ph measuring system for hygienic process applications

Similar documents
Armatures for analytical probes

Sanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Pneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas

Pneumatic retractable fitting for simple commercially available control units or process applications

Pressure Transmitters 36 F-27839

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Pressure Transmitter P41

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Technical Information Conducal CLY421

JUMO dtrans p30 Pressure Transmitter

Manual retractable fitting with safe-to-operate rotary drive

Mass Flow Controller (MFC) for Gases

Overview. VARICOVER product recovery systems. Special features. Recover the value, reduce the waste! Design with no dead-zones.

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure Measurement Single-range transmitters for general applications

STERILIZABLE DISSOLVED OXYGEN SENSORS

High-performance submersible pressure transmitter For level measurement Model LH-10

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Pressure Reducing Valve DMV 755

Expansion Thermometers Stainless Steel Series, Model 70

Installation, operating and maintenance Instructions for Seemag bypass level indicator

SPD310/SPD360 Air Differential

Expert Hydrostatic Level Transmitters

Oxymax H COS21D. Technical Information

Mass Flow Controller (MFC) for Gases

OPTIBAR P 1010 C Technical Datasheet

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Technical Information Cleanfit CUA451

deltaflowc deltaflowc Venturi or Probe

Mass Flow Meter (MFM) for Gases

Pressure Measurement Single-range transmitters for general applications

High-performance submersible pressure transmitter For level measurement Model LH-20

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER

ATS430 turbidity sensor Retractable insertion assembly

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

11. Spare Parts. applications since applications since

General Specifications

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

Operating instructions - Translation of the original -

Types and approvals. Page 1/6. Data Sheet

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Technical Data Sheet MF010-O-LC

L3 Pressure and Level transmitter

Gas density monitor With integrated transmitter Model GDM-100-TI

Operating instructions Binary level sensor LI / / 2013

SITRANS P measuring instruments for pressure

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

BS12N Piezoresistive OEM Pressure Sensor

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Model PDT Dewpoint Transmitter

Differential Pressure Transmiter

Climatic Independent Level Sensor LAR

HI 2314 HI 2315 HI 23151

BS12 Piezoresistive OEM Pressure Sensor

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Instruction Manual Contact Pressure Vacuum Gauge

Quick Start Guide LIQ-QSG-499ACL-03, Rev I July Rosemount 499ACL-03. Monochloramine Sensor

14. Exploded View. Page 68

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

4/2 way Pneumatic Solenoid Valve

ED 701 Hygenic Pressure Transmitter

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

ELADOS EDP L Diaphragm Metering Pump Type

Operating instructions - Translation of the original -

Type BBS-03, BBS-05, BBS-06, BBS-25

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

MPM280 Piezoresistive OEM Pressure Sensor

Pressure Reducing Valve DMV 750 set range: bar

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Operating instructions - Translation of the original -

AMS 2710 PCB pressure sensor module with V output

High-performance submersible pressure transmitter For level measurement Model LH-20

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34

0349/MaN. Satron Pasve and Pasve ph

Pressure reduction controller (PN 16, 25, 40)

INSTRUCTION MANUAL Pressure Relief Device LPT

Installation and Operating Instructions Bypass Flow Meter DST

Bourdon tube pressure gauges for chemical applications EN 837-1

C-Flow Coriolis Mass Flow Meters

Transcription:

