EFFECTS OF BAFFLE SIZE ON PRESSURE DISTRIBUTION IN VACUUM CHAMBER DURING DYNAMIC GAS FLOW

Similar documents
The new PTB standard for dynamic vacuum pressures

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

CHEM 355 EXPERIMENT 7. Viscosity of gases: Estimation of molecular diameter

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal

Introductory Lab: Vacuum Methods

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

Instruction Manual. Pipe Friction Training Panel

Experiment 8: Minor Losses

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

REPRODUCIBILITY IN OPTICAL THIN FILM PROCESSING PART 1, THE VACUUM AND PUMPING

End of Chapter Exercises

Total Pressure Measurement Using Residual Gas Analyzers

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Gas Laws. 1. Gases are said to exert pressure. Provide a molecular-level explanation for this. Copyright Cengage Learning. All rights reserved.

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

The Discussion of this exercise covers the following points:

Gas Pressure. Pressure is the force exerted per unit area by gas molecules as they strike the surfaces around them.

The Experts in Vacuum Solutions

Determination of Air Density with Buoyancy Artefacts

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION

Chapter 10: Gases. Characteristics of Gases

OPTIMIZATION OF INERT GAS FLOW INSIDE LASER POWDER BED FUSION CHAMBER WITH COMPUTATIONAL FLUID DYNAMICS. Abstract. Introduction

Old-Exam.Questions-Ch-14 T072 T071

Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors

End of Chapter Exercises

Pressure Measurement

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Chemistry A Molecular Approach. Fourth Edition. Chapter 5. Gases. Copyright 2017, 2014, 2011 Pearson Education, Inc. All Rights Reserved

DESIGN AND PERFORMANCE OF THE NEW SARTORIUS 1 KG VACUUM MASS COMPARATOR AT PTB

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

GA / 3.02 TL 4 TL 6. Cat. No Calibrated leaks GA / 3.02 TL 4 TL 6. Cat. No

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory

Vacuum Simulations of the KATRIN Experiment

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

Effect of Nozzle Twisted Lance on Jet Behavior and Spitting Rate in Top Blown Process

Two interconnected rubber balloons as a demonstration showing the effect of surface tension

EXERCISE 2: THE VACUUM SYSTEM

Analysis of Pumping Characteristics of a Multistage Roots Pump

The Gas Attenuator of FLASH

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

Unit 2 Kinetic Theory, Heat, and Thermodynamics: 2.A.1 Problems Temperature and Heat Sections of your book.

Assumptions 1 At specified conditions, air behaves as an ideal gas. 2 The volume of the tire remains constant.

SPH 4C Unit 4 Hydraulics and Pneumatic Systems

3. A fluid is forced through a pipe of changing cross section as shown. In which section would the pressure of the fluid be a minimum?

Chapter 5: Gases 5.1 Pressure Why study gases? An understanding of real world phenomena. An understanding of how science works.

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Chapter 5. Nov 6 1:02 PM

Heat Pump Connections and Interior Piping

Instrumentation & Data Acquisition Systems

THE IMPLEMENTATION OF TOROIDAL THROAT VENTURI NOZZLES TO MAXIMIZE PRECISION IN GAS FLOW TRANSFER STANDARD APPLICATIONS

The Helium Leak Detector

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

Memorandum Background: Results and Discussion:

13.1!"#$#%"&'%()$*+%,+-.$+/*$#

Laboratory Experiments No 1: Measuring the Number Distribution

Flow and Mixing in the Liquid between Bubbles

Reflux Condensation with Various Non-Condensable Gases

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

The Study of Bubbly Gas-Water Flow Using

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

Procedure 1: Volume vs. Pressure 1.) Using the lap tops, go to the Physics Education Technology from the University of Colorado at:

EFFECTS OF CHEMICAL ADDITIVES ON THE PRESSURE DROP IN THE PIPES

You should be able to: Describe Equipment Barometer Manometer. 5.1 Pressure Read and outline 5.1 Define Barometer

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

Sartorius CCL kg Prototype Mass Comparator

Resist round robin ELETTRA

Name Chemistry Pre-AP

8. Now plot on the following grid the values of T (K) and V from the table above, and connect the points.

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

FPG8601 Force Balanced Piston Gauge

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

The Discussion of this exercise covers the following points: Range with an elevated or suppressed zero Suppressed-zero range Elevated-zero range

An experimental investigation of the influence of the expansion of the moist air on its relative humidity

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator

Free Surface Flow Simulation with ACUSIM in the Water Industry

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Wind tunnel effects on wingtip vortices

ELEVATION CORRECTION FACTORS FOR RADON MONITORS*

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers

at NIST: ultra-low outgassing rates

KINETIC THEORY OF GASES

Radar, Ultrasonic and RF Level Transmitters

1. All fluids are: A. gases B. liquids C. gases or liquids D. non-metallic E. transparent ans: C

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

REVERSE FLOW PRESSURE LIMITING APERTURE (RF-PLA) ESEM Research Laboratory, 98 Brighton Boulevard, North Bondi, NSW 2026, AUSTRALIA

The University of Hong Kong Department of Physics Experimental Physics Laboratory

Fig. 2. M.I. Yaroslavtsev, 2002

9 Mixing. I Fundamental relations and definitions. Milan Jahoda revision Radim Petříček, Lukáš Valenz

Transcription:

XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal EFFECTS OF BAFFLE SIZE ON PRESSURE DISTRIBUTION IN VACUUM CHAMBER DURING DYNAMIC GAS FLOW Wakil Khan 1, 2, Y.H. Shin 1, S.S. Hong 1* 1 Vacuum Technology Centre, KRISS, Daejeon 305-340, Republic of Korea, *sshong@kriss.re.kr 2 University of Science and Technology (UST), Daejeon 305-333, Republic of Korea Abstract - Vacuum technology is one of the established advanced technologies, of present age, in the field of research and industry. Having numerous applications, in the areas of human activities, one is concerned with a relatively large vacuum chamber where pressure distribution is, usually, not uniform during dynamic gas flow. To minimize the pressure non-uniformities in such chambers, baffles are generally used. In the present work, rectangular-shaped baffles of different sizes are used in a cylindrical-shaped chamber of a flow-control system, developed by Korea Research Institute of Standards and Science (KRISS). The chamber is large enough and has been experimented for pressure distribution at four different points in the pressure range from 0.1 Pa to 133 Pa by using five identical Capacitance Diaphragm Gauges (CDGs). One of these gauges serves as a reference gauge and is fixed at one point while the readings of the other four gauges were recorded by using baffles of various sizes and, at the same time, producing the pressure dynamically in the chamber. It is worth mentioning that before installation, all of these gauges were calibrated on Ultrasonic Interferometer Manometer (UIM). The data, thus obtained, along with relative deviations of the gauges readings are plotted for all the three baffles which represent the behavior of gas pressure in this particular chamber. Keywords: vacuum chamber, baffle plate, flow control system. 1. INTRODUCTION Vacuum chambers have wide applications for a variety of purposes such as vacuum gauge calibration, material processing, electron simulated desorption, etc. In many industrial vacuum processes, pressure is generated dynamically in vacuum chambers. For example, the calibration of vacuum gauges according to secondary standards is usually performed in calibration chambers where the pressure is generated dynamically [1]. The throughput Q of the calibration gas argon or nitrogen is introduced through a fine control variable leak valve and pumped continuously by a pumping system. Under such circumstances, the pressure in the chamber is determined by the equilibrium between the gas flow in and the gas flow out. As regions of the chamber act as sources and sinks for the gas flow, a non-uniform distribution of pressure occurs over the whole chamber [2]. The term non-uniformity of gas distribution refers to the change of the flow, density and pressure values depending on the position in a vacuum system [3]. There are two (main) sources of nonequilibrium and the pressure non-uniformity in a vacuum chamber where pressure is generated dynamically [4]; inlet of the gas and its sink in the pump. Repa [2] has calculated pressure differences of a few percent between various positions for gauges on a vacuum chamber in the range 10-3 Pa 10-1 Pa. Similarly, G. Horikoshi [5] has shown, by obtaining some functional relations, that even in a onedimensional model the pressure is not constant in a vacuum chamber (in the range 10-1 Pa 1 Pa) during dynamic gas flow. In order to suppress the influence of the gas sources and sinks, the chamber has to have a suitable shape, it has to be sufficiently large, the gas after admission should be scattered by impinging on the walls, etc [4]. Chambers of spherical or cylindrical shapes are used for this purpose [2]. The stream of the calibration gas is scattered in order to achieve a uniform pressure distribution [1] within the chamber. The scattering of calibration gas is usually done by using a baffle on the path of the gas molecules. As has been shown by experiments, when a simple baffle is placed on the path of the gas molecules, the beaming effects will be reduced [6]. An appropriate position of the baffle is also essential, since it scatters the molecules by itself, thereby changing the spatial distribution of the gas [6]. One such system having facility of gas flow control & baffle installation is developed at Vacuum Technology Center, Korea Research Institute of Standards & Science (KRISS), for the purpose of vacuum gauge calibration & related experiments. The chamber of the system has been experimented for pressure uniformity by using baffles of three different sizes. From the data obtained, it is concluded that for fixed volume of chamber, proper size of baffle, depending on chamber s geometry, can be used for minimizing the pressure non-uniformities. 2. THEORY Analysis of vacuum system characteristics is based on

