATION SYSTEMS

Installation, Operation & Maintenance Instructions

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

VERTICAL AIR COMPRESSORS

SILENTAIRE TECHNOLOGY

200L BELT DRIVEN AIR COMPRESSOR

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

Automatic Pool Cleaner

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Owner s Manual W Automatic Aboveground Pool Cleaner

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Installation and commissioning instructions 255 series and 256 series

15ME-014 INSTRUCTION MANUAL OF STERN TUBE SEALING TYPE EVK2RV. URL

INSTALLATION INSTRUCTIONS

Service and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13

SEP 100 D.E. SEPARATION TANK

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Transcription:

Installation and Maintenance Manual ECO Filtration Unit with 6-way-Top-Mount-Valve Art. Nr. 300100 300101 300102

Important Details: - Using of this filtration unit for swimming pools and its guard band if they are constructed in VDE 0100-49D. - Please ask your specialised dealer or your electrician. - More details you will find in the manual for the pump. Attention to avoid damages: - Never let the pump run dry. - Only use the 6-way-valve if the the pump is switched off.

BEFORE CONNECTING THE FILTER 1.1 LOCATION Serie ECO Place the filter on a flat, solid surface at a minimum distance of 3,5 metres from the pool, (in accordance with standard of the region or country) and at the same level as the bottom of the pool to prevent air from entering the cleansing circuit and the filter from becoming unprimed. The filter should be protected from sun and rain, and kept it in an area with sufficient ventilation during operation. Never cover it during operation. 1.2 ASSEMBLY After the filter has been set into place, proceed as follows: You will find instructions sheets with the equipment which show you the steps to follow when starting to assemble the equipment Before putting in sand, place the inner collector properly centered on the bottom of the filter. Sand filling: The silica sand lasts for an unlimited period of time and should only be replaced in the event of sand loss. Record the sand level for future replacement. Keep the remaining sand in the bag in a dry place. Eliminate the remains of sand from the filter opening and remove the protective plastic. Place the TOP selector valve with its coupling and secure with the plastic band or seal following the diagrams in the instructions attached to the metal plastic. Tighten firmly the screw on the plastic ban, which joins the valve to the filter. Cover the opening of the inner collector tube with protective plastic in order to prevent sand from entering the tube. Connect the suction and discharge hoses to the suction and discharge terminals on the valve, thightening them firmly with the clamps. Insert the Teflon supplied with the thread of the skimmer terminal and connect the other end of the suction hose. Tighten firmly with a clamp. Repeat the same procedure with the feedback nozzle terminal and connect the discharge hose. Following installation, the first cycle of filter backwash should be performed. In order to do so, follow the instructions in the section 4.3. 2 ELECTRIC CONNECTION All electrical Installations should comply with the following standard: NF C15-100 NF EN 60-335-2-41 that refers to the construction of the electrical Installations, both in indoor and outdoor swimming pools, or the equivalent standard in force in each region or country.

The pump must be connected to a 220/230 V. alternating current and 50 Hz power point, with earth connection. Consumption: 240 W. An omnipolar switch must be used to ensure there is no power feed to the filter when it is not in use. A 30 ma differential must also be used to protect from electrical breakdowns. (Not supplied. These items can be purchased at electricity shops.) 3 TOP SELECTOR VALVE The selector valve is responsible for selecting the 6 different filter functions: backwash, recirculation, rinse, filter, waste, and close for the model Bali. To change the valve setting, proceed as follows for model Bali: Always disconnect the power socket. Press firmly on the upper valve control until the front rib is released from its housing and it can turn on its own axis. Gently turn the control until the front rib is aligned with housing for the desired operation. Release the control gradually and check that the front rib is fully inserted in the appropriate housing. 4 OPERATION The operation of this filter is based on the filtration capacity of the silica sand which is inside. The water in the pool is driven by the filter pump and forced to pass through the sand. The sand acts as filtering element which retains the impurities in the water. The environment, trees, pollen, insects and frequency of bathing, as well as other factors, determine the dirtiness of the water in the pool. Depending on the dirtiness, the sand in the filter should be cleaned with greater or less frequency. To maintain the pool water in good condition, use the chemical products recommended by the manufacturer (chlorine, alga protection, flocculant etc.)., The chemical product should never be placed in the basket or through the filter, this would deteriorate the materials of the unit and limit its efficacy. 4.1 PRIMING THE FILTER The filter must be correctly primed at all times. If the filter is not primed this means that an air chamber has been created inside which causes defective circulation of water. This fact prevents proper filtration of the water by the sand and is detrimental to the motor. The filter may become unprimed for several reasons: Starting up a new unit. Starting up a unit after an extended period of inactivity. Following use of a suction bottom cleaner. Air absorbed by the skimmer due to the low level of water in the pool. Due to incorrect use of the unit, suction cover or skimmer plug.

