Unisense In Situ UniAmp Connector System

Similar documents
OXYGEN MICROOPTODE - OPTO SERIES USER MANUAL

HYDROGEN SENSOR USER MANUAL

HYDROGEN SULFIDE SENSOR USER MANUAL

LogIT Dissolved Oxygen Probe

STERILIZABLE DISSOLVED OXYGEN SENSORS

Dissolved Oxygen Sensor

PH01 Perfusion Cannula Manual

Vinmetrica Dissolved Oxygen System User Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

1. A proper preparation of the cone and other material is inevitable prior to a CPTU test.

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

MAINTENANCE PROCEDURE FOR X 650

12mm Dissolved Oxygen Sensor Care and Use Instructions

OxyProbe II Instruction Manual

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

QUICK START GUIDE TO DRINKING WATER MONITORING

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Radnoti Liver Perfusion System

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

QUIK-jet Micro-Injection System

Research Grade Blood Pressure Transducer User's Manual

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

In situ permeability measurement with the BAT Permeameter. Quick Manual Ou low test. Warranty details

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

Free Chlorine Sensor For additional information, please visit our website at

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Pressure Injection Cell Operator s Manual

Non-Membrane Disinfection Sensors Instruction Manual

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

OWNER'S MANUAL. Copyright 1999 ATS - All Rights Reserved

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

BI-680 Online Dissolved Oxygen Controller Instruction Manual

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)

SDX Submersible Depth Transmitter User Manual

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

OWNER'S MANUAL. Copyright 2003 GAMMA - All Rights Reserved

Type BBS-03, BBS-05, BBS-06, BBS-25

PREPARATIONS FOR PIEZOCONE CPTU TESTING (De-airing and Saturating)

Safety instructions and operating manual

MODEL GT820 OXYGEN SENSOR

User Manual. ECC-Opto-Gas. Release Electrochemical test cell EL-CELL GmbH

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

TQC Bresle Chloride test 2008

EcoCell Vertical Electrophoresis Unit

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

In situ permeability measurement with the BAT Permeameter. Quick Manual Inflow test. Warranty details

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

ROPV R40 E Series User Manual

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

MECH-TECH SYSTEMS CCU MODEL FOR GLOCK PISTOLS

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

600 / 600FC OWNER'S MANUAL

WALL-MOUNT GARDEN HOSE REEL OWNER S MANUAL

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 6K Puller (M6K-M)

PANACEA P100 LOW PRESSURE USER MANUAL

SDX Submersible Depth Transmitter User Manual

Unblocking the MicroSprayer Aerosolizer Model IA-1C With the High Pressure Reverse Cleaning Adapter. Instructions for Use

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

OPERATING INSTRUCTIONS

G7S Hand Pump Owner s Manual

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

1.0 - OPENING AND CLOSING THE DOOR

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Dissolved Oxygen/Temp Waterproof Tester

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Nanorespiration system user manual

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions

Disassembling and assembling APP and APP 16-22

8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

UsER manual for Watersens ph -REDOX

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

User s Guide. Pressure Controller for liquid delivery systems

SS32L Dissolved O 2 Probe

Quick Start Guide LIQ-QSG-499ACL-03, Rev I July Rosemount 499ACL-03. Monochloramine Sensor

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

! WARNING! IMPORTANT HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES ! WARNING! IMPORTANT SAFETY INSTRUCTION AND GUIDELINES

User s Guide. Vacuum Controller for liquid delivery systems

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

Underwater Housing for Canon EOS M

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

Underwater Housing for Panasonic Lumix DMC-ZS60, DMC-TZ80

602 STRINGING MACHINE OWNER'S MANUAL

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

RST INSTRUMENTS LTD.