the assumption that molecular velocity distribution is Maxwellian and their flux intensities are isotropic. The assumptions have been confirmed in many experiences [7]. The kinetic theory of gases provides a straightforward relationship between the number density of molecules and pressure in such cases [8]. However, the isotropic state is disturbed by the dynamic molecular flow of gas resulting from localized or distributed (usually both) sinks and/or sources. Depending on their contribution to the process, these sources and/or sinks cause non-uniform and nonisothermal gas flow in the pumped vessel. Industrial vacuum equipment subject to dynamic working conditions does not permit isotropic gas conditions at reduced degree of rarefaction [8]. Such systems are termed as nonisotropic systems. The system under consideration is a nonisotropic system working in the medium vacuum range (0.1 Pa 133 Pa). Depending on pressure and the cross dimensions of a tube, three types of flow can be differentiated [9]: continuum or viscous flow, molecular flow, and transitional flow. Knudsen in 1910 found experimentally that the number K n = λ/d (Knudsen number) which is the ratio of mean free path (λ) of the gas particles to the cross dimension (d) of the vacuum component, can supply information concerning the gas flow regime [10]. Similarly, to describe the type of gas flow, it is convenient to use the Knudsen number [11]. The value of λ for gas consisting of molecules of same diameter is given by [10]: 24 3.107 10 T = (m) (1) 2 p m Where T (K), p (Pa), and m (m) are temperature, pressure and diameter of the gas molecules respectively. For nitrogen gas the value of m is 3.78 10-10 m. On the basis of Knudsen number gas flows can be classified as [8]: K n < 0.01 Viscous flow K n > 3.0 Molecular flow 0.01 < K n < 3.0 Transitional flow These defining values are not as sharp as is implied, but their general correctness is founded in experimental results [12]. In the viscous (continuum) flow regime, gas behaves as a (continuous) fluid and molecule-molecule collisions with mean free path much less than the equipment size determines gas behavior. At low pressures, mean free path becomes greater than the container s characteristic dimension. Molecule-surface collisions dominate the gas behavior, molecule-molecule collisions become quite rare, and the gas flow under such conditions is termed as molecular flow. The intermediate flow regime between viscous & molecular, known as transitional regime occurs in the medium vacuum range. In this range, collisions of gas particles with the wall (surface) occur just about as often as mutual collisions amongst gas particles [9]. The gas flow in this regime, also called the Knudsen flow, is composed of viscous (laminar) and molecular flow. On further decreasing the pressure, the flow becomes molecular while increasing the pressure, the flow shifts towards the continuum state. 3. EXPERIMENTAL SETUP AND PROCEDURE The flow control system is shown in Fig. 1. The 36.65 l chamber is pumped by a high vacuum pumping unit consisting of a turbomolecular pump (pumping speed = 560 l/s for N 2 ) and a scroll pump (pumping speed 300 l/m). The chamber is equipped with different types of vacuum gauges, ranging from low to high vacuum range & mass flow controllers. Of these gauges, five capacitance diaphragm gauges (CDGs) are used for recording the experimental data as the capacitance sensing technique results in a high degree of pressure sensitivity. It is one of the most important gauges in low and middle vacuum range [13] and is widely used in industries based on vacuum technology as measuring device because of the easy use, good accuracy and resolution as well as good compatibility with most of gases [14]. It is worth mentioning that before installation, all the CDGs were calibrated on ultrasonic interferometer manometer (UIM). The positions of all five CDGs on the vacuum chamber are shown in Fig.1. Initially the system was evacuated to base pressure < 6 10-6 Pa through gate valve (GV). During experiment, the GV remained closed and the system is pumped through bypass line. The test gas was leaked into the system through mass flow controllers MFC1 & 2 with respective gas flow ranges of 1 slm & 3 sccm (1slm = 1.69 Pa.m 3 s -1 and 1sccm = 1.69 10-3 Pa.m 3 s -1 ). Fig. 1. The dynamic flow control system. It was observed that the gas molecules become in equilibrium within the chamber in about 25-30 minutes after gas injection. The gas flow versus generated pressure (CDG3) without baffle is shown in Fig. 2.

