INTERNATIONAL EXPLANATION OF CONTACT FUNCTIONS. English. Deutsch. Français. Italiano. Español

Similar documents
ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Bourdon tube pressure gauge for diaphragm seals

Features. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts

SITRANS P measuring instruments for pressure

[Instruments for vacuum measurement, checking and adjustment] 3

RCD - Ultra-Rugged Differential Pressure Flowmeter

Pressure Switches Application Guideline

SPD310/SPD360 Air Differential

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Installation, operating and maintenance Instructions for Seemag bypass level indicator

ATM/Ex - Analog Pressure Transmitter

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Gas density monitor With integrated transmitter Model GDM-100-TI

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

ATM.ECO/IS - Analog Transmitter with Temperature compensation

ATM.1ST/Ex - High Precision Transmitter

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

ATM.ECO - Analog Pressure Transmitter

Pressure Transmitters 36 F-27839

INDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

Electronic relative and differential pressure switch type 616

ATM - Analog Pressure Transmitter

Pressure switch with bourdon tube

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Digital electro-pneumatic regulators Series ER100

Pneumatic pressure switch 20DD

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids

Level transmitter LT 100

Expert Hydrostatic Level Transmitters

HYDRA-line. HYDRA-Gauges Ultra High Purity Pressure Gauge Model HG. Pressure Systems. Applications. Special features. Description

Programmable pressure and temperature transmitters PTM/RS485

Explosion proof pressure switch Model: P953 series

780S Ultra High Purity Series

Programmable pressure and temperature transmitters PTM/RS485

Parametrable / Programmable Pressure Transmitter

Torque Tube TB300 Digital Transmitters

2/ Port G1/4

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Features. Description

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

Product Catalogue. P-SERIES Pressure Gauges

Model 106 DPI "Micro-switch" Installation and Operating Instructions

Pressure Switch for gas and air GGAO-A4

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Monitoring device NTS 30

JUMO dtrans p30 Pressure Transmitter

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Relative and differential pressure transmitter type 692

Mechanical pressure switches

TH-1800-T TRX-700-CNG Converter

Measurement of Low GAS & Liquid Flows

Technical Data. Dimensions

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

ED 701 Hygenic Pressure Transmitter

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Pressure Switch for gas and air

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating Instructions

Technical Data. General specifications. Rated operating distance s n 5 mm

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

How to specify a product. Process Sensors and Mechanical Instruments

C-Flow Coriolis Mass Flow Meters

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

OPTIBAR P 1010 C Technical Datasheet

Technical Data. Dimensions

Relative pressure transmitter type 520

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

Technical Data. Dimensions

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Variable Area Flow Meters. VS Series

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

9700 Transmitter Submersible hydrostatic level transmitter

Technical Data. Dimensions

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

Pressure Switch for gas and air

Smart performance with innovative and ever-strong coil drive even under harsh working environments

Expansion Thermometers Stainless Steel Series, Model 70

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Tapped exhaust port. Sturdy, simple, reliable design. Easy to add on Feedback. High gain pilot valve. Simple calibration, external zero adjustment

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SENSORS Pressure CALDARO

Pressure & Temperature Switches

Pressure Measurement Single-range transmitters for general applications

Technical Data. Dimensions

Programmable Submersible Level Transmitters

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. Dimensions

Bourdon tube pressure gauges for chemical applications EN 837-1

Transcription:

INTERNATIONAL EXPLANATION OF CONTACT FUNCTIONS CONTACT FUNCTIONS EXPLAINED WITH CLOCKWISE POINTER ROTATION STIKO contact Magnetic Inductive Electrical English Translation: NO HIGH Normally open; makes on rise NC LOW Normally closed, breaks on rise STIKO contact Magnetspring Induktiv Elektronik Deutsch Übersetzung: NO Schließer NC Öffner STIKO contact Magnétique Inductive Électronique Français Traduction: FM MAXI Fermeture a maxima OM MINI Ouverture a maxima STIKO contact Magnetico Induttivo Elettrico Italiano Traduzione NA Normalemente aperto NC Normalemente chiuso STIKO contact Magnético Inductivo Eléctrico Español Traducción NA Normalemente abierto NC Normalemente cerrado PAGE 59 DOC 08

