ANNOUNCEMENT. Panther/Cougar Series SCBA Technician Training is a two day class

Similar documents
#121 April 29, 2002 UPDATE OF TECHNICAL BULLETINS

Product Information News

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

Air Mask Low/High Pressure

M7XT Parts List PARTS LIST. TAL 1504 (L) Rev. 2 MSA 2015 Prnt. Spec (I) Mat Doc

12S 1st Stage. -Maintenance Procedure-

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

SERVICE INSTRUCTIONS

AVIATION MAINTENANCE TECHNOLOGY REQUIRED TOOL LIST

Contents. SuperFlow Regulator. 1.1 SuperFlow Demand Regulator. SuperFlow Regulator SuperFlow Demand. Regulator

RG1200 Service and Repair Manual

TECHNICAL TRAINING SS1

K Page 1 of 48 Air Intake - Pg. 17

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Dive Rescue International Terms & Conditions

Hydraulic Punch Drivers

INSTALLATION GUIDE. Doc ID: Doc Rev:

SERVICE MANUAL LEGEND FIRST STAGE

Product Information News September 26, 2003

COUGAR. Self-Contained Breathing Apparatus (SCBA) Product Specification Sheet

MMR Air Mask With. with Quick-Connect Hose

Product Numbers & Ordering Information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

MAINTENANCE PROCEDURE FOR X 650

Helium-Oxygen Blender

CONSHELF XIV TECHNICAL MANUAL

Contents Post Dive Reassembly. SuperFlow 350 Regulator. Adjustment System 1.3 Regulator & Exhaust System Overhaul

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

Regulators repair and maintenance. XS Compact 2nd stage. January 2014 Rev XSC /3 Ed. C /14 1

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

GORSKI G2000SS DIVING HELMET

Contents. General Preventative Maintenance. 1.1 Introduction. 1.2 Required Tools, Sealing, Cleaning, Lubrication Agents

Strong Protection Firefighters Can Count On.

3/8" Dr. Air Butterfly Impact Wrench

SAR/SCBA SS600-AN-MMA-010 Chapter 4

SB 202. Spare parts list Hydraulic breakers. SB 202 s/n BES Construction Tools PC AB No

LOW PRESSURE INFLATION SYSTEM (LPIS) DRY SUIT INFLATION SYSTEM (DSIS) TECHNICAL MANUAL

REGULATORS (SRB3600) Assembly & Maintenance Guide

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Service and Repair Manual

Tidland G690 Leaf Shaft

Training. tm PA90 Series - Lung Demand Valve

RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE

Whisper Pump Service and Repair Guide

GT20 String Trimmer UT Page 1 of 16 Accessories

PARTS, SERVICE & REPAIR BULLETIN

DBML-60/80 Squeeze Tool

REVISED ATTACHMENT 2 BID PRICING FORM

Shocker Sport TM Manual. Includes: Shocker Sport 4X4 TM and Shocker Sport Turbo TM

SASS M110 Repair Parts

CB 350. Spare parts list. Hydraulic concrete buster. CB 350 s/n DEQ Construction Tools GmbH No

( SC) NOTE: KMDSI strongly recommends that all repairs be performed by trained Personnel.

The McHenry Township Fire Protection District (MTFPD) invites interested and qualified parties to submit a request for proposal for SCBA.

SB 452. Spare parts list. Hydraulic breakers. SB 452 s/n BES Construction Tools PC AB No h

500SE SECOND STAGE SERVICE PROCEDURE

PANTHER. Self-Contained Breathing Apparatus (SCBA) Product Specification Sheet

1/4 Air Ratchet Wrench

BMR Low/High Pressure USERS MAINTENANCE INSTRUCTIONS

SERVICE & REPAIR MANUAL H.A.B.D.

