BathySurvey A Trimble Access hydrographic survey module

Similar documents
Survey Technical Support Notes October 2015

APA software instruction manual

Hi-Target Echosounder Operation Manual. Catalogue

SPLIT HOPKINSON PRESSURE BAR OPERATIONS MANUAL 5/9/2014

CONSTRUCTION OF LNG RECEIVING TERMINAL ON THE SAINT LAWRENCE TIDAL CURRENT CONDITIONS IN THE LEVIS AREA

Sontek RiverSurveyor Test Plan Prepared by David S. Mueller, OSW February 20, 2004

GNX 20/21. Owner s Manual

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

500 Series Operations Manual _A

Touch Screen Guide. OG-1500 and OG Part # T011

USCGC HEALY WAGB-20 Final Report RD Instruments Inc. Ocean Surveyor 75 khz Prepared by: Ron Hippe Commissioning Dates: 3/27/2002-3/30/2002

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

Pilot 3380 A U T O P I L O T. Operation Manual NAVMAN

14/10/2013' Bathymetric Survey. egm502 seafloor mapping

141c Operations Manual _B

BOTTOM MAPPING WITH EM1002 /EM300 /TOPAS Calibration of the Simrad EM300 and EM1002 Multibeam Echo Sounders in the Langryggene calibration area.

GNX 20/21. Owner s Manual

_A - 747c_&_777c2_Man_Eng.qxp 10/2/2006 1:40 AM Page c and 777c 2 Operations Manual _A

TECNAUTIC_GmbH. Display Functions with the PB100/200 connected: -- GND Speed -- GND Course -- Heading (Gyro option is recommended) 2 m

KEM Scientific, Inc. Instruments for Science from Scientists

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

User manual STONEX E6

GNX 20/21 Owner s Manual

NEED FOR SUPPLEMENTAL BATHYMETRIC SURVEY DATA COLLECTION

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Operations Manual. Matrix 10 Matrix 27. Matrix 17 Matrix 37. offered by Busse-Yachtshop.de _A

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

KIV-SACS Safe automatic calibration system:

Monsoon3V+ Multiple Pump VFD Control System. Please pass these instructions on to the operator of this equipment.

Advantages of Using Combined Bathymetry and Side Scan Data in Survey Processing T.M. Hiller, L.N. Brisson

FF525 INSTALLATION and OPERATION GUIDE

Instruction Manual. BZ7002 Calibration Software BE

EZ Boom 2010 System for the EZ Guide 500 Lightbar Triangle Ag Services Users Guide

FF525 INSTALLATION and OPERATION GUIDE

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

Evaluation of the Klein HydroChart 3500 Interferometric Bathymetry Sonar for NOAA Sea Floor Mapping

WinRiver II User s Guide

Low-Flow Purging Procedure with MicroPurge basics Equipment. MP10 Bladder Pump Controller MP15 Control. MP30 Drawdown Meter.

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

GHC 20. Owner s Manual

GHC 20 Owner s Manual

GNX 120/130. Owner s Manual

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

Hydro-Control V User Guide

USER GUIDE FOR DATALINE-X SDX. Stowe Marine Ltd. Tel +44(0)

USING THE GPS TO WALK TRANSECTS. by Robert L. Hafey

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

Astral in AirView: Improving patient care through connectivity. ResMed.com

Design Envelope Booster. Sequence of operation

S100 Controller. User guide. English Date: Document number: EN 2006 Raymarine UK Limited

Viva TPS. TS11/15 Total Stations Check and Adjust Procedure. October Summary

This guide relates to the CPN Series Chart Plotters CPN700i and CPN1010i

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

Remote Control Bait Boat

Roller AC Servo System

BUBBLER CONTROL SYSTEM

APOS LBL and MULBL Course

WMB-160F Multi-beam Fishing System

ENVIRONMENT AGENCY GREAT OUSE AND 100 FT DRAIN QUARTERLY BATHYMETRIC SURVEY DECEMBER 2013 SITE SURVEY REPORT NO. H6787

Wickets Administrator

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

APPLICATION NOTES. WIND MEASURING SYSTEMS using XDi-N indicators. Document no.: B

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

Digital Vacuum Regulator

[MYLAPS INTEGRATION]

Overview. 2 Module 13: Advanced Data Processing

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

STM-3. Surface Station. Technical Reference Manual. October Desert Star Systems Imjin Road. Marina, CA (831)

AHE58/59 AC Servo System

WELCOME TO THE REVOLUTION

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003

UNDERGROUND SURVEY WITH MINEMODELLER

Malta Survey activities

Datasheet: K-30 ASCII Sensor

Data Collection and Processing: Elwha Estuary Survey, February 2013

SHIMADZU LC-10/20 PUMP

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007

Measuring Discharge in Shallower Rivers: ADCPs go from Rio to Pro

Real Time Surveying GPS and HYDRO Software for Tide and Swell Compensation

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

SonoMeter 30 Energy Meters

New product release. Universal Rebreather Monitor (URBM) Three cell / Independent backup

HART Communications Board

This addendum describes the back pressure control implementation if FuelCell Version 4.1a and later.

SAUTER flexotron 800 heating. List of network variables for Modbus communication. Manual P A P

Astral in AirView: Improving patient care through connectivity. ResMed.com

Cover Page for Lab Report Group Portion. Pump Performance

Multifunction Altimeter/Variometer AV1

Lab 1. Adiabatic and reversible compression of a gas

Lucid System In-Service Training

PC Configuration software for Discovery MkVI v 1.03 User guide

Lab 1: Pressure and surface tension. Bubblers, gravity and the mighty paper clip.

