RAILROAD COMMISSION OF TEXAS 1701 N. Congress P.O. Box 12967 Austin, Texas 78701-2967 Status: Form W-2 OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG Date: Tracking.: Approved 03/11/2015 122002 OPERATOR INFORMATION Operator Name: FORGE ENERGY, LLC Operator.: 276868 Operator Address: 10999 IH 10 WEST SUITE 900 SAN ANTONIO, TX 78230-0000 API.: 42-003-46173 Well.: 1W Lease Name: UL 10 HARMON RRC Lease.: 45845 Location: Section: 27, Block: 10, Survey: UL, Abstract: U311 WELL INFORMATION County: ANDREWS RRC District.: 08 Field Name: Field.: FUHRMAN-MASCHO 33176001 Latitude: 32.08281 This well is located 14 miles in a SW direction from ANDREWS, which is the nearest town in the county. Longitude: -102.40353 Purpose of filing: Type of completion: Type of Permit Permit to Drill, Plug Back, or Deepen Rule 37 Exception Fluid Injection Permit O&G Waste Disposal Permit Other: Spud date: 08/14/2014 FILING INFORMATION Date 05/30/2014 Permit. 783102 COMPLETION INFORMATION Date of first production after rig released: Date plug back, deepening, recompletion, or Date plug back, deepening, recompletion, or drilling operation commenced: 08/14/2014 drilling operation ended: 08/24/2014 Number of producing wells on this lease in this field (reservoir) including this well: Total number of acres in lease: Total depth TVD (ft.): Plug back depth TVD (ft.): Was directional survey made other than inclination (Form W-12)? Yes Recompletion or reclass? Well Record Only New Well Well Type: Active UIC Completion or Recompletion Date: 08/24/2014 5800 4892 330.30 Type(s) of electric or other log(s) run: Electric Log Other Description: 3 Gamma Ray (MWD) 11/04/2014 Distance to nearest well in lease & reservoir (ft.): 1515.0 Elevation (ft.): Total depth MD (ft.): Plug back depth MD (ft.): Rotation time within surface casing (hours): Is Cementing Affidavit (Form W-15) attached? Multiple completion? 3203 GR F-19920 Location of well, relative to nearest lease boundaries Off Lease : of lease on which this well is located: 2640.0 Feet from the rth Line and 838.0 Feet from the West Line of the UL 10 HARMON Lease. 08/24/2014 194.0 W2: N/A FORMER FIELD (WITH RESERVOIR) & GAS ID OR OIL LEASE NO. Field & Reservoir Gas ID or Oil Lease. Well. Prior Service Type Page 1 of 4
PACKET: N/A FOR NEW DRILL OR RE-ENTRY, SURFACE CASING DEPTH DETERMINED BY: GAU Groundwater Protection Determination SWR 13 Exception Date of test: Number of hours tested: Was swab used during this test? Oil (BBLS): Gas - Oil Ratio: Water (BBLS): Oil (BBLS): Oil Gravity - API - 60.: Water (BBLS): Row Type of Casing 0 Depth (ft.): Depth (ft.): 1650.0 Date: 03/31/2014 INITIAL POTENTIAL TEST DATA FOR NEW COMPLETION OR RECOMPLETION Production method: 24 Casing Size (in.) Hole Size (in.) Choke size: Oil produced prior to test: PRODUCTION DURING TEST PERIOD: Gas (MCF): Setting Depth (ft.) Flowing Tubing Pressure: CALCULATED 24-HOUR RATE Multi - Stage Tool Depth (ft.) Gas (MCF): Casing Pressure: CASING RECORD Multi - Stage Shoe Depth (ft.) Cement Class 1 Surface 9 5/8 12 1/4 1851 ECONOCE M 2 Conventional Production 7 8 3/4 4892 INTERFILL C Cement Amount (sacks) Slurry Volume (cu. ft.) Top of Cement (ft.) TOC Determined By 780 1374.0 SURF Circulated to Surface ACE 520 1218.0 SURF Circulated to Surface ACE LINER RECORD Row Liner Size (in.) Hole Size (in.) Liner Top (ft.) Liner Bottom (ft.) Cement Class Cement Amount (sacks) Slurry Volume (cu. ft.) Top of Cement (ft.) TOC Determined By N/A TUBING RECORD Row Size (in.) Depth Size (ft.) Packer Depth (ft.)/type 1 2 7/8 4850 4850 / J-55 PRODUCING/INJECTION/DISPOSAL INTERVAL Row Open hole? From (ft.) To (ft.) 1 L1 4892 5796.0 ACID, FRACTURE, CEMENT SQUEEZE, CAST IRON BRIDGE PLUG, RETAINER, ETC. Was hydraulic fracturing treatment performed? Is well equipped with a downhole actuation sleeve? Production casing test pressure (PSIG) prior to hydraulic fracturing treatment: Has the hydraulic fracturing fluid disclosure been reported to FracFocus disclosure registry (SWR29)? If yes, actuation pressure (PSIG): Actual maximum pressure (PSIG) during hydraulic fracturing: Row Type of Operation Amount and Kind of Material Used Depth Interval (ft.) 1 Acid 7500 GAL 10% FE ACID 4892 5796 Page 2 of 4
FORMATION RECORD Is formation Formations Encountered Depth TVD (ft.) Depth MD (ft.) isolated? YATES Yes 2926.0 Yes SEVEN RIVERS Yes 3150.0 Yes QUEEN Yes 3480.0 Yes GRAYBURG Yes 4180.0 Yes Remarks SAN ANDRES - CO2 FLOOD, HIGH Yes 4420.0 Yes FLOWS, H2S, CORROSIVE GLORIETA Yes 5604.0 TARGET HOLT NO DATA TUBB CLEARFORK PERMIAN DETRITAL LEON WICHITA ALBANY SPRABERRY DEAN WOLFCAMP CANYON PENNSYLVANIAN MCKEE STRAWN FUSSELMAN DEVONIAN SILURIAN ELLENBURGER Do the producing interval of this well produce H2S with a concentration in excess of 100 ppm (SWR 36)? Is the completion being downhole commingled (SWR 10)? REMARKS Page 3 of 4
