Fuel Filters DN15 DN25. elektrogas.com DE

Similar documents
Gas Filters DN15 DN300. elektrogas.com EE151 06/13

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

VMR VMR-OTN VMR 6 bar

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300.

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

Slam Shut Valves SCN

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

Pressure reducing valves Index

Cellular Gas Filters DF 100. Product Information

Norval Pressure regulator

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

Dival 500 Pressure Regulators

Slam Shut Valves SBC 782

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

RTG 25. Introduction

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Seated valves VRB 3, VRG 3

Norval Pressure Regulators

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Aperval Pressure Regulators

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Pressure regulator FRS

Dival 600. Pressure Regulators

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

RR 16 Commercial & Industrial Regulator

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Gas Pressure Regulator HON 502

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

GA24 Technical Datasheet

Solenoid valves VZWF, force pilot operated

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

ASX 176 Axial Pressure regulator

RR 16 Commercial & Industrial Regulator

Pressure regulators. Introduction. TR Head. 3 ways body Dival

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Noth American 7347 High Pressure Gas Regulators

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Old documentation - Only for your information! Product is not available anymore!

Installation, commissioning and servicing instructions

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

Membrane dryers. Series airfit dry G1/2. with/without patented purge air regulation. Overview Description. Characteristics Dimensions

Glass tube flowmeters Series 2000

North American 7339 High Pressure Gas Regulators

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

GasMultiBloc Combined regulating and safety valve Infinitely variable air/gas ratio control mode MB-VEF B01

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Pressure Regulators. Aperflux 101

Pressure ranges and accuracy classes for outlet pressure and safety devices

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

NEW TYPE M PRESSURE RELIEF DEVICE

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

GM-7000 Series CE Approved Gas Control Valve

Pilot HON 630a, HON 640

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Safety Shut-off Valve SSV

GAS PRESSURE REGULATORS AND FILTERS.

Gas Pressure Regulator HON 300

Performance Literature for J48. Gas Pressure Regulators 2½ 6 Sizes. Catalogue

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

3-way control valves VK 3

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Gas Pressure Regulator HON 505

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

VRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Pressure regulator FRS

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Mechanical Pressure Measurement

Air preparation units

Performance Literature for 60DJ, 80DJ & 150DJ Gas Pressure Regulators ¼, ⅜ and ½ Sizes. Catalogue

Transcription:

FF Fuel Filters DN15 DN25 elektrogas.com DE180 0914

FF Fuel Filters Contents Description.. 2 Features.. 2 Functioning and application. 3 Accessories and optionals 4 Technical specifications 4 Gas flow chart (pressure drop) 6 Ordering information. 8 Standards and approvals. 9 Description The FF type is a filter for fuel pipelines with very high holding capacity of dust and impurities, suitable for the protections of devices installed downstream. Features The filters are made of aluminum alloy die-cast, with a range for inlet/outlet connections from DN15 up to DN 50. Suitable for fuel oil in liquid state or gaseous media. The incorporated filtering cartridge is a steel support frame covered with a double-layer high performance nonwoven made of polyolefine fibers, which satisfy the stringent requirements of Fire Class F1 according to DIN 53438 and are thus self-extinguishing. FFS1-FFS2 models are provided with a mesh filter cartridge. Considering the same connection, the FFS are smaller models of FF filters: the body is more compact with a reduced filtering surface. Optionally provided with pressure gauges for both inlet and outlet chamber (excluded FFS1- FFS2 models). All components are designed to withstand any mechanical, chemical and thermal condition occurring during typical service. Effective impregnation and surface treatments have been used to improve mechanical sturdiness, sealing and resistance to corrosion of the components. Filters are 100% tested by computerized testing machineries and are fully warranted. WARNING This appliance must be installed in compliance with the rules in force. 2-6

Functioning and application DELTAPUMPS Technical Sheet DE180 The FF type filter is designed for installation in fuel lines, to protect downstream fittings. The filtering cartridge made of nonwoven polypropylene fibers with a metal support frame, is suitable to retain dust and other impurities with size 30µm (50µm for mesh filter of FFS1- FFS2). When the dust storage capacity is exceeded or if there is an excessive pressure difference, the filter loses its protective function. In this case the filter element must be cleaned or replaced. The mesh filter cartridge of FFS1-FFS2 models is easy washable. Fig.1 WARNING Location and mode of installation must be in compliance with local rules in force. Accessories and optionals Inlet and outlet pressure chambers can be provided with pressure gauges, to connect a differential pressure switch to monitor the pressure difference. On request a test point fitting can be provided (mounting in charge of the user). Technical specifications Tab. 1 Connections Gas threaded ISO 7-1 from Rp1/2 to Rp2 Max. operating pressure Ambient temperature Flow capacity Pore width of filter element 2 bar (200 kpa) -15 C / +80 C see charts 50 µm (mesh filter cartridge FFS1, FFS2) 30 µm (double-layer polypropylene cartridge) Filtration class G4 according to EN 779 Pressure gauges (when provided) Inlet and outlet chambers G1/8 onto threaded models (except FFS1-FFS2) Installation Materials in contact with media Into horizontal and vertical pipeline Aluminium alloy Plated steel Polypropylene fibers Nitrile rubber (NBR) Fluoroelastomer (FPM) (optional) 3-6

