ThermaSkirt A N E C O R E V O L U T I O N I N R O O M H E A T I N G

Similar documents
M03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

System Pressure Manager Standard & System Pressure Manager Plus

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

STAP. Differential pressure controller DN 15-50

Electronic Single and Twin Pump System Pressure Managers

ambiente Installation Guide AmbiPlate more than underfloor Customer: Project: Project Reference: Date:

Datasheet liniled Handrail 48.3 V1017 IK10 IP68. F RoHS IP40/IP65 FROST CLEANING AGENTS RESISTANT UV RESISTANT

Deluge Optimo Shower valve and kit 10032CP

Twin & Triple Control Concealed Thermostatic Shower Valve

OWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01

HORNE T109A/306A/307A THERMOSTATIC SHOWER VALVE FOR SURFACE MOUNTING WITH TIMED FLOW CONTROL INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

TECHNICAL DATA. Trimpac 244a. September 16, 2013

AREA VALVE SERVICE UNITS

Datasheet liniled Handrail 42.4 V1017 IK10. F RoHS FROST CLEANING AGENTS RESISTANT UV RESISTANT

Expansion Vessels for Potable Installations

Automatic balancing valves

SEries 29 Hydrant valves installation, operation & maintenance manual

STAP. Differential pressure controller DN

Series IRV1000/2000/3000

Bar valve with fixed shower head Installation guide

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

SIMPLAIR PIPING TOOL. JXT Company

776 Cryogenic Safety Valve

Self-help Temperature Adjustment

ambiente Installation Guide AmbiScreedboard system more than underfloor Customer: Project: Project Reference: Date:

OUS31. Technical Information

URINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

These instructions are to be left with the user

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

756 Safety Relief Valves

Sealed Systems Altecnic Ltd - Caleffi group. Sealed Systems. Heating vessel sizing guide

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Overhead Irrigation Installation Guide DOM Copyright First Tunnels Ltd 2012.

CalCheck. Instrument User Manual V1.8

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

Mainsboost Installation, Operation & Maintenance Instructions

Bourdon tube pressure gauges for chemical applications EN 837-1

CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division

F13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS

PC3_ and PC4_ Pipeline Connectors

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

Internal Sealing of Masts

Horne Engineering Ltd

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual STOP!

Mainsflush Troubleshooting Guide

36H SERIES Combination Gas Valve

UltRo Dual Flow Reverse Osmosis Water System

Aquor House Hydrant V2

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

TECHNICAL ACCESSORIES

TWO POST RAM PACKAGE 55 GALLON

USG Ceiling Solutions. LOGIX Integrated Ceiling Systems INSTALLATION GUIDE

Sunrise Fountain Water Wonders Assembly & Mounting Instructions

OCEAN - Wellness Line

STA-F Description. STA-F Prefab insulation Measuring nipples

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

PT 11 trouble-shooting and maintenance.

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

USER INSTRUCTIONS. NAF Duball DL Ball Valves. Installation Operation Maintenance. Experience In Motion. flowserve.com

Impeller Replacement -

Installation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

Operating Instructions

INDUSTRIAL TRANSFER PUMPS

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Rotary Abreast Automatic Teat Sprayer User Manual. Technical Manual Revision 0.01

INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE

Ligature Resistant Head

Pressure Dump Valve Service Kit for Series 2300 Units

ambiente Installation Guide AmbiClip Systems more than underfloor Customer: Project: Project Reference: Date:

PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

DS MB, MBF THREE PORT VALVES

Proportional Throttle Cartridges, Size 16

Installation, commissioning and servicing instructions

Temperature Controllers

Pressure and Flow Control Valves DBGM, German and European Patents

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

Differential pressure gauge For the process industry Model , all-metal media chamber

APPROVED FOR USE IN SOUTH AFRICA STAINLESS STEEL STOVE

Ball Valves for Heating and District Heating. Date 1

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Installation Instructions

EnerVal. Technical data litre storage capacity. Buffer storage vessels

TECHNICAL DATA. Q = C v P S

NEW TYPE M PRESSURE RELIEF DEVICE

These instructions are to be left with the user

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

water purification cylinders & accessories

Transcription:

