TEST REPORT TS EN : TS EN A1 Windows and doors - Product standard. Testing Reference. : BM 72 Gizli Kanat Pencere (Hidden Vent Window)

Similar documents
ETEM S.A. LIGHT METALS COMPANY 1, IROON POLYTEHNIOU STR. GR MAGOULA ATTIKIS GREECE

ETEM S.A. LIGHT METALS COMPANY 1, IROON POLYTEHNIOU STR. GR MAGOULA ATTIKIS GREECE

Evidence of Performance. Class 4. Class 5A. Class C5 / B5. Test Report No PR01. ift Rosenheim

TEST CERTIFICATE PARTIAL REPRODUCTION OF THE PRESENT CERTIFICATE IS PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION BY EKANAL.

TEST CERTIFICATE THE RESULTS CONCERN ONLY THE SPECIMEN TESTED. THE PRESENT DOCUMENT DOES NOT CONSIST PRODUCT APPROVAL BY E.K.AN.AL.

Test Report. Test Report Smart Systems Limited Incorporating Smart Extrusions. Page 1 of 78

OS2 F R A M E S E R I E S

CONTENTS 1. INTRODUCTION DESCRIPTION OF TEST SAMPLE TEST RIG GENERAL ARRANGEMENT TEST SEQUENCE...7

REPORT ON ENVELOPE AIR TIGHTNESS TESTING SPORTS HALL HMP LITTLEHEY CROW SPINNEY LANE PERRY HUNTINGDON PE28 0SR CLIENT: WATES CONSTRUCTION

Technical Report. Title: Product weathertightness testing of a sample of W.G.Ltd 500 series Curtain Walling for The Window Glass Company Limited

Intertek Testing Services Building Products. Enterdoor AB ubv

PERFORMANCE TEST REPORT FOR AIR LEAKAGE AND DURABILITY OF BARRIER PRODUCTS ASTM E Rendered to: BAUTEX SYSTEMS

Overview ASTATT3. Carry out air tightness testing for single dwellings and other small buildings

01 18/11/2013 correction of the reference of the product 1 4 5

Air Leakage Detailing & Awareness Services

TEST REPORT. Solamatrix Inc. GLASS-GARD GGL1200 Multi-ply Window Film and Wetglaze Anchoring System on Single 6mm (1/4 ) Annealed Glass.

Technical Report. Product testing of 6 mm Graniti Fiandre Maximum panels with support system and fabrication by Telling Architectural

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A STRUCTURAL PERFORMANCE TEST REPORT SUMMARY RENDERED TO:

LATICRETE International Inc. One LATICRETE Park North Bethany, CT USA

CE conform applications according to EN Windows without thermal break Systems Forster presto and Forster norm

SMOKE CONTROL DOORS AND SHUTTERS

Air Pressure Test to EN13829:2000

CYCLIC PERFORMANCE PER ASTM E 330 TEST REPORT. Rendered to: TRUSEAL TECHNOLOGIES, LTD. PRODUCT TYPE: Fixed Window

1688 Jean-Berchmans-Michaud Drummondville, Quebec. J2C 8E9. Mr. Marc-Etienne Mathieu,ing.

Stirley Barn Pressurisation Test Fri 13-Dec-2013

ASTATT10 Carry out air tightness testing on large and complex, high rise and phased hand over zonal buildings

AIRTIGHTNESS OF BUILDING PENETRATIONS: AIR SEALING SOLUTIONS, DURABILITY EFFECTS AND MEASUREMENT UNCERTAINTY

Measuring range Δp (span = 100%) Pa

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Surface Mount NTC Thermistors. Link: RT Tables. NST Series

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

Bold Line Top Stage Incubator

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Series Smoke Seals in Accordance with BS 476: Part 31, Section 31.

RTG 25. Introduction

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Old documentation - Only for your information! Product is not available anymore!

Sartorius CCL kg Prototype Mass Comparator

CR Series. Special doors for clean room application

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Intertek Testing Services Taiwan Ltd.

High-performance submersible pressure transmitter For level measurement Model LH-10

Test report for UN 38.3 Lithium ion cells

Presented to the IAPMO Standards Review Committee on March 7, 2016

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

rpbsafety.com Samoset Rd Royal Oak, MI USA OF THE NOVA 3 ABRASIVE BLASTING SUPPLIED AIR RESPIRATOR

Automatic Isokinetic Sampler. ST5 Evo

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

Bomb Blast Mitigation Test

Definitions 13 FREE SURFACE EFFECT

Note: All batteries are supplied with only a residual charge and should be charged at the continuous charge rate before use.

