G SPECIFICATION: TITLE: VOLUME: 4 REVISIONS:

Similar documents
G REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS, MICROTURBINES AND ASSOCIATED SYSTEM PROTECTIVE DEVICES

REQUIREMENTS FOR THE INSTALLATION OF GAS UTILIZATION EQUIPMENT THAT MIXES PRESSURIZED OXYGEN WITH NATURAL GAS

KC Series Gas Components and Supply Design Guide

GAS SUPPLY DESIGN GUIDE

GAS SUPPLY APPLICATION GUIDE

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

SPECIFICATIONS ATTENTION

G96 Series BASOTROL Dual Operator Valve

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S02

Piped Air SCBA Refilling System Standard

TECHNICAL DATA. than the water inlet pressure to the concentrate

Tightness control TC. Product brochure GB 3 Edition AGA

Manifolds & pressure reducing sets

HNP-021 Oil Purifier. Description. Specifications. Features. Contact Us:

INSTALLATION OPERATION MAINTENANCE

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Supplementary Operator s Manual 42/24-14 EN Rev. 3

G REQUIRMENTS FOR BRANCH LINES SUPPLYING MULTIPLE REGULATORS AND / OR METERS. 3 and Gas Blue Book

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Apollo Safety Features

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Aquavar SOLO 2 Frequently Asked Questions

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Spirax Compact FREME Flash Recovery Energy Management Equipment

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

MANUAL GAS MANIFOLDS

Propane Conversion Kit Instruction

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation Instructions

Propane Conversion Kit Instruction

OC Panel High Limit Aquastat Kit, Manual Reset p/n

Operator: Save these instructions for future use!

TotalPac X Single interlock Preaction system Electric release

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

G92 Series BASOTROL Automatic Pilot Gas Valve

C645A-E Pressure Switches

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Regulators/valves Compressed air regulators Without filter

AUTOMATIC GAS MANIFOLDS

Propane Conversion Kit Instruction

Automatic Valve Proving Control

Thank You for Attending Today s Webinar. Today s Featured Speaker

ASSE International Product (Seal) Listing Program

TECHNICAL DATA. Dry 132a. October 1, 2008

GM Series Dual-Block Multi-Function Gas Control Valves

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

EDUCATION DEPARTMENT ACCU-TEST

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

R I T. Title: Amray 1830 SEM Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 09/29/03 1 SCOPE 2 REFERENCE DOCUMENTS

Instruction Manual No. 742, 8/98

Constant Pressure Inlet (CCN) Operator Manual

Natural Gas to L.P. Gas Conversion Kit

North American Pressure Switches

MEMORIAL UNIVERSITY OF NEWFOUNDLAND Faculty of Engineering and Applied Science FLUID MECHANICS LABORATORY PIPE FRICTION

GM-7000 Series CE Approved Gas Control Valve

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

Section GAS CHLORINATION SYSTEM

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Ratio Regulator Zero Governor. FRG/6 Series

PRESSURE SWITCHES Bulletin 8757

TABLE OF CONTENT

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

SL G3. Warning

Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels

my SYSTEM A guide to common applications in water distribution systems

ACCESSORY KIT INSTALLATION MANUAL

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

36H SERIES Combination Gas Valve

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

SINGLE VALVE WITH LOW-FLOW BYPASS

UTAS EH&S INSTRUCTION No. 036 June 2012 Revision No. 3. Purging of Flammable Gas Equipment and/or Piping (Explosion Hazard)

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

FOAM TANK (1/2) DATA SHEET

Residential and Small Commercial

DANGER WARNING IMPORTANT

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

Laboratory Ventilation. Environmental, Health, and Safety

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

GAS DEHYDRATION SYSTEM

Inert Air (N2) Systems Manual

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

SPIROVENT VACUUM DEGASSERS

TECHNICAL DATA. Q = C v P S

TECHNICAL MANUAL CALIBRATION INSTRUCTIONS FUEL PRESSURIZING & DUMP VALVE TEST STAND 1TL

Dual Solenoid Gas Valve Installation

Transcription:

SPECIFICATION: G-2040-7 TITLE: REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS AND BACK PRESSURE/SUCTION PROTECTIVE DEVICES IN VOLUME: 4 REVISIONS: Totally re-written.