H4802, H4802-1, H , and Pole Tampers

PARTS, SERVICE & REPAIR BULLETIN

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

SECTION 2 RING MOUNT

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8

TECHNICAL DATA CAUTION

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

Hatchery Tips from Jamesway s Technical Team. Essential Hatchery Tools by Phillip Perry

REGULATORS OMEGA II SECOND STAGE TROUBLE SHOOTING SYMPTOM POSSIBLE CAUSE TREATMENT

Copyright MAY, 2008 By Grizzly Industrial, Inc. Warning: No portion of this manual may be reproduced in any shape or form without the written

1700ESL Kamvalok Coupler

DP Spare parts list. Demolition pulverizer. DP 2800 s/n DEQ Construction Tools GmbH No

TECHNICAL INFORMATION

KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

Grayslake Fire Protection District Request for Self-Contained Breathing Apparatus (SCBA) Bid

FLOOR STAPLER. WITH HAMMER Model ASSEMBLY and OPERATING INSTRUCTIONS

SINORIX Valve Reconditioning

IMPORTANT SAFETY NOTICE

KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS HELMET AND EMERGENCY GAS SYSTEM DAILY SET-UP AND FUNCTIONAL CHECKLIST APPENDIX A2.

Sperian Warrior SCBA

LRS(H)4 Pressure-Reducing Regulator User Manual

GORSKI G2000SS DIVING HELMET TECHNICAL MANUAL

Service and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

AIR DRIVE ROLL FEED CARTON STAPLER MODEL: H-1031 MANUAL


Build Your Own Flamethrower Step-by-step Manual

Having the right scuba tools for the job saves time and allows the professional technician to concentrate on doing the job right.

VOLUMATIC WATER REGULATOR

U.S. Patent No. 7,922,246. Patents Pending

DS06D,G Dial Set Pressure Regulating Valve

Replacing the Reverse Osmosis ( RO ) Membranes

SCBA Bid Specifications

FACILITY ACCREDITATION CHECKLIST Dec / 1 / 03 APPRENTICESHIP. Rating Code: Y = Yes * N = No * R = Required * AUDIT AREA: DATE: / /

1/2 in. AIR IMPACT WRENCH (TWIN HAMMER)

EKASAND 93 x 178 mm (3 2 /3 x 7 in.) Orbital Sander

G7S Hand Pump Owner s Manual

Transcription:

ANNOUNCEMENT Sperian Respiratory Protection USA, LLC, a Company is pleased to announce our next SCBA regulator repair/maintenance training class to be held in Pembroke Pines, Florida on February 7 th, 8 th and 9 th 2012. We will conduct two sessions, as follows: SCBA Technician Recertification class is a one day class Tuesday, February 7 th Recertification Class (Open ONLY to Current Certified SCBA Technicians, recertifying on MARK 2, SIGMA, or Panther/Cougar Series SCBA) Panther/Cougar Series SCBA Technician Training is a two day class Wednesday, February 8 th Thursday, February 9 th Panther/Cougar Series Initial Training Panther/Cougar Series Rebuild, Troubleshooting and Testing Attendees MUST be Survivair / Sperian users or authorized Honeywell / Sperian service providers with a PosiChek 3. Students will be required to score 80% or better on a written examination and successfully demonstrate skills require to maintain their specific Survivair / Sperian SCBA to be certified. STUDENTS WILL BE REQUIRED TO PROVIDE THE FOLLOWING. Their own tools (maximum 2 students per tool box) All lubricants and sealants (consumables) to support their SCBA 1 SCBA per 2 Students 1 Overhaul Kit for your version of Survivair SCBA A repair class tool list is attached to this form A non-refundable registration fee of $75.00 (per person) for the Recertification class and $150.00 (per person) for the Panther/Cougar SCBA class is required 14 days prior to the class. CLASS SIZE (for each session) IS LIMITED TO 10 PEOPLE Class Site: Pembroke Pines Fire Training Facility 1101 SW 208 th Avenue Pembroke Pines, FL 33029 Local Contact: Chief Scott Withworth 954-557-5606 Walt Bingham 401-225-9251 Local Hotels: Hampton Inn 1900 NW 150 th Avenue Pembroke Pines, FL 33028 954-441-4242 Class hours: 0800 to 1700

