Comparison of stepped and smooth spillway effects on stream reaeration

Similar documents
International Journal of Civil Engineering and Technology (IJCIET), ISSN (Print), AND TECHNOLOGY (IJCIET)

Stability of Concrete Macro-Roughness Linings for Overflow Protection of Earth Embankment Dams ( 1 ) - Discussion

AIR-WATER FLOW STRUCTURES AT AN ABRUPT DROP WITH SUPERCRITICAL FLOW

Evaluation of step s slope on energy dissipation in stepped spillway

A Comparative Study of Self-aerated Stepped Spillway and Smooth Invert Chute Flow: The effect of Step-induced Macro-roughness

Hydraulics of stepped spillways : current status

International Journal of Scientific & Engineering Research, Volume 5, Issue 1, January ISSN

InvestigatingThe Effect of Number of Steps on Energy Dissipation of Stepped Spillways Based on the New Design Approach.

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

Flow Characteristics and Energy Dissipation Over Traditional and Stepped Spillway with Semicircular Crest

Modeling Turbulent Entrainment of Air at a Free Surface C.W. Hirt 5/24/12 Flow Science, Inc.

Transitional Steps Zone in Steeply Sloping Stepped Spillways

Discharge Coefficient in Siphon Spillway with Different Cross Sections

SUPERCRITICAL FLOW AT AN ABRUPT DROP : FLOW PATTERNS AND AERATION

Investigation of Cavitation Damage Levels on Spillways

EXPERIMENTAL STUDY OF ENERGY DISSIPATION OVER STEPPED GABION SPILLWAYS WITH LOW HEIGHTS *

Exercise (3): Open Channel Flow Rapidly Varied Flow

Effect of channel slope on flow characteristics of undular hydraulic jumps

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

Total Dissolved Gas Properties and Processes. by Mike Schneider US Army Corps of Engineers Engineer Research and Development Center

Predicting Oxygen Content Downstream of Weirs, Spillways and Waterways

Air Entrainment and Scale Effects in Hydraulic Jumps with Small Froude Numbers

Advanced Hydraulics Prof. Dr. Suresh A. Kartha Department of Civil Engineering Indian Institute of Technology, Guwahati

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

Experimental Investigation on Changes of Water Surface Profile with Gaussian Shaped Bottom and Side Roughness

EFFECT OF USING DENTATE SKI JUMP SPILLWAYS ON SCOURING PROFILE

INTERFACE AREA IN SELF-AERATED FLOWS

Experiment (13): Flow channel

DAIVÕES DAM SPILLWAY: A NOVEL SOLUTION FOR THE STILLING BASIN

ANSWERS TO QUESTIONS IN THE NOTES AUTUMN 2018

Computerized Simulation Hydraulic Behavior of Shaft Spill way with vortex breaker on crest & Semi long stepped chamber throat

IMPROVING PLANT AERATION USING GAS INFUSION TECHNOLOGY

Irrigation &Hydraulics Department lb / ft to kg/lit.

Advanced Hydraulics Prof. Dr. Suresh A. Kartha Department of Civil Engineering Indian Institute of Technology, Guwahati

Free Surface Flow Simulation with ACUSIM in the Water Industry

Optimum Design of Stepped Spillways Using Genetic Algorithm

The effect of two inclined circular plunging jets on air entrainment in an aeration tank

The activated sludge process

Plane Turbulent Wall Jets in Limited Tailwater Depth

EXAMPLES (OPEN-CHANNEL FLOW) AUTUMN 2018

Civil Engineering Journal

COST EFFECTIVE STORAGE CAPACITY INCREASE FOR ALUMINA TAILINGS DISPOSAL AREA THROUGH SPILLWAY OPTIMISATION

HYDRAULIC JUMP AND WEIR FLOW

Impact of anti-vortex blade position on discharge experimental study on the coefficient of morning glory spillway

The Hydraulic Design of an Arced Labyrinth Weir at Isabella Dam

IMPACT OF MAKING THE CREST OF WEIR MULTIFACETED ON DISCHARGE COEFFICIENT OF MORNING GLORY SPILLWAY

Plane Turbulent Wall Jets in Limited Tailwater Depth

IMPROVING THE SAFETY OF AN OLD AUSTRIAN DAM ABSTRACT

Components of a Barrage

Experimental Investigation of Clear-Water Local Scour at Pile Groups

Options for Reducing Total Dissolved Gas at the Long Lake Hydroelectric Facility. Northwest Hydraulic Consultants Inc, Seattle, Washington, USA

3D NUMERICAL MODELLING OF THE CAPACITY FOR A PARTIALLY PRESSURIZED SPILLWAY

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

Experimental Investigation Of Flow Past A Rough Surfaced Cylinder

Effects of wind incidence angle on wind pressure distribution on square plan tall buildings