DOUBLE TRV TEMPLATE (Sheet 1 of 2) Through floor pipework (Left and right feed) 0 20 40 mm 1 Relieve plaster/ surface finish to a depth of in this shaded area to allow for Tectite fittings 4 Relieve plaster/surface finish to a depth of 2 in this dark shaded area to allow feed pipe to go behind Tectite fitting 1 60mm 9 Cut/fold along here for Urban LT template Cut/fold along here for Regency OG template (See sheet 2 for location) TM I N S TA L L AT I O N Page 1 1. P O S I T I O N F E E D P I P E S ISSUE 14 / November 2009 (Download further copies at www.discreteheat.co.uk/technical.html) ThermaSkirt A N E C O R E V O L U T I O N I N R O O M H E A T I N G These instructions are intended as a guide only. Your installation & design may vary - if in doubt ask for help. DiscreteHeat Co. Ltd. accept no liability for any errors or omissions. If you have any tips or suggestions e-mail them to: toptips@discreteheat.co.uk TOOLS YOU WILL NEED: A suitable metal cutting saw, preferably a chop saw (only if cutting lengths on site) / A DiscreteHeat rotary de-burring tool / An accurate quality tape measure (Stanley, DeWalt etc.) / String line and chalk or laser level / A Stanley knife and/or plasterboard saw / Power drill with hammer action / Power driver / Size 10 screws (50-) / Plastic or timber faced mallet / Rawlplugs and\or plasterboard fixings / Pipe cutting tool (10mm/1/16mm) / Various push fit connectors / Your plan and cutting list (if purchased as a room kit). ALL EXAMPLES SHOWN ARE CLOCKWISE S. THE SAME DIMENSIONS AND SPACINGS APPLY TO ANTI-CLOCKWISE S. Remember to allow for carpet or tiles if NOT Finished Floor Level REGENCY OG (8in / 200mm) URBAN LT (6in / 150mm) DECO PR (5in / 12) 4 1 Feed and Return pipes tight to wall 12 9 3 6 CLOCKWISE SHOWN PIPE FITTINGS NEED TO BE SET INTO THE SINGLE TRV Relieve plasterwork x to a depth of BI-DIRECTIONAL TRV Relieve plasterwork 150mm x to a depth of 150mm Feed 1 (16mm to order) Return 1 (16mm to order) FOR TEMPLATES VISIT www.discreteheat.co.uk/technical.html

TM Page 2 2. CUTTING SKIRTING TO LENGTH (when not supplied pre-cut) RF L 1 50mm L 9 = (L 9-150mm) = (L 1-150mm) = (L 2-60mm) = (L 3 -) L 2 Archway, patio, door obstruction, etc. (Threshold Kit) CLOCKWISE SYSTEM SHOWN = (L 4-0~) L 4 L 3 L 5 = (L 5 -) L 8 = (L 8-1) = (L 7-60mm) = (L 6-60mm) L 6 24 TPI minimum L 7 (5") (1 1 / 4 ") 0~ (0.0") 50mm (2") 50mm (2") (4") 50mm (2") 20mm ( 3 / 4 ") Deburring tool (Part No. STOOL) Bell Mouth deburr DEBURR Keep parallel x10 Remove all chaff and debris

TM Page 3 3. MOUNTING CHANNEL - LT AND OG PROFILE ONLY? Make sure you allow for uneven/unlevel floors. Bottom cover should be trimmed first. Pencil Line C C L L STRING LINE & CHALK Push in 60mm Chalk Line 8 Chalk Line 90 Click down URBAN LT REGENCY OG URBAN LT & REGENCY OG ONLY 150mm 600 ~ 1,000mm ± Insulating foil, if required (Part No. INSRL LT or INSRL OG) (older, solid walls without cavity) DECO PR Minimum active length = 50mm (2") Mounting brackets can be cut for smaller sections

= = TM Page 4 4. SEQUENCE 12 9 3 6 CLOCKWISE SHOWN View on back of TRV showing fixings DO NOT OVERTIGHTEN Feed Return Internal Corner 40mm External Corner 20mm 20mm CLICK 30 ~ 40mm ENSURE BOTH SIDES ARE LEVEL WITH EACH OTHER PUSH CLICK, CLICK, CLICK 20mm max. STAINLESS STEEL C/SUNK FIXING SCREW RECOMMENDED

TM Page 5 5. CORNERS AND COVERS Trim 1 Spraying channel with water or furniture polish can help fitting 2 ENSURE BOTH SIDES ARE LEVEL WITH EACH OTHER Peel off Super Velcro backing Cover can be warmed on the back to adjust the angle and ease fitting (Overheating will cause damage) 1 Pz x 2 Check back of cover is clean and free from grease Pz1 Position holes in knob as shown to access 2 fixing screws for TRV controls 2 6. FINAL CHECKS 1 ~ 2 bar 2 1 Clockwise Installation OFF AIR OFF OFF TRV Unit Anti-clockwise Installation Return Manifold A pressure test of the system before connecting to the central heating system is recommended. (See part no. TTEST) TECHNICAL SPECIFICATION Material Output (per M @ dt50 C) Feed & Return Weight Capacity Corrosion Min. Flow Surface Complies Recommended BTU / W Pipe Kg per m Litres per m Resistance Rate Finish with Max. Operating Temp. Unique Polymer & LT > 500BTU / 150W 1 1.4kg LT 0.5 l/m Excellent 10 c.c. per sec Epoxy Powder BS-EN 80 C Aluminium Alloy OG > 700BTU / 210W 16mm to order 1.7kg OG See Section 7 0.6 litre/min to BS-EN 12206-1 442 PR > 450BTU / 135W 1.2kg PR Running your system