Ratio Regulator Zero Governor. FRG/6 Series

Evaluation of n-situ easurement ethods for ir ermeability of indows

Disclosure to Promote the Right To Information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

UniSas BA. Physical single-person detection. Models: UniSas BA9, UniSas BA12. Energy savings. Eco-design. Recyclable product. Manual Attack Resistance

CompacSas BA. Comfort and design for high-security access

mass of container full of air = g mass of container with extra air = g volume of air released = cm 3

This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or

The CompacSas BAH airlock is the ideal solution for transforming an existing door into an airlock

TESTING APPLICATION STANDARD (TAS)

VINAYAK PHARMA TECHNOLOGY

Technical Data Sheet MF010-O-LC

VENTILATOR OPTIONS. Please visit our web page to view all the available options and for a specification.

Report on the Acceptance Air Leakage Testing of Rectory Cottage in Langattock, Powys, in compliance with ATTMA TSL1 (2010)

ThermaSkirt A N E C O R E V O L U T I O N I N R O O M H E A T I N G

Building air tightness

Product Test Report F.A. Lennon Drive December 2015 Solon, Ohio U.S.A. Page 1 of 7. Valve Series Description Test Pressure Test Qty.

Performance Standards for Non-Turf Cricket Pitches Intended for Outdoor Use [TS6] ecb.co.uk

Full-Vacuum Chlorinator C 2212 MB / 1

The elegant solution for enhanced security. Manual Attack Resistance. Ballistic Resistance. Recyclable product. Eco-design. exit

CFSW. Hinges with built-in safety multiple switch

CORESTA RECOMMENDED METHOD N 6

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

Report on Air Leakage Testing, in compliance with ATTMA TSL1 (2010) Site address: Cropthorne Autonomous House, WL10 3LZ. Autonomous House, Evesham

CFSW. Hinges with built-in safety multiple switch

High-performance submersible pressure transmitter For level measurement Model LH-10

TR Test Report Complementary Testing RKN e1 Container (+5 C) Protection by Insulation Version: 01 Page: 2 (22)

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Procedure Instruction of program Pressurized Enclosure - Test Round 2017

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

Duration: 4 hours Type: self-learning 2h and class room lectures 2 hours. Dr.sc.ing. Anatolijs Borodiņecs

MSC Guidelines for Review of Cargo and Miscellaneous Vessel Stability (Subchapter I)

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

AES-28/50/75/110/150 RFG Sterilization Autoclaves with counter pressure and fast cooling

National Health Service Model engineering Specification

VALVE MANUFACTURERS ASSOCIATION API 622 API 624

Fixed Displacement Plug-In Motor A2FE

Surface Test Report. IMPORTANT NOTE: This report does not constitute an ITF Court Pace Classification.

DNVGL-CP-0187 Edition March 2016

56 LESLIE HOUGH WAY SALFORD GREATER MANCHESTER M6 6AJ UNITED KINGDOM. Tel: +44 (0) Fax: +44 (0)

Gas Pressure Regulator RMG 201

Notes on equipment protection per EN/IEC and NEMA For Bourdon tube or diaphragm pressure gauges

MSC Guidelines for Review of Passenger Vessel Stability (Subchapters K & H)

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Report on Pre-improvement Air Leakage Testing, in compliance with ATTMA TSL1 (2010)

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

Transcription:

TEST REPORT TS EN 12153 Testing Reference : TS EN 14351-1 +A1 Windows and doors - Product standard Product / Project : BM 72 Gizli Kanat Pencere (Hidden Vent Window) Prepared by : Nilay BULUT Accreditation Nr. AB-0531-T 2/16

1. PREFACE This report comprises of tests and results, which were performed by FTI Facade Testing Institute at the address; Çakıl Mah. Şehit Teğmen Tamer Aydın Sok. No: 76 34540 Çatalca Istanbul / TURKIYE. Test sample is a window system which name is BM 72 Gizli Kanat Pencere (Hidden Vent Window) has been designed and constructed by Burak Alüminyum San. ve Tic. A.Ş.. Tests were carried out on 26.10.2017 for the determination of air infiltration, water penetration (under static pressure), wind resistance, extreme wind load resistance. Test sample has been sent to FTI Façade Testing Institute s testing laboratories on 23.10.2017. 2. CLIENT Burak Alüminyum San. ve Tic. A.Ş. Yeni Mh. Muratlı Asfaltı No:10 Büyükkarıştıran Lülebürgaz / Kırklareli / TURKIYE 3. TEST METHODS The above mentioned test has been carried out in project specifications and classified on the standard indicated below. Document No Date of Press Subject of Document TS EN 14351-1 +A1 01.2012 Windows and doors - Product standard, performance characteristic - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics TS EN 1026 07.2016 Windows and doors - Air permeability - Test method TS EN 12207 03.2017 Windows and doors - Air permeability - Classification TS EN 1027 07.2016 Windows and doors - Watertightness - Test method TS EN 12208 03.2004 Windows and doors - Watertightness - Classification TS EN 12211 07.2016 Windows and doors - Resistance to wind load - Test method TS EN 12210 07.2016 Windows and doors - Resistance to wind load Classification 4. TEST DATE AND PARTICIPANTS Tests were performed on 26 / 10 / 2017 by the followings: Oner ARSLAN FTI Laboratory Manager Berk ÖZTÜRK FTI Testing Engineer And partially, Hüseyin GURSOY Burak Alüminyum San. ve Tic. A.Ş. Accreditation Nr. AB-0531-T 3/16

