Manual retractable fitting with safe-to-operate rotary drive

Similar documents
Pneumatic retractable fitting for simple commercially available control units or process applications

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Sanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Pneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas

Armatures for analytical probes

Technical Information Cleanfit CUA451

ph measuring system for hygienic process applications

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Expansion Thermometers Stainless Steel Series, Model 70

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

High-performance submersible pressure transmitter For level measurement Model LH-10

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

VSR modulating valves with membrane actuator

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Tank Blanketing Pressure Regulators RHPS Series

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Corporation Stops Technical Bulletin

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Cable Glands. Special Applications. RoHS Compliance. Plastic & Metal Cable Glands Adapters Reducers & Enlargers Grommets & Accessories

Retractable Process Assembly

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves

Instruction presentation Special valves

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

FILTER TYPE PRESSURE SNUBBER

INDUSTRIAL EXCESS ESS FLOW VALVES

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

HIGH-PRESSURE RELIEF VALVES

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

Pressure Dump Valve Service Kit for Series 2300 Units

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

HOVAP SERIES 9600 BASICFLOW PROCESS VALVES INSTRUCTION MANUAL

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Pressure Transmitter P41

B84G - Excelon Plus Modular System General purpose filter/regulator

Schroeder Check Test Point System

SITRANS P measuring instruments for pressure

High-performance submersible pressure transmitter For level measurement Model LH-10

Monitoring device NTS 30

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

TECHNICAL BULLETIN. Sigma-Aldrich Pure-Pac II System. Technical Bulletin AL-236

Oxygen Measurement Systems High Reliability and Wide Application Coverage

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION

VCO O-ring Face Se al Fit tings

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

R84G - Excelon Plus Modular System Pressure regulators

L21S/SR/ST Glass Level Gauges

Overview. VARICOVER product recovery systems. Special features. Recover the value, reduce the waste! Design with no dead-zones.

Type 4708 Supply Pressure Regulator

ATS430 turbidity sensor Retractable insertion assembly

Operating instructions - Translation of the original -

SITRANS P measuring instruments for pressure

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Pneumatic Powered - Plunger Pumps

Robolux Multiway Multiport Diaphragm Valve, standard product range

Type 4708 Supply Pressure Regulator

Magnetic Level Gauges

shutoff valves 900 Series psig Manual Shutoff Valves

Company Profile.. About Sammi Machinery

FIELD DEVICES ANALYTICAL Product Specifications

Pressure Reducing Valve DMV 755

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Hydraulic hand test pump Models CPP700-H and CPP1000-H

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846

Ultrasonic. Continuous level measurement. Overview Page 64 VEGASON series 60 Page 66 AL-EN

MyControl Bathing System Signature Series

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

B-Too Drilling and Tapping Machine

Pressure Measurement Single-range transmitters for general applications

CLARK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe Sizes, Rugged Molded PPA Construction

Coiling Tube with Twist-Proof Fitting

Continental Industries STEEL SERVICE TEES or FAX Visit

Pneumatic Gripping Modules. Pneumatic 2-Finger Radial Grippers

DTG - LCD Digital Temperature Gauge USER MANUAL

Aluminium, white with black lettering. Bar. Option with unit bar/pa, bar/psi, kpa, MPa, psi

ALF400 to 900, ALT-5/-9

Booster Regulator/Air Tank

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

Stirred Reactors and Pressure Vessels

Pilot valves for pilot operated servo valves

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Transcription:

Manual Retractable Fittings SensoGate W M Manual retractable fitting with safe-to-operate rotary drive Revolutionary operation The SensoGate W M has a manual rotary drive, which enables the fitting to be operated up to a counter pressure of 45 psi ( bar) and this in less than two rotations. Regardless of how unfavorable the angle or the operating height at which the fitting is installed. Little rotary force is required and is easily applied manually. This is not possible with the sliding motion of conventional retractable fittings. Maximum process safety The configuration of the O-rings means that there is never any connection between the drain opening of the cleaning chamber and the process, even during inward and outward movement of the sensor. For maximum process safety, the sensor can only be removed in the service position. utomatic insertion protection reliably blocks the movement of the fitting and prevents extension into the process position without a sensor. Facts ompact, buildup resistant design Low maintenance Simple replacement of seals due to divided calibration/cleaning chamber Increased service life and reduced seal wear TEX approval II G c II for the complete fitting Low cost, simple installation, operation, and maintenance SensoLock for high operational safety Integrated limit switches Fast and easy replacement of calibration chamber and insertion tube ll maintenance can be performed on site yclone cleaning effect Standard sensor length (5 mm) even for large immersion depths Multiple process connections available Flange version with scraping ring Modular design allows specific replacement of the process-wetted materials: PEEK, PVF, PP, 6 SS, Hastelloy Plastic versions with high pressure and temperature resistance due to carbonfiber-reinforced plastics Special version for sensors with pressurized liquid electrolyte 56