MINIMUM PRESSURE RANGE FOR PRESSURE GAUGES WITH ELECTRICAL DEVICE TYPE TYPE OF CONTACT M-x M-xx M-3 M-xxx M-33 I-x E-x I-xx E-xx I-xxx E-xxx Q-3 Q-33 PT5 Add on unit MECHANICAL TRANSMITTERS PT-x (max. 600 bar) case dimensions MINIMUM RANGE (in bar) PBX PBX-SF PBQ PBS PFQ PFS PBB* PBD PMD 00,6 4,6,6,5,5 0,6,6 60,6,5,6,6,5,5 x,6 00,6 4,6,6,5,5 0,6,6 60,6,5,6,6,5,5 x,6 00,6,6 4,6,6,6,5,5,6,6,5 60,6,6,5,6,6,5,5,5 x,6,5 00,6,6 4,6,6,6,5,5,6,6,5 60,6,6,5,6,6,5,5,5 x,6,5 00,6,6 4,6,6,6,5,5,6,6,5 60,6,6,5,6,6,5,5,5 x,6,5 00,6,6 4,6,6,6,5,5,6,6,5 60,6,6,5,6,6,5,5,5 x,6,5 00,6 4,6,6 x x x,6 60,6,5,6,6 x x x,6 00,6,6 4,6,6,6 O.D. O.D.,6,6 x 60,6,6,5,6,6,5 O.D. O.D. x,6 x 00,6,6 4,6,6,6,6,6 x 60,6,6,5,6,6,5 x,6 x POD** 00,6,6** x,6,6** x x x 0,6 O.D. x Excluding -HS 60,6,6** x,6,6** x x x x O.D. x PMX 00,6 4,6,6 O.D. O.D.,6 x 60,6,5,6,6 O.D. O.D.,6 x PMX-E/G*** 60 x x x x,6 x x x x x x PBR PBT 00 5 5 5 5 5 5 5 5 5 5 5 60 5 5 5 5 5 5 5 5 5 5 5 00 6 6 6 6 6 6 6 6 6 6 6 60 6 6 6 6 6 6 6 6 x 6 6 96x96,6 4,6,6,5,5 x,6 PPB**** 44x44,6 4,6,6,5,5 x,6 7x44,6,5,6 x,5,5 x x,6 TYPE PCX*** PMX case dimensions MINIMUM RANGE (in mbar) 00 x x x x x x x x 5 x x 60 x x x x 0 x x x 4 x x 00 40(0) 00 50 40 00 00 O.D. O.D. 5 x x 60 40(0) 00 50 40 00 50 O.D. O.D. 5 x x PMX-E/G*** 60 x x x x 40 x x x 5 x x PMD - low 60 40 00 50 40 00 00 O.D. O.D. 5 x x PPC*** 44x44 x x x x 0 x O.D. O.D. x x x * Only possible with one pointer ** M- and M- / I- and I- not possible in POD models *** PPC, PCX and PMX-E/G only possible with inductive "INTERVALL" Contact type : I-intervall **** Only possible with stainless steel bourdon tube (0) If liquid filled minimum range 400 mbar NOT POSSIBLE PAGE 59a DOC 08

TYPE M Hz BUILT-IN LOW-ACTION CONTACT TYPE M INSTRUMENT : class MINIMAL RANGE : As per page 59 CONNECTOR : cable junction box, SEE BELOW example: HYSTERESIS : max. % up and down SETPOINT(S) : from outside with key PBX00XA WINDOW : PMMA - plexiglass + M- Hz POINTER : black CONTACT POINTER(S) : red ELECTRICAL SWITCH CAPACITY AC : 50 VA (max. 50V) DC : 30 W (max. 50V) CONTACT TYPE SWITCH FUNCTION CABLE JUNCTION BOX CASE DIMENSIONS 00 60 96x96 44x44 7x44 M- Hz* M- Hz* M-3 Hz* M- Hz M- Hz Hirschmann M- Hz M- Hz M-xx Hz +GS* example: M- Hz GS N.A. M-33 Hz N.A. M-33 Hz+GS* N.A. M-xxx Hz functions to be specified at order Wiebrock N.A. M-xxxx Hz functions to be specified at order O.D. O.D. O.D. O.D. N.A. Lx LIQUID FILLED CASE (ONDINA) N.A. N.A. N.A. PAGE 60 DOC 08