5. DESCRIPTION OF TEST SAMPLE Type of sample Window System name BM 72 Gizli Kanat Pencere (Hidden Vent Window) Dimensions of sample 1244 mm x 1244 mm Surface area of sample 1,55 m 2 Dimensions of sash 546 mm x 1124 mm Area of sash 0,61 m 2 Sashes Joint Length 3,34 m Glass Type 6 mm transparent float glass + 16 mm air space + 6 mm transparent float glass Figure 1. The view of the sample Accreditation Nr. AB-0531-T 4/16

6. CONDITIONS Date : 26 / 10 / 2017 Local Temperature (ºC) : 20 Atmospheric Pressure (Mbar) : 1025 Ambient Humidity (%) : 65 7. TEST PERFORMANCE 7.1. Pressure Sequence STEPS POSITIVE PRESSURE (Pa) NEGATIVE PRESSURE (Pa) 1 PA 600 600 2 PW 1650-3 PD 2000 2000 5 PE 3000 3000 PA: Pressure for Airtightness ; PW: Pressure for Watertightness ; PD: Design Pressure ; PE: Extreme Pressure 7.2. Air Permeability Before starting the test, 3 pulses at 660 Pa is applied to the sample. During the tests, the pressure at the following values is applied for 10 seconds. The following data includes the values of the system after tare. Air leakage measurements based on overall area for operable parts 70,00 60,00 Air Leakage (m 3 /h/m 2 ) 50,00 40,00 30,00 20,00 10,00 Test Pressure (Pa) 0,00 50 100 150 200 250 300 450 600 Positive Pressure 0,19 0,52 0,69 0,74 0,96 0,97 1,36 1,63 Negative Pressure 0,06 0,45 0,59 0,65 0,82 0,91 1,18 1,56 Classification 65,5 65,5 65,5 56 56 30 30 10 Test No: 2017.897.06-07 / 26.10.2017 Accreditation Nr. AB-0531-T 5/16

20,00 Air leakage measurements based on operable joint length Air Leakage (m 3 /h/m) 15,00 10,00 5,00 Test Pressure (Pa) 0,00 50 100 150 200 250 300 450 600 Positive Pressure 0,00 0,02 0,02 0,05 0,05 0,01 0,04 0,02 Negative Pressure 0,04 0,02 0,02 0,02 0,00 0,02 0,02 0,06 Classification 16,3 16,3 16,3 14 14 14 7,5 2,5 Test No: 2017.897.08-09 / 26.10.2017 7.3. Watertightness Under Static Pressure Before starting the test, 3 pulses at 1815 Pa were applied to the sample. Waiting duration between each impacts were 3 seconds. An adjustable device for spraying water 2,0 l/m 2.min so that a constant and continuous film was applied to the outside surface of the specimen. The amount of water applied to the façade = 2,0 l/min x 1,55 m 2 = 3,1 (l.m 2 /min). Accreditation Nr. AB-0531-T 6/16

Observations Pressure Value (Pa) Time Period (min) Observations 0 15 No water leakage was observed. 50 5 No water leakage was observed. 100 5 No water leakage was observed. 150 5 No water leakage was observed. 200 5 No water leakage was observed. 300 5 No water leakage was observed. 450 5 No water leakage was observed. 600 5 No water leakage was observed. 750 5 No water leakage was observed. 900 5 No water leakage was observed. 1050 5 No water leakage was observed. 1200 5 No water leakage was observed. 1350 5 No water leakage was observed. 1500 5 No water leakage was observed. 1650 5 No water leakage was observed. Test No: 2017.897.10/ 24.07.2017 7.4. Resistance to Wind Load Before starting the test, 3 pulses at 2200 Pa for positive and negative design load test. Waiting duration between each impacts were 3 seconds. During the tests, the test pressure values are applied for 10 seconds. Length of vertical profile L = 1244 mm The measured frontal deflection (d) on the vertical profile should not exceed identified limit which is determined according to the following criteria : if d L/150, Class A if d L/200, Class B if d L/300, Class C L / 300 = 1244 mm / 300 = 4,14 mm for L/300 criteria. Accreditation Nr. AB-0531-T 7/16

