Setting a New Standard in Flash Chromatography Performance

Similar documents
Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

AKTA pure 25 New Owner s Intro

FAST EVAPORATION AT NORMAL PRESSURE

CombiFlash Rf + User Manual

The instrument should have a mass range from 2 to 2000 m/z or better Interface

SOP: Buck Scientific BLC-20P HPLC Operation

AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

CombiFlash NextGen Installation and Operation Guide

Prep LC Training Manual S.V.

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

Recovery collection complete sample recovery in preparative HPLC

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

Prep LC Training Manual

The instrument will process the samples one by one till all the samples have been cleaned up.

AKTA 3D SOP. Click on the System Control tab. This screen has 4 windows.

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

no peaks missing peaks too small peaks increasing retention decreasing retention

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

INSTRUMENT INSTRUMENT YL INSTRUMENT

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

HPLC. Solvent Delivery Module Systems

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

HiQ laboratory gas generators.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Drilling Efficiency Utilizing Coriolis Flow Technology

AKTA MC SOP Page 1 9/27/04 AKTA METAL CHELATING SOP

Peak Biotech - Company & Product Presentation

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

Degassing ERC KK Saitama, Japan

A high flying simplicity DUAL SOFT BAG INJECTION SYSTEM

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Pneumatic high-pressure controller Model CPC7000

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Using the Akta Prime plus October 22, 2012

Agilent 1260 Infinity Purification Solution

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

Tensiometer For the measurement of surface and interfacial tension

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Pneumatic high-pressure controller Model CPC7000

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Your local gas generation partner. Precision series Modular gas generation solution for GC.


PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

Tensiometer For the measurement of surface and interfacial tension

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

Agilent 1100 Series Analytical and Preparative Scale Fraction Collectors. User s Guide

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Agilent 7697A Headspace Sampler

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

GCMSD-Headspace Analysis SOP

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

The Tekran Series 2600-IVS Difference!

High speed UHPLC-MS/MS determination of multiple steroids in human serum using the Nexera MX system for multiplex analysis

Imagine... full flexibility linked to high capacity

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Agilent Dimension Software for ELSD User Manual

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

Automated Liquid Handling Station

Improve Process Reliability

Increasing the productivity of ICP-OES with the Thermo Scientific Qtegra ISDS Software

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Quantitative Analysis of Hydrocarbons by Gas Chromatography

FLUORESCENCE DETERMINATION OF OXYGEN

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

Intermolecular Forces

DOS in Food Science & Nutrition, Manasagangotri, Mysore

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

LUMAZOTE T ECHNICAL BRO CHU RE

Imagine... full flexibility linked to high capacity. Tissue-Tek Prisma & Film. Automated Slide Stainer & Coverslipper

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

Video Notes. LC Troubleshooting Series Retention Time Shifts

Integration of amino acid, acylcarnitine and steroids analysis in single FIA/LC-MS/MS platform

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

Standard Operational Procedure for Capillary Electrophoresis

UltiMate 3000 Viper Capillary Kits for Intelligent LC (LCi) System Solutions

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Gradients in ion chromatography. Optimal separation with shorter analysis time

Recirculating Coolers

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

WHEATON. Peristaltic Pumps. Advancing the Science of Liquid Handling

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller

Thermo Scientific Chromatography Well Plates

Thermo Scientific Chromatography Well Plates

DEBUBBLERS & DEGASSERS ACTIVE DEBUBBLERS APPLICATION NOTE WHY DEGAS YOUR MOBILE PHASE? PAGE 177 STAND ALONE DEGASSERS PAGE 175 PAGE 178

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Low gas volume & flow measurements made easier Gas Endeavour

Additel 761 Automated Pressure Calibrators Selection Guide

UWPR. LC-MS setup. Before you connect your trap and column. Connecting your trap and column

Additel 761 Automated Pressure Calibrators

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

Automated Determination of Dissolved Gases in Water Anne Jurek

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Transcription:

Setting a New Standard in Flash Chromatography Performance What s New Faster Flow rates, up to 300 ml/min Higher pressures, up to 300 psi (20 bar) Bigger touchscreen, 12 or 15 inches Wider Dynamic Range UV Detector Improved baseline correction supports use of absorbing solvents Faster processing with streamlined user interface Space saving top tray holds four 4 L bottles Improved gradient profiles use up to 50% less solvent The CombiFlash NextGen line of systems takes the guesswork out of your purifications and increases productivity whether you are purifying synthetic compounds, natural products, peptides, or polymers. The intuitive PeakTrak software starts a separation in seconds. Select a normal phase or reversed phase column based on the type and amount of sample to purify, allow the RFID tag to load the run parameters, confirm your detector settings (UV, Vis, ELS and MS), press play, load your sample, and walk away. Need to change the parameters? Modify any of the set points including solvent percentages, wavelengths, flow rates, and run time while the separation is taking place. No need to repeat a separation. The CombiFlash you trust, now even better The CombiFlash NextGen still has all the features you count on from CombiFlash systems including RFID identified columns and racks, active solvent and waste level sensing, optimized separations conditions, and an automated injection valve for walk away solid loading. What makes the NextGen even better is its larger touchscreen, higher maximum flow rate and pressure, UV detection with increased dynamic range to accommodate higher sample loading, and updated PeakTrak control with new methods to speed up the purification process without sacrificing purity. This system is also available with an even larger 15 inch touchscreen, a variety of detection capabilities such as visible wave-lengths, Evaporative Light Scattering Detectors (ELSD) and mass spectrometry, an internal vapor sensor to alert you of spills or leaks, and a vapor enclosure for the collection racks for bench top operation. 2

Three Systems to Fit Your Needs Space Saving Design Place all four 4L solvent bottles on top of the units, saving hood space for chemistry Uses minimal hood space, only 14.1inches wide and 17 inches deep including the columns Optional vapor enclosure allows for bench top operation Fully featured and ready to go The CombiFlash NextGen 300+ features all available performance and safety options. Flow rate range is from 1 to 300 ml/min at operating pressures up to 300 psi (20 bar). The system is fitted with a solid load injection valve that can be bypassed if you decide to perform a liquid injection. RFID technology comes standard and automatically reads the size and type of RediSep or RediSep Gold column being used for the purification. Based on this information, the proper method parameters are automatically programmed into the system. Simply insert the column, press Play and the separation starts. This same RFID technology automatically reads the rack types being used ensuring there is never a missed or overfilled tube. Active solvent and waste level monitoring is standard on the NextGen 300+ ensuring that the column never dries out and eliminates messy waste overflows. Flow rates from 1 to 300 ml/min Operating pressure up to 300 psi (20 bar) Powerful Easy-to-Use PeakTrak Control Our intuitive PeakTrak software minimizes the learning curve, enabling the user to efficiently complete their purification, saving time and solvent consumption. Log in through a network connection and control the separation from your desktop. One Screen Operation Active Solvent Level Sensing Start a separation in seconds. Select a column based on the amount of sample to purify, allow the RFID tag to load the run parameters, press play, load your sample, and walk away. On-the-fly chromatographic changes are easy to make on the touchscreen, even during the run. Never run a column dry or overfill a waste container Customizable for your application The CombiFlash NextGen 300 is configurable to your needs. Like the 300+, active solvent and waste level sensing is standard. The system is designed for liquid injections, operating at up to 150 psi (10 bar). If needed, add the solid load injection valve (increases the operating pressure limit to 300 psi (20 bar)) and increase the system s versatility. Similarly, RFID rack and column read can be added if desired. You determine what your needs are; don t invest in unused or unwanted features. Flow rates from 1 to 300 ml/min Operating pressure up to 150 psi (10 bar) Can be upgraded to 300 psi (20 bar) Budget friendly gets the job done The CombiFlash NextGen 100 offers flow rates up to 100 ml/min at operating pressures up to 150 psi (10 bar). This economical system is designed to perform both normal and reverse phase purifications. Flow rates from 1 to 100 ml/min Operating pressure up to 150 psi (10 bar) Mass Directed Purification Collect only those peaks matching the mass of your compound Eliminate the need for further analysis, save time in post-purification processing Rack Sensing Purify more! Up to 75 g with Higher Flow Rates and Pressure Run 750 g columns at flow rates of 300 ml/min (with optional column stand) Purify lower solubility samples with higher, 300 psi (20 bar) pressure limit Extended dynamic range UV detection and dual sensitivity ELSD detects high sample loads while maintaining sensitivity for smaller samples System senses what size tubes are being used eliminating potential missed tubes or overfills Supports a variety of collection rack sizes so that purified compounds can be collected in volumes appropriate for the column size being used Integrated ELSD to Collect Non-Chromophoric Non-Volatile Compounds Integrated into the CombiFlash: No additional system footprint All parameters programmed based on the solvent used or optimize operating conditions for your separation Offers scalability and sensitivity for a wide sample load range Photo Diode Array Detection UV and UV-Vis detectors use PDA technology Display spectra in real time or post run 4