CLASS REGISTRATION APPLICATION (Use separate form for each attendee) **Registrations must be received no later than 14 days prior to class** Panther/Cougar Series SCBA technician training is a two day class you must attend both days DATE (S): Tuesday, February 7th ( ) Recertification Wednesday, February 8th ( ) Panther/Cougar Series Initial Thursday, February 9 th ( ) Panther/Cougar Series Troubleshooting SITE: Pembroke Pines Fire Training Facility 1101 SW 208 th Avenue Pembroke Pines, FL 33029 ATTENDEE: COMPANY NAME: Address City, State Telephone Fax Email Address (REQUIRED) Fax registration form to: 800-201-4407 by 23 January 2012 THIS FORM MUST BE FULLY COMPLETED AND RETURNED TO HONEYWELL SAFETY PRODUCTS TO ASSURE PLACE IN THE CLASS Payment Options, One MUST be selected: Check (Mailed) Credit Card (Phone Payment) Direct Bill / Purchase Order reserves the right to accept / reject any application

HONEYWELL REGULATOR REPAIR CLASS REQUIRED TOOL and CONSUMABLES LIST Important Note: Technicians attending Honeywell SCBA Regulator Repair Classes must have the following tools. They MUST bring to class all of the standard tools and the specific tools listed for the regulators that they will be certified on. Technicians must ALSO bring to class the appropriate Overhaul kits and ALL Consumables required to complete the overhaul training. ***A MAIMUM OF TWO TECHNICIANS MAY SHARE THE TOOL KIT*** STANDARD TOOLS FOR ALL REGULATORS (REQUIRED) 1 Screwdriver, Phillips, # 1 tip & Small, Pocket Size 2 Screwdriver, Flat Blade, Medium & Small 3 Retaining Ring Pliers: (Internal & External) 4 T Handle ¼ Driver OR ¼ Drive Ratchet 5 6 or 8 Adjustable Wrench 6 Assorted Picks, Dentist 7 Needle Nose Pliers 8 6 Quick Grip (bar style clamp) or 6 C Clamp 9 ¼ Drive Deep Socket Set: (Must include at minimum: 1 / 4, 5 / 16, 11 / 32, 7 / 16, & 1 / 2 ) 10 Open End Wrenches: (Thin headed Tappet wrenches recommended) (Must include at minimum: 5 / 16, 3 / 8, 7 / 16, 1 / 2, 9 / 16, 5 / 8, 11 / 16, & 3 / 4 ) 11 Allen Wrench Set: (Must include at minimum:.050, 1 / 16, 5 / 64, 3 / 32, 7 / 64, 1 / 8, 9 / 64, 5 / 32, & 3 / 16 ) 12 Tool Box 13 Punch 5 / 64 (Mark 2 & Sigma Machined Body Regulators Only) 14 Torque Wrench (0 100 in.lbs. OR 0 150 in.lbs.) 15 1¼ Crows Foot Wrench For Cylinder Valve * 16 Torque Wrench 0 100 ft.lbs for Cylinder Valve * 17 Small Ball Peen Hammer * *