ph measuring system for hygienic process applications Sterile design, CIP-compatible, in-line sterilizable Extremely robust and unbreakable construction Extremely long service life Long calibration intervals Especially suitable when preparing foods and drinks Type 8201 can be combined with... Type 8201 DN25, DN30 Type 8201 Adaptation sets for fittings Type 8201 Type 8200 ph armature Type 8201 Adaptation set for armature Type 8200 Type 8619 multicell transmitter/controller The 8201 is suitable for measuring absolute ph values in liquids between ph 0 and ph 12 at medium temperatures of up to 140 C and process pressures of max. 6 bar. Due to its hygienic design and the robust glass-free layout, this model is particularly suitable for use in hygienic processes. An example would be the production of foods and active ingredients, during which the ph value of liquid mediums - including those which are viscous or contain solids - is measured. The ph probe's extremely smooth enamel surface inhibits the medium from sticking and is very easy to clean inline. Due to its robust design and high temperature and chemical tolerance, the probe stays in the process even during a CIP purification. This means that expensive retractable fittings can be dispensed with. Temperature C 200 160 120 80 40 not consistent consistent mm Attack/Year 0 2 4 6 8 10 12 ph value 0.1 Technical data - Probe Measuring value Reference system Measuring range Measuring error Measuring chain zero point Measuring chain isotherm point Slope Ambient temperature Medium temperature Minimal conductivity Thermoshock resistance Medium pressure Temperature compensation Materials Wetted part Signal outputs Electrical connection Protection type Absolute ph Machined diaphragm (ceramic enamelled), reference electrode Ag/AgCI, KCI electrolyte 3-molar sterile 0 to 10 ph (for up to 12 ph see diagram) Depending on calibration max. 0.01 ph 8.65 ±1 ph* 1.0 ±1 ph; Uis= 440 mv* 56-59 mv/ph* at 25 C (77 F) 0 to +50 C (32 to 122 F) 0 to +140 C (32 to 284 F) 1 S T = 120 C (248 F) -1 to 6 bar rel. (-14 to 87 PSI) Pt1000 Probe head PVDF Enamelled steel pipe, ceramic enamelled ground diaphragm, 1.4404 process connection and EPDM seal Pt1000 2-wire, ph value in mv 6-pin gold-plated IP68 Adaptation set For ph armatures Type 8200 or Type 8201 For flange connection adapted for GEA Tuchenhagen VARINLINE process connection (DN50-DN125; EHEDG) or for Clamp 2 Suitable transmitters Hygienic connection fittings 8201 ph armature Type 8200 * For exact values see probe test report Devices with isotherm option Weld connection DN25 (Ingold welding nozzle), Weld connection DN30 (EHEDG), other on request Stainless steel connecting pieces 1.4404 Only stainless steel versions possible. For dimensions see data sheet Type 8200

Measuring principle The ph sensor works as a single-rod measuring cell. The measuring electrode and reference electrode are combined in one element. An enamelled steel pipe is used as the basic carrier. The measuring electrode is created by additionally attaching an ion-sensitive enamel layer (yellow) with metallic voltage conductor (positioned in the non-conductive blue enamel carrier layer). An ion exchange of H+ions and alkali ions takes place on the surface (gel layer) of this enamel layer. The Ag/AgCI reference electrode is located in the interior of the enamel pipe filled with electrolyte. A ceramic machined diaphragm is pressed into the lower end of the pipe. Voltage transfer takes place when the electrolyte makes contact with the measuring solution via the annular gap of the diaphragm. A Pt1000 for temperature compensation is also integrated in the sensor. The electrolyte used is 3-molar KCI, stored in a separate electrolyte vessel and permanently connected to the probe via a hose. The pressure of the electrolyte vessel is maintained slightly above process pressure by means of an attached pressure controller. For non-pressurised processes the static overpressure of the pressure vessel mounted approx. 0.5 m above the probe is generally sufficient. Due to the very slight permanent electrolyte flow that flows through the extremely small annular gap, contamination of the reference electrode is practically eliminated. Accidental operation without electrolyte is prevented by optional inductive level monitoring of the pressure container. When a minimum level has been reached, the electrolyte supply bottle in the pressure container is simply changed. Bürkert Type 8285 provides the analysis of the measured value. The maximum length of cable between probe and converter (transmitter) should not exceed 5 m. ph probe 8201 is supplied without adaptation. The appropriate set is selected according to the fitting/armature chosen. Different hygienic variations of Model 8201 are available. Various standard armatures Type 8200 can be used as well. Structure The complete measuring system consists of the ph probe, an adaptation set, an attachment fitting, the reservoir with hose for the electrolyte solution, the electrolyte solution and the electric cable for connecting to a suitable transmitter. The ph probe 8201 is supplied without adaptation. According to the chosen fitting/armature the appropriate adaptation set has to be selected. Different hygienic fittings (Type 8201) or for general purpose applications ph armatures of Type 8200 can be selected. Installation Intended performance is limited to proper installation of the fitting (by weld), integrating the probe into the process using the appropriate adaptation kit, proper mounting of the electrolyte vessel electrolyte attachment perpendicularly downwards close to the measuring point and connecting the ph sensor and electrolyte vessel using the hose connection supplied. The electrolyte supply bottle is inserted into the electrolyte vessel and the ph sensor filled with electrolyte by opening the ventilation screw. You are free to choose the assembly position of the ph sensor. During operation care must be taken that the active surface (length approx. 45 mm from probes lower edge) is completely surrounded by medium. The flow velocity should not exceed 3 to 4 m/s. Dry-storage of the ph sensor is unrestricted. The probe is connected to the transmitter by means of the attachment cable. Inductive level switch is attached to a suitable analyzing device. ph-sensor Reference electrode Solution ground Probe body ground Cable protection Pt1000 Pt1000 transparent red blue grey green/yellow white green Cable allocation, connection cable for transmitter

