TABLE OF CONTENTS. Solution Mixing...pg. 2 Components...pg. 3 Set-Up...pg. 4 Operation...pg. 5 Toubleshooting...pg. 6

Similar documents
Operating Instructions Model and Hydrostatic Test Pump

User's Manual. MixRite TF 10. Edition 05.08

Operating Instructions Model and Hydrostatic Test Pump

STREAMLINE SHOP SERIES MODEL 30040V OPERATION & PARTS MANUAL

Rejuvenation Instructions

PRO SINK -R 1 and 2. Dilution system CONTENTS

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Operating Instructions Models and Hydrostatic Test Pumps

VRS Assembly & Operating Instructions

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1

Geotech 1.66 Auto-Reclaimer Installation and Operation

Geotech 1.66 Auto-Reclaimer

VERTICAL BLADDER TANK

Livewell/Baitwell Pumps. Livewell/Aerator

Operating Instructions Models and Hydrostatic Test Pumps

HORIZONTAL BLADDER TANK

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Operating Instructions Models and Hydrostatic Test Pumps

OWNER S MANUAL SUCTION GUN SG-300

PXRF- Tracer Helium Flow Control System

OPERATING MANUAL LO-CROSS-FLOW CF M

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

STREAMLINE SHOP SERIES MODEL OPERATION & PARTS MANUAL

Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS

Bermad Pressure Reducing. Model: 42T

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

OPERATION MANUAL NTF-15

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

INSTALLATION and OPERATION INSTRUCTIONS

OPERATION MANUAL NTF-60 Plus

Installation Manual. Model # SF-3W 9/16/03 REV 1. Arch Chemicals, Inc Lower River Road. P.O. Box 800 Charleston, TN PULSAR

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

SINORIX Valve Reconditioning

LNG Regulator Test Kit

D05 Pressure Regulating Valves

SM Models Manual Control

Geotech 1.66 Reclaimer Installation and Operation Manual

DS05C,D,G Dial Set Pressure Regulating Valves

Operating Instructions Models and Hydrostatic Test Pumps

Air Operated Hydraulic Pumping Systems to 50,000 psi

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

ALF400 to 900, ALT-5/-9

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

CART FOR CENTURION 1500+

Geotech 3.5 Auto-Reclaimer

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

SM Models Manual Control

2.5 & 5.0 GALLON PRESSURE TANKS

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Lesson 6: Flow Control Valves

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

VACUUM REGULATORS CONTENTS

49004 Relief Pressure Check Kit for H8508 Series and HW1 Series Impact Wrenches

User s Guide. CO2 Controller for miniature incubators

Installation and Operations Manual Index

APPS-160 Gen 2 User Manual

UsER manual for Watersens ph -REDOX

Geotech 3.5 Reclaimer Installation and Operation Manual

1020 Industrial Drive, Orlinda, TN fax

RK LEL Sample Draw Aspirator Adapter Operator s Manual

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

Vacutrans Instructions

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

TurboDraft Fire Eductor

1 Exam Prep. Tabs and Highlights

Easy Nest Kits. Installation Suggestions

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

PRESSURE ADJUSTMENT Main pressure adjustment

Adjustable. Unloader Valve. O&M Manual. Part #

300 Held Drive Northampton Pa

MyControl Bathing System Signature Series

Installation of Your SprayMaster System

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

CSA Sample Draw Aspirator Adapter Operator s Manual

ABRASIVE REGULATOR II

OPERATING INSTRUCTIONS FOR THE MODEL 85B

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA

Discharge Relief Valve Operation & Maint.

ALF400 to 900, ALT-5/-9

Head to Head Demo Comparison Sheet

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Model 420-HY Pressure Regulating Hydrant Valve

Installation Instructions

VOLUMATIC WATER REGULATOR

ABRASIVE REGULATOR II

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

1020 Industrial Drive, Orlinda, TN fax

Axial Compression Packing Method

Rev. B Sept 06. VD510 INSTRUCTION MANUAL Part # DISPENSING VALVE MODEL VD510 INSTRUCTION MANUAL

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Transcription:

Manual Thank you for your purchase of the Transmate DeChlorinator. Please read and understand this short operation manual. Our goal is to serve you, our customer. If you have any questions or improvement suggestions please call us at -800-46-94. TABLE OF CONTENTS Solution Mixing...pg. Components...pg. Set-Up...pg. 4 Operation...pg. 5 Toubleshooting...pg. 6 Romac Industries, Inc. 99 0th Avenue SE Suite 00 Bothell, WA 980 800 46 94 45 95 600 Fax 45 95 60 www.romacindustries.com Operations Manual 08/0/08 Rev.

Vita-D-Chlor FEED SOLUTION MIXING AND FEED SOLUTION VALVE SETTING CHARTS This chart is good for water flow between 75-900 gpm Solution Mixing If... Then add... Set Control Valve on... Cl.(ppm, mg/l) Vita-D-Chlor cups for maximum Cl. value per 5 gal water 0 -.5 /4 cup.5 - / cup -.5 / cup.5-0 5 cups 0-0 5 cups 0-50 5 cups 50-50 5 cups Full open 50-00 4 cups Full open If you Turn control valve toward 0 You will Decrease the flow of feed solution And Increase the amount of time between solution batch mixing. Keep in mind You might not be adding enough feed solution to dechlorinate the water. Turn control valve toward full open Increase the flow of feed solution Decrease the amount of time between solution batch mixing. You might be using too much V-D-C mix and overdosing the discharge water. Increase the V-D-C mix amount Be able to decrease the feed solution flow Increase the amount of time between solution batch mixing. More V-D-C will be used and less time spent making solution batches. Decrease the V-D-C mix amount Have to increase the feed solution flow Decrease the amount of time between solution batch mixing. Less V-D-C used. More time spent making solution batches. FEED SOLUTION CONSUMPTION CHART Consumption in gallons per (how many minutes to empty a 5 gallon bucket) hour FLOW RATE in gallons per minute (GPM) Needle Valve Setting 50-00 GPM 00-00 GPM 00-400 GPM 400-600 GPM 600+ GPM FULL OPEN gph (4 min) 45 gph (7min) 64 gph (5 min) 90 gph ( min) 0 gph ( min) turns 7 gph (8 min) 4 gph (9 min) 48 gph (6 min) 68 gph (4 min) 8 gph (4 min) turns 6 gph (55 min) gph (7 min) 6 gph (9 min) gph ( min) 8 gph ( min) turn 4 gph (.5 hour) 7 gph (44 min) 0 gph ( min) 4 gph ( min) 7 gph (8 min) NOTE: Mixed solution cannot be stored overnight. It will decrease in potency and will not dechlorinate.

