MTS SafeGuard Technology. Solutions to protect test operators, equipment and specimen. be certain.

Similar documents
Implementing Emergency Stop Systems - Safety Considerations & Regulations A PRACTICAL GUIDE V1.0.0

PL estimation acc. to EN ISO

New Thinking in Control Reliability

Safety in pneumatic automation

Session: 14 SIL or PL? What is the difference?

Why do I need dual channel safety? Pete Archer - Product Specialist June 2018

The following gives a brief overview of the characteristics of the most commonly used devices.

The Best Use of Lockout/Tagout and Control Reliable Circuits

Integrating Safety and Automation

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Safely on the way in the automotive and Tier 1 supplier industry

High Integrity Pressure Protection Systems HIPPS

628 Differential Pressure Decay Leak Tester

Managing for Liability Avoidance. (c) Lewis Bass

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

Technical Tip. LoadAdaptive TM Counterbalance Valves. Introduction. Overview. August 2015

Technical Tip. LoadAdaptive TM Counterbalance Valves. Introduction. Overview. November2015

Introduction to Machine Safety Standards

SEMPEO SQA Unit Code FP2P 04 Maintaining fluid power equipment

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

CT433 - Machine Safety

Safety manual for Fisher GX Control Valve and Actuator

Applicable and have been incorporated into North American Standards.

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Safe hydraulics for hydroforming presses. more finished product to be created from less raw material.

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Safety Legislation and Standards

SARM-ANALYSIS. VERSION 3.0 Copy # 3 of 3

Phuel Portable Control Units

Autocalibration Systems For In Situ Oxygen Analyzers

Autocalibration Systems for In Situ Oxygen Analyzers

LIFTING MAGNETS ERIEZ MAGNETICS

General maintenance engineering applications

Keeping your critical equipment up and running. What the LifeSense system can do for you. LifeSense technology: monitors in real time

Phuel Modular Control Units

E28/Q28 Safety Exhaust Valve Externally Monitored

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

Grantek Systems Integration

SEMEM3-65 Servicing anaesthetic and ventilation equipment

DeZURIK. KSV Knife Gate Valve. Safety Manual

GAS FUEL VALVE FORM AGV5 OM 8-03

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

General maintenance engineering applications

Safety Circuit Design. Heinz Knackstedt Safety Engineer C&E sales, inc.

SEMEM SQA Unit Code HWAW 04 Carrying out maintenance activities on fluid power equipment

SEMEM3-73 Maintaining medical gas pipeline systems and equipment

Surge suppressor To perform its intended functions, an AEI site must have the components listed above and shown in Fig. 4.1.

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Partial Stroke Testing. A.F.M. Prins

Valve Communication Solutions. Safety instrumented systems

Advanced Test Equipment Rentals ATEC (2832)

Safety Manual VEGAVIB series 60

Section 4: Sequence valve adjustments

Application Note. Safety Sub-functions SSC Category 1, up to PL c PUS Category 1, up to PL c. Application Note SSC, PUS, Category 1, up to PL c STOP

Proportional pressure regulators VPPE

Every things under control High-Integrity Pressure Protection System (HIPPS)

Guidelines on Surveys for Dynamic Positioning System

RPS900W Redundant Power Supply. Installation Guide.

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Pressure maintenance valve SDV-P / SDV-P-E

SEMEMI SQA Unit Code H2AP 04 Carrying out fault location on electrical equipment and circuits

ASB Accumulator Safety Blocks

Safety Manual VEGAVIB series 60

Drass. 700 Series Surface Diving System

Fail Operational Controls for an Independent Metering Valve

Machine Safety Guide 1

Stand-Alone Bubble Detection System

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

Fail operational controls for an independent metering valve

Lockout/Tagout CE Marking Requirements WHITE PAPER

L&T Valves Limited SAFETY INTEGRITY LEVEL (SIL) VERIFICATION FOR HIGH INTEGRITY PRESSURE PROTECTION SYSTEM (HIPPS) Report No.

Table 1: Safety Function (SF) Descriptions

Functional Safety SIL Safety Instrumented Systems in the Process Industry

Application Note. Safety Sub-function PUS Category 1, up to PL c. Application Note PUS, Category 1, up to PL c M20 S22 R20 M1 Q20

Safety Rope Pull Switches SR and SRM

Quick Reference Guide Power Series Switches

SkillGuide. User Guide. English

Leakage Current Testing Is it right for your application?

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Applications. What moves your world

EMERGENCY SHUT-DOWN RELIABILITY ADVANTAGE

WORKSHOP SAFE ENGINEERING

DeZURIK Double Block & Bleed (DBB) Knife Gate Valve Safety Manual

SEMEM3-78 Testing and calibrating instrumentation and control equipment and circuits

Safe Machinery Handbook

METROTEC GSM. Type GSM. Oxygen measurement and control unit. *** Version 1.6 ***

Safe Machinery Handbook

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

P33 Safety Exhaust Valve Externally Monitored. Bulletin 0700-B14 ENGINEERING YOUR SUCCESS.

Connect with Confidence NO POWER NO PROBLEM

Functional safety. Functional safety of Programmable systems, devices & components: Requirements from global & national standards

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

SEMI Headquarters 3081 Zanker Road City, State/Country: San Jose, CA, USA San Jose, CA, USA Leader(s):

[Instruments for vacuum measurement, checking and adjustment] 3

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Transcription:

l MTS SafeGuard Technology Solutions to protect test operators, equipment and specimen be certain.

MTS PROVIDES INDUSTRY-LEADING SAFETY TECHNOLOGY FOR HYDRAULIC SYSTEM CONTROL. THESE SAFETY SOLUTIONS CREATE A TESTING ENVIRONMENT THAT IS SAFER FOR THE HUMAN OPERATOR AND THAT CAN BE CERTIFIED TO PERFORMANCE LEVEL-C (PLc), PLd, AND PLe STANDARDS. THIS MANAGED CONTROL OF HYDRAULIC PRESSURE IS ESSENTIAL TO MAINTAINING A SAFE OPERATING ENVIRONMENT.

Safer Operating Environment Successful testing requires protection of the test equipment and specimen, and most importantly, the test operator. Unfortunately, many systems that are designed to ensure human safety, negatively impact testing fidelity. So, although these solutions provide a safer environment, they also impede testing productivity and compromise testing accuracy. With MTS SafeGuard TM Technology, you can create a safer environment for test operators while protecting the test equipment and specimen, and maximizing test fidelity. 3 Importance of Functional Safety With the power to apply significant force at startling velocities, a test system needs to function in an accurate and safe manner to maintain a safe operating environment. Unplanned actuator movement or unexpected hydraulic pressure states must be detected and controlled quickly to provide the best possible environment for human safety. Functional safety is a term that typically applies to electrical, electronic and programmable electronic systems, and it is defined as a system or equipment that is operating correctly in response to its inputs. Meeting functional safety requirements requires active systems to detect potentially dangerous conditions. It also requires the activation of a protective or corrective device or mechanism to prevent hazardous events or reduce escalating consequences. Determining the Right Level of Safety Although organizations strive to provide a safe working environment, there is still a great deal of confusion about best practices and compliance requirements for safe operation of machinery. ISO 13849 offers clear guidelines to define the potential safety risk to humans and to determine the required Safety Performance Level for each situation. This international standard is a common end-user requirement in the EU and is referenced in many other regional safety standards. Three factors influence the required Performance Level: 1. Potential severity of injury 2. Frequency of exposure 3. Possibility of limiting the hazard Please consult the chart at the back of this brochure for more details on the safety performance levels. 2006/42/EC MACHINERY DIRECTIVE EN ISO 13849 Safety of machinery Safety related parts of control systems General principles for design EN ISO 13849 is an international standard common in the EU Defines required Performance Level (PLr) for safety function Categorizes five Performance Levels; a through e, with e being the highest level Test equipment used in the EU will typically comply with the standard Applies to EU countries and countries with trade ties to the EU GLOBAL SAFETY STANDARDS Many regional safety standards, such as ANSI B11 and CSA Z432, reference ISO 13849 vs. vs. Human Safety Without MTS SafeGuard Technology Equipment & Specimen Protection + + Testing Accuracy Providing a safe environment for the test operator without consideration of other factors, often compromises specimen protection or testing accuracy. MTS SafeGuard Technology provides the right level of human safety without impeding testing fidelity or productivity. Human Safety Equipment & Specimen Protection Testing Accuracy With MTS SafeGuard Technology

Components of the MTS SafeGuard Solution MTS SafeGuard Technology provides PLd and PLe Compliant Solutions MTS SafeGuard Technology can be used on any mechanical test system to provide safe power isolation and safe actuator speed control. MTS SafeGuard 273 Processor Manages safety and specimen protection Scalable up to 4 stations Configures to each safety system 4 mounting configuration options Can integrate with facility safety systems MTS SafeGuard 274 User Interface Displays system configuration, system status & fault diagnostics Includes system reset function Includes system e-stop function 3 mounting configuration options MTS SafeGuard 275 Machine Interface Connects I/O for safety functions at system (safe speed, station stop, test area enclosure) Configurable per system Solutions for Hydraulic Distribution Systems Can replace current HSMs to achieve Performance Level d or e. A MTS SafeGuard 275.295 Machine Interface for the MTS Series 295 HSM A

Example System Layout of an MTS SafeGuard Solution 5 FREQUENCY OF TEST SPECIMEN AREA ACCESS IS A CRITICAL FACTOR A Performance Level rating of c, d or e is required to meet certain safety standards for most test equipment. Frequency of access and exposure to the test specimen area are the primary factors in determining the required safety performance level. Start Severity of Injury Normally Reversible Injury Normally Irreversible Injury S1 S2 Access and Exposure to Test Specimen Frequency >15 Minute and Exposure < 1/20 th Total Time Frequency < 15 Minute or Exposure > 1/20 th Total Time Frequency >15 Minute and Exposure < 1/20 th Total Time Frequency < 15 Minute or Exposure > 1/20 th Total Time F1 F2 F1 F2 Possibility of Avoiding the Hazard Scarcely Scarcely Scarcely Scarcely P1 P2 P1 P2 P1 P2 P1 P2 Required Safety Performance Level a b c d e Low Risk Safety Performance Level High Risk

Determining Appropriate Safety Performance Level Three factors influence the required Performance Level: 1. Potential severity of injury 2. Frequency of exposure 3. Possibility of avoiding the hazard SEVERITY OF INJURY Slight or Serious The two options for classifying equipment in the severity of injury category are: slight, indicating a normally reversible injury; and serious, indicating a normally irreversible injury or death. Due to the potential for irreversible injury or death when operating test equipment, mechanical test systems are considered to be in the serious classification, which requires a minimum of Performance Level c (PLc) for compliance. Slight Serious» Normally reversible injury» Normally irreversible injury or death» May require up to PLc» Most mechanical test systems would be classified in this category» Requires minimum of PLc FREQUENCY AND/OR DURATION OF EXPOSURE Seldom or Frequent For test equipment, the frequency of exposure is defined as access to the specimen area. Access typically occurs in specimen loading/unloading, alignment etc. The two options for classifying equipment in the frequency of exposure category are seldom and frequent. With respect to exposure time, seldom is defined as accessing the specimen area no more than once in 15 minute intervals and the accumulated exposure time does not exceed 1/20 of the overall operating time. Per this definition, the rating would be F1 for exposure. If the test operator is accessing the specimen more than once every 15 minutes or this exposure exceeds 1/20 of the overall operating time, it is considered frequent exposure. This would be an F2 rating for exposure. Frequent exposure of an F2 rating requires a minimum Performance Level d (PLd) for compliance. Seldom exposure could require a Performance Level of c or d, depending on the possibility of avoiding or limiting the hazard. Seldom Frequent» Access to the test specimen area once in fifteen minute or greater intervals AND exposure less than 1/20 total time» Access to the test specimen area more than once every fifteen minutes OR exposure more than 1/20 total time» Requires minimum of PLc if severity = S2» Requires a minimum of PLd if severity = S2 POSSIBILITY OF AVOIDING THE HAZARD or Scarcely There are two categories for possibility of avoiding the hazard or limiting the harm: possible under specific conditions or scarcely possible. A risk assessment can help determine the appropriate category. If there is a use case in which the possibility of avoiding the hazard is considered scarcely possible and severity = S2, then this case would require a minimum of Performance Level d. If in this same case, the frequency of exposure = F2, then it would require a Performance Level e solution. Scarcely» to avoid the hazard» Severe obstacles to avoiding the hazard» Most mechanical test systems would be classified in this category» Requires a minimum of PLd if severity = S2» Requires minimum of PLc if severity = S2

