PRODUCT CONFORMITY CERTIFICATE

Similar documents
Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ20 oxygen monitor Combustion gas analysis

Zirconia Oxygen Analyzer Systems

Autocalibration Systems For In Situ Oxygen Analyzers

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Service Calibration are you doing it properly?

Pneumatic high-pressure controller Model CPC7000

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Technical Paper. Selection of Particulate Monitors. Author: William Averdieck, PCME Ltd

Pneumatic high-pressure controller Model CPC7000

Digital dead-weight tester Model CPD8500

Laser Gas Analyzer LG2000. The Laser Technologies

Autocalibration Systems for In Situ Oxygen Analyzers

High-performance submersible pressure transmitter For level measurement Model LH-20

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

High-performance submersible pressure transmitter For level measurement Model LH-20

Digital pressure gauge Model CPG500

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ30 Combustion oxygen monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

Supplementary Certificate of Approval. No S433

How to specify a product. Process Sensors and Mechanical Instruments

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

CONTENTS OVERVIEWS PRODUCT INFORMATION

Hovacal DATASHEET JUNHO 2013

Digital pressure gauge Model CPG500

Precision pressure sensor Basic version Model CPT6020

Navigator 500 Dissolved oxygen analyzer. Measurement made easy. Accurate and reliable measurement of dissolved oxygen in high purity water

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Hand-held pressure calibrator with integrated pump Model CPH6600

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Digital deadweight tester Model CPD8500

High-performance submersible pressure transmitter For level measurement Model LH-10

Endura AZ30 series probe Combustion oxygen monitor. Proven technology for use in hazardous area gases and dusts

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas monitoring using GASMET FTIR

Best Practice Guide, Servomex 2700

Technical Data Sheet MF010-O-LC

Precision digital pressure gauge Model CPG1000

FTC130 Transmitter. Operating Manual

Endura AZ25 series probe Combustion oxygen monitor

deltaflowc deltaflowc Venturi or Probe

Model EXAxt AV550G. Averaging Oxygen Analyzer

780S Ultra High Purity Series

Features. Description

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Instruction and Maintenance Manual

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Ultrasonic level transmitter and indicator

analytical bulk flow distance FLOW level pressure temperature industrial communication

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Micro Motion 3098 Gas Specific Gravity Meter

High-performance submersible pressure transmitter For level measurement Model LH-10

WBEA Standard Operating Procedure

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

9700 Transmitter Submersible hydrostatic level transmitter

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

CONTROL and INSTRUMENTATION

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

High-speed pressure sensor Model CPT6140

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Service ISO17025 explained

FLAMMABLE GAS SENSOR/TRANSMITTER

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

GasSense NDIR User Manual

Programmable Submersible Level Transmitters

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Continuous Gas Analysis ULTRAMAT 23 Supplement 1 for Operating Instructions C79000-G52xx-C Product Information

EasyLine Continuous Gas Analyzers. So smart, they re simple

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Instruction Manual Differential Pressure Transmitter

User Manual PTW-DensiX. D / Di/Zi

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Electronic gas volume corrector model DGVC-04

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Programmable pressure and temperature transmitters PTM/RS485

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Technical Information Conducal CLY421

Navigator 600 Silica analyzers

ABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators

AK100 Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators

Industrial pressure controller Model CPC4000

Automatic Isokinetic Sampler. ST5 Evo

Transcription:

PRODUCT CONFORMITY CERTIFICATE This is to certify that the Endura AZ20 / AZ30 measuring system Manufactured by: ABB Ltd Oldends Lane Stonehouse Gloucestershire GL10 3TA has been assessed by Sira Certification Service And for the conditions stated on this certificate complies with: MCERTS Performance Standards for Continuous Emission Monitoring Systems, Version 3.5 dated June 2016 EN15267-1:2009, EN15267-2:2009, EN15267-3:2007, & QAL 1 as defined in EN 14181: 2014 O 2 Certification Ranges : 0 to 25%vol 0 to 5%vol Project No.: 70102656 Certificate No: Initial Certification: 22 November 2011 This Certificate issued: 22 November 2016 Emily Alexander Renewal Date: 21 November 2021 Deputy Certification Manager MCERTS is operated on behalf of the Environment Agency by Sira Certification Service Unit 6, Hawarden Industrial Park Hawarden, Deeside, CH5 3US Tel: +44 (0)1244 670 900 The MCERTS certificate consists of this document in its entirety. For conditions of use, please consider all the information within. Page 1 of 7