Table 1. The values of mean free path λ and Knudsen number K n for different values of average generated pressure with chamber s dia 0.256 m. Fig. 2. Gas flow versus generated pressure (CDG3) in the chamber without baffle. Ten data points (one set) in the desired range of pressure were recorded. Each set of data points was repeated four times. The system is fully operated through Labview computer software program. The test gas used was nitrogen of 99.99 % purity. Three baffle plates of respective cross sectional areas 132 cm 2, 289 cm 2, and 405 cm 2 at a distance of 30 mm from the top of the chamber were used one by one and the distribution of pressure was checked. For convenience, on the basis of their sizes, these baffles are called small, medium, and large size baffles respectively. Pressure (Pa) Mean Free Path λ (m) Knudsen number K n 0.87 0.00734 0.02867 2.0 0.00316 0.01236 2.5 0.00257 0.01000 9.9 0.00065 0.00253 19.7 0.00033 0.00127 27.4 0.00024 0.00091 45.9 0.00014 0.00054 99.3 0.000064 0.00025 106.7 0.000060 0.00023 113.2 0.000056 0.00022 120.0 0.000053 0.00020 From Table 1, it is clear that, for pressure p < 2.5 Pa, the value of K n remains in the limits 0.0286 0.01 confirming that the gas flow in the chamber in this pressure range is transitional. Above 2.5 Pa pressure, K n < 0.01 showing that as pressure increases above 2.5 Pa, the flow in the chamber is shifting toward viscous state with frequent collisions of gas molecules, reduced mean free paths, and rapid transfer of momentum. The relative deviations versus average generated pressure in the chamber without baffle have been plotted in Fig. 4. 4. RESULTS AND DISCUSSIONS The graph of gas flow versus generated pressure (CDG3) in the chamber without baffle is shown in Fig. 2. It is clear from the graph that its slope ( p ) decreases as q pressure rises. This means that more gas flow is required in order to raise pressure through same increment as we go up the graph. Fig. 3 shows the relation between mean free path (λ) of the gas molecules versus gas flow in the chamber without baffle. The value of λ is calculated from (1) with p as average generated pressure which is the mean of all the CDGs readings. Fig. 4. Relative deviations from the average (%) versus average generated pressure in the chamber without baffle. Fig. 3. Gas flow versus mean free path of the gas molecules in the chamber. A simple explanation to these graphs is that as CDG5 is close to the inlet port and pumping line, it shows high pressure and, hence, maximum deviations than CDG3 & 4. CDG1 & 2 are at extreme ends of the chamber and as the chamber is pumped through bypass line, where CDG1 is near the pumping port, it shows comparatively less pressure than CDG2 which is far away from the pumping port. When baffle plate is placed on the path of the gas molecules, the distribution of gas molecules is changed as shown by their relative deviations in Fig. 5.