Tab. 2 Model Connection Flow factor Kvs (*) [m 3 /h] (*) in the hypothesis of working with gaseous media Overall dimensions [mm] A B C Int h Weight FFS1 Rp 1/2 6,8 60 70 60 0,24 17 FF1 Rp 1/2 6,8 88 96 84 0,39 55 FFS2 Rp 3/4 11 60 70 60 0,22 17 FF2 Rp 3/4 11 88 96 84 0,38 55 FFS3 Rp 1 14 88 96 84 0,36 55 [Kg] Filtering area [cm 2 ] FF3 Rp 1 19 134 140 91 0,97 145 FF35 Rp 11/4 24 134 140 91 0,91 145 FFS4 Rp 11/2 28 134 140 91 0,85 145 FF4 Rp 11/2 40 182 208 128 2,2 330 FF6 Rp 2 56 182 208 128 2,0 330 Flow chart for gaseous media (Pressure drop) Fig.2 4-6

Formula of conversion from air to other gas media Tab. 3 V = k GAS V AIR 15 C, 1013 mbar, dry When the flow read on the diagram is referred to operating pressure instead of standard conditions, the pressure drop p read on the diagram must be multiplied for the factor (1+ relative pressure in bar): Example: In the 1/2 filter with an air flow of 10 Nm 3 /h there is a pressure drop p = 3 mbar. If we consider that 10 m 3 /h is the flow at 2 bar of inlet pressure, then the pressure drop to be consider is: p = 3 x (1 + 2) = 9 mbar Filter must be selected considering the following: - Pressure drops p 10 mbar - Flow velocities w 20 m/s Gas type Specific gravity ρ [Kg/m³] k = (1) Air 1,25 1,00 (2) Natural gas 0,80 1,25 (3) Town gas 0,57 1,48 (4) LPG 2,08 0,77 125. ρ GAS Normally, pressure drop and flow rate for the filters are read from the gas flow diagram. However, the filters can also be chosen in accordance with the characteristic Kvs value which is shown in table 2. The selection of the filter requires the calculation of the Kv under the operating conditions. Considering only subcritical pressure drops: p < p 1 2 Kv can be calculated with the formula: ( t + 273) V ρ Kv = 514 p p where V = flow rate [Nm 3 /h] Kv = flow factor [m 3 /h] ρ = density [Kg/m 3 ] p 1 = absolute inlet pressure [bar] p 2 = absolute outlet pressure [bar] p = differential pressure p 1-p 2 [bar] t = media temperature [ C] 2 To the Kv value calculated from operating conditions we add an allowance of 20%, to obtain the minimum Kvs value which the filter should have: Kvs > 1,2 Kv Example: We need a filter with a capacity of 10 Nm 3 /h of air at 15 C, with an inlet pressure p 1 = 2 bar. Considering a pressure drop p max = 10 mbar, we obtain: 5-6

( + 273) 10 1.25 15 3 Kv = = 2.13 m / h 514 0.010 (1 + 2) The filter with Kvs > (1,2 x 2,13) = 2,5 m 3 /h is the Rp1/2, which has Kvs=6.8 m 3 /h (table 2). The diagram shows that in a Rp1/2 filter with 10 Nm 3 /h of air there is a pressure drop: p = 9 mbar Ordering information Tab.4 FF 3 2 - Filter type FF or FFS Connections size 1 = 1/2 2 = 3/4 3 = 1 35 = 1 1/4 4 = 1 1/2 6 =2 Max pressure: 2 bar Special version +: FFS12 or FFS22 with 30µm filtering element A: pressure gauges 1/8 (except FFS12 and FFS22) Example: FFS22: fuel filter with connection ¾ (max pressure 2 bar, mesh filtering element 50 µm) FF352: fuel filter with connection 1 1/4 (max pressure 2 bar, filtering element 30 µm) FFS12+: fuel filter with connection ½, filtering element 30 µm (max pressure 2 bar) FF62A: fuel filter with connection 2, pressure gauges 1/8 at inlet and outlet (max pressure 2 bar, filtering element 30 µm) Manufacturer reserves the right to update or make technical changes without prior notice. Standards and approvals Quality Management System is certified according to UNI EN ISO 9001 and the monitoring is carried out by the notified body: Kiwa Gastec Italia Spa Via Treviso, 32/34 I- 31020 San Vendemiano (TV) Deltapumps is a brand name of: Elettromeccanica Delta S.p.A. Via Trieste 132 31030 Arcade (TV) - ITALY tel +39 0422 874068 fax +39 0422 874048 www.delta-elektrogas.com info@delta-elektrogas.com Copyright 2014 All rights reserved 6-6