Poollift Delphin. Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS

AP100 series ph/redox (ORP) cartridge sensors with water-wash option

PRODUCT SHEET. Order probe only as RXPROBE02

Transcription:

Unisense In Situ UniAmp Connector System

Overview The Unisense In Situ UniAmp Connector system is designed for easy replacement of sensors. Unisense In Situ UniAmp Connector system is a dedicated system for mounting microsensors: Simple and safe mounting Prevent seawater from entering the sensor and connections Enables pressure compensation for deep-sea use Shielding the sensor signal from electrical noise making the sensor signal very stable also in a laboratory setting The connector system is used on Unisense in situ instruments with the in situ amplifiers. Support, ordering, and contact information To order products or if you encounter any problems and need scientific/technical assistance, please do not hesitate to contact our sales and support team. We will respond to your inquiry within one working day. E-mail: sales@unisense.com Unisense A/S Tueager 1 DK-8200 Aarhus N, Denmark Tel: +45 8944 9500 Fax: +45 8944 9549 Further documentation and support is available at www.unisense.com Notice to purchaser: The In Situ UniAmp Connector System is for research-use only! Manual version: 3.0 2

Contents 1. General description of the In Situ UniAmp connector system... 4 2. Pressure compensation... 5 3. Filling connector and sleeve with oil... 6 3.1. Filling the connector body with oil... 6 3.2. Filling the sleeve with oil... 7 4. Mounting the UniAmp connector on the bulkhead... 10 5. Transport and storage of sensor-connector assembly... 11 5.1. Sensors for < 50 m water depth... 11 5.2. Sensors for > 50 m water depth... 11 6. Electrolyte for in situ Sensors... 12 6.1. Electrolyte for in situ sensors:... 12 7. Procedure for refilling electrolyte on in situ sensors... 13 8. Testing the in situ amplifier... 15 9. Testing the microsensor-connector assembly... 15 10. Warranty and liability... 16 10.1. In Situ Amplifier... 16 10.2 Microsensors... 16 3

1. General description of the In Situ UniAmp connector system Microsensor with protection tube In Situ UniAmp connector body Silicone rubber sleeve In situ amplifier Bulkhead connector Figure 1: In situ amplifier and In Situ UniAmp connector with microsensor and protection tube. Microsensors for in situ use are delivered with the In Situ UniAmp connectors mounted. Make sure to test the sensor no later than two weeks after receipt (see the sensor manual). The microsensor-uniamp connector assembly comes in three versions with different depth ratings. Preparations before submersion are different for the three versions: A. Depth rating 0-50 m: The in situ UniAmp connector body is filled with silicone rubber and only the silicone rubber sleeve must be filled with oil before submersion (paragraph 3.2.). B. Depth rating 0-300 m: The in situ UniAmp connector is empty when delivered and the sensor has a pressure compensation wire (Fig. 2). This wire must be removed and both the UniAmp connector body and the silicone rubber sleeve must be filled with oil before submersion (paragraphs 3.1. and 3.2.). C. Depth rating 0-6000 m: Identical to version B except that the space between the assembled bulkhead and UniAmp connector, where the golden pins make connection (see Fig. 9), is oil-filled for pressure compensation. This occurs automatically when surrounding pressure increases, because oil is forced into this space through an opening between the pins connecting this space to the oil filled interior of the UniAmp connector body. 4

2. Pressure compensation 0-50 m sensor 0-300 m or 0-6000 m sensor Interior will be filled with silicone rubber Hole for oil filling Pressure compensation wire Figure 2: In situ UniAmp connectors with (left) and without (right) pressure compensation. Pressure compensation is needed for sensors deployed to more than 50 m water depth. The purpose of the pressure compensation is to maintain equal pressure inside and outside the microsensor. By removing the pressure compensation wire, a channel is created that connects the interior of the sensor with the oil in the UniAmp connector body. The ambient pressure is transmitted from the outside through the silicone rubber sleeve forcing paraffin oil into the sensor as pressure increases during a deployment. For water depths deeper than 300 m also the space, where the golden pins make the connections (see Fig. 9), is pressure compensated. This is obtained automatically through an opening between the golden pins that connects this space to the oil filled interior of the UniAmp connector body. When external pressure increases during a deployment oil is forced from the UniAmp connector body into this space through the opening. NOTE: When this type of sensor is dismounted from the bulkhead oil may spill out. Make sure to refill the oil in the UniAmp connector body and silicone rubber sleeve as needed. With the pressure compensation wire in place, electrolyte will not leak out or evaporate from the sensor. Therefore, removal of the wire and oil filling should first be done close to deployment. After removing the wire and filling the connector with oil the sensor-connector assembly should 5

