Manual Crane Scale PCE-CS 300

Similar documents
Manual Refractometer PCE-ALK

SAUTER FK Version /2016 GB

03/07/2014 V

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

M S I C R A N E S C A L E

Operating instructions IMMOOS Rescue Carriage Type C Type C+ 2 rollers

Calibration Procedure

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Manufactured by: AAA

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300

User Instructions 1789 Parapet Wall Anchor

Instructions for Use Wire Rope Hoist SAT 08 / SAT 16 / SAT 32

RAM 4021 Operation Manual

testo Leakage detector for refrigerants Instruction manual

GAS FUEL VALVE FORM AGV5 OM 8-03

Edge Isolation Tool. Standard Operating Procedure. Version 1.1. Date: Prepared by, Sandeep S S. Department of Electrical Engineering

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

MP15 Jockey Pump Controller

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

Heavy Duty Dissolved Oxygen Meter

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Digital Ear Thermometer

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

ATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502

Triple Tine Mechanical Grapple

New AQF Filter Polymer Filtration System

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no

Overspeed governors (113 OG Моment 250 MR, 114 OG Moment 250 A3, 115 OG Moment 250 MRL, 119 OG Moment 250 MRL/1)

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Manual. Kingpad mc-32 Edition. Bus system control pad for installation in the Graupner mc-32 transmitter. No Copyright Graupner/SJ GmbH

OPERATIONS MANUAL RIGHT ANGLE CAPSTAN

Short manual testo

GasLab SAN-102 Micro Oxygen Monitor User Manual

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

AUTOMATIC FILM APPLICATOR MICROPROCESSOR CONTROLLED. Operating Instructions for the

American Weigh Scales, Inc. LB User Manual

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

WARNING: EXPLOSION HAZARD

Lockout Tagout Policy

Multifunction Altimeter/Variometer AV1

User Manual. GPL 3000 e. gas detector

Digital Melting Point Apparatus

Instruction Manual Contact Pressure Vacuum Gauge

HEALTH AND SAFETY MANUAL

Operators & Maintenance Manual OPERATOR S MANUAL USAGE AND MAINTENANCE F100M F100M. Powered Fixed Hoist Ideal for raised swimming pools and hot tubs

Operation Manual ARTICEL SunSun CUF SunSun CUF SunSun CUF-6000

Installation and Maintenance Instruction Manual

Instruction Manual Dräger MSI P7 and MSI P7 plus

DIVER NAVIGATION BOARD. RJE International, Inc. RJE International Feb 1, TAC-100D Revision 10

Instruction Manual EMA 84 Digital Pressure Gauge

6 digital caliper with case

ATOM-X 2. User Manual

MECHANIC QUALIFICATION

Operating Manual Body fat balance

slide takedown lever magazine release

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Cygnus Instruments Ltd

LM6 LEATHER MOISTURE METER

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

RGC-IR Remote Gas Calibrator for IR400

Instruction Manual Differential Pressure Transmitter

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

We measure it. For gas and water installers. testo hpa. bar

P+P Retractable Type Fall Arrester PK6S

Pneumatic high-pressure controller Model CPC7000

ESSENTIAL SAFETY RESOURCES

Oxford. Manufacturer s Contact Details. Contents. Oxford Low Profile Weigh Scale. English

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

RAM 4021-DPX Operation Manual

Elcometer ISO Groove Depth Checker. Operating Instructions

User Instruction Manual For Davit Rescue System

TEMPERATURE GRADIENT PLATE MFFT 10 / MFFT 20 VF9700 / VF9600

Pedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX

S/Y MORSKI ZEKAN TECHNICAL INFORMATION

USER MANUAL. MACMAG magnetic separator MHK MHF

testo 511 Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Manual de instruções

trigger magazine release

On the Go Swing System Instruction Manual

Savard Labor & Marine Staffing, Inc. Compressed Gas Safety Program Rev3/14

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Adam Equipment. DENSITY DETERMINATION KIT for AAA, ADA and ADP SERIES BALANCES OPERATOR S MANUAL

Name of product: Gripper of FTV panels for horizontal façades Types: PHF (60, 80, 100, 120, 133, 150, 172,200, 240) INSTRUCTIONS FOR USE

THE UNIVENTOR 400 ANAESTHESIA UNIT

Instruction Manual: VelectriX Ascent 29 MTB

Operating Instructions - Rescue Equipment. RAM Support LRS-T EN Edition (translation of the original operating instructions)

For ELECTRIC ANCHOR WINCH Models: T Pontoon 35 T sw Salt Water Series Coastal 35

Suitable for anyone who is required to maintain industrial pneumatic systems. No prior knowledge of pneumatic or electrical principles is necessary.

Figure 1 - Parts Identification. Copyright 2002, DB Industries, Inc.

Manual PT1000/1500/2000 personnel/material elevator printdate: versie 1.1 INTRODUCTION... 2

BAR END BAR END BRAKE LEVERS BRAKE LEVERS

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IMPORTANT: Record the product identification information from the ID label in the inspection and maintenance log in section 9.0 of this manual.