G-2040-7 Gas Operations Standards TITLE: REQUIREMENTS FOR THE INSTALLATION OF TABLE OF CONTENTS SECTION TITLE PAGE 1.0 SCOPE 2 2.0 GAS ORGANIZATIONS 2 3.0 RESPONSIBILITY 2 4.0 GAS BOOSTER INSTALLATIONS 2 5.0 PROTECTION FOR AIR OR OXYGEN 6 GAS MIXTURES AT OR ABOVE 6 WC 6.0 LPG AS A STANDBY SOURCE 6 7.0 REFERENCES 6 8.0 ATTACHMENTS 7 PREPARED BY: N. Inga APPROVED BY: DATE: VOLUME: 4 PAGE 1 OF 7 PAGES Anthony B. Codner Chief Gas Engineer 1/7/98

1.0 SCOPE This specification covers the installation of gas boosters and back pressure/suction protective devices on the customer s piping. 2.0 GAS ORGANIZATIONS APPLICABLE Westchester, Manhattan, and Bronx/Queens 3.0 RESPONSIBILITY 3.1 Energy Services in each Customer Service Organization shall indicate on the electronic Service Information Request (SIR) in CORS, each item of customer utilization equipment using oxygen, air, or other gas under pressure, a gas booster (to increase the pressure) or stand-by liquefied petroleum gas (LPG) as a substitute for the Company's gas. 3.2 Gas Engineering shall determine whether the service size is adequate and inform Energy Services via the CORS SIR. 3.3 It shall be the responsibility of the customer, or the customer s engineer or contractor to arrange for the booster manufacturer to prepare, for Con Edison s approval, a one-line drawing showing the gas booster with the required protective devices. 3.4 No gas service shall be supplied to a customer who has not installed the necessary safety devices required by this specification. 4.0 GAS BOOSTER INSTALLATIONS 4.1 Con Edison is required to supply a minimum pressure of 4 w.c. at the head of service. A hermetic gas booster with an explosion-proof motor, having the approval of a nationally recognized testing laboratory (i.e. UL or AGA), may be installed when supply gas pressure is not sufficient to supply new gas utilization equipment. 2

4.0 GAS BOOSTER INSTALLATIONS (Continued) 4.2 The gas booster shall be mounted and installed as per the manufacturer s specifications. 4.3 Protective Devices A) Check Valve A check valve shall be installed between the gas meter and the gas booster as shown in Drawing No. 311296. The check valve is required to prevent flow back through the gas meter and into the Con Edison gas distribution system. As stated in Specification G-8000, an Eclipse Series 1000 Disc Type Check Valve or the equivalent shall be used in all gas booster installations. The booster manufacturer shall specify the minimum distance between the check valve and the booster inlet. B) Pressure Switches 1) A low gas pressure switch shall be installed between the gas meter and the check valve. The switch shall be the mercoid type or the equivalent as stated in Specification G-8041, and shall be set to open at 3 w.c. to shut the booster off. The switch shall have a manual reset and must be vented to the outside. The pressure switch shall be located as close as possible to the gas service point of entry. Venting is not required if explosion-proof switches are used. 2) A second low gas pressure switch may be installed on the outlet pipe of the gas booster. This second switch is optional and is used to alarm personnel of a booster failure. 3