be placed upright to avoid mixing of oil and electrolyte. The sensor can be tested before removing pressure compensation wire in place and filling the connector with oil. NOTE: The connector body must be filled with oil when the pressure compensation wire is removed. Otherwise the electrolyte will leak out of the sensor. 3. Filling connector and sleeve with oil The required oil filling depends on the depth rating of the sensor-uniamp connector assembly: Depth rating < 50 m: The connector body is filled with silicone rubber when you receive it and only the sleeve must be filled with oil Depth rating > 50 m: Both the connector body and the sleeve must be filled with oil. For filling with oil, you will need: paraffin oil, a syringe with cut off needle, gloves and paper towel Figure 3: Ready for filling with oil. 3.1. Filling the connector body with oil 1. Remove the pressure compensation wire (Fig. 2) by pulling gently using pliers or tweezers. This will leave a channel between the connector and sensor interior. 2. Make sure the sleeve is pushed to one side and inject oil through the hole in the side of the connector body (Fig. 4). Tilt the connector and sensor back and forth to allow the interior of the body to become completely filled with oil and let all the air escape. 3. Slide the sleeve into the closed position between the two protruding rings on the connector body (Fig. 5) completely covering the hole in the connector body. 6

Figure 4: Injecting oil into the UniAmp connector body. Figure 5: UniAmp connector body with the sleeve in the closed position. 3.2. Filling the sleeve with oil Before filling the sleeve with paraffin oil make sure that the connector body is filled with oil (sensors for water depths > 50 m) or with silicone rubber (sensors for water depths < 50 m) and that the sleeve is positioned between the two ridges on the connector body, covering the hole in the UniAmp connector body as shown in Fig. 5. Filling the sleeve with oil: 1. Place the connector and sensor flat on the table with the oil filling hole facing upwards. 2. Insert the cut off needle under the sleeve as shown in Fig. 6. 3. Inject oil slowly, letting it fill the space under the sleeve from below and letting the air out along the needle. 4. Once only a small air bubble is left orient the connector and sensor upright (Fig. 7). Inject oil slowly, letting the last air escape along the needle. Pull out the needle when only a small air bubble is left. The sleeve is now filled with oil and only a small air bubble is left as shown in Fig. 8. 7

Figure 6: Filling the cavity under the sleeve with oil Figure 7: Filling the sleeve with oil and letting the last air escape 8

Figure 8: Sleeve appropriately filled with oil with a couple of small air bubbles left 9

4. Mounting the UniAmp connector on the bulkhead The UniAmp connector body is mounted on a bulkhead connector on an in situ amplifier (as shown in Fig. 9). Mounting the connector on the bulkhead: 1. Make sure that the bulkhead connector and the UniAmp in situ connector are clean. 2. Check that the O-ring is present, lubricated, and intact. Regarding lubrication of the O-ring: after cleaning (if necessary) apply O-ring grease such that the O-ring and groove is covered. Remove excess grease with a dry clean cloth until the O-ring only has a thin shiny layer of grease. 3. Insert the UniAmp connector into the bulkhead, oriented so that the two half-moon shaped parts can pass by each other. 4. Make the hexagonal nut engage with the thread on the bulkhead and hand-tighten this. Do not use tools for this. Bulkhead connector on in situ amplifier Connector with sensor O-ring Figure 9: Bulkhead connector on an in situ amplifier (left) and UniAmp connector with sensor (right) 10

5. Transport and storage of sensor-connector assembly 5.1. Sensors for < 50 m water depth For transport the sensors should be packed in the membrane box in which they are delivered. For correct packing place the sensor in between the two membranes (Fig. 10). For storage see the relevant sensor manual which can be found here: http://www.unisense.com/manuals/ 5.2. Sensors for > 50 m water depth Sensors that have the pressure compensation wire in place (see Fig. 2) should be shipped and stored in the membrane box in which they were delivered. When the pressure compensation wire has been removed, the sensor-connector assembly should be shipped and stored upright with the tip pointing down. This is to prevent electrolyte from entering the connector body. Inside the connector body there are un-insulated cables connecting the sensor to the connector and electrolyte around these may short the sensor. The best way to ship oil filled sensors is to place them upright in boxes with other equipment, e.g. a heavy aluminium box. Such boxes are generally not turned upside down during transport. Figure 10: Membrane box with sensors placed between membranes. 11

6. Electrolyte for in situ sensors Important for deep sea in situ sensors: To enable pressure compensation in the electrolyte reservoir, the in situ sensors for depths > 50 m are equipped with a channel through the glue that binds the inner and outer glass tubes together at the top of the sensor (closed with a silver wire when shipped). Furthermore, part of the space between inner and outer glass tubes is sealed with silicone. Over time electrolyte in the sensor can evaporate or leak through the channel and the silicone. Sufficient levels of electrolyte in the sensor are required for connection between the anodes and the cathodes of Unisense amperometric gas sensors, and for connection between the internal reference of redox and ph electrodes. Furthermore, sufficient electrolyte volume shields against electrical noise. Therefore, it is critical to maintain appropriate electrolyte volume in the sensor. The sensor has appropriate electrolyte volume when only a small air bubble (>0.1mL) is present in the electrolyte reservoir. A minor leak of electrolyte (<10%) can be restored by injecting distilled water into the sensor. In case of an over 10 % leak, the electrolyte should be refilled with the specific electrolyte described in the recipes below. Electrolyte for in situ sensors: ph/redox electrodes: 1 M KCl Oxygen sensors: Add to 1 L of distilled water: 1.25 g KHCO3 25.90 g K2CO3 39.00 g KCl H2S-type sulfide sensors: 50 ml 0.5 M KHCO3 + 50 ml 0.5 M K2CO3 giving solution A Add and dissolve 1.64 g K3Fe(CN)6 in solution A. Chemical grade: Pro analysis, use double distilled water. The solution must be absolutely clean and kept absolutely dark. 12

7. Procedure for refilling electrolyte on in situ sensors CAUTION: The cavity in the centre glass tube of the sensor/electrode with the blank wire is also pressure compensated with a channel, therefore be careful not accidentally to fill electrolyte into this cavity, as this may destroy the sensor. At receipt of the microsensor you will find a pressure compensation wire extending through the oil filling hole of the connector body (see Fig. 2). Leave this wire in place and fill the connector body with oil until the sensor will be used (see 2 above). If the sensor needs to be refilled with electrolyte (see 6 above) the sensor first needs to be removed from the connector. If the connector is oil filled, slide the silicone rubber sleeve to one side to open the hole for oil filling (see Fig. 2) and pour out as much oil as possible. Then loosen the locking nut on the connector (Fig. 11) and pull out the sensor gently out of the connector. Pull the sensor away from the connector taking care not to pull the connecting wires (Fig. 12). The top of the sensor is now exposed, and refilling is now possible. Locking nut Figure 11: Sensor mounted in the in situ connector Refilling of electrolyte or water (see 6. above) is done by injecting it with syringe and needle through the silicone part of the seal between the inner and outer glass tubes at the top of the sensor (see picture above). The largest part of this seal consists of glue and a small part consists of silicone rubber. The silicone rubber part is slightly more opaque than the glue and is soft and can be penetrated with a hypodermic needle. The glue is hard and cannot be penetrated by the needle. Use a clean syringe with a needle of 0.4 mm and fill electrolyte or water (see 6. above) into the syringe. Remove any air bubbles from the syringe. Locate the silicone part of the seal and insert the needle through this, while keeping the sensor vertical (tip down). Insert a second open needle through the silicone (Fig. 12). The tip of the open needle must be just below the silicone seal and will act as a vent to let out air. The tip of the needle, that is mounted on the syringe, must be just at the surface of the electrolyte inside the sensor. 13

Figure 12: Injection of electrolyte into in situ sensor With the needles in place, inject slowly. The electrolyte levels should now increase, with the air escaping through the open needle in the top seal of the microsensor. If electrolyte escapes instead of air try tilt the sensor so the air is on the side of the sensor where the open needle is, reposition needles, inject faster/slower etc. Keep a piece of paper tissue around the top of the sensor to catch spills. When the sensor has been refilled with electrolyte, gently push the connecting wires back into the connector. Then push the sensor in place in the connector and tighten the locking nut by hand. After filling the connector and sleeve with oil (see 3 above) the sensor-connector assembly is ready for use. 14

8. Testing the in situ amplifier The in situ amplifier can be tested by mounting the Test Sensor on the amplifier and recording the signal from the amplifier. The expected signal is indicated on the Test Sensor. The test sensor is an in situ connector without a microsensor. For amperometric amplifiers the Test Sensor is a connector with an electrical resistor mounted inside. This will simulate a microsensor and give a constant signal. For a Test Sensor with a 1 GΩ resistor the signal will be 1 pa for 1 mv polarization. E.g. for an oxygen amplifier the polarization is 800 mv which will generate a signal of 800 pa. In the in situ instrument (e.g. Field Datalogger, Field Datalogger Mini, Underwater Meter) this will give a signal of 800 mv. The oxygen amplifier for Eddy Covariation system is different from the standard oxygen amplifier. The signal is amplified by a factor of 10 and the zero reading is -2500 mv. Therefore, to keep the signal within the working range of the amplifier, a different resistor is used. For example: A test sensor with a 2 GΩ resistor will generate a signal of 400 pa. The amplifier will multiply this by 10 giving a signal of 4000 pa, but because the baseline of the amplifier is 2500 pa the reading will be 4000 pa - 2500 pa = 1500 pa. In the Field Datalogger, 1 pa is converted to 1 mv and the signal will thus be 1500 mv. The Test Sensor for ph and mv channels is an in situ connector with a battery box attached. This will generate a signal in mv as indicated on the side of the Test Sensor. 9. Testing the microsensor-connector assembly The sensor-connector assembly must be tested within 2 weeks of receipt (see 10. Warranty and Liability). The sensor-connector assembly may be connected directly to the in situ amplifier without removing the pressure compensation wire and without filling connector and sleeve with oil. The test is best performed by doing a simple calibration as described in the manual for each sensor type. These manuals can be downloaded here: http://www.unisense.com/manuals/. 15

10. Warranty and liability 10.1. In Situ Amplifier The in situ amplifier is covered by a one year warranty. The warranty does not include repair or replacement necessitated by accident, neglect, misuse, unauthorized repair, or modification of the product. In no event will Unisense be liable for any direct, indirect, consequential or incidental damages, including lost profits, or for any claim by any third party, arising out of the use, the results of use, or the inability to use this product. Equipment that is not covered by the warranty will, if possible, be repaired by Unisense with appropriate charges paid by the customer. In case of return of equipment please contact us for return authorization. For further information please see the documents Conditions for Sale and Delivery for Unisense and Warranty and Shipping Information as well as the manuals for the respective products. 10.2 Microsensors The microsensors are covered by a limited warranty as indicating in the manual for each type of sensor. This warranty requires that sensors are tested within 2 weeks of receipt. Unisense should be notified of any malfunction shortly hereafter. 16