GI Series Diaphragm Pressure Gauge Guard

Similar documents
Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Pressure relief valve

Pressure relief valve

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Flowmeter. Original operating manual DFM

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Diaphragm pressure gauge guard MDM 902

PV4 and PV6 Piston Valves

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Instrument Operating Manual

Pressure Relief Valve DHV 718

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

Siphon vessel / Priming aid

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Diaphragm Pressure Keeping Valve

Operating and maintenance manual Filter and reducing station Series / 1.0

Operating Manual VSA100A. tina29e1 ( )

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Installation and Maintenance Instruction Manual

Manual Actuated Boiler Blowdown Valves

OPERATING AND MAINTENANCE MANUAL

Diaphragm relief valve

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating Instructions

Installation, Operation, and Maintenance Manual

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

Installation, Operation, and Maintenance Manual

Interface Devices, Inc. Hydraulic Mini Mule

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Pure-Flo Handwheel Operated Valves (970) Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Installation and Maintenance Instruction Manual

Inverted Bucket Steam Trap IB 16A-7

Engineering Data Sheet

PP-1, PP-1W, PP-2, & PP-3

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Installation, operation & maintenance manual - original version

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Chlorine Supply Containers And Piping

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Installation and Maintenance Instructions for F5509/F6509 Differential Pressure Gauges

PVC Quick Drain Valve

DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301

Installation and Operating Instructions Bypass Flow Meter DST

Instruction Manual Contact Pressure Vacuum Gauge

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Instruction presentation Special valves

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

OFFICINE OROBICHE S.p.A. 1/9

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

553 Series.

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

DTG - LCD Digital Temperature Gauge USER MANUAL

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

CP10 Sensor Installation and Maintenance Instructions

ML3M Monnier Miniature Compressed Air Lubricator

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

FV Flash Vessel Installation and Maintenance Instructions

Operating Instructions Hand Test Pump BHP 700

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Non-Return Valve SRK 22A

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Bermad Pressure Reducing. Model: 42T

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

ITT RICHTER CHEMIE-TECHNIK

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

Magnetic level switch type MR783 Instruction Manual

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

GILMONT ACCUCAL FLOWMETERS

Installation, Operation, and Maintenance Manual

INSTALLATION & MAINTENANCE INSTRUCTION

TECHNICAL DATA. Q= Cv S

Swing Check Valve CB 14 CB 24S CB 26 CB 26A

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

FPD175 Compact orifice carrier assembly

Installation, Operation, and Maintenance Manual

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

MF2M Monnier Miniature Compressed Air Filter

Installation and Maintenance Instruction Manual

TECHNICAL DATA. Q = C v P S

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Transcription:

Diaphragm Pressure Gauge Guard INSTRUCTION MANUAL Please read this Instruction Manual Carefully and Thoroughly for the Correct and Optimum use of this Product. Kindly keep this manual in a convenient place for quick reference.

01 1. About this document Manual : Applies to all series referred to the Installation of the Gauge Isolator Describes safe and proper operation during all operating phases Operating Company : Responsibilities: Always keep this manual accessible where the device is used on the system. Ensure that employees read and observe this document, particularly the safety instructions and warnings, and the documents which also apply. Observe any additional countryspecific rules and regulations that relate to the system. Qualified Personnel Mechanics qualification : Always keep this manual accessible where the device is used on the system. Responsibility : Read, observe and follow this manual and the other applicable documents, especially all safety instructions and warnings. 1.3 Warnings and Symbols Symbol DENGER! Meaning Immediate acute risk Death, serious bodily harm Potentially acute risk Death, serious bodily harm CAUTION! NOTICE SAFETY 1., 2.,... Potentially hazardous situation Minor injury Potentially hazardous situation Material damage Safety warning sign Take note of all information highlighted by the safety warning sign and follow the instructions to avoid injury or death. Instruction Multiplestep instructions Precondition Cross reference Information, notes

2. General safety instructions The manufacturer accepts no liability for damages caused by disregarding any of the documentation or misuse of the equipment 2.1 Intended use The GI Isolator is used for Transmitting Media Pressure to a Pressure Gauge or Pressure Transmitter Use the Isolator to protect the gauge/instrument from the process media. Use the Isolator with a approved pressure gauge Use the Isolator only with solid free media Adhere to the operating limits Install the Isolator in the following manner The Process Connection is connected to the pressurized pipe See Fig 1 (Item #4) The Pressure Gauge/Instrument is mounted into the Upper Bonnet See Fig 1 (Item # 1) 2.2 General safety instructions Read and observe the following regulations before carrying out any work. 2.2.1 Obligations of the operating company Safetyconscious operation Only operate the GI Isolator if it is in perfect technical condition and only use it as intended, ensure that all personnel are aware of safety and risks, and in adherence to the instructions in this manual. Ensure that the following safety aspects are observed and monitored: Intended use Statutory or other safety and accidentprevention regulations Safety regulations governing the handling of hazardous substances Applicable standards and guidelines in the country where the pump is operated Make personal protective equipment available. Qualified personnel Make sure all personnel tasked with work on the GI Isolator have read and understood this manual and all other applicable documents, especially the safety, maintenance and repair information, before they start any work. Organize responsibilities, areas of competence and the supervision of personnel. The following work should be carried out by trained technicians only: Installation, Repair and Maintenance work Work on the electrical system 02

2.2.2 Obligations of personnel Observe the instructions on the Isolator and keep them legible Only carry out work on the fitting if the following requirements are met: System is empty System has been flushed System is depressurized System has cooled down System is secured against being switched back on again Do not make any modifications to the device 2.3 Hazardous media When handling hazardous media (e.g. hot, flammable, explosive, toxic, hazardous to health or the environment), observe the safety regulations for the handling of hazardous substances. Use personal protective equipment when carrying out any work on the GI series isolator. 3. Layout and Function 1 2 3 1 Pressure gauge Connection 1/4" NPT 2 Upper Bonnet 3 Process Diaphragm 4 Lower Process Connection 1/2" Fig 1 4 Description The fitting is a diaphragm pressure gauge guard The fitting is mounted with the bottom section facing the pressurized pipe carrying the medium. The pressure gauge is mounted on the upper part. The separation diaphragm transmits the media pressure to the pressure gauge via a transmitter fluid. Separation Diaphragm: FPM or PTFE Bonded EPDM Diaphragm Seal Mounting Position: Any Pressure Instrument or Gauge Preferably in an Upright Positon 03

04 4. Transport, Storage and Disposal Unpacking and inspection on delivery 1. Unpack the when received and inspect it for damage that may have occurred during transportation 2. Report any damage to the manufacturer immediately. 3. For immediate installation, dispose of packaging material according to local regulations. Storage Material damage due to inappropriate storage! NOTICE Store the fitting properly. 1. Make sure the storage room meets the following conditions: Dry Frostfree Vibrationfree Not in direct sunlight Storage temperature +10 C to +60 C Disposal Plastic parts can be contaminated by poisonous or radioactive media to such an extent that cleaning will not be sufficient. Risk of poisoning and environmental damage from medium. Use personal protective equipment when carrying out any work on the fitting. Before disposing of the fitting: Collect escaping medium and dispose separately according to local regulations. Neutralize residues of medium in the fitting. Remove plastic parts and dispose of them in accordance with local regulations. Dispose of fitting in accordance with local regulations. 5. Installation and connection Preparing for installation Check operating conditions 1. Ensure the Isolator is suitable for the purpose intended: Materials used ( Type plate). Medium( Order and design data). 2. Ensure the required operating conditions are met: Resistance of the materials of the body, process diaphragm a to the medium ( Check Chemical Resistance Guide).

Materials used ( Type plate). Medium ( Order and design data). 2. Ensure the Required Operating conditions are met: Chemical Resistance of the materials of the body, separation diaphragm and seals to the medium ( Check Chemical Resistance Guide). Media temperature ( Data sheet). Operating pressure ( Data sheet). 3. Consult with the manufacturer regarding any other use of the device. Check the Installed Condition of the Isolator Check the installed condition of the fitting and depending on the situation proceed as follows: Ensure Isolator has been properly filled with the transmitter fluid and pressure gauge has been installed properly Planning pipelines Risk of poisoning and environmental damage from medium. Leaks due to impermissible pipework forces. Ensure that the fitting is not subject to any pulling or thrusting forces or bending moments. 1. Plan pipes safely: No pulling or thrusting forces No bending moments Adjust for changes in length due to temperature changes (compensators, expansion shanks) Optional flow direction Optional installation position and direction Installing the fitting Before installation in the pipeline, the Isolator must be filled and the pressure gauge must be filled and mounted. Follow the section drawing for assembly Use the recommended transmitter fluid Fill the fitting The fitting must be filled The compressed air supply must be available 1. Fill the upper chamber(item #2) with suitable transmitter fluid. Ensure there are no air bubbles trapped inside chamber 05