Dimensions [mm] ph probe enamel without adaptation ph probe with adaptation set PG13.5 for ph armature Type 8200 Electrolyte vessel with built-in electrolyte supply bottle Ultrasonic level switch with M12 connector Fastening holes M4, depth 8 ph probe with adaptation set for flange connection adapted for GEA Tuchenhagen VARIN- LINE process connection (DN50-DN125; EHEDG) ph probe with adaptation set Clamp 2 external ø64 mm ph probe with adaptation set DN30 (EHEDG) ph probe with adaptation set DN25 Note: Housing and O-ring ø 60 not included in delivery O-ring ø 60 Fittings Type 8201 Welding tab DN30 EHEDG Welding tab DN25 sloped Welding tab DN25 straight Blind plug for welding tab DN30 EHEDG nut for blind plug (welding tab DN30 EHEDG)

Ordering chart A complete Model 8201 contains the following components: ph probe enamel Suitable adaptation set for fitting/armature Fitting/armature Electrolyte vessel (electrolyte hose included) Supply bottle with 1 litre electrolyte KCI Connection cable for transmitter Transmitter Type 8285 (see data sheet Type 8285) Note: The cable between probe and transmitter must categorically be selected as short as possible particularly at low process temperatures in order to guarantee measurement signal dynamics that are as high as possible. A cable length of 10 m should only be used in exceptional cases. If required, to disinfect and rinse the system you will need: Demineralized water, 1 Litre plastic bottle Plastic bottle with septum for alcohol filling All necessary parts have to be ordered separately Description ph measuring range Medium temp. Pressure (rel.) Electrical connection Item no. Probe ph probe-enamel without adaptation 0 to 10 (12) 0 to +140 C -1 to 6 bar 6-pin gold-plated 554 849 Description Comment Item no. Adaptation sets Adaptation set for welding tab DN25 Type 8201 Union nut G 1¼" / DN25 554 866 Adaptation set for welding tab DN30 (EHEDG) Type 8201 Union nut G 1¼" / DN30 554 873 Adaptation set PG13.5 for ph armature Type 8200 PG13.5 with O-ring 554 862 Adaptation set for flange connection adapted for GEA Tuchenhagen VARINLINE process connection (DN50-DN125; EHEDG) Flange adapted for GEA Tuchenhagen VARINLINE process connection 558 617 Adaptation set Clamp 2 external ø64 mm Clamp 2 559 744 Electrolyte vessel Electrolyte vessel, stainless steel incl. electrolyte hose set 5 m, 554 850 Electrolyte vessel, stainless steel, with level switch compressed air attachment, pipe / wall-mounting unit 1 554 851 Operating liquids Electrolyte KCI, sterilised, 1 litre plastic bottle Electrolyte reference system 554 852 Water demineralised, 1 litre plastic bottle For rinsing the system 554 853 Plastic bottle with septum For self-filling with alcohol 70% vol. 554 854 Connection cables Connection cable for ph probe enamel, 3 m long 6-pole Variopin coupling on ph probe, 554 855 Connection cable for ph probe enamel, 5 m long flexes on transmitter 554 856 Connection cable for ph probe enamel, 10 m long * 554 857 Fittings Type 8201 attachment cables Welding tab DN25, 40 mm, straight, 1.4404 DN25/weld attachment straight 554 858 Welding tab DN25, 40 mm, sloped, 1.4404 DN25/weld attachment diagonal 554 859 Welding tab EHEDG, DN30, 60 mm, straight, 1.4404 DN30/weld attachment straight 554 860 Blind plug for welding tab EHEDG, DN30, 1.4404 ** Union nut G 1¼ / DN30 554 861 Nut for blind plug for welding tab EHEDG, DN30, 1.4404 ** G 1¼ / DN30 554 872 * Only to be used in exceptional cases, please consult your Bürkert application specialist for application advice. ** Absolutely necessary in order to prevent warping when welding EHEDG DN30 connecting pieces.

