SAFETY PHILOSOPHY FOR SERVICE LINES AND GAS INSTALLATION

Similar documents
Annex to the Accreditation Certificate D-IS according to DIN EN ISO/IEC 17020:2012

Pressure Regulator 133 / 233

RESIDENTIAL REGULATORS

SV60 Safety valves. for use with steam, gas and liquids

Overview EUSSAM12. Carry out tightness testing and direct purging of gas installations

Gas Pressure Regulator HON 300

New Hampshire Public Utilities Commission CFR 49 Part 192 Regulations. MINIMUM Pipeline Safety Regulations

Pressure ranges and accuracy classes for outlet pressure and safety devices

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

Instruction Manual Dräger MSI P7 and MSI P7 plus

RR 16 Commercial & Industrial Regulator

OPERATING PROCEDURES

INOGATE Technical Secretariat UK Experience European Standards Implementation Key Expert Phil Winnard Session 2 Georgia, October 2015

Safety shut-off valve S 50. Product information

Gas plug-in hose, straight-through form. Instructions for Use. suitable for gas socket model G2019T, G2016T. G2023 from 01/1990.

Safety Shut-off Valve SSV

Safety shut-off valve S 100. Product information

TP Validating a dynamic grid model with tracer gas injection and analysis

Residential Pressure Booster Systems

PSI Mechanical Couplings

SPECIFICATIONS ATTENTION

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

1200B2 Series Service Regulators. Instruction Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

Safety Relief Valve HON 832

Actuator HON 670 / 671

Overview EUSDSG3.6. Gas tightness testing and direct purging

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

Safety Relief Valve HON 835

RTG 25. Introduction

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

A guide to Part 10 of the

V Safety features and equipment for biogas plants

SHANGHAI FIORENTINI GAS EQUIPMENT CO.LTD.

Dräger MSI P7 Combustion Gas Analysis

CanNeed-DSST-100 Digital Secure Seal Tester --- To evaluate the secure seal quality of PET bottles, glass bottles and cans

Pressure Systems Safety Regulation

627 Series Pressure Reducing Regulators

RR 16 Commercial & Industrial Regulator

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation, operation & maintenance manual - original version

Bringing Pressure Under Control: Harnessing Control Valves for Intelligent Water Networks. A Report on Best Practice from TALIS

MoveRoll Conveyor Operating and Maintenance Manual

Gas Pressure Regulator R 51

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

1800C and 1800C-HC Service Regulators

Tightness controls TC 1 3 and TC 4

Bermad Model:

SITE INSPECTION PROCEDURE FORM

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

Gas pressure regulator RS 254 / RS 255


Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Safety. Operating instructions. White meters BK V2 to BK V12. (component of a diaphragm gas meter) DANGER. Contents WARNING CAUTION

MOBILAIR M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.1 to 23.3 m³/min ( cfm)

PROTEGO Braunschweiger Flammenfilter GmbH

Regulator from 1800 B series

Manual. Gas burners gas burners without flame protection gas burners with flame protection.

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

1800C and 1800C-HC Series Service Regulators

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

DIRECTORATE OF ESTATES AND DEVELOPMENT CONTROL OF GAS NETWORK OPERATIONS

MOBILAIR M 210 / M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.0 to 23.3 m³/min ( cfm) COMPRESSORS

Covered Task 007OP Training Guide Operate Valves

safety shut-off Valve HON 703 / HON 704

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

Aquashield to Mitigate Water Ingress of Gas Pipes

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Safety Shut-Off Valve HON 720

MODEL 240 GAS PRESSURE REGULATOR

Covered Task 614OP Training Guide Purging Pipeline Facilities with Air or Inert Gas

Types S100K and S102K Pressure Regulators

Safety shut-off valve Control Control Lock-up Over pressure set point Under pressure set point pressure range accuracy class

Model: 43T. Bermad Pressure Relief Valve

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

CAST IRON SAFETY VALVE TYPE 6301

Gas pressure regulator RSP 254 / RSP 255. Product information. Regulator R / R / R Actuator AS 254 / AS 255

Float Valve Function and Design Considerations

SV5 Safety Valve Installation and Maintenance Instructions

Central Gas System Inquiry. Check List - Detailed Form

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S02

The Future of Hydraulic Control in Water-Systems

Assessing Permeation of Gas through Polyethylene Pipe

2017 LGA 191/192 & 195 Pipeline Safety Conference

Fire's Edge. Fire Pit or Fire Pit Insert Model 100A-M (Manual Operation) OWNER S MANUAL / OPERATING AND MAINTENANCE INSTRUCTIONS

DUPLEX PRESSURE REDUCING SET

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

Dri-Line Mk3 Monnier Compressed Air Drain Trap

A. Evaluation of the written program

safety Shut-Off Valve HON 721

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

for the of and the EM55-1

Homestead Series 820 AWWA Butterfly Valves

Technical data sheet. Nasagas Gas leak detector. Nasagas Data sheet. Microplan S.r.l Via Andrea Doria Sommacampagna (VR) - Italy

Self-operated Pressure Regulators for special applications

Instruction Manual. Pipe Friction Training Panel

Transcription:

23 rd World Gas Conference, Amsterdam 2006 SAFETY PHILOSOPHY FOR SERVICE LINES AND GAS INSTALLATION Main author Kerstin Grass Germany

ABSTRACT An overview of the requirements under DVGW standards concerning service lines and gas installation is given. The goals of the requirements regard the following areas: Prevention of unauthorised interference by a third party Identification of damage at an early stage Limitation of damage and defence against manipulation The standards to archive the goals consist of requirements concerning procedures and components, which are both described briefly.

TABLE OF CONTENTS Abstract Body of Paper 1 Introduction 2 Prevention of unauthorised interference by a third party 2.1 Cover 2.2 Investigation of service lines prior to civil engineering works 3 Identification of damage at an early stage 3.1 Leakage survey 3.2 Odourisation 3.3 Testing of the service line and the gas installation prior to commissioning 4 Limitation of damage and defence against manipulation 4.1 Excess flow valve outside (to guard the service line) 4.2 Excess flow valve inside (to guard installation) 4.3 Requirements of the residential service gas entry device (GED) 4.4 Safety features of the regulator 4.5 High temperature resistance 4.6 Main shut-off device References List of Tables List of Figures

1 Introduction In contrast to other national constructions in Germany the devices for pressure regulation (to 22 mbar) and gas measurement are typically placed inside the house (figure 1). The gas pressure prior to the regulation can be up to 5000 mbar, predominantly it does not exceed 1000 mbar. The requirements for the devices, the construction and the operation of the service lines (and the grid) are stipulated in the standards of the DVGW (Deutsche Vereinigung des Gas- und Wasserfaches e.v. - Technisch-wissenschaftlicher Verein = DVGW German Technical and Scientific Association for Gas and Water). The main task of the non-profit making association is the compilation of the technical standards and therefore the self-regulation in the gas and water supply industry. Concerning service lines the safety philosophy is based on three pillars: Prevention of unauthorised interference by a third party Identification of damage at an early stage Limitation of damage and defence against manipulation An overview of the requirements under DVGW standards concerning service lines and gas installation is given. Figure 1: A typical German construction of the service line and installation 2 Prevention of unauthorised interference by a third party 2.1 Cover The minimum cover for service lines is 50 cm [1], which ensures a sufficient distance for works in the area of the service lines. In many cases the cover is even larger, depending on the cover of the grid. The minimum cover for the grid is 60 cm, the usual one about 80 cm.

2.2 Investigation of service lines prior to civil engineering works Before starting civil engineering works any company is obliged to ask all affected network operators for the location of their grid and their service lines. It is the duty of the company that performs the civil engineering works to instruct their workers. The network operators take care of the up-to-dateness of their data und give indications as to how to work near pipes and service lines. To insure this special procedures are installed in the network operator companies, which also include a documentation that the information has been given. However, there is still a noteworthy amount of the so called third party interference and therefore there are discussions how to minimize it. Some companies carry out information events for the civil engineering companies or have formed partnerships with them. The reduction of third party interference is also discussed in the affected organisations, e.g. DVGW. 3 Identification of damage at an early stage 3.1 Leakage survey Leakage survey is carried out periodically, including both the grid and the service lines. Thus damage can be identified at an early stage. The frequency of the survey depends on the state of the grid (table 1). Typically the leakage survey is done on foot with special devices for the detection of methane and usually with a paper map of the grid. New developments concern the survey by car (usually just for the grid) and the use of digital maps. Frequency of leakages per km 0,1 0,5 1 Operating pressure in bar Period of survey in years 0,1 6 1) 4 2 > 0,1 to 1 4 1) 2 1 > 1 4 1) 1 0,5 1) only valid for PE pipes or cathodic protected steel pipes Table 1: Minimum period of survey [2] 3.2 Odourisation An odourant is added to the gas to allow the detection of it. In case of a leakage in the installation and a emission of gas the odour must be noticed at a gas concentration which will not cause danger. It is required that the odour can be noticed at every point of the grid. Therefore a threshold of the concentration of the odourant is defined. It has to be checked periodically whether the concentration at the end points of the grid is sufficient. The amount of odourant dosed in the outlet of the gas pressure regulating station is chosen to meet the required threshold. The operability of the equipment for the odourisation has to be monitored. The procedures are described in DVGW G 280-1 [3]. The customers are asked to inform the gas supplier immediately in case they notice the odour. An on-call service, which is available 24 hours a day, ensures that action is taken immediately.

3.3 Testing of the service line and the gas installation prior to commissioning The service line (including the pipeline up to the regulator) must have undergone pressure testing prior to commissioning. The test pressure must exceed the design pressure by a minimum of 2 bars [1], e.g. a service line designed for a pressure of 4 bars is tested with 6 bars. The main shut-off device, the regulator and its safety features must have been tested concerning leak tightness and functional ability. New pipes of the gas installation are pressure tested with a pressure of 1 bar. Afterwards the complete installation, including valves, fittings and when required the meter are tested concerning leak tightness with a pressure of 110 mbar [4]. Requirements from DVGW exist for each component used in the service line, e.g. pipes, fittings, meters, regulators The requirements contain both an approval of the component and its construction - regarding operability and durability - and demands concerning the quality assurance. 4 Limitation of damage and defence against manipulation 4.1 Excess flow valve outside (to guard the service line) An excess flow valve is installed directly at the beginning of the service line. It closes when the flow rate in the service pipe exceeds a certain limit. Thus the flow is cut off in case of third party damage of the service line, for example. Thereby a hazard caused by uncontrolled gas exhaust due to a damage of the pipe is prohibited. For dimensioning the excess flow valves the gas flow rate is the crucial factor. Different types of excess flow valves are available both concerning the construction, the way of installation and special features. One of them is that the excess flow valves reopens, but only when the outlet pressure is built up which can only occur when there are no openings behind. The requirements for the excess flow valves are described in DVGW VP 305-2 [5], which also contains a brief description of the different types. New developments are expected. 4.2 Excess flow valve inside (to guard installation) Another excess flow valve is installed directly after the main shut-off device or inside the regulator. It closes when the flow rate in the installation exceeds a certain limit. If necessary, additional excess flow valves may be installed to guard further distribution pipes inside the house. Uncontrolled gas exhaust in case of manipulation is prohibited, e.g. an unauthorised intrusion to steel gas. The requirements of these excess flow valves are given in DVGW VP 305-1 [6]. 4.3 Requirements of the residential service gas entry device (GED) The GED connects the service line and the installation. It is installed in such a way that forces which may arise outside the house, for example caused by an attack on the service line, have no effect on the installation. Thus third party damage cannot lead to an exhaust of gas inside the house. This is achieved by an anchor point inside the wall or a protection against pull out [7]. 4.4 Safety features of the regulator A safety shut off valve (SSV) inside the regulator closes when the outlet pressure rises above a preset value. Thereby it is prohibited that the pressure in the installation exceeds a value which might cause damage. The SSV can only be reset manually.

The regulator can also be supplied with a low pressure cut off feature. It closes, when the outlet pressure falls below a preset value. This might be either due to a drop of the inlet pressure caused by a defect of the grid or a drop of the outlet pressure caused by a defect of the installation. The low pressure cut off feature reopens only when the outlet pressure is built up which can only occur when there are no openings in the installation [8]. The safety features have to be checked prior to commissioning and periodically [9]. 4.5 High temperature resistance All devices inside the house must be resistant against high temperatures. In case of fire an exhaust of gas is prohibited at least for a certain time. Thus explosions or an enhancement of the fire can be prevented. The devices must be leak-proof for 30 minutes at a temperature of 650 C. 4.6 Main shut-off device An easily accessible shut-off device is installed at the end of the service line, mostly directly after the GED. It could also be installed in a connexion box outside the house. In a case of danger the gas flow can be shut off without excavation.

References [1] DVGW G 459-1 (07.1998) Gas service pipes for operating pressures up to 4bar - Design and construction [2] DVGW G65-1 (11.1997) Supervision of gas pipeline systems with an operating pressure up to 4 bar [3] DVGW G 280-1 (08.2004) Gaodorierung (Odourisation of gas) [4] DVGW G 600 (08.1996) Technical specifications for gas installations -DVGW-TRGI 1986/1996 [5] DVGW VP 305-2 (05.2003) Excess Gasströmungswächter für Gasversorgungsleitungen (Excess flow valves for gas supply lines) [6] DVGW VP 305-1 (12.2002) Gasströmungswächter für die Inneninstallation (Excess flow valves for gasinstallation) [7] DVGW VP 601 (10.2000) Service entries for gas and water supply [8] DVGW VP 200 (11.2004) Gas-Druckregelgeräte und Sicherheitseinrichtungen der Gas-Installation für Eingangsdrücke bis 5 bar (Gas regulators and safety features of the gas installation for inlet pressures up to 5 bars) [9] DVGW G 495 (11.1994) Gas installations - Maintenance List of Tables Table 1: Minimum period of survey List of Figures Figure 1: A typical German construction of the service line and installation