TYPE I Hz BUILT-IN INDUCTIVE CONTACT TYPE I INSTRUMENT : class MINIMAL RANGE : As per page 59 CONNECTOR : cable junction box, SEE BELOW example: HYSTERESIS : max. % up and down SETPOINT(S) : from outside with key PBX60XA WINDOW : PMMA - plexiglass + I-xxx Hz POINTER : black CONTACT POINTER(S) : red Also available with: ELECTRICAL SWITCH CAPACITY Nominal voltage : 8VDC (Ri= Kohm) Explosion proof : EEx ia II C T6 Regulations : EN 60947-5- SWITCH FUNCTION CASE DIMENSIONS CONTACT TYPE CABLE JUNCTION BOX OPERATING CURRENT 00 60 96x96 44x44 7x44 I- Hz I- Hz I-x Hz+SN SJ SN (Pepperl+Fuchs) or N.A. N.A. I-x Hz+3.5SN SJ 3.5 SN (Pepperl+Fuchs) or Hirschmann N.A. N.A. N.A. I- Hz I- Hz SJ3.5N SJ3.5N I- Hz SJ3.5N SJ3.5N I- Hz I-xx Hz+SN SJ SN (Pepperl+Fuchs) I-xx Hz+3.5SN SJ 3.5 SN (Pepperl+Fuchs) I-xxx Hz I-xxxx Hz function to be specified at order N.A. N.A. function to be specified at order N.A. N.A. N.A. function to be specified at order O.D. O.D. O.D. O.D. N.A. function to be specified at order O.D. O.D. O.D. O.D. N.A. Wiebrock Lx LIQUID FILLED CASE (ONDINA) N.A. N.A. N.A. PAGE 6 DOC 08

TYPE E Hz BUILT-IN ELECTRONIC CONTACT TYPE E INSTRUMENT : class MINIMAL RANGE : As per page 59 CONNECTOR : cable junction box, SEE BELOW example: HYSTERESIS : max. % up and down SETPOINT(S) : from outside with key PBX00XA WINDOW : PMMA - plexiglass + E- Hz POINTER : black CONTACT POINTER(S) : red ELECTRICAL SWITCH CAPACITY Nominal voltage : 0...30 V dc Proximity sensor : Si-K08-AP6 (Turck) Output : 3-wire, PNP Regulations : EN 60947-5- CONTACT TYPE SWITCH FUNCTION CABLE JUNCTION BOX CASE DIMENSIONS 00 60 96x96 44x44 7x44 E- Hz E- Hz Hirschmann E- Hz E- Hz E- Hz E- Hz Wiebrock E-xxx Hz function to be specified with order O.D. O.D. O.D. O.D. N.A. E-xxxx Hz function to be specified with order O.D. O.D. O.D. O.D. N.A. Lx LIQUID FILLED CASE (ONDINA) N.A. N.A. N.A. PAGE 6 DOC 08

PRESSURE GAUGE WITH LOW HYSTERESIS BUILT-IN MICROSWITCH TYPE Q TYPE Q-3 Hz and Q-33 Hz STANDARD MODEL INSTRUMENT : class MINIMAL RANGE : see page 59 ELECTRICAL CONNECTION : cable junction box HYSTERESIS : max. % up and down SETPOINT(S) : from outside WINDOW : PMMA - plexiglass POINTER : micro adjustable CONTACT POINTER(S) : first red, (second yellow) ELECTRICAL SWITCH CAPACITY 5 Vac : 5A (ind. load 3A) 50 Vac : 3A (ind. load A) DC 30 V : 5A (ind. load 3A) DC 5 V DC 50 V : 0.4A (ind. load 0,4A) : 0.A (ind. load 0,A) CASE DIAMETER ( Ø in mm) CONTACT TYPE TYPE SWITCH FUNCTION 00 60 Q - 3 Hz* SINGLE Class and 5 Amp!! SPDT Q - 33 Hz* DOUBLE 3 DPDT 3 5 4 6 SETPOINT FIXED SETPOINT WITHOUT SETPOINT(S) ADJUSTMENT 0 0 LIQUID FILLING NOT POSSIBLE WITH MICROSWITCH PAGE 63 DOC 08