Ordering chart, inspection and retrofit sets The maintenance sets contain small parts such as O-rings, seals, stainless steel canulas, flexible tubing, couplings etc. The retrofit sets contain all parts needed for mounting / dismantling a level switch. Description Contents Item no. Maintenance sets Inspection set for ph probe enamel 2 O-rings 10 x 2.5 mm EPDM, 2 O-rings 20 x 2.5 mm silicon, 2 O-rings 23.39 x 3.53 mm EPDM, 4 items adaptor reinforcement ring PTFE 554 876 Flexible tube set 1 hose connection, 1 hose connector, PTFE hose 4 x 1 length 5 m 554 883 Retrofit sets Level switch cplg. Ultrasonic level switch with M12 fixed connector 561 533 Locking screw M12 x 1 cplg. Locking screw PVDF with O-ring FKM 554 887 Please use the attached application questionnaire to describe your process and send it to your Bürkert office to check the suitability. Please complete all three pages.

Questionnaire applications with the enamel ph probe Type 8201 Please fill in and send to your local Bürkert Sales Centre*. Company: Contact person: Customer No.: Department: Address: Tel. / Fax.: Postcode / Town: E-mail: Our process Process description: continuously ph regulation continuously ph control Temperature range * from to [ C] Pressure range * from to [bar] ph range * from to [bar] Concentration of dissolved substances Molarity [mol] or proportion [%] which substances variable concentration no yes if yes, please quotate the variation [mol] Cleaning process ** Conc. Temp. Time ph value mol C minutes ph Cleaning with base Cleaning with acid Sterilisation with steam Sterilisation with product Sterilisation with aseptic solutions Other cleaning * Please chart this data into the diagram time lapse of the process at page 7. ** Please chart this data into the diagram time lapse of the cleaning process at page 8. Currently used measuring Used type of : Following issues are existing:

Process time lapse [ms/cm] [ph] [bar] [ C] 10 4 14 13 175 13 12 10 3 12 11 150 11 10 10 2 10 9 125 9 8 10 8 7 100 7 6 1 6 5 75 5 4 10-1 4 3 50 3 2 10-2 2 1 25 1 0 10-3 0-1 0 time [ ] Remarks:

Cleaning time lapse [ms/cm] [ph] [bar] [ C] 10 4 14 13 175 13 12 10 3 12 11 150 11 10 10 2 10 9 125 9 8 10 8 7 100 7 6 1 6 5 75 5 4 10-1 4 3 50 3 2 10-2 2 1 25 1 0 10-3 0-1 0 time [ ] Remarks: