Osmosis - dependence of the osmotic pressure on the concentration (Item No.: P )

Similar documents
Second Edition Chemistry Experiment Supplies MODULE #1

Basic Flows in a Microfluidic Device

Operating Instructions

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

29 Pressure, Temperature relationship of a gas

5/16 MAXFLOW SPOUTS 17/64 MAXFLOW SPOUTS. 5/16 black spout with barbs $0.25 $ /64 white spout without barbs. 5/16 white spout without barbs

Lab Session #4 AN Physical Properties

Mayfly in the Classroom: Basic apparatus assembly

Lab 4: Transpiration

Patients Guide for Self Administering Intravenous Antibiotics General points

Adaptations of Desert Plants

BOYLE S / CHARLES LAW APPARATUS - 1m long

LABORATORY TECHNIQUES. Pouring Liquids

BASIC LAB SKILLS: EIGHING BALANCE AND BUNSEN

INSTRUCTION MANUAL. January 23, 2003, Revision 0

The Ideal Gas Constant

Using Surveying Equipment

BENEFITS SAMPLERS FOR SUSPENDED SEDIMENT P Watertrap sampler. The winch of the Watertrap is fixed to the railing of a bridge.

Hydrostatics Physics Lab XI

LAB 13: FLUIDS OBJECTIVES

Armatures for analytical probes

Transpiration. DataQuest OBJECTIVES MATERIALS

QUIK-jet Micro-Injection System

Filtration FILTRATION PRODUCT TIPS

TO RECEIVE the most benefit from a

Instruction Manual. Pipe Friction Training Panel

SCF Enviro-Friendly. Back-up Ring. Endcap. #7141 (for both) O-Ring. Back-up ring and O-ring fit onto end cap.

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method

Aerobic Respiration. Evaluation copy

Radnoti Liver Perfusion System

EcoCell Vertical Electrophoresis Unit

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

2. investigate the effect of solute concentration on water potential as it relates to living plant tissues.

DURRIDGE STAINLESS STEEL SOIL GAS PROBE

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

Density and Stress in Plastics Mary V. McCrary

BPS-2, Rev TABLE OF CONTENTS

Pressure Reducing Valve DMV 750 set range: bar

Determine the Velocity of a Softball

A Liter a Lung Measuring Lung Capacity

Pure Water Power Purification System 4-Stage RODI Operations Manual

Single vessel air injection technique for determining xylem resistance to cavitation. Martin Venturas, 2014

Experiment 18 Properties of Gases

E-118 Assembly Guide

COLD WELD COPPER TUBE SAMPLING EQUIPMENT AND PROCEDURES

Poollift Delphin. Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Measuring Carbon Dioxide in Breath

M03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR DETERMINING THE LIQUID LIMIT OF SOIL

The SPI Sputter Coater Handbook

TEXAS A&M UNIVERSITY PHYSICS LECTURE DEMONSTRATIONS

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Bottle Rocket Launcher P4-2000

Instruction Manual Updated 5/26/2009 Ver. 2.0

Belt strength. Available the belt. (kg/m) PP - Polypropylene 2, to [B] PE - Polyethylene 1, to [B]

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

POLYMER TEST KIT (CLAPPER METHOD) OFI PART No

Halsey Taylor Owners Manual

Standard Operating Procedure for Zooplankton Sample Collection and Preservation

Instruction Manual SB02, SB03, SB04 All metal flow limiter

Experiment 1 Introduction to Some Laboratory Measurements

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Determination of the Gas-Law Constant (R) using CO2

Rudder Kit Assembly Instructions for Quest 13

INFLATOR TDUX-IT-16 AND GAS CYLINDER E

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

Halsey Taylor Owners Manual

Read over Techniques #2, 4, 5, 6, and 9 in the Demonstrations of Nine Practical Lab Techniques booklet.

Pipette apparatus. Meet the difference. Manual. T E I

Working correctly with gas

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

FIRST TEAM SPORTS, INC Storm Portable Series Assembly Instructions

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

[285] NOTE ON A SIMPLE GAS-CIRCULATING PUMP

Intro: by firechim on October 3, 2013

SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Build your own weather station

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

OPERATING INSTRUCTIONS

Name:. Correct Questions = Wrong Questions =.. Unattempt Questions = Marks =

OPERATING INSTRUCTIONS

Slide and Turn System SF35

Making a Barometer and Using It

THE OWNER'S MANUAL IS IN TWO VOLUMES: VOLUME 2 TECHNICAL SPECIFICATIONS - ASSEMBLY PROCEDURE ZODIAC

UMBILICAL CORD MODEL FOR UMBILICAL VEIN CATHETERIZATION TRAINING

TEST SPECIFICATION NYT-909-C

Gas Laws. Introduction

Series V47 Temperature Actuated Modulating Valves

Students measure the change in pressure by varying the volume of trapped air in a syringe while:

QE-1, Rev Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

OPERATIONS CHALLENGE 2017

Operating Instructions

CHM 2045L Physical Properties

The second stage cannot begin until the first stage is complete.

SRI Model H2-40 Hydrogen Generator Operation and Maintenance Nov 2006

Transcription:

Osmosis - dependence of the osmotic pressure on the concentration (Item No.: P1135700) Curricular Relevance Area of Expertise: Biology Education Level: University Topic: Plant Physiology / Botany Subtopic: Mineral Balance Experiment: Osmosis - dependence of the osmotic pressure on the concentration Difficulty Preparation Time Execution Time Recommended Group Size Intermediate 10 Minutes 50 Minutes 2 Students Additional Requirements: Experiment Variations: Keywords: Osmose, Osmotic pressure, Concentration Principle and equipment Principle Educational objective Osmosis is an essential process to move solutions of within a biological systems. To simulate osmotic processes, the segment apparatus is useful. You can run quantitative osmosis experiments with which you use different kinds of solutions (e.g. with glucose resp. copper sulphate) with different concentrations to compare their behaviour. The segment apparatus can also be used for experiments in other areas (e.g. electrochemistry).

Note Osmosis instrument with 7 chambers for quantitative experiments As far as osmosis experiments are concerned, the instrument offers the opportunity to double the effective membrane surface and, thereby, to speed up the osmotic process, which is a considerable advantage for demonstration lessons in particular. Safety measures Wear protective glasses and gloves! Waste disposal Collect soultions containing heavy metall ions in the collecting container for heavy metall waste.

Equipment Position No. Material Order No. Quantity 1 Precision Balance, Sartorius ENTRIS623-1S, 620 g / 0,001 g 49294-99 1 2 Osmosis and electrochemistry chamber 35821-00 1 3 Supplement chamber for osmosis / electro chemistry 35821-10 5 4 Filtration stand for 2 funnels 33401-88 1 5 Scale 350 mm 64840-00 7 6 Support rod, stainless steel, 750 mm 02033-00 1 7 D(+)-glucose 1-hydr. 250 g 30237-25 1 8 Support rod, stainless steel, l = 600 mm, d = 10 mm 02037-00 2 9 Cellophane, 300x200 mm, 5 sheets 32987-00 1 10 Copper-II sulphate,cryst. 250 g 30126-25 1 11 Scissors, straight,180 mm 64798-00 1 12 Water, distilled 5 l 31246-81 1 13 Capillary tube,i.d. 1.5mm,l 450mm 05939-00 7 14 Right angle clamp 37697-00 2 15 Glass tube holder with tape measure clamp 05961-00 7 16 Glass beaker DURAN, tall, 250 ml 36004-00 3 17 Spoon, special steel 33398-00 1 18 Funnel, glass, top dia. 55 mm 34457-00 1 19 Wash bottle, plastic, 500 ml 33931-00 1 20 Glass rod,boro 3.3,l=300mm, d=7mm 40485-05 3