Safety Solutions for MTS Landmark Systems PERFORMANCE LEVEL C (PLC) PERFORMANCE LEVEL D (PLd) PERFORMANCE LEVEL E (PLe) Applicable for test systems in which the test specimen area is not accessed more frequently than once every 15 minutes. Applicable for test systems in which the test specimen area is accessed more than once every 15 minutes. Applicable for use cases where the possibility of limiting hazards is considered scarcely possible, or the risk tolerance is low. Performance Level c (PLc) is the standard option on most MTS Landmark Test Systems. This solution requires a load frame with test area enclosure* and a FlexTest controller. It includes a low flow power supply for safe speed control (<10 mm/s). Performance Level d (PLd) is the standard option on MTS Landmark Test Systems that are using hydraulic pressure of 57-114 lpm (15-30 gpm). This solution requires a load frame with test area enclosure*, a FlexTest controller and a MTS SafeGuard 272 Supervisor, formerly Load Frame Station Supervisor. It includes cables and hose kit. The PLd version adds redundancy and monitoring to the already high reliability of the PLc safety circuits. In addition, a safety-rated Programmable Logic Controller arbitrates the safety functions. Meeting Performance Level e (PLe) requires a custom solution. MTS has the experience necessary to create a system that meets PLe standards. *Must be supplied by MTS to be classified as PLc or PLd compliant. 7 REQUIRED FOR PERFORMANCE LEVEL D (PLd) COMPLIANCE WHEN SEVERITY = S2 MTS SAFEGUARD 272 SUPERVISOR Safety Programmable Logic Controller with single location for system AC power input/output Safe Power Off / Safe Isolation: floor-standing manifold with positive isolation and dump functions Safe Speed: adds monitoring to existing low flow valve and replaces the low flow power supply with LSS Handset with E-stop Load frame wiring harness with redundant chains to E-Stop and mode switching functions Test Area Enclosure (TAE) interlock switches and tamper-resistant fasteners Three-position keyed Mode Selection Switch (per EN 60204) Remote E-Stop/Status box with illuminated status indicators For EU deliveries, a System Level CE certification/ marking along with the applicable component certifications (Declaration of Incorporation/ Declaration of Conformity) will be provided MTS SafeGuard 272 Supervisor for use with MTS Landmark Test Systems Benefits of MTS SafeGuard Technology A safety system should not interfere with test system performance. MTS offers an ideal solution to maximize testing productivity and minimize risk. To be confident that your test system meets the specified safety performance level, MTS can supply System Level CE declaration along with the applicable component certifications: Declaration of Incorporation (DOI) or Declaration of Conformity (DOC) as required. Protecting test operators, equipment and specimen are all critical to testing success. MTS provides the tools to help meet the functional safety requirements, and the test systems that perform reliably test after test. Contact MTS today to learn more about test system safety requirements.

Regional Business Centers THE AMERICAS MTS Systems Corporation 14000 Technology Drive Eden Prairie, MN 55344-2290 USA Telephone: 952-937-4000 Toll Free: 800-328-2255 Fax: 952-937-4515 E-mail: info@mts.com Internet: www.mts.com EUROPE MTS Systems France BAT EXA 16 16/18 rue Eugène Dupuis 94046 Créteil Cedex France Telephone: +33-(0)1-58 43 90 00 Fax: +33-(0)1-58 43 90 01 E-mail: contact.france@mts.com MTS Systems GmbH Hohentwielsteig 3 14163 Berlin Germany Telephone: +49-(0)30 81002-0 Fax: +49-(0)30 81002-100 E-mail: euroinfo@mts.com MTS Systems S.R.L. a socio unico Strada Pianezza 289 10151 Torino Italy Telephone: +39-(0)11 45175 11 sel. pass. Fax: +39-(0)11 45175 00-01 E-mail: mtstorino@mts.com MTS Systems Norden AB Datavägen 37b SE-436 32 Askim Sweden Telephone: +46-(0)31-68 69 99 Fax: +46-(0)31-68 69 80 E-mail: norden@mts.com MTS Systems Ltd. UK 40 Alan Turing Road Surrey Research Park Guildford Surrey GU2 7YF United Kingdom Telephone: +44-(0)1483-533731 Fax: +44-(0)1483-504564 E-mail: mtsuksales@mts.com ASIA/PACIFIC MTS Japan Ltd. ArcaCentral Bldg. 8F 1-2-1 Kinshi, Sumida-ku Tokyo 130-0013 Japan Telephone: 81-3-6658-0901 Fax: 81-3-6658-0904 E-mail: mtsj-info@mts.com MTS Korea, Inc. 4 th F., ATEC Tower, 289, Pankyo-ro, Bundang-gu Seongnam-si Gyeonggi-do13488, Korea Telephone: 82-31-728-1600 Fax: 82-31-728-1699 E-mail: mtsk-info@mts.com MTS China Hechuan Office Room 703 Building #B, Venture International Park, No. 2679 Hechuan Road, Minhang District, Shanghai 201103, P.R.China Telephone: +86-21-5427 1122 Fax: +86-21-6495 6330 E-mail: info@mtschina.com l MTS Systems Corporation 14000 Technology Drive Eden Prairie, MN 55344-2290 USA ISO 9001 Certified QMS http://www.mts.com MTS, FlexTest, and MTS Landmark are registered trademarks and SafeGuard is a trademark of MTS Systems Corporation in the United States. These trademarks may be protected in other countries. RTM No. 211177. 2018 MTS Systems Corporation 100-418-386 SafeGuardTechnology Printed in U.S.A. 7/18