TECHNICAL MANUAL. DHR70N Polar. Den Haan Rotterdam

Similar documents
TECHNICAL MANUAL DHR70N. Den Haan Rotterdam

TECHNICAL MANUAL DHR55N. Den Haan Rotterdam MED96/98/EC

TECHNICAL MANUAL DHR40 LED. Den Haan Rotterdam MED96/98/EC

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam MED96/98/EC

TECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam

DHR40 LED TECHNICAL MANUAL

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Rule 21 - Definitions

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

Prewired position switches FA series

Magnetic level switch type MR783 Instruction Manual

INSTRUCTION MANUAL Pressure Relief Device LPT

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions

Position switches FP series

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

Extra wide viewing angle from single indicator lamp. Lenses made from polycarbonate and hardened glass. 10mm Panel Hole.

Mörth Marine Austria / / Tel.: 0043 (0) Mörth Marine Slovenia

Operating Instructions

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Further technical information is available on

a. On the centerline of the T-top b. On the aft starboard corner of the deck c. On the aft deck as close to centerline as possible

Operating Instructions

Airfield Lighting. Product Description. Omnidirectional Elevated Obstruction Light (F2.1, F22)

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

Datasheet liniled Handrail 42.4 V1017 IK10. F RoHS FROST CLEANING AGENTS RESISTANT UV RESISTANT

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

EX-RECESSED CEILING LIGHT FITTINGS

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the COLREG

fischer Epoxy Mortar FIS EB

Datasheet liniled Handrail 48.3 V1017 IK10 IP68. F RoHS IP40/IP65 FROST CLEANING AGENTS RESISTANT UV RESISTANT

Less power great performances

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

User Manual V14.1 IP68 LED FLEX NEON

PRAHER PLC-MP AQUASTAR MANAUL 2009

GEMS SENSORS & CONTROLS

RR 16 Commercial & Industrial Regulator

MODELS (2 foot Version) (4 foot Version)

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

fischer Epoxy Mortar FIS EB The basic epoxy mortar for applications in concrete

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

A-100, AD, CD, CD2M and PD Membrane level indicator for solids. Operating Instructions. Safety instructions Operating instructions

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

datasheet M25S 24VDC motor Features & benefits

Airfield Lighting. Omnidirectional Elevated Light (F2.1) Product Description

Available models Devices Color White sealing bellows Black sealing bellows NDT SW NDT GB NDT RT NDT GN NDT WS NDT BL NDT GR

Pressure switch and Thermostat CAS

T-CITY. Waterproof protection for LED lighting

Airfield Lighting Product Description F2.1

Erection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure Reducing Valve DMV 755

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

IMO CONSIDERATION OF IACS UNIFIED INTERPRETATIONS

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Pressure relief valve DHV 718

CFSW. Hinges with built-in safety multiple switch

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

CFSW. Hinges with built-in safety multiple switch

VALVES ISO 5599/1, SERIES IPV-ISV

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

Rocky Mountain Element Technical Manual. Rev B

GUKO FDA. einfach. gut. beraten.

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

differential pressure regulating valve - threaded

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Plankton pump Model ,2 KWatt. Manual. KC Denmark. Research Equipment Limnology Oceanography Hydrobiology

Infrared Linescanners

AR740 RPS Redundant Power Supply Quick Install Guide

PURGEX X Purge Controller E Version. User s Manual

Materials : Dichromate zinc plated steel flanges or AISI 316

Materials : Electro galvanized steel flanges

Materials : Galvanized steel flanges

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

About. providing superior performance and reliability. Bromic regulators are AGA or UL144 approved.

Pressure switch and Thermostat Type KPS

EPRB-2 Pressure Transducer

Gas density monitor With integrated transmitter Model GDM-100-TI

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Technical Data Sheet. R&M Closures

Automatic Twin Greasing System

Automatic extractor outlet

Operating Instructions

Alhambra Arabic design, British engineering

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

Installation and Operating Instructions Bypass Flow Meter DST

Pressure switch and Thermostat KPS

Instruction manual. HLSD-2 Circular Access Tank Cover IM-TE91K041-EN1 ESE Date of issue: August 29, 2012

Transcription:

TECHNICAL MANUAL DHR70N Polar SINCE 1922 Den Haan Rotterdam

WARNING! - Turn power off before inspection, installation or removal - Keep combustible materials away from lamp - Allow lamp/fixture to cool before handling! Damage due to inappropriate handling is not covered by the warranty. DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manuals is incomplete or incorrect. We do not guarantee that the information in the manual is suitable for the purpose for which the information was consulted. All information is offered in the state in which it actually is and without any (implicit) guarantee or warranty regarding its validity or its suitability for a particular purpose or otherwise. All illustrations are for illustrative purposes only. This manual is not intended to cover every possible detail about the product. We exclude all liability for any damages, direct or indirect, of any nature whatsoever, arising from or in any way connected with the use of this manual. In addition we are not liable for damages, direct or indirect, arising from the use of information obtained from this manual. A user of this manual may not publish copyright protected works or other information from the manual or in any way reproduce the information without our permission. This also includes the reproduction of information or parts thereof by publication in an electronic (computer) network. Copyright, Den Haan Rotterdam B.V. This document contains proprietary information that is protected by copyright. All rights reserved. 2

TABLE OF CONTENTS 1. Technical data 4 2. Product photo 5 3. Dimensions 6 4. Electrical specification 7 5. Exploded view 8 6. Positioning side lights 9 7. Positioning all-round lights 10 8. Mounting 10 3

1. TECHNICAL DATA Application: Sea-going vessels navigating in Arctic regions of more than 20m in length Inland navigation In compliance with: International Regulations for Preventing Collisions at Sea; COLREG 72 and latest amendments The Directives 96/98/EC and 82/714/EC, following the European standard: EN 14744 (2005) AC(2006), Inland navigation vessels and sea-going vessels - navigation light RS Rules, part XVII, item 7.11.2.2 The Technical Regulation on the Safety on Sea Transport Items TR-620 Materials: Housing, matt black high-grade polycarbonate reinforced with fibre glass Fresnel lens, shock resistant polycarbonate Screen, seawater resistant aluminium - hard anodized 70 µm black Mounting materials, stainless steel A4, seawater resistant, non-magnetic Gaskets, silicone rubber Protection class: Min. IP56 complete with membrane vent Operation temperature: Type tested from -52 C up to +55 C Min. visibility: Sector lights All-round Starboard 3 NM 71.11.00.00 White 3 NM 71.16.00.00 Port 3 NM 71.12.00.00 Manoeuvring 5 NM 71.16.10.00 Masthead 6 NM 71.13.00.00 Red 3 NM 71.17.00.00 Stern 3 NM 71.14.00.00 Green 3 NM 71.18.00.00 Stern - Red 3 NM 71.14.17.00 Yellow 3 NM 71.19.00.00 Towing 3 NM 71.15.00.00 Electrical insulation class: Power supply: I, (grounded) 230VAC 50/60Hz Cable: THERMFLEX 180 EWKF-C 5G1-1,5 metre Bulb: Normalized bulb P28s Max. 65W (European standard: EN 14744) Heating element: Transparent heater 70W complete with thermostat Mounting: Base mounting only 4

2. PRODUCT PHOTO 5

3. DIMENSIONS 310 200 155 155 200 4 x Ø11 All dimensions in mm. 6

4. ELECTRICAL SPECIFICATION Bulb P28s 230V 65W Transparent heater 70 Watt Thermostat 5/10 C 1 2 3 4 5 5 x 1 mm² 230VAC 50/60Hz Wire Colour Description 1 Blue Bulb 2 Brown Bulb 3 Gray Heater 4 Black Thermostat/Heater 5 Green/Yellow Earth 7

5. EXPLODED VIEW 1 2 3 4 5 6 7 Item Part Material Quantity Art. code 1 Top part c/w heatsink and Polycarbonate reinforced with 1 71.99.80.00 membrane vent fibre glass - black 2 Gasket large Silicone - white 1 71.99.00.55 3 Bulb P28s 230V Max. 65W 1 70.99.03.10 4 Screen starboard Seawater resistant, 1 71.99.02.10 Screen port Hard anodized 70µm 71.99.02.15 Screen masthead 71.99.02.20 Screen stern 71.99.02.30 Screen 180 71.99.02.80 5 Lens complete with Polycarbonate - red 1 71.99.70.01 transparent 70 Watt heater Polycarbonate - green 71.99.70.02 Polycarbonate - crystal clear 71.99.70.03 Polycarbonate - smoky 71.99.70.04 Polycarbonate - yellow 71.99.70.05 6 Gasket small Silicone - white 1 71.99.00.60 7 Bas part c/w cable, Polycarbonate reinforced with 1 71.99.30.00 lamp holder and thermostat fibre glass - black 8

6. POSITIONING SIDE LIGHTS 70 Paint the inside matt black 60 K 280 Parallel to the keel line 0 2 400+H 8 J2 8 H 148 L L 460 500 600 700 800 910 H 0 6 20 34 48 63 K 122 121 118 113 109 105 J2 260 270 300 330 360 390 [mm] Disclaimer: The minimum luminous intensity requirements in the forward direction are only guaranteed if the sidelights are mounted inside the vessels inboard screens in accordance with this drawing and table. This is an illustration to indicate the dimensions of the inboard screens, relative to the keel line of the vessel. By no means may this image be used to determine the actual position of the sidelights on the vessel itself. For positioning the lights at the vessel always check for compliance with COLREG 72 or local rules. 9

7. POSITIONING ALL-ROUND LIGHTS S[mm] D 200 180 160 140 120 D[mm] 6 100 S 1000 1200 1400 1600 1800 Diagram for choosing the minimum distance between obstacle and mounting plate. Disclaimer: This is an illustration to indicate the position of the all-round light relative to a mast. All round lights shall be so located as not to be obscured by masts, topmasts or superstructures within angular sectors of more than 6. By no means may this image be used to determine the specific position of the all-round lights on the vessel itself. Hence, always check for compliance with COLREG 72 or local rules. 8. MOUNTING M Bolt M10 x (40+M) Washer M10 Lantern base Mounting plate // 00,5 Washer M10 Nut M10 All dimensions in mm Mounting plate The mounting plate for navigation lights should be at least 5 mm thick and should not exceed a parallelism of // 00,5. Fasteners Permissible torque 8 Nm Use only A4-grade stainless steel Important Do not paint or use any other chemical for the lanterns, clean only with fresh water. 10

This page is intentionally left blank 11

ADVANCED MARITIME SIGNALLING SOLUTIONS SIN C E 1922 Den Haan Rotterdam Fascinatio Boulevard 1182 2909 VA Capelle a/d IJssel The Netherlands T +31 (0) 10 413 07 55 E sales@dhr.nl www.dhr.nl