PUBLIC COMMENTS: RRC REMARKS CASING RECORD : TUBING RECORD: PRODUCING/INJECTION/DISPOSAL INTERVAL : ACID, FRACTURE, CEMENT SQUEEZE, CAST IRON BRIDGE PLUG, RETAINER, ETC. : POTENTIAL TEST DATA: Printed Name: Telephone.: OPERATOR'S CERTIFICATION Shannon Harman Title: (210) 478-5960 Date Certified: 03/10/2015 Page 4 of 4
RAILROAD COMMISSION OF TEXAS Oil and Gas Division PO Box 12967 Austin TX 78711-2967 www.rrc.texas.gov CERTIFICATE OF COMPLIANCE AND TRANSPORTATION AUTHORITY This facsimile P-4 was generated electronically from data submitted to the RRC. Tracking.: 122002 A certification of the automated data is available in the RRC's Austin office. 1. Field name exactly as shown on proration schedule 2. Lease name as shown on proration schedule FUHRMAN-MASCHO UL 10 HARMON 3. Current operator name exactly as shown on P-5 Organization Report 4. Operator P-5 no. 5. Oil Lse/Gas ID no 6. County 7. RRC district FORGE ENERGY, LLC 276868 45845 ANDREWS 08 8. Operator address including city, state, and zip code 9. Well no(s) (see instruction E) 10999 IH 10 WEST SUITE 900 1W SAN ANTONIO, TX 78230 10. Classification 11. Effective Date Oil Gas X Other (see instruction A) 08/24/2014 12. Purpose of Filing. (Complete section a or b below.) (See instructions B and G) a. Change of: operator oil or condensate gatherer gas gatherer gas purchaser gas purchaser system code field name from lease name from OR b. New RRC Number for: oil lease gas well Due to: new completion or recompletion reclass oil to gas X other well (specify) consolidation, unitization, or subdivision (oil lease only) 13. Authorized GAS WELL GAS or CASINGHEAD GAS Gatherer(s) and/or Purchaser(s). (See instruction G). Gatherer Purchaser Name of GAS WELL GAS or CASINGHEAD GAS Gatherer(s) or Purchaser(s) As Indicated in Columns to the Left (Attach an additional sheet in same format if more space is needed) Purchaser0s RRC Assigned System Code P-4 reclass gas to oil Percent of Take Full-well stream 14. Authorized OIL or CONDENSATE Gatherer(s). (See instruction G). N/A Name of OIL or CONDENSATE Gatherer(s) - List Highest Volume Gatherer First (Attach an additional sheet in same format if more space is needed) Percent of Take RRC USE ONLY: Reviewer0s initials: RRC Staff Approval date: 03/11/2015 15. PREVIOUS OPERATOR CERTIFICATION FOR CHANGE OF OPERATOR P-4 FILING. Being the PREVIOUS OPERATOR, I certify that operating responsibility for the well(s) designated in this filing, located on the subject lease has been transferred in its entirety to the above named Current Operator. I understand, as Previous Operator, that designation of the above named operator as Current Operator is not effective until this certificate is approved by the Commission. Name of Previous Operator Name (print) Signature Authorized Employee of previous operator Authorized agent of previous operator (see instruction G) Title Date Phone with area code 16. CURRENT OPERATOR CERTIFICATION. By signing this certificate as the Current Operator, I certify that all statements on this form are true and correct and I acknowledge responsibility for the regulatory compliance of the subject lease including plugging of well(s) pursuant to Rule 14. I further acknowledge that I assume responsibility for the physical operation, control, and proper plugging of each well designated in this filing. I also acknowledge that I will remain designated as the Current Operator until a new certificate designating a new Current Operator is approved by the Commission. FORGE ENERGY, LLC Shannon Harman Name (print) Signature Authorized Employee X Authorized agent of current Title of current operator operator (see instruction G) sharman@forgenergy.com 12/02/2014 (210) 478-5960 E-mail Address (optional) Date Phone with area code
March 31, 2014 16581 BRYCE HARLOW ***** EXPEDITED APPLICATION ***** SC_276868_00300000_000000_16581.pdf 00300000 000000 --Measured-- 838 ft FWL 102.67604 FORGE ENERGY LLC 10999 IH10W 2640 ft FNL 32.14105 STE 900 SAN ANTONIO TX 78230 MRL:SECTION 27 P-5# 276868 ANDREWS UL 10 HARMON #1W H1 SUR-UL,BLK-10,SEC-27,--[TD=5800],[RRC 8], The interval from the land surface to a depth of 250 feet and the ZONE from 1050 feet to 1600 feet must be protected. The BASE OF UNDERGROUND SOURCES OF DRINKING WATER (USDW) is estimated to occur at a depth of 1650 feet at the site of the referenced well. George Dunfield, P.G. 3/31/2014