TM Page 6 7. RUNNING YOUR SYSTEM Run the system at fully open, maximum temperature for 1 hour, to expel any air in the system. Release any air that may be trapped at appropriate radiator bleed points and return manifold bleed point. Turn off TRV/flow manifold and allow to cool. Set to desired room setting and run normally. NOTE: DiscreteHeat recommend flushing the system with ThermaSkirt Cleanser TS3 or alternatively Scalemaster SM3 (check dosage carefully) and running with ThermaSkirt corrosion inhibitor TS5 or alternatively Scalemaster SM1 (check dosage carefully) to ensure maximum longevity and reliability. Hard water areas may require additional precautions. Chemically softened water must NOT be used. This is a standard precaution for ALL wet heating systems. Contact DiscreteHeat for specific application advice. 8. TROUBLE SHOOTING PROBLEM CAUSE SOLUTION Leak at joint. Faulty / incorrect installation Drain and replace fitting or O ring from spares kit. ThermaSkirt not hot. Check boiler. Is heating ON and pressure OK? Lockshield valve closed. Open Lockshield valve ( ). TRV valve closed / off. Open TRV valve ( ). Air trapped in pipework. See 9 below. Water from Manifold not closed fully. Turn to OFF position. Return Manifold. 9. BLEEDING YOUR SYSTEM As ThermaSkirt acts like a pipe, in normal operation air does not get trapped. However, on existing systems, to which ThermaSkirt is added, air may get trapped in the existing pipework to and from the skirting. Follow these simple steps if you discover cold sections of the ThermaSkirt which do not heat up. CLOSE 1. Existing System with Conventional Radiators. Turn off all radiators and ThermaSkirt thermostatic and lockshield valves. Make sure your system is fully pressurised and the pump is set to max. Run the system for a few minutes, and, starting from the lowest point in the house, open each radiator/thermaskirt system, one at a time. Run for a further 2 minutes (approx), close again and move to the next ThermaSkirt or radiator, moving upwards in the house. Any air will be expelled through the boiler or trapped in a conventional radiator. Bleed the radiator as normal. Trapped air expelled through boiler Existing System with Conventional Radiators TRV Unit CLOSE 2. New Installation with ThermaSkirt Only. On installation, in a convenient place at the highest point of the system, T off into a vertical leg 600mm high and install an automatic/manual air vent. Following the procedure above, close and open each ThermaSkirt system in turn. Any air forced round the system will be expelled through the boiler or through the air vent. Air can also be bled from the bleed screw on top of the return manifold (A). 600mm (min) Trapped air expelled through boiler New Installation with ThermaSkirt Only A

LH END LH END clockwise installation Cut along dotted line SINGLE TRV TEMPLATE) (Through floor pipework) Fax: 01942 892836 e-mail: info@discreteheat.co.uk 0 20 40 web: www.discreteheat.co.uk mm 12 9 3 RH END anti-clockwise installation 9 Fold along here for Deco PR template Fold along here for Urban LT template Relieve plaster/ surface finish to a depth of in this hatched area to allow for Tectite fittings (PR) 4 (LT) (OG) (PR) (LT) touching wall surface 1 (OG) Fold along here for Regency OG template touching wall surface Plan view for drilling feed and return pipe holes in floor DOUBLE TRV TEMPLATE (Sheet 1 of 2) Through floor pipework (Left and right feed) 0 20 40 mm 1 Relieve plaster/ surface finish to a depth of in this shaded area to allow for Tectite fittings 4 Relieve plaster/surface finish to a depth of 2 in this dark shaded area to allow feed pipe to go behind Tectite 9 1 60mm Cut/fold along here for Urban LT template Cut/fold along here for Regency OG template (See sheet 2 for location) STICK TO TO USE fitting Cut/fold along here (Place on end of wall or doorway architrave) Cut/fold along here (Place on end of wall or doorway architrave) 12 9 3 6 6

80mm 0 20 40 mm (Through floor pipework) THRESHOLD KIT PIPE TEMPLATE 80mm 50mm LH END 50mm RH END (PR) 80mm 80mm Fold along here for Regency OG template touching wall surface Plan view for drilling feed and return pipe holes in floor touching wall surface 32mm 32mm Cut/fold along here (Place on end of wall or doorway) Cut/fold along here (Place on end of wall or doorway) LH and RH installation Relieve plaster/surface finish to a depth of in this hatched area to allow for Tectite fittings Fax: 01942 892836 e-mail: info@discreteheat.co.uk web: www.discreteheat.co.uk Fold along here for Deco PR template Fold along here for Urban LT template 1 (OG) (OG) (LT) 4 (LT) (PR) DOUBLE TRV TEMPLATE (Sheet 1 of 2) Through floor pipework (Left and right feed) 0 20 40 mm 1 4 Relieve plaster/ surface finish to a depth of in this shaded area to allow for Tectite fittings Relieve plaster/surface finish to a depth of 2 in this dark shaded area to allow feed pipe to go behind Tectite fitting 9 1 60mm Cut/fold along here for Urban LT template Cut/fold along here for Regency OG template (See sheet 2 for location) STICK TO TO USE