4.2 FILTRATION NEVER HANDLE THE VALVE WHILE THE MOTOR IS RUNNING!!! Before the first filtration operation, perform a backwash of the sand (section 4.3). The valve must be on the filtration setting. The service of the filter will be longer if the periods of continuous operation do not exceed 4 hours. The need for daily filtration is determined by the volume of water in the pool in m³ in comparison to the m³/h filter flow rate for a water temperature of around 21 C and placed at 3,5 m from the pool. Leave the motor at off for at least 2 h. Between each 4 h period of operation. Volume of the pool in m³ Filter flow in m³/hr. Example: 42 m³ = 7.63 hours 2 cycles of 4 hours with an intermediary cycle of hours rest 5,5 m3/h In the initial filtration treatment it is important to leave the filter off for the time indicated. It is recommended to increase the filtration time the higher the water temperature of the pool. 4.4 SAND FILTER BACKWASH The backwash process cleans the sand from inside the filter. This process should be done regularly. For the purpose you should observe several factors which indicate the dirtiness of the sand: Decrease in the flow of feedback is detected, after checking that the pump is well primed. Pressure gauge indicates that there is excess pressure (needle pointing between yellow and red, or on red). 4.4 DRAINING THE SWIMMING POOL The filter allows you to drain the pool almost completely after the bathing season has ended. To do so, place the upper selector valve on the waste setting. Before plugging in the filter, connect the d 38 mm x 1.5 m hose to the valve waste outlet and point the other end of the hose towards a drain or sewer. 4.5 CLEANING THE POOL BOTTOM In order to clean the pool bottom, use the pump filter with one suction cleaner. You will also need a d 38 mm hose and the pole. To purchase these items, consult your establishment or ask the After-Sales Service provided by the pool manufacturer. Always use original replacements parts. A hose which extends beyond the length required to reach all points of the pool is more difficult to use. Cut off the section of the hose which is not needed. Check that the rubber terminals conserve their seal.

4.6 RINSING After WASHING the filter and placing the installation in the FILTERING position, the water flowing to the pool will be cloudly for a few seconds. To avoid this cloudly water from circulating in the swimming pool, the RINSING operation should be performed as follows. Immediately after WASHING, stop the pump, place the selector valve in the RINSING Fig. 5, position and connect the pump for 1 minute. After this time, stop the pump and place the valve in the FILTERING position. 4.7 RECIRCULATION In this position the selector valve allows the water from the pump to go directly to the swimming pool without passing through the inside of the filter. 4.8 CLOSED The CLOSED setting of the selector valve is used to prevent water from circulating through the hoses and the filter. 5 MAINTENANCE After the bathing season has ended, the filter should be kept in a dry place where it is protected from inclement weather. For this purpose, after performing a final backwash to clean the sand, dismount the hoses and drain the water in the filter through the tank drain plug until it is completely empty. After removing all of the water from the filter, carefully clean the remains of sand from the thread before replacing the plug. Failure to do so could damage the thread. The filter tank drain plug should only be used in this operation. VERY IMPORTANT: Following an extended period of inactivity, before starting up the filter check that the drive shaft is not jammed. Remove the protective housing. After winding the motor, use a flat screwdriver to move it by the end which is visible through the metal ventilation cover, until it is released and the shaft turns to the right and the left. If it does not turn, clean the wheel of the turbine.. After stoppage for an extended period, it is also recommendable to make sure that the filter is primed before starting up.