For up-to-date information, please visit www.m4knick.com Specifications Permissible process pressure and temperature during movement Process material 6 SS/ 45 psi ( bar) (at ( 84 F) 4 )) Hastelloy Process material PEEK H Process material PVF H Process material PEEK / PVF Process material PP Permissible process pressure and temperature, in service position mbient temperature 45 psi ( bar) (at ( 84 F) 4 )) 45 psi ( bar) ( 48 F ( )), 6 bar (84 F (4 )) min 87 psi (6 bar) ( 4 F ( 4 )), falling linearly to 9 psi ( bar) (48 F ( )) 87 psi (6 bar) (4 86 F (5 )), falling linearly to 4.5 psi ( bar) (76 F (8 )) psi (6 bar) (at 4 F ( 4 )), PP bars (at 5 ) 4 58 F ( 7 ) Ingress protection IP 66 Housing material Permissible pressure for probe control s With gel electrolyte With liquid electrolyte Stainless steel /PP or stainless steel/peek 58 psi (4 7 bar) Ø mm, length 5 mm with temp detector, Pg.5 thread Ø mm, length 5 mm with temp detector Process connections Flanges, IN EN 9- N Flanges, NSI 6.5 /; to ; Threaded ; NPT airy pipe, IN 85 N 5 Ingold socket, 5 mm G /4; onnections Rinse and calibration media (optional) Outlet (optional) For pressurized sensors Immersion depths/ Installation dimensions Process-wetted materials 5 mm for Knick RF/X internal thread G /8;, hose coupling G /8;-N 4/6 outlet hose, NW 8 EPM m hose connection NW 6, pressure in sensor chamber.5 bar above process pressure (max. 7 bar) see dimensional drawings see order code 57

Manual Retractable Fittings SensoGate W M for process applications Product Line Order No. Process sensor lock-gate, pneumatic W M / _ Explosion protection for hazardous area Zone without X N solid electrolyte liquid electrolyte (pressurization possible) Gasket material elastomeric ring set, FKM (Viton) elastomeric ring set, EPM elastomeric ring set E, EPM F elastomeric ring set K, FFKM, compl. (Kalrez) E K Process-wetted materials*} 6 SS /6 SS /6 SS Hastelloy / Hastelloy / Hastelloy PEEK / PEEK / PEEK PVF / PVF / PVF PEEK H / PEEK H / PEEK H PVF H / PVF H / PVF H PP reinforced E F P Process adaptation flange, steel, 6 SS, N flange, steel, 6 SS, N 4 flange, steel, 6 SS, N 5 flange, steel, 6 SS, N 65 flange, steel, 6 SS, N 8!} flange, steel, 6 SS, N!} dairy pipe, N 5 dairy pipe, N 65 dairy pipe, N 8 dairy pipe, N flange, NSI 6 SS, /; flange, NSI 6 SS, ; flange, NSI 6 SS, /; flange, NSI 6 SS, ;!} 4 4 Immersion depth Ingold socket, 5 mm H G /4; for RF /xxxxx K NPT " (male) N short long Electrical limit signal with without Rinse-medium connection G /8; complete with outlet hose ( m) G /8; complete with outlet hose ( m), inlet G /8; G /8; complete with outlet hose ( m), inlet G /8; and inlet hose (5 m) complete with coupling nut Housing material stainless steel / PP (< 6 bars operating pressure) stainless steel / PEEK (< bars operating pressure) Special variant without equipped with special grease (provided by customer) with scraper ring, reinforced version, PTFE/PEEK (ZU 76) reduced stroke (shortened immersion depth) 4 58 * ) Material combinations: Process-wetted part of calibration chamber/rinse-wetted part of calibration chamber/immersion tube ) With the lower calibration chamber made of plastic, you require one of the following flange protectors: ZU 755, ZU 756, ZU 757, ZU 758