Figure 2. A view of the wind load sensor location Accreditation Nr. AB-0531-T 8/16

Deflection (mm) 4 3,5 3 2,5 2 1,5 1 0,5 0 Test Pressure (Pa) Deflection Measurements at Positive Wind Load 0 2000 Sensor 1 0 0,88 Sensor2 0 1,45 Sensor3 0 0,91 Frontal Deflection 0 0,555 Classification 4,14 4,14 Test No: 2017.897.11 / 26.10.2017 0,1 Residual Deformation After Positive Wind Load Test Deflection (mm) 0,05 0 Time (sec.) 0 10 20 30 40 50 60 Sensor 1 0 0 0 0 0 0 0 Sensor 2 0,01 0,01 0,01 0,01 0,01 0,01 0,01 Sensor 3 0,02 0,02 0,02 0,02 0,02 0,02 0,02 Frontal Deflection 0 0 0 0 0 0 0 Test No: 2017.897.11 / 26.10.2017 Accreditation Nr. AB-0531-T 9/16

Deflection (mm) 4 3,5 3 2,5 2 1,5 1 0,5 0 Test Pressure (Pa) Deflection Measurements at Negative Wind Load 0 2000 Sensor 1 0 0,81 Sensor2 0 1,43 Sensor3 0 0,83 Frontal Deflection 0 0,61 Classification 4,14 4,14 Test No: 2017.897.12 / 26.10.2017 0,1 Residual Deformation After Negative Wind Load Test Deflection (mm) 0,05 Time (sec.) 0 0 10 20 30 40 50 60 Sensor 1 0,01 0,01 0,01 0,01 0,01 0,01 0,01 Sensor 2 0,01 0,01 0,01 0,01 0,01 0,01 0,01 Sensor 3 0,01 0,01 0,01 0,01 0,01 0,01 0,01 Frontal Deflection 0 0 0 0 0 0 0 Test No: 2017.897.12 / 26.10.2017 Accreditation Nr. AB-0531-T 10/16

7.5. Cycle The test specimen was subjected to 50 cycles including negative and positive pressures, with the following features: -Test pressure equal 1000 Pa ; - First step was negative, next was positive as was the last sequence of 50 impulses; - Value + 1000 Pa was maintained at for 5 s. After completion of the 50 cycles, there was no damage observed on the sample at the end of the test. ± 1000 Pa were applied for 50 cycle. (Test No : 2017.897.13 / 26.10.2017) 7.6. Air Permeability (Repeat) Before starting the test, 3 pulses at 660 Pa is applied to the sample. During the tests, the pressure at the following values is applied for 10 seconds. The following data includes the values of the system after tare. In this test, overall area air permeability values were similar of first values of the first air permeability test. Thus, sash taped values were not needed to take. So, first sash taped values were used for fixed joint length in this test. Air leakage measurements based on overall area for operable parts Air Leakage (m 3 /h/m 2 ) 70,00 65,00 60,00 55,00 50,00 45,00 40,00 35,00 30,00 25,00 20,00 15,00 10,00 5,00 0,00 Test Pressure (Pa) 50 100 150 200 250 300 450 600 Positive Pressure 0,24 0,59 0,67 0,72 0,86 0,98 1,37 1,48 Negative Pressure 0,19 0,61 0,66 0,81 1,02 1,13 1,27 1,76 Classification 65,5 65,5 65,5 56 56 56 30 10 Test No: 2017.897.14-15 / 26.10.2017 Accreditation Nr. AB-0531-T 11/16

Air leakage measurements based on operable joint length 20,00 Air Leakage (m 3 /h/m) 15,00 10,00 5,00 0,00 Test Pressure (Pa) 50 100 150 200 250 300 450 600 Positive Pressure 0,02 0,05 0,01 0,04 0,00 0,01 0,05 0,05 Negative Pressure 0,02 0,06 0,01 0,06 0,10 0,13 0,02 0,15 Classification 16,3 16,3 16,3 14 14 14 7,5 2,5 Test No: 2017.897.14-15 / 26.10.2017 7.7. Extreme Load In this test, 1,5 times design load was applied to the sample. Test Pressure Positive Applied Negative Observations PE + 1980 Pa - No damage was observed on the sample. - - 1980 Pa No damage was observed on the sample. Test No: 2017.897.16 / 26.10.2017 Accreditation Nr. AB-0531-T 12/16