New product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package

WATER CONTROL SYSTEM QUICK START

Transcription:

BathySurvey A Trimble Access hydrographic survey module

Contents 1. Introduction... 3 2. Installation... 4 3. Main Screen... 5 4. Device... 6 5. Jobs... 7 6. Settings Odom Echotrac... 8 7. Settings Ohmex Sonarmite... 14 8. Barcheck Odom Echotrac... 15 9. Barcheck NMEA... 19 10. Online... 21 11. Gain/ TX... 22 12. Scale... 23 13. Record... 24 Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 2

Introduction BathySurvey is a plugin for the Trimble Access software. It s a hydrographic software package capable of communicating via a serial port with an echo sounder. At the moment the following echo sounders are supported: Odom Echotrac CVM Odom Echotrac CV100 Ohmex Sonarmite NMEA DBS NMEA DBT BathySurvey adds a depth to a GNNS position record. A custom stylesheet is delivered with the software to convert the Trimble Access Job file to a comma separated ASCII file. When using the Odom Echotrac CVM/ CV100 or Ohmex Sonarmite the settings of the echo sounder can be changed. The NMEA protocols are just for reading the depth(s) from an NMEA string. A barcheck wizard can determine the transducer depth and sound velocity. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 3

Installation After installing BathySurvey via the Trimble Access Installation Manager the BathySurvey icon will appear on the main screen of Trimble Access. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 4

Main Screen The Bathy Survey main screen has four buttons and one soft key to choose the correct echo sounder device and communication parameters. Always start by checking the device settings. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 5

Device Choose the correct echo sounder and communication settings. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 6

Jobs Has the same functionality as the Jobs menu in General Survey. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 7

Settings Odom Echotrac After starting the settings menu from the main screen BathySurvey will query the echo sounder settings. This will take a couple seconds. After the message Updating Finished appears you will be able to change the settings. The maximum operating depth range of the echo sounder. Valid parameters from 0 to 12000 meters. The default is 45 meter. Blanking level to digitizer. Digitizer will not track anything above this depth. Valid parameters from 0 to 12000 meters. The default is 0 meter. Minimum depth alarm. The echo sounder will sound an alarm if the depth is shallower than this depth. Valid parameters from 0 to 30 meters. The default is 0 meter. The Defaults button will reset all the echo sounder parameters. Note that this will set the communication baud rate to 19200. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 8

When set to 0 the echo sounder pings at the highest rate for that depth. When set from 1-20 the echo sounder will sound up to a maximum to that ping rate/sec as long as the water depth allows it. Valid parameters from 0-20. Default is 0. Echo Alarm. When switched on the echo sounder will sound an alarm when the depth is shallower the the set minimum depth. Standby Bit. When set to On the echo sounder will go to standby when turned on. High frequency channel operating frequency. Valid parameters from 12 to 1000 khz. Default is 200 khz. High frequency channel pulse width in cycles. Valid parameters from 1 to 256. Default is 20. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 9

Low frequency channel operating frequency. Valid parameters from 8 to 200 khz. Default is 24 khz. Low frequency channel pulse width in cycles. Valid parameters from 1 to 256. Default is 20. Draft of high frequency transducer. Valid parameters from 0 to 1500 centimeters. Default is 0 centimeter. Index error of high frequency transducer. (Opposite of draft) Valid parameters from 0 to 1500 centimeters. Default is 0 centimeter. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 10

Draft of low frequency transducer. Valid parameters from 0 to 1500 centimeters. Default is 0 centimeter. Index error of low frequency transducer. (Opposite of draft) Valid parameters from 0 to 1500 centimeters. Default is 0 centimeter. The Sound Velocity. Valid parameters from 1370 to 1700 m/s. Default is 1500 m/s. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 11

Function and baud rates of the serial ports. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 12

Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 13

Settings Ohmex Sonarmite With the Toggle button you can switch between the different outputs of the Sonarmite. When you reach the SYS output, the sound velocity (7 th field) can be changed with the up and down buttons. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 14

Barcheck Odom Echotrac You can use the barcheck wizard to determine the transducer draft and sound velocity. Choose the channel to calibrate. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 15

Enter the initial sound velocity to get an approximate depth. The default is 1500 m/s. Enter the draft of the transducer as physically measured from water surface to bottom of transducer. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 16

Deploy the bar below the transducer at a depth of less than 5 meters and enter the bar s known depth. Set the width of the digitizer gate to eliminate returns other than the bar. Once you have a digitized depth from the bar press calculate to get the draft and index. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 17

Deploy the bar below the transducer to the deepest calibration depth and enter the bar s known depth. Set the width of the digitizer gate to eliminate returns other than the bar. Once you have a digitized depth from the bar press calculate to get the sound velocity. If you are doing your survey using RTK, make sure to check the Reset Draft en Index checkbox. The draft and index parameters will then be set back to zero. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 18

Barcheck NMEA Deploy the bar below the transducer at the shallowest calibration depth and enter the transducer draft. Draft = Bar Depth Digitized Depth Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 19

Deploy the bar below the transducer to the deepest calibration depth and enter the bar s known depth and the sound velocity as setup in your echo sounder. Once you have a digitized depth from the bar press calculate to get the sound velocity. When using NMEA output from an echo sounder you can use the calculated sound velocity to change the sound velocity setting in your echo sounder. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 20

Online The Online screen shows a side view of the bottom profile. When a second frequency is used it will become visible in light yellow. The lower frequency is drawn behind the higher frequency. At the bottom the depth and speed are shown. When using a Sonarmite the battery voltage and quality indicator are also shown. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 21

Gain/ TX To set the gain and Tx power for the Odom Echotrac. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 22

Scale To set the bottom side view plot scale and the speed units. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 23

Record Pressing Record from the Online screen will start a continues topo measurement. Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 24

Naam document: Bathysurvey Manual Versie: 1.00 Datum: 26-7-18 Auteur: Ruud van der Linden 25