Consumables Model Specifications Accessories NEXTGEN 100 NEXTGEN 300 NEXTGEN 300+ NEXTGEN 100 NEXTGEN 300 NEXTGEN 300+ Not available on all models, see chart. RediSep Rf Columns Economic alternative for your normal-phase separations 40 60µm Irregular Market Leader Industry Standard Reliable/Reproducible RediSep Rf Gold Columns Precision-packed spherical media for high resolution and reproducibility 20 40µm Spherical Load More High Purity Greener/Faster Separations RediSep Rf Gold Reverse Columns Go green with environmentally friendly solvents and these reusable columns. PART NUMBER 12 Inch UV 685250010 685250005 685250001 12 Inch UV-Vis 685250011 685250006 685250002 15 Inch UV NA 685250007 685250003 15 Inch UV-Vis NA 685250008 685250004 Column Size 4 330 gram 4 750 gram 4 750 gram Compatible Large Column NA 605394551 605394551 Adapter Sample Size 10 mg 66 gram 10 mg 150 gram 10 mg 150 gram Recommendation PUMP Heads Single HPLC Dual Syringe Dual Syringe Flow Rate 1 100 ml/min 1 300 ml/min 1 300 ml/min Gradient Formation Binary Binary w/3rd Modifier Binary w/3rd Modifier Low Pressure Low Pressure Low Pressure Solvents 2 Solvents 4 Solvents 4 Solvents Pressure Limit 150 psi (10 bar) 300 psi (20 bar) 300 psi (20 bar) w/injection valve; 150 psi without Gradient Accuracy 2% typical 1% 1% Air Purge NA Standard Standard Level Sensing NA (option) 605257004 Standard /RFID Support DETECTORS Integrated ELSD 605257002 605257001 605257001 (Factory Installed) 1200 Dalton 685237083 685237083 685237083 Mass Spec 2000 Dalton 685237084 685237084 685237084 Mass Spec ESI Probe 250000129 250000129 250000129 APCI Probe 250000128 250000128 250000128 USER INTERFACE INJECTION OPTIONS Injection Valve NA (option) 605257003 Standard Electric 5 gram SLCC 605237047 605237047 605237047 25 gram SLCC 605237048 605237048 605237048 65 gram SLCC 605237044 605237044 605237044 FRACTION COLLECTOR Maximum Racks 2 2 2 Max Number of 150 150 150 16 mm Test Tubes 13x100 mm 605237013 605237013 605237013 16x100 mm 605237061 605237061 605237061 16x125 mm 605237031 605237031 605237031 16x150 mm 605237032 605237032 605237032 18x150 mm 605237033 605237033 605237033 18x180 mm 605237034 605237034 605237034 25x150 mm 605237035 605237035 605237035 480 ml French 605237040 605237040 605237040 Square Bottles SAFETY Vapor Hood 605257008 605257008 605257008 Enclosure Vapor Sensor Option NA 605257005 605257005 Solvent Level NA (option) 605257004 Standard Sensing and RFID Fraction Area NA Lighting Audible Error Alarms Large Column Adapter Supports 750 g, 1500 g, and 3000 g columns (sizes based on silica capacity) 12 or 15 inch Touch Screen Choose the size that fits best in your lab Vapor Enclosure For bench use outside of a fume hood 20 40µm Spherical C18 or C18Aq Medium to High-Polarity Compound Separations High Polar Compound Aqueous/Greener Solvents PeakTrak software Lynx OS Change On The Fly Software Upgrades Free Dimensions 14.1 x 17 x 26 in 14.1 x 17 x 26 in 14.1 x 17 x 26 in (W x D x H) 36 x 43 x 66 cm 36 x 43 x 66 cm 36 x 43 x 66 cm Mass Spectrometer PurIon takes the guesswork out of your purification routine with mass directed purification Certifications CE, RoHS CE, RoHS CE, RoHS 6

Going Green and Saving Time in the Laboratory The CombiFlash NextGen line of systems has been designed to be greener. The NextGen has improved gradient profiles which use less solvent. These solvent savings (up to 50% depending on column size) are seen using the NextGen s optimized default or RediSep Rf Gold Resolution methods compared to previous CombiFlash systems. Switching to reusable reverse phase media packed columns for purifications provides another step forward in reducing your lab s carbon footprint. This line of systems has been designed to be faster. By increasing flow rates while shortening gradient times and eliminating unnecessary re-equilibration steps, the NextGen offers faster methods which increase lab efficiency and throughput. Depending on column size, the time savings can be anywhere from 20-50% using newly optimized default or RediSep Rf Gold Resolution methods. Reducing waste in our Chromatography line is just another way we are using our innovative products to increase productivity while improving the quality of life on our planet....another step forward in reducing your lab s carbon footprint. Teledyne ISCO P.O. Box 82531, Lincoln, Nebraska, 68501 USA Toll-free: (800) 228-4373 Phone: (402) 464-0231 Fax: (402) 465-3091 Teledyne ISCO is continually improving its products and reserves the right to change product specifications, replacement parts, schematics, and instructions without notice. L-5226 Rev 1.0 12/18