06 NOTICE Damage to the Process Diaphragm due to lack of Transmitter Fluid! Before commissioning, make sure that the isolator is Sufficiently Filled with Transmitter Fluid. Damage to the Process Diaphragm Using Compressed Air! Apply Compressed Air to the fitting only for Very Short Periods of time. When doing so, do not exceed the permissible pressure of the pressure gauge that is used. 2. 3. 4. 5. 6. 7. 8. 9. Screw the Pressure Gauge (1) Clockwise into the Upper Chamber (2). Rotate the Fitting until the Pressure Gauge (1) is Facing Vertically Downwards. Connect the Compressed Air supply to the Process Connection (Bottom Section) (6). Switch on the Compressed Air Supply and Apply Compressed Air to the Isolator for a Short Period (Short Burst) of time. This will ensure the Transmitter Fluid is Forced into the Bourdon Tube Switch Off the Compressed Air Supply and Carefully Detach it from the Isolator. Rotate the Isolator until the Pressure Gauge (1) is in the Upright Position. Unscrew the Pressure Gauge (1) from the Upper Chamber (2). Check the Fill Level in the Upper Chamber (2) and Depending on the Liquid Level proceed as Follows: If the fill level is Sufficient Liquid Level at Top of Upper Chamber Continue with Process. OR If the Fill Level is Too low: Top Up the Transmitter Fluid (4) in the Upper Chamber (2). Repeat Steps 29 10. Check the Thread Seal to ensure there are no leaks G Type or BSP: Ensure that the Oring Seal in Located within the Upper Chamber (See Item 3). OR NPT Thread: If Necessary Wrap Sealing Tape Around the Thread of the Pressure Gauge (1). 11. Screw the Pressure Gauge Clockwise into the Upper Chamber (2) 12. Ensure the Pressure Gauge is Zeroed. The Isolator is Now Ready to be Installed Installing Isolator into Piping Sytem The Pressure Gauge Must Be Mounted on the Isolator The Isolator Must Be Filled with the Transmitter Fluid. The Bourdon Tube of the Pressure Gauge Must Be Filled with the Liquid Transmitter Fluid. Risk of Injury or Environmental Damage from Liquid Media. Leak due to faulty installation. Installation should only be performed by technicians who have been properly trained 1. 2. Align the Isolator together with the pressure gauge, preferably in a upwards position Install the Isolator into Piping System Perform Hydrostatic Test Performing the Hydrostatic Test Mandatory 1. 2. Pressure Test using Neutral Medium, e.g. Water. Pressurize the fitting ensuring Test pressure < Permissible System Pressure Check the for leaks

07 6. Troubleshooting Risk of Injury Due to Hazardous or Hot Process Media. Use personal protective equipment when carrying out any work on the fitting. Safely collect the media and dispose of it in accordance with environmental regulations. Consult with the manufacturer regarding faults which are not identified in the following table, or which cannot be traced to the indicated causes. Error Incorrect Measurement value Medium in the transmitter fluid Medium is leaking Possible cause Air bubbles in the transmitter fluid Defective separation diaphragm Defective seal Corrective action Check that the fitting is sufficiently filled with transmitter fluid, top it up if necessary Change the process diaphragm Check the seal at the connection to the pipeline and tighten or replace 7. Appendix Technical data Dimensions C 3.38" 10 20 0 D 30 2 1 3 0 4 2.3" 60 40 50 1 2 3 4 5 6 PARTS No. Part Materials 1 Pressure Gauge PP 316 SS 2 Bonnet PPG PVDF 3 ORing FPM* 4 Liquid Fill Glycerin Silicone 5 Diaphragm PTFE Bonded EPDM 6 Lower Chamber PVC PPG PVDF * For GType Thread Only OPTIONAL GAUGES Truflo offers the gauges listed below mounted to isolator and prefilled with glycerin, silicone or special fluid for chlorine applications. Truflo gauges have a PP plastic housing and the cases are n or mal ly filled with either glycerin or silicone for corrosion resistance and dampening. Truflo gauge isolators are not recommended for vacuum applications. OTHER OPTIONS Flanged Process Connections DIMENSIONS (INCHES) Gauge Diameter Item No. Gauge Connection Housing Bourdon Tube Window Accuracy Dimensions 2½" OBSxx ¼" PP 316 SS Polycarbonate ±0.75% of span 3.6 3.1 2½" DoubleSided OBSDGOxx ¼" PP 316 SS Polycarbonate ±0.75% of span 3.6 3.1 2½" Back Mount OBSxx ¼" PP 316 SS Polycarbonate ±0.75% of span 3.6 3.1 4½" OBS4xx ¼" PP 316 SS Polycarbonate ±0.5% of span 6.0 6..0 C D(max.) xx denotes the maximum gauge pressure i.e., 30 / 60 / 100 / 160 psi. See data page for recommended working pressures. Other Ranges are available

07 Upper Chamber Liquid Fill Icon recommends the following Liquid Transmitter Fluids for Upper Chamber Transmitter Fluid Glycol (ethylene glycol) Glycerin Silicone Antifreeze (such as Glysantine or Aral Antifreeze) Demineralized water*\ Halo Carbon Tightening Torques Description Pressure gauge Upper Chamber Process Connection Torque HandTight, 22 ftlbs HandTight WORKING PRESSURES (psi) *(NonShock) WEIGHTS Material PVC PP PVDF 10 20 C 50 68 F 30 C 86 F 100 125 40 C 104 F 80 100 50 C 122 F 45 80 125 60 C 140 F Temperature Ranges : PVC 0 to 60 C (32 to 140 F) / PP 10 to 80 C (50 to 176 F) / PVDF 30 to 120 C ( 22 to 248 F) 15 65 105 70 C 158 F 45 85 80 C 176 F 70 90 C 194 F 60 100 C 212 F 45 120 C 248 F 30 Net Weights Pounds 3 1.0 0.7 1.3