Components HANDLE HYDRANT ADAPTER - Threads onto the outlet of a fire hydrant to connect to the. FEMALE CAM LOCK FITTING - Used to connect to hydrant adapter. VACUUM GAUGE - Displays amount of vacuum created by water flow. Chlorinated Water In MAKE-UP WATER PORT - Solution make-up and untreated sampling water can flow out from here. FEED SOLUTION PORT - The dechlorinating solution is fed into this port. Flow range from 0-0gph. FEED SOLUTION CONTROL VALVE - This valve enables you to control the flow of the feed solution. GAS INJECTION PORT - This port is used to introduce gas into the flow stream. Dechlorinated Water Out MALE CAM LOCK FITTING - Quick fitting for connecting diffuser or exhaust hose.

Set-Up Connect the hydrant adapter, control valve, or extension hose directly to the hydrant. Thread the hydrant adapter onto the end of the control valve or extension hose if used. This step is done regardless of which set-up is used. NOTE: When using at very high flows, be sure to place pin in hole (shown below) to prevent the camlock from blowing off. CONFIGURATION # Extension hose connected to the hydrant with the on the ground and a diffuser connected to outlet. Connect female end of extension hose to hydrant or hydrant adapter. In this case the hydrant adapter is connected to the end of the extension hose. Connect female end of to male end of extension hose. Connect diffuser to male end of. CONFIGURATION # connected to a hydrant, and a diffuser connected to the outlet. Connect female end of to male end of hydrant adapter. Connect diffuser to male end of. 4

Set-Up CONFIGURATION # This configuration is used when you wish to use the unit between hoses leading to the hydrant adapter and diffuser. NOTE: Keep in mind the extension hose needs to be extended straight out with no kinks or bends. 4 Connect female end of the extension hose to hydrant adapter. Connect female end of to male end of extension hose. Connect female end of exhaust hose to male end of. Connect female end of diffuser to male end of exhaust hose. 4 NOTE: NO Kinks NO Bends ID minimum 0 ft. long maximum CONFIGURATION #4 If you want to connect the to a fire hydrant, using 0 feet of ID exhaust hose connected to the outlet. Follow these steps. NOTE: It is NOT recommended that the be connected directly to a hydrant with an exhaust hose connected to the outlet for use under 00 gpm. Connect to male end of hydrant adapter. Connect exhaust extension hose to male end of. This hose needs to be ID, and no longer than 0 ft. Connect diffuser to male end of exhaust hose. NOTE: NO Kinks NO Bends ID minimum 0 ft. long maximum 5

Operation Once you have completedyour set-up, the last steps are simple. This section of the manual deals with your s gauges, valves and hoses. It will outline and explain the flow direction, vacuum gauge and feed solution valve. The flow direction for dechlorinating is clearly marked on the top of your. Feed solution flow begins as needle starts moving Vacuum = Suction Suction = Suction Flow Counter clockwise rotation opens valve. Note color coding under valve handle: Color under valve handle denotes how open the valve is. RED = one turn BLUE = two turns ORANGE = three turns GREEN = full open To install tubes on the Make Up Water Port and the Feed Soution Ports, just push tube in. Removal is just as easy. To remove tubes, push in on outside collar while pulling away from unit on tube. Be sure not to force or overpull on the fittings. Connect the sampling tube to MAKE-UP WATER PORT Connect the feed solution tube to the FEED SOLUTION PORT. Connect the opposite end of the feed solution hose into the solution control valve located at the bottom of the bucket. 6

Operation Now that you have the feed tubes connected properly you re ready to start the flow of water. Begin the flow of water Control valve will fine-tune the flow of the feed solution The feed solution flow can be fine-tuned with the control valve. This allows just enough dechlorinating solution to be fed to the water flow and extends the time between making up more batches of feed solution. NOTE: Frequently check chlorine content of the discharge water and adjust the feed solution as needed. 7

Troubleshooting Problem not producing enough suction Possible Solutions Open up feed solution valve. Rotate valve in counterclockwise direction to open. Increase water flow rate. Check for blockage. Elevate bucket above. This will create a siphon. You might have too much exhaust hose length, too small an ID on your exhaust hose, or too much restriction on your diffuser. Shorten the exhaust hose length, and increase the exhaust hose ID. Make-up/Sampling water not producing enough water flow Increase the amount of water flow, by opening hydrant more Outlet water not dechlorinated. Youʼre at zero residual Cl, but your suspect youʼre using too much dechlorinating agent Increase the amount of dechlorinating reagent by scooping more into the feed solution mix. Slowly rotate the needle valve in the clockwise direction until you see just a trace of Cl., then rotate back half a turn. Check to make sure your residual is at zero. 8