Certificate Contents Approved Site Application... 2 Basis of Certification... 2 Product Certified... 3 Certified Performance... 4 Description... 7 General Notes... 7 Approved Site Application Any potential user should ensure, in consultation with the manufacturer, that the monitoring system is suitable for the intended application. For general guidance on monitoring techniques refer to the Environment Agency Monitoring Technical Guidance Notes available at www.mcerts.net On the basis of the assessment and the ranges required for compliance with EU Directives this instrument is considered suitable for use on waste incineration and large coal-fired combustion plant applications. This CEM has been proven suitable for its measuring task (parameter and composition of the flue gas) by use of the QAL 1 procedure specified in EN14181, for IED Chapter III and IED Chapter IV applications for the ranges specified. The lowest certified range for each determinand shall not be more than 1.5X the daily average emission limit value (ELV) for IED Chapter IV applications, and not more than 2.5X the ELV for IED Chapter III and other types of application. Basis of Certification This certification is based on the following Test Report(s) and on Sira s assessment and ongoing surveillance of the product and the manufacturing process: TUV Rheinland Report Number 936/21213673/A dated 10 October 2011 ABB witness test report Report Number 16A32433 dated 7 November 2013 Page 2 of 7

Product Certified The measuring system consists of the following parts: AZ20 - AZ20/ coded version of the standard probe with integrated measuring transmitter (type 211111327110GSTD tested) OR - AZ20/ coded version of the standard probe with external measuring transmitter (type 212112327112GSTD tested) AZ30 - AZ30/ coded version of the standard probe with integrated measuring transmitter OR - AZ30/ coded version of the standard probe with external measuring transmitter This certificate applies to all AZ20 instruments fitted with software version 2000.01.15 and above with measuring transmitter serial number 3K220000048374 onwards. This certificate applies to all AZ30 instruments fitted with software version 2000.01.15 and above with measuring transmitter serial number 3K220000196958 onwards. Page 3 of 7

Certified Performance The instrument was evaluated for use under the following conditions: Ambient Temperature Range: Instrument IP rating: -20 C to +50 C IP66 Note: If the instrument is supplied with an enclosure then the ambient temperature shall be monitored inside the enclosure to ensure that it stays within the above ambient temperature range. Unless otherwise stated the evaluation was carried out on the AZ20 for the certification range O2 0 to 25%vol. Both integrated and external measuring transmitter tested, worst result recorded. Test Results expressed as %vol Other results MCERTS specification <0.5 <1 <2 <5 Response time AZ20 AZ30 O2 (dry gas) (0 to 25%vol) 12s <200s O2 (wet gas) (0 to 25%vol) 17s <200s O2 (dry gas) (0 to 5%vol) 32s <200s O2 (wet gas) (0 to 5%vol) 18s <200s O2 (dry gas) (1 to 21%vol) 16s <200s O2 (wet gas) (1 to 21%vol) 20s <200s Repeatability standard deviation at zero point O2 0.01 <0.2% Repeatability standard deviation at reference point Lack-of-fit O2 0.07 <0.2% O2 (0 to 25%vol) 0.09 <0.2% O2 (0 to 5%vol) 0.03 <0.2% Page 4 of 7