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

PosiTector UTG, UTG-STD & UTG-ME

Transcription:

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign way Hampshire / Southampton United Kingdom, SO31 4RF From outside UK: +44 Tel: (0) 2380 98703 0 Fax: (0) 2380 98703 9 info@pce-instruments.com www.pce-instruments.com/english www.pce-instruments.com Manual Crane Scale PCE-CS 300 Version 1.0 03.09.2014

CAUTION: Safety Information Since the elevation of loads might involve some hazards, the manufacturer and operator should consider some precautious measures. The operation with the measuring device should never lead to hazardous situations. The person that is in-charge of the device and any operator must follow any national guidelines, e.g. accident prevention regulations, safety regulations, standard operation procedures and any other regulations that are relevant in terms of operation with the device. There are also further guidelines, standards and safety regulations that must be considered regarding this device, e.g. those of the manufacturer of the crane, manufacturer of the scale, manufacturer of the shackle etc. Thus the montage, initiation, maintenance and operation of the device is only permitted for a person with special training and with the accordant safety equipment. The measuring device cannot be alternated and must be applied only for the accordant applications. The device and all the involved equipment (e.g. the crane, the load suspension means etc.) must run through regular maintenance, which must be protocolled. At least a thorough visual inspection should be performed prior to every operation. In case the system is incomplete or if there are any damages (e.g. fractures, deformation, chippings etc.) any further operation of the device must be blocked immediately. Therefore you should consult the safety delegate in your company. Any kind of repairs should be performed by trained personnel. Therefore only tested repair parts should be used. All repairs, any maintenance and integrated replacement parts must be documented by the partnered service. The instruction manual as well as the safety precautions should be always placed in reach near the device. The device is not Ex- proved. Thus it should not be installed within the reach of explosive hazardous locations. The surrounding conditions, e.g. temperature ranges, can be read in the instruction manual. Aggressive application ranges, for example locations that are hazardous for corrosion should be avoided. In case of larger temperature fluctuations an acclimation period should be considered. The measuring device is only allowed for the elevation and weighing of maneuverable load. A contortion of the load (rotational tension) must be avoided. Carrying persons, diagonal pulling, tearing and towing of the load is forbidden. The permitted nominal load [MAX] of the measured good and all the equipment involved in the measuring process (e.g. crane, load suspension means etc.) cannot be trespassed in any case. During the operation of the device, all potential hazardous situations should be considered. During operation avoid standing within the hazardous area. This might not only be the area right underneath the elevated load, but also areas that might become hazardous, for example due to deflecting ropes or other equipment after snapping off..

Maintenance and Control Inspection prior to each operation with the device An inspection of the device must be performed prior to the initiation of the operation. The operator must check the following aspects: - There should be no visible deformation or damages, e.g. fractures. - All compartments and attaching parts should be complete and in a flawless condition (e.g. safety splints etc.) - The entire system must be installed neatly so that there is no potential hazard (e.g. due to faulty montage) - That the surrounding environment should clear from any hazards, and if there is some potential left, accordant counteractions must be taken. Regular inspection / maintenance Every three months or after 12,500 measurements Every 12 months or after 50,000 measurements Avery 5 years or after 250,000 measurements Every 10 years or after 500,000 measurements - Control level of abrasion on attaching parts. - Control all dimensions. - Check on every possible deformation and damages. - Assure an accordant operation of all parts. - Check all parts that carry the load e.g. on hairline cracks etc. The maintenance should be performed by specialised personnel. - All parts that carry the load must be replaced. - Life time of measuring device is fully consumed. The entire measuring device must be replaced. Only the owner or operator takes responsibility for material damage and physical injuries resulting from improper application or violation of the guidelines. The manufacturer does not assume any liability. The safety measures are only an extract from effective standards and guidelines, containing several notes and advices. Those do not substitute these guidelines and standards, rather than facilitating as a courtesy for a safe operation of the device. Please familiarize yourself with the effective standards and guidelines in your country prior to the operation.

Control elements of the scale - Turn scale on and off - Turn on the scale after it went into an automatic shut-down after 30 minutes. - Turns the scale off (important: this mode leads to higher power consumption (approx. 30 ma), therefore we recommend to use the red button at the back of the scale to turn off the scale) - Adjustment of resolution (0.10 or 0.05) - tare function - Infrared interface Control elements of remote control - Turn off the device (Important: this mode leads to higher power consumption (approx. 30 ma), therefore we recommend to use the red button at the back of the scale to turn off the scale). - facilitates adjusting the resolution (0.10 or 0.05) - tares the scale - Key is not occupied.

Calibration mode Never perform a calibration without calibration weights. 1. Turn off the scale. 2. Remove all weights from the scale, so that the scale is unloaded. 3. Keep the key pressed and turn on the scale. 4. Now release the button and the display should show SPEN now. 5. Press the button again briefly. The display will now show SET and then 00000. 6. Now set the weight on same value as your calibration weight, by choosing values with the button and jumping to next digit left to the prior by pressing the 7. Press again briefly the button, to save value. 8. The scale will then automatically switch to the normal weighing mode. Settings in internal menu 1. Turn on the scale button. 2. While the scale plays a countdown from 9 to 0 on its display, briefly press. 3. Now the display will indicate bee 0. 4. With you can switch the acoustic signal for stabilized values on ( 1 ) or off ( 0 ). 5. Confirm with. 6. Now the display will indicate CHt 0. With you can now chose the unit. 7. Press again to confirm. 8. Now the display will indicate Aut 0. Here you can either turn off the background lights ( 0 ) or switch to Automatic mode ( 1 ). Disposal Batteries may not be put in the household waste. They have to be given in the set up collection points. Please contact PCE Instruments if you have any questions concerning our products, service etc. WEEE.-Reg. Nr.: DE69278128