(a). Small size baffle these deviations are reducing / becoming almost constant. As discussed above, at 2.5 Pa the value of K n is 0.01 transitional flow exists after which as pressure increases, the flow becomes viscous laminar which is more regular flow and hence less deviations. Since in viscous state, the fluid behaves like a continuous fluid, the deviations are minimizing. This behavior of the gas is clear from all the graphs (Figs. 5 & 4) with and without baffle plates. A comparison of the two cases, with and without baffle (Fig 5 & 4), shows that in the presence of baffle plate, the deviations in the pressure range 0.8 Pa to 10 Pa are less than without baffle case. Furthermore, the data for all the baffles show that these deviations are minimum for the smaller baffle. This means that if we use baffle plate in order to vary pressure distribution in the chamber, the small size baffle (area 132 cm 2 ) will be more suitable in this case. 5. CONCLUSIONS A cylindrical-shaped vacuum chamber of 36.65 l capacity was experimented for pressure uniformity in the range 0.1 Pa to 133 Pa during dynamic gas flow by using three baffle plates of different sizes. It was observed that the small size baffle plate was giving fewer deviations than other two sizes (medium & large). These deviations are specific for this system depending on various factors like gas inlet and outlet ports, gauge position on the chamber, baffle plate size, its position from the gas inlet port etc. From this we conclude that in order to vary pressure distribution in the vacuum chamber during dynamic gas flow, proper size of the baffle plate should be used. REFERENCES (b). Medium size baffle (c). Large size baffle Fig. 5. Relative deviations from the average (%) versus average generated pressure; (a). Small size baffle (b). Medium size baffle (c). Large size baffle A common characteristic observed in all the graphs (with and without baffle) is that; below 2.5 Pa the deviations are maximum while above 2.5 Pa (up to 20 Pa) [1] F. Stanek, J. Tesar, L. Peksa, T. Gronych, P. Repa, Extending the range of pressure generated dynamically up to 100 Pa in a calibration chamber pumped by a turbomolecular pump, Vacuum, vol. 67, pp. 307-310 (2002). [2] P. Repa. Z. Cespiro, L. Peksa, T. Gronych, and J. Tesar, Measurement of pressure differences between various positions in a vacuum chamber where pressure is generated dynamically, Metrologia, vol. 36, pp. 551-554 (1999). [3] S.B. Nesterov, Yu.K. Vassiliev, A.P. Kryukov, Influence of the vacuum chamber shape on the non-uniformity of gas distribution, Vacuum, vol. 53, pp. 193-196 (1999). [4] L. Peksa, T. Gronych, P. Repa, J. Tesar, Measurement of the pressure differences in a large chamber where the pressure is generated dynamically, Vacuum, vol. 67, pp. 333-338 (2002). [5] G. Horikoshi, T. Kuroda and Y Oka, Pressure distribution in a large vacuum chamber with a large gas load and a large pumping speed, Vacuum, vol. 44 (5-7), pp. 617-619 (1993). [6] P.J.Szwemin,N.Niewinski and K.Szymanski, Conductance of orifeces in the spherical and cylindrical chambers of calibration systems, Vacuum, vol. 46 (8-10), pp. 875-878 (1995). [7] Y. Tuzi, M. Kobayashi, and I. Arakawa, Measurement and analysis of anisotropic conditions in a vacuum chamber by a unidirectional pressure gauge, Proceedings of the 14 th International Symposium on Rarefied Gas Dynamics, Japan, 1984. [8] A. Berman, Total Pressure Measurement in Vacuum

Technology, Academic Press, Inc. Orlando, Florida, 1985. [9] Karl Jousten, Handbook of Vacuum Technology, Wiley- Vch Verlag GmbH & Co. KGaA, 2008. [10] Armand Berman, Vacuum Engineering Calculations, Formulas, and Solved Exercises, Academic Press, Inc. 1992. [11] W. Jitschin, G. Reich, Molecular velocity distribution at large Knudsen numbers, J. Vac. Sci. Technol. A, vol. 9(5), 1991. [12] Austin Chamber, Modern Vacuum Physics, Chapman & Hall/CRC, 2005. [13] Shin-Ichi Nishizawa, Masahiro Hirata, DSMC analysis of thermal transpiration of capacitance diaphragm gauge, Vacuum, vol. 67, pp. 301-306 (2002). [14] J.M. Hidalgo, J.L. de Segovia, Uncertainties in calibration using capacitance diaphragm gauges as reference standard, Vacuum, vol. 82, pp. 1503-1506 (2008