Test Results expressed as %vol Other results MCERTS specification <0.5 <1 <2 <5 Influence of ambient temperature zero point O2 0.04 <0.50% Influence of ambient temperature reference point O2 0.15 <0.50% Influence of sample gas pressure O2-0.20 <0.2% Influence of voltage variations 190 to 250V O2 0.06 <0.2% Influence of vibration at zero (10 to 60Hz (±0.3mm), 60 to 150Hz at 19.6m/s 2 ) Influence of vibration at reference (10 to 60Hz (±0.3mm), 60 to 150Hz at 19.6m/s 2 ) -0.11 To be reported -0.17 To be reported Cross-sensitivity at zero with interferents: H2O, CO, CO2, CH4, N2O, NO, NO2, NH3, SO2, HCl O2 0.00 <0.40% Cross-sensitivity at reference with interferents: H2O, CO, CO2, CH4, N2O, NO, NO2, NH3, SO2, HCl O2-0.23 <0.40% Measurement uncertainty Guidance - at least 25% below max permissible uncertainty O2 (Based on a range 25%vol) 2.6% 7.5% Calibration function (field) O2 0.98 >0.90 Response time (field) O2 15s <200s Page 5 of 7

Test Results expressed as %vol Other results MCERTS specification <0.5 <1 <2 <5 Lack of fit (field) O2 0.07 <0.2% Maintenance interval Zero and Span drift requirement Change in zero point over maintenance interval 4 weeks Note 1 The CEM tested was tested for zero and span drift manually. The Endura AZ20 & AZ30 are available with an optional attachment for automatic zero and span checks, although this option was not evaluated during the test programme Full Description and techniques are given in the ABB product manuals for calibration / compensation of zero drift. (See last page Description in this document for more information) >8 days Clause 6.13 & 10.13 Manufacturer shall provide a description of the technique to determine and compensate for zero and span drift. O2 0.16 <0.2% Change in reference point over maintenance interval O2 0.19 <0.2% Availability Reproducibility 99.4% >95% (>98% for O2) O2 0.19 <0.20% Note 1: Manufacturer instructions must be followed. Monthly maintenance works conducted during field trial: Visual check of the system test gas calibration check at zero and span point temperature check of the sensor oven check of reference air flow from pump or air supply Page 6 of 7

Description System equipment comprises a (process-mounted) Endura AZ20 or AZ30 oxygen probe, controlled by an integral or remote transmitter. During operation, a zirconia cell within the probe is held at a constant temperature of 700 C (1292 F) by a probe heater and control thermocouple assy. An output generated at the zirconia cell is processed in the transmitter to give a locally displayed O2 reading, and a self powered 4 to 20 ma retransmission signal with HART digital communications,( any range between 0 % and 100% O2.) AZ30 limited to 0% to 21% due to hazardous area certification Optional automatic calibration (AutoCal) enables automatic, semi-automatic or manual calibration to be performed using gas control solenoids mounted within the probe head. The gas calibration sequencing is software-controlled from the transmitter, and can be set to provide automatic or manual performance checking which does not alter any calibration coefficients, or, full calibration which resets the calibration coefficients, all results are logged for later reference. Optional restrictors in the probe head control the test gas and reference air flows, if restrictors are not fitted, flowmeters are required to set the correct test gas & reference air flows. The AZ20 probes are available in various mounting flange options and insertion lengths from 0.5 metre to 4.0 metre. All probes are capable operating in process temperatures from -20 C to 800 C. The AZ30 probes are available in various mounting flange options and insertion lengths from 0.5 metre to 2.0 metre. All probes are capable of operating in process temperatures from -20 C to 700 C. General Notes 1. This certificate is based upon the equipment tested. The Manufacturer is responsible for ensuring that on-going production complies with the standard(s) and performance criteria defined in this Certificate. The Manufacturer is required to maintain an approved quality management system controlling the manufacture of the certified product. Both the product and the quality management system shall be subject to regular surveillance according to Regulations Applicable to the Holders of Sira Certificates. The design of the product certified is defined in the Sira Design Schedule V00 for certificate No. 2. If certified product is found not to comply, Sira Certification Service should be notified immediately at the address shown on this certificate. 3. The Certification Marks that can be applied to the product or used in publicity material are defined in Regulations Applicable to the Holders of Sira Certificates. 4. This document remains the property of Sira and shall be returned when requested by the company. Page 7 of 7