8. RESULT CONDITIONS RESULT CLASS FINAL AIR PERMEABILITY TS EN 12207 WATER- TIGHTNESS (Static Pressure) TS EN 12208 RESISTANCE TO WIND LOAD (design load) TS EN 12210 at 600 Pa,air leakage<10 m³/(h.m²) overall area at 600 Pa, air leakage<2,5 m³/(h.m) operable joint length at 600 Pa,air leakage<10 m³/(h.m²) overall area at 600 Pa,air leakage<2,5 m³/(h.m) operable joint length There should be no water leakage at 1650 Pa 2000 Pa, L/300 = 4,14 mm frontal deflection < L/300 2000 Pa, C = L/300 = 4,14 mm frontal deflection < L/300 Positive Pressure air leakage Negative Pressure air leakage 1,63 0,02 1,56 0,06 There was no water leakage observed on the sample. Positive Pressure frontal deflection Negative Pressure frontal deflection 0,55 mm 0,61 mm Class 4 Class 4 Class 4 E 1650 C5 CYCLE TEST There should be no damage during the test + 1000 Pa and 1000 Pa for 50 cycle No damage was observed on the sample. OK AIR PERMEABILITY TS EN 12207 (repeat) AIR PERMEABILITY TS EN 12207 (compare) RESISTANCE TO SAFETY LOAD TS EN 12210 at 600 Pa, air leakage < 10 m³/(h.m²) overall area at 600 Pa,air leakage < 2,5 m³/(h.m) operable joint length at 600 Pa, air leakage < 10 m³/(h.m²) overall area at 600 Pa, air leakage < 2,5 m³/(h.m) operable joint length at 600 Pa, air leakage < 1,63 + 2,00 m³/(h.m²) at 600 Pa, air leakage < 0,02+ 0,5 m³/(h.m) at 600 Pa, air leakage< 1,56 + 2,00 m³/(h.m²) at 600 Pa, air leakage< 0,06 + 0,5 m³/(h.m) There should be no damage at +2000 Pa and -2000 Pa. Positive Pressure air leakage Negative Pressure air leakage Positive Pressure air leakage Negative Pressure air leakage 1,48 0,05 1,76 0,15 1,48 0,05 1,76 0,15 There was no damage on the sample. Class 4 Class 4 Class 4 OK Accreditation Nr. AB-0531-T 13/16

9. TEST PHOTOS Accreditation Nr. AB-0531-T Report Nr. 020.977.1/2017 Date 04.12.2017 14/16

2 3 DET5 DET7 1 1 DET4 DET6 2 DET1 DET2 DET3 3 2-2 SECTION 3-3 SECTION 1244 1-1 PLAN GIESSE PENCERE MENTEŞESİ (85 KG) WINDOW HINGE GIESSE ÇİFT MAÇALI KOL TWO-WAY CREMONE 1244 613015 *KAPASİTE: 85KG (3AD) *CAPACITY: 85 KG (3 PCS) 413004 REPORT NO: PAGE NO: 020.977.1/2017 15/16 NOTIFIED BODY NO: ACCREDITATION NO: REPORT NO: PREPARED BY: CONTROL BY: NB 2547 AB 0531 T 020.977.1 /2017 N. BULUT Ö. ARSLAN PROJECT Project Code: Client: Explanation: BM 72 HIDDEN VENT WINDOW 2017.897 BURAK ALUMINYUM SAN. VE TIC. A.S. DATE: REV.NO: AIR PERMEABILITY, WATERTIGHTNESS AND RESISTANCE TO WIND LOAD 04.12.2017 A F.15.21 REV.NO:A OCAK 2012

DET1 DET2 DET3 REPORT NO PAGE NO 020.977.1 / 2017 16/16 DET4 DET5 DET7 DET6 NOTIFIED BODY NO ACCREDITATION NO REPORT NO PREPARED BY CONTROL BY NB 2547 AB 0531 T 020.977.1/2017 N. BULUT Ö. ARSLAN DETAIL: SAMPLE NO CLIENT EXPLANATION BM 72 HIDDEN VENT WINDOW PLAN & SECTION DETAILS 2017.897 BURAK ALUMINYUM SAN. VE TIC. A.S. DATE REV.NO AIR PERMEABILITY, WATERTIGHTNESS AND RESISTANCE TO WIND LOAD 04.12.2017 A F.15.21 REV.NO:A OCAK 2012