Set-up and procedure The osmosis and electrochemistry chamber is perfectly suitable for the observation and demonstration of osmotic processes. In its simplest form, this apparatus consists of the two glass end segments a and b (fig. 1) and two rubber sealing rings c that are connected with the aid of the flange holder. Every segment has a short glass tube connector with a GL25 thread onto which a connecting cap with a sealing ring (25/8 mm) can be screwed. For osmosis experiments, glass capillary tubes are inserted into these connecting caps. If a suitable semipermeable membrane, e.g. made of cellophane, is placed between the two sealing rings (d, fig. 1) and if the two chambers are screwed together, including the sealing rings with the membrane, the result is a double-chamber apparatus as shown in Fig. 2. Multi-chamber apparatus. Additional chambers (fig. 3) as well as additional flange holders, pairs of sealing rings, and membranes can be used to set up a multi-chamber apparatus (Figs. 4, 5, and 6). As to which set-up should be selected depends on the teaching objective. If the objective is to simply observe the fundamental process of osmosis, the set-up that is shown in Fig. 2 is absolutely sufficient (basic apparatus plus capillaries). If, however, the aim is to also demonstrate the dependence of the osmotic pressure on the concentration of the solutions, a multi-chamber set-up as shown in figs. 5 and 6 should be used. The membranes are made of cellophane. Since cellophane is only available in large sheets, a circular model with a diameter of 52 mm must be cut out of flat cardboard. Then, use this model to draw the shape of the membranes on the sheet of cellophane with the aid of a water-soluble marker pen. The membranes thus prepared must then be cut out with a sharp pair of scissors and thereafter be placed in pure water for swelling. In order to fasten the membranes in the apparatus, always place one membrane between two sealing rings without folding it and place these elements on the horizontal flange of a segment. Then, attach the next segment with the corresponding flange and screw both segments together with the aid of the flange holder. When joining the segments, ensure that the glass connectors with the screw caps face the same direction.the apparatus thus produced stands on the flange holders. In order to fix the glass capillaries in place, a support base (taken from the filtration stand) must be divided as shown in fig. 6. Then, a support rod (l = 600 mm) must be fastened into each of the halves before attaching an additional support rod (l = 750 mm) horizontally between the two vertical support rods with the aid of two right-angle clamps. This horizontal support rod is used to hold the glass tube holders, which in turn receive the upper ends of the glass capillaries. Run different experiments with copper sulphate and with glucose. Copper sulphate has the advantage that colour intensity is an indicator for its concentration - the more intense the colour, the higher the concentration. First, fill the segments that are to hold the solutions (segments 2, 3, and 4 in fig. 6). This also provides the membranes with the correct tension. For the multi-chamber set-up that is shown here, a 5%, 10%, and 15% copper sulphate solution or a corresponding series of sugar solutions is used: There are 7 segments. Eventually, the following solutions must be filled into the following segments:

Segment 2: 5% solution Segment 4: 10% solution Segment 6: 15% solution Segment 1, 3, 5, 7: water After the solutions have been filled into the apparatus, check the membranes for leaks. It must be absolutely ensured that none of the solutions can flow into the neighbouring chambers! Then, fill the remaining chambers with pure water (segment 1 in fig. 6). The solutions and the water should reach the upper rim of the glass connectors. Now, the screw caps with the sealing rings are screwed on. Insert the capillary tubes into the sealing ring and push them in so that the liquid rises to approximately 100 mm in all of the capillary tubes. Lastly, the scales are pushed onto the capillary tubes from behind. This initial position can be marked with a suitable glass marker pen. The capillary tubes are held in place at their upper ends. Eventually, the experimental setup for quantitative readings looks as in fig. 6. Fig. 6

Observation and evaluation The solutions rise in the capillary tubes while the pure water descends in the capillary tubes. The higher the concentration of a solution is, the more quickly it rises. To take measurements, use a watch to measure the time it takes for the solutions with their different concentrations to rise. Create a chart and enter the readings as a function of time and analyse the data. Eventually, compare your experimental findings with your assumptions which you made before running the experiment.