ADD-ON UNITS WITH ELECTRICAL CONTACTS FOR PRESSURE GAUGES ADD-ON UNIT (contact device on top of dial) with PG cable conduit and 500 mm cable DIN6085/696 Switch function in clockwise direction TYPE CASE DIMENSIONS (in mm) MAGNETIC ADD-ON CONTACT (=30W/~50VA), TYPE: M Ø 00 Ø 60 M - contact closes M - contact opens M -3 single change-over contact (SPDT) M - st contact closes, nd contact closes M - st contact closes, nd contact opens M - st contact opens, nd contact closes M - st contact opens, nd contact opens M -xx+gs double acting contact with separate circuits M -xxx triple acting contact, =closes, =opens INDUCTIVE ADD-ON CONTACT (=8V, Ri= kohm, EEx ia IIC T6), TYPE: I Ø 00 Ø 60 I - contact closes (operating current) I - contact opens I -x+sn single contact with safety oscillator (SN) I - st contact closes, nd contact closes I - st contact closes, nd contact opens I - st contact opens, nd contact closes I - st contact opens, nd contact opens I -xx+sn double contact with safety oscillator (SN) S FOR ELECTRICAL CONTACTS S DESCRIPTION Ø 00 Ø 60 96 x 96 44 x 44 7 x 44 OIL FILLING for HZ electrical contacts: only for AISI304/.430 cases N.A. N.A. N.A. CABLE Cable connected to junction box for HZ electrical contacts First 500 mm: per 000 mm extra: MSR-00 Protection relay for single acting contacts (supply 30Vac) MSR-00 Protection relay for double acting contacts (supply 30Vac) WE 77/Ex- Protection relay for single inductive contacts Eex ia ib IIC (30Vac) WE 77/Ex- Protection relay for double inductive contacts Eex ia ib IIC (30Vac) BUILT-IN TRANSMITTER DEVICES FOR PRESSURE GAUGES BUILT-IN EXECUTION (HZ) C.W. CABLE JUNCTIONBOX TYPE DESCRIPTION CASE DIMENSIONS (in mm) MECHANICAL TRANSMITTER DRIVEN BY POINTER Ø 00 Ø 60 96 x 96 44 x 44 7 x 44 R potentiometer with 0-00 ohm/3-wire output N.A. BUILT-IN TRANSMITTER (SPAN: min..6 bar (max. 400 bar)) Ø 00 Ø 60 96 x 96 44 x 44 7 x 44 PT 4-0 ma, -wire, +3..+35Vdc PT3 0-0 ma, 3-wire, +3..+35Vdc PT5 4-0 ma, 3-wire, +3..+35Vdc N.A. N.A. N.A. PTV 0-0 Vdc, 3-wire, +3..+35Vdc PAGE 64 DOC 08

Transmitter / add on system for low pressure, differential gauges and thermometers APPLICATION MODEL PT5 Suitable for following instruments of ø00 mm and ø60mm: Low pressure capsule gauge: type PCX, PMX Differential pressure gauges: type PBD, PDD, PMD, POD Bourdon pressure gauges: type PBX, PBX-SF, Pressure gauges with chemical seal: type PBQ, PBS, PBR PBT, PFQ, PFS Thermometers: type TXR, TXC and RTX FEATURES Transmitter and contacts have no effect on the pointer. Electronics with RF technology and not mechanically driven for both contacts and transmitter. EMC according to EN636:998 Accuracy equal for the gauge as for the 4 0 ma transmitter EMC according to EN636:998 Power supply 8-8 VDC; max. 50 ma Electrical connections with cable. Protection class IP55. CONTACTS Contacts capable to drive relays, PLC inputs. Operating voltage max. +8 VDC Output current max. 50 ma continuously, with over current - and short protection 4 0 ma transmitter and contacts (sample: capsule gauge PCX00XA 0-5 mbar) 00 CASE DIAMETER 60 TRANSMITTER Output 4 0 ma; 3 -wire Transmitter can be calibrated non lineair, according to the dial. Load impedance RL [kohm] <= (VPSU-8)/0. LIQUID FILLING With type PCX starting from 00 mbar, only ONDINA 00 60 SETPOINTS FIXED SETPOINTS SET BY STIKO PAGE 65 DOC 08