PANTHER HUD, PANTHER, COUGAR & SIGMA, OMEGA SCBA & SAR SPECIFIC TOOLS 18 Jewelers Flat Blade Screwdriver (Narrow Blade) 19 11/16 Deep Socket, for HUD Hose Swivel 20 7/8 Open End Wrench, for HUD Hose Swivel 22 ¾ and 1 Deep Socket 6 Point, for UAC/RIC Fitting 22 997017 Panther First Stage Whistle Alarm Db Test * @ Fixture 23 997012, Panther Alarm Db Test Fixture for *@ Gauge/Whistle Alarm 24 997009, Panther/Sigma O-ring Tool for Bypass * @ 997010, Panther/Sigma O-ring Tool for Alarm Piston * @ 25 (Needed to install O-ring on discontinued Gauge/Alarm Assy., 961040 & 961060) 26 997011, Panther/Sigma Second Stage Leak Test Tool * @ 27 962246, Speaking Diaphragm and 20/20 Facepiece AIR KLIC Removal Tool * @ MARK 2 SCBA & SAR SPECIFIC TOOLS 28 980027, 1 st Stage Tool, Mark 2 @ 29 980090, 2 nd Stage Tool, Mark 2 @ 30 962246, Speaking Diaphragm and 20/20 Facepiece * @ AIR KLIC Removal Tool 31 # 54 Drill Bit * (Needed to remove alarm seat, 910049, from discontinued piston alarms) 32 Pin Vice for Drill Bit (Needed to remove alarm seat, 910049, from discontinued piston alarms) * HIP PAC, 975200, PRESSURE REDUCER SPECIFIC TOOLS 33 1 Open End Wrench or Adjustable Wrench Capable of 1 (2 Required) 34 Number 61 Drill Bit (Used to remove the piston seat)

POSICHEK 3 SCBA/SAR SPECIFIC ADAPTERS 35 752534, PosiChek 3 Adapter, Panther HUD, OTS (Over- * @ The-Shoulder) Y Buddy Breather 36 752528, PosiChek 3 Adapter, Panther/SIGMA Style * @ w/qd 37 752530, PosiChek 3 Adaptar, Mark 2 /Cougar /OMEGA * @ w/o Q.D. 38 752533, PosiChek 3 Adapter, Hip Pac Regulator * @ 39 752532, PosiChek 3 Adapter, Hip Pac Regulator (Sigma or w/o QD) CONSUMABLES 40 050116 Silicone Lubricant, Dow 111 @ 41 820464 Blue Thread Sealant 242 @ 42 820471 Loctite Inlet, 425 Assure @ 43 820476 Loctite Pipe Sealant 567 @ 44 910699 Christolube MCG 111 @ 45 988198 Blue Sentry Seal @ 46 820490 Molycote 33 @ 47 820489 RTV 108 @ 48 820496 Loctite Primer T747 @ 49 820430 Adhesive Systems 71TL @

OVERHAUL KITS FOR FIRST AND SECOND STAGE REGULATORS (REQUIRED) 50 961571 Panther/Sigma First Stage Regulator Overhaul @ Kit, Machined Body 51 961647 Panther/Sigma First Stage Regulator Overhaul @ Kit, Forged Body 52 961573 Panther/Sigma Gauge and Alarm Overhaul Kit @ (Over the Shoulder Gauge/Alarm Whistle) 53 962073 Panther/Cougar First Stage Overhaul Kit, @ Plain Whistle (Includes parts for complete 1 st stage overhaul w/ Plain Whistle) 54 962074 Panther/Cougar First Stage Overhaul Kit, Bell @ (Includes parts for complete 1 st stage overhaul w/ Bell) 55 962072 Panther/Cougar First Stage Overhaul Kit, @ Warbling Whistle (Includes parts for complete 1 st stage overhaul w/ Warbling Whistle) 56 961572 Panther/Cougar/Sigma Second Stage @ Overhaul Kit 57 961565 MARK 2 First Stage Regulator Overhaul Kit @ 58 980065 MARK 2 Second Stage Regulator Overhaul Kit @ 59 980016 MARK 2 Complete Regulator Overhaul Kit @ : * Indicates optional item for class, but required for every shop. @ Available from your local Sperian / Honeywell Distributor. IMPORTANT: Although Technicians need not bring one to class, they must have access to a calibrated Honeywell Analytics PosiChek 3 with the most current version of Sperian / Honeywell software. The repair facility should have a SOFT JAW BENCH VICE to hold regulators during repair. If there are any questions please call Honeywell Technical Services (800) 394-0410 or the course instructor.