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle

Spillway Deflector Design Using Physical and Numerical Models

WAVE OVERTOPPING AND RUBBLE MOUND STABILITY UNDER COMBINED LOADING OF WAVES AND CURRENT

DESIGN OF BELL-MOUTH SPILLWAY AT BARVI DAM

NUMERICAL INVESTIGATION ON WATER DISCHARGE CAPABILITY OF SLUICE CAISSON OF TIDAL POWER PLANT

Greenup Lock Filling and Emptying System Study

Transactions on Ecology and the Environment vol 12, 1996 WIT Press, ISSN

Wind Flow Validation Summary

PLUNGING JET CHARACTERISTICS OF PLUNGING BREAKERS

Air Bubble Departure on a Superhydrophobic Surface

Numerical Fluid Analysis of a Variable Geometry Compressor for Use in a Turbocharger

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

USING A LABYRINTH WEIR TO INCREASE HYDRAULIC CAPACITY. Dustin Mortensen, P.E. 1 Jake Eckersley, P.E. 1

Development of High-speed Gas Dissolution Device

Hours / 100 Marks Seat No.

Hydraulic Modeling to Aid TDG Abatement at Boundary and Cabinet Gorge Dams

CFD AND EXPERIMENTAL STUDY OF AERODYNAMIC DEGRADATION OF ICED AIRFOILS

Australian Journal of Basic and Applied Sciences

DAM BREAK WAVE WITH ENERGY DISSIPATION : TWO CASE STUDIES

Spillway with improved dissipation efficiency - side dissipation beams

Grit chambers are basin to remove the inorganic particles to prevent damage to the pumps, and to prevent their accumulation in sludge digestors.

Experimental investigation on air entrainment below impinging jets by means of video observations and image processing

STRUCTURAL STABILITY ASSESSMENT

ENVE 301 Environmental Engineering Unit Operations

Design of Spillway Upgrades

NUMERICAL AND PHYSICAL MODELING

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 1, 2012

Numerical investigation of transition between free surface flow and pressurized flow for a circular pipe flowing full upstream

(Refer Slide Time: 2:16)

Experimental Study of Sequent Depths Ratio of Hydraulic Jump in Sloped Trapezoidal Chanel

2O-2 Open Channel Flow

BEACH EROSION COUNTERMEASURE USING NEW ARTIFICIAL REEF BLOCKS

Designing Labyrinth Spillways for Less than Ideal Conditions Real World Application of Laboratory Design Methods

LABORATORY EXPERIMENTS ON WAVE OVERTOPPING OVER SMOOTH AND STEPPED GENTLE SLOPE SEAWALLS

Course Teacher: Prof. Dr. M. R. Kabir SPILLWAY & IRRIGATION PUMPS. Spillway:

Analyzing a Malfunctioning Clarifier with COMSOL s Mixture Model

Transition Submergence and Hysteresis Effects in Three-Foot Cutthroat Flumes

Evaluating the Spillway Capacity of the Morning Glory Spillway at Harriman Dam

FREE OVERFALL IN A HORIZONTAL SMOOTH RECTANGULAR CHANNEL

Scour Investigations Behind a Vertical Sluice Gate without Apron.

CROSS-SHORE SEDIMENT PROCESSES

Study on Distribution Characteristics and Mitigation Measures of Dissolved Oxygen Super-saturation in the Lower Reaches of High Dam

MEMORANDUM. TNC Fisher Slough Final Design and Permitting Subject: DRAFT Technical Memorandum: Levee Emergency Spillway Design

PARAMETRIZATION OF WAVE TRANSFORMATION ABOVE SUBMERGED BAR BASED ON PHYSICAL AND NUMERICAL TESTS

Energy and mass transfer in gas-liquid reactors.

Transcription:

Comparison of stepped and smooth spillway effects on stream reaeration Egemen Aras 1* and Mehmet Berkun 2 1 Gumushane University, Department of Civil Engineering, Gumushane 29100, Turkey 2 Karadeniz Technical University, Department of Civil Engineering, Trabzon 61080, Turkey Abstract The oxygen transfer at a hydraulic structure happens by self-aeration through the spillway and by flow aeration in the hydraulic jump downstream of the hydraulic structure. Spillways with their water-air controlling mechanisms are important not only for their structural properties but also for their effects on stream ecology. Spillway types also affect the efficiency of aeration. Decisions on the types of spillway should be made by taking the environmental conditions and flow rates into consideration. This paper compares the aeration efficiency of stepped and smooth spillways. Empirical correlations predicting length of the non-aerated flow region and aeration efficiency are developed. Smooth and stepped spillways cause increased dissolved oxygen (DO) concentrations at the downstream part of the channel. DO concentration changes are shown to depend on the flow types, discharge rates, tail-water depth and travelling times. Keywords: dissolved oxygen, spillway, stream, re-aeration, aeration efficiency Introduction Air entrainment on spillways and chutes has recently been recognised for its contribution to the air-water transfer of atmospheric gases such as oxygen and nitrogen. This process must be taken into account for the re-oxygenation of polluted streams and rivers, but also to explain the high fish mortality downstream of large hydraulic structures. In rivers, artificial stepped cascades and weirs are introduced to enhance the dissolved oxygen (DO) content of polluted or eutrophic streams (Frizell, 1992; Toombes and Chanson, 2000). With large dams, the downstream nitrogen content is another important parameter since nitrogen super-saturation may increase the mortality of some fish species (Orlins and Gulliver, 1997). On stepped spillways, both the aeration of the flow and the strong turbulent mixing enhance the air-water transfer of chemicals (Brattberg and Chanson, 1998; Baylar et al., 2007). The strong turbulent mixing increases the coefficient of transfer in comparison with a quiescent fluid, and the large amount of entrained air bubbles increase the air-water interface area due to the cumulative bubble surface areas (Chen at al., 2000; Pfister et al., 2006). A DO deficit upstream of a structure of greater than 2.5 mg/l is normally required for accuracy in oxygen transfer efficiency measurement. The primary source of measurement uncertainty is found to be in the oxygen saturation concentration. In the summer time, when the average saturation concentration is about 7 mg/l in most areas, this specification results in an upstream DO of less than 4.5 mg/l (Baylar et al., 2006; Carosi and Chanson, 2008). The objective of this study was to investigate the effects of aeration caused by smooth and stepped spillways, in a laboratory model channel, and in relation to flow type, discharge rate, tail-water depth and channel slope. * To whom all correspondence should be addressed. +90 462 377 3547; fax: +90 462 377 2606; e-mail: egemen@ktu.edu.tr Received 5 June 2009; accepted in revised form 11 March 2010. Air entrainment on stepped spillways The flow conditions on a stepped channel are characterised by a high level of turbulence. Air entrainment is caused by turbulence velocities acting next to the air-water free surface. Through this interface, air is continuously trapped and released. Air entrainment occurs when the turbulent kinetic energy is large enough to overcome both surface tension and gravity effects. The turbulent velocity normal to the free surface V must overcome the surface tension pressure, and is greater than the bubble rise velocity component for the bubbles to be carried away. These conditions are: V 8 d w ab V U r cos where: σ is the surface tension ρ w is the water density d ab is the air bubble diameter U r is the bubble rise velocity α is the channel slope Air entrainment occurs when the turbulent velocity V satisfies both Eqs. (1) and (2) (Chanson, 1994). Aeration on steps With a stepped cascade, low overflows result in a succession of free-falling nappes. The flowing waters bounce from one step to the next one as a series of small free falls. This flow situation is defined as a nappe flow regime. Stepped channels with nappe flows may be analysed as a succession of drop structures. For large discharges, the waters flow down a stepped channel as a coherent stream, skimming over the steps. In the skimming flow regime, the external edges of the steps form a pseudo-bottom over which the water skims. (1) (2) 309

Effects of aeration a. Nappe flow regime b. Skimming flow regime Figure 1 Aeration on stepped spillway Beneath the pseudo-bottom, recirculating vortices develop, filling the zone between the main flow and the steps. The vortices are maintained through the transmission of shear stress from the fluid flowing past the edges of the steps. Considering a stepped chute with nappe flow regime, air is entrained at each step by a plunging jet mechanism at the intersection of the over falling jet and the receiving waters, and at the toe of the hydraulic jump (Fig. 1a). With deep-pooled steps, most of the air is entrained by the plunging jet mechanism. For flat steps with shallow waters, most of the air is entrained at the toe of the hydraulic jump. The air entrainment characteristics of hydraulic jumps have been analysed by a number of researchers (Sene, 1988; Chanson, 1995; Kokpinar, 1996; Emiroglu and Baylar, 2005) On a stepped spillway with skimming flow, the entraining region follows a region where the flow over the spillway is smooth and glassy. Next to the boundary, however, turbulence is generated and the boundary layer grows until the outer edge of the boundary layer reaches the surface. When the outer edge of the boundary layer reaches the free surface, the turbulence can initiate natural free surface aeration. The location of the start of air entrainment is called the point of inception. Downstream of the inception point of free-surface aeration, the flow becomes rapidly aerated and the free surface appears white. Far downstream the flow will become uniform and for a given discharge any measure of flow depth, air concentration and velocity distribution will not vary along the chute. This region is defined as the uniform equilibrium flow region (Fig. 1b). In supercritical flows above chutes and spillways, the amount of entrained air is an important design parameter. Self-aeration is initially effective because of the effects of the entrained air volume of the flow. Air entrainment increases the bulk of the flow which is a determining parameter of the height of spillway sidewalls. The presence of air within the boundary layer also reduces the shear stress between the flow layers and hence the shear force. The resulting increase of flow momentum must be taken into account when designing a ski jump and stilling basin downstream of a spillway, a stepped spillway or a rock-fill dam with possible overtopping (Gonzalez, 2005). Further presence of air within high-velocity flows may prevent or reduce the damage caused by cavitation erosion which may occur on stepped spillways. But the risks of cavitation damage are reduced by the flow aeration. Peterka (1953) and Russell and Sheehan (1974) showed that 4% to 8% of air concentration next to the spillway bottom may prevent cavitation damage on concrete surfaces. On stepped spillways, the high rate of energy dissipation reduces the flow momentum in comparison with a smooth chute. The reduction of flow velocity and the resulting increase of flow depth also reduce the risks of cavitation as the cavitation index increases (Chanson, 1994; Peyras et al., 1992). The flow bulking is estimated from the total quantity of air entrained while the prevention of cavitation damage requires the knowledge of the air concentration in the layers close to the spillway bottom. Reduction of drag observed with the air entrainment will reduce the energy dissipation above the spillway and hence its efficiency. It must be emphasised that the reduction of the friction factor observed with increasing mean air concentration is not completely understood. The presence of bubbles across the flow and the bubble size distribution is expected to affect the turbulence and the turbulent mixing mechanisms (Chanson, 1997). Stream reaeration One of the most important water quality parameters in rivers and streams is the DO content. The oxygen concentration is a prime indicator of the quality of the water. Dams and weirs across a stream affect the air-water gas transfer dynamics. Deep and slow pools of water upstream of a dam reduce the gas transfer process and the natural re-aeration as compared to an open river. But some hydraulic structures (e.g. spillway, stilling basin) can enhance the oxygen transfer during water releases (Aras and Berkun, 2008) Organic waste from municipal, agricultural and industrial sources may overload the natural system, causing a serious depletion of the oxygen supply in the water. Water rich in nutrients produces algae in quantities which upon decomposition deplete the oxygen supply. Fish kills are often associated with this process of eutrophication. Habitats for warm-water fish populations should contain DO concentrations of not less than 4.0 mg/l; habitats for cold-water fish populations should not be less than 5.0 mg/l (Berkun and Onal, 2004). On stepped spillways, both the aeration of the flow and the strong turbulent mixing enhance the air-water transfer of chemicals. The chemicals can be atmospheric gases or polluted matters. The strong turbulent mixing increases the coefficient of transfer in comparison with a quiescent fluid, and the large amount of entrained air bubbles increases the air-water interface area due to the cumulative bubble surface areas. Overall 310

gas transfer at cascades and overflow weirs can be measured by the deficit ratio (r) defined as: CDS CUS 1 E 1 (3) CS CUS r where: E is the aeration efficiency C US is the upstream dissolved gas concentration C DS is the dissolved gas concentration at the downstream end of the channel C S is the saturation concentration r is deficit ratio Main Water Tank An upstream DO deficit of greater than 2.5 mg/l is normally required for accuracy in oxygen transfer efficiency measurement. The primary source of measurement uncertainty was found to be the uncertainty in the oxygen saturation concentration. In the summer time, when the average saturation concentration is about 7 mg/l in most areas, this specification results in an upstream DO of less than 4.5 mg/l. For comparability of measurement results, aeration efficiency is usually standard under a particular temperature. This reference temperature shall be taken as 20ºC: Pipe Water Discharge Regulating Filter Spillway Tailwater Depth Channel Probe DO Meter Figure 2 The experimental system Discharge Scale Exit E 1 E 20 1 1/ ft (4) f T T 20 8.261x10 5 T 20 2 1.0 0.02103 (5) where E 20 is the aeration efficiency at 20ºC T is the temperature f T is the coefficient-related temperature Figure 3 Smooth and stepped spillways and channel profiles Materials and methods A stepped spillway with a height of 13.5 cm, length of 12 cm and width of 10 cm with 4 steps was used for the experiment. A smooth spillway with a height of 10 cm, length of 15 cm and width of 10 cm was also tested. Three meters of channel length was provided downstream of the crest. Both the approach channel and the tail channel had the same width (10 cm) as the spillway (Fig. 2). Water flowed