4.0 GAS BOOSTER INSTALLATIONS (Continued) 4.4 Branch Supply 4.5 Piping Branch supply to a load not requiring booster pressure shall be located on the upstream side of the check valve. Branch supply may be connected through the same meter or separate meter(s) depending on the service classifications involved. Fittings, elbows and valves shall be kept to a minimum in order to reduce pressure losses. Piping from the gas point of entry to the booster(s) shall be designed by the booster manufacturer or its authorized representative to allow a maximum pressure drop of 1 w.c. (excluding the gas meter). 4.6 By-Pass Some booster applications may require the installation of a by-pass. The decision of whether or not a by-pass is required shall be left up to the booster manufacturer or its authorized representative. 4.7 Re-circulation Loop and Heat Exchanger A re-circulation loop with a heat exchanger and associated sensors and controllers shall be installed when specified by the booster manufacturer or its authorized representative. In general, this arrangement will be called for to keep the booster motor cool under low flow conditions. 4

4.0 GAS BOOSTER INSTALLATIONS (Continued) 4.8 Submittal A) GAS BOOSTER DESIGN DATA SHEET The booster manufacturer or its authorized representative shall submit to Con Edison Energy Services a completed Gas Booster Data Sheet (Appendix A). B) DRAWING 4.9 Operational Tests The booster manufacturer or its authorized representative shall submit a job specific one-line drawing of the proposed booster installation to Con Edison Energy Services. The drawing shall indicate: the suggested piping design (by size and length) between the gas point of entry (P.O.E.) and the booster outlet; the location of all isolation valves, check valves, pressure switches, pressure gauges, boosters, and gas meters; by-pass piping, re-circulation loop, and heat exchanger if required. The customer s heating contractor/plumber shall conduct a series of operational tests of the boosters and the protective devices to insure proper working condition. Pressure test points must be installed near the low pressure cut-off switch and the booster inlet in order to allow for the performance of pressure checks called for herein. The tests shall be witnessed by the Company s Commercial Services Representative (CSR) and shall check for the following: 5

4.0 GAS BOOSTER INSTALLATIONS (Continued) A) Booster The gas pressure at the booster inlet is at least 3 w.c.; The booster supplies adequate gas at maximum load (boilers firing at rated load). B) Low Pressure Cut-Off Switch (Booster Inlet) C) Check Valve The switch cuts-off the booster when the pressure drops below 3 w.c. as verified by a manometer; The switch can be manually reset after pressure is restored to >3 w.c. The check valve is installed in the proper direction. 5.0 PROTECTION FOR AIR OR OXYGEN GAS MIXTURES AT OR ABOVE 6 WC Consult with Gas Engineering on installations where air, oxygen, or other gas mixtures are required. 6.0 LIQUIFIED PETROLEUM GAS AS A STANDBY SOURCE Consult with Gas Engineering on installations where liquified petroleum is required as a standby source. 7.0 REFERENCES Reference should be made to Purchase and Test Specifications G-8000 Purchase Specification for Gas Check Valves and G-8041 Gas Pressure Switches for Anti-Vacuum Protection. 6

8.0 ATTACHMENTS Appendix A: Drawing No. 311296: Gas Booster Data Sheet Typical Gas Booster Installation 7

Appendix A Gas Booster Data Sheet Project Address Load & Piping Information Total # of Boilers Total CFH (Min) (Max) Gas Service Diameter (From Con Ed Form 2-80) Gas Meter Size & Type (From Con Ed Form 2-80) Gas Pressure Available at Booster Inlet (4 W.C. @ Head of Service Minus Pressure Losses. Allow 0.5 W.C. For Pressure Drop Through Meter) Gas Pressure Required at Manifold Inlet Discharge Piping Diameter Total Equivalent Length of Discharge Gas Piping Including Fittings Total Discharge Piping Pressure Loss Booster Information Mfr Model Flow Capacity (CFH) Booster Inlet Size Outlet Size Booster Motor HP Voltage Ph Hz Booster Differential Pressure (W.C.) Total Discharge Pressure (W.C.) (Differential Pressure + 4 W.C.) Control Panel Model NEMA Check Valve Size Manifold Req d: No If Yes: # of Valves Heat Exch r Reqd: No If Yes: Piping Size Ck Valve Size ****************************************************************************** Submitted By Date Rev # Company Phone (Booster Mfgr or Authorized Representative) G-2040