For up-to-date information, please visit www.m4knick.com ccessories Order No. Service set basic equipment ZU 68 maintenance, repair, retrofit ZU 74 calibration chamber ZU 754 mounting wrench, 9 mm ZU 647 Mounting aid for x.5 O-rings ZU 747 for scraper ring ZU 746 ellows version for liquid-electrolyte sensors ZU 79 Protective cap version for sensors with polymeric electrolyte ZU 759 Scraper ring reinforced version, PTFE/PEEK ZU 76 Material ertificate. ZU 78 ir supply for pressurized sensors, 7 58 psi (.5 4 bar) ZU 67/ for pressurized sensors, 4.5 psi ( 7 bar) ZU 67/ Hose m (extension for ZU 67) ZU 7 Flange protectors PEEK / FFKM N 8 ZU 755 PEEK / FFKM N ZU 756 PVF / FFKM N 8 ZU 757 PVF / FFKM N ZU 758 Weld-in socket, beveled 5, PP, length 6 mm Safety weld-in socket, straight, 4 mm ZU 8 for tank wall ZU 77 for pipe, N 5 ZU 77/N5 for pipe, N 65 for pipe, N 8 for pipe, N ZU 77/N65 ZU 77/N8 ZU 77/N Safety weld-in socket, beveled 5, 4 mm for tank wall ZU 78 for pipe, N 5 ZU 78/N5 for pipe, N 65 for pipe, N 8 for pipe, N ZU 78/N65 ZU 78/N8 ZU 78/N for tank wall, Hastelloy ZU 78/ Retainer clamp for 5-mm socket ZU 88 59

Manual Retractable Fittings SensoGate W M for process applications Gaskets Set ontact (process/rinse medium) Order No. Flange or dairy pipe / / / / E/ E/ K/ K/ Ingold socket H / / FKM: Viton FFKM: Kalrez, hemraz, Perlast / / E/ E/ K/ K/ FKM FKM / FKM EPM EPM / EPM EPM F EPM F / EPM FFKM FFKM / FFKM FKM FKM / FKM EPM EPM / EPM EPM F EPM F / EPM FFKM FFKM / FFKM ZU 689/ ZU 89 ZU 69/ ZU 8 ZU 69/ ZU 8 ZU 69/ ZU 8 ZU 69/ ZU 8 ZU 694/ ZU 84 ZU 696/ ZU 85 ZU 695/ ZU 86 Spare Parts Order No. Immersion tube, short 6 SS ZU 7 Hastelloy ZU 85 PEEK ZU 74 PVF ZU 76 PP ZU 85 Immersion tube, long 6 SS ZU 7 Hastelloy ZU 854 PEEK ZU 75 PVF ZU 77 PP ZU 86 6

For up-to-date information, please visit www.m4knick.com imensional rawings Installation dimensions for SensoGate W M with short immersion depth for sensors with gel electrolyte Installation dimensions for SensoGate W M with long immersion depth for sensors with gel electrolyte Installation dimensions for SensoGate W M for sensors with liquid electrolyte Pg.5 Pg.5 5 mm pprox. 5 mm clearance for sensor installation 7 5 mm Ø pprox. 5 mm clearance for sensor installation 76 Ø pprox. 855 mm clearance for sensor installation 5 mm Ø SensoGate W M Process adaptation for flange, N N NSI 6 SS, /; ;, short and long immersion depth (I) SensoGate W M Process adaption for 5 mm Ingold socket, short and long immersion depth (I) SensoGate W M Process adaptation for dairy pipe, IN 85 N 5 N, short and long immersion depth (I) 65 (short I) (long I) 88 (short I) 4 (long I) 7 (short I) 6 (long I) 45 94 (short I) 49 (long I) 65 (short I) (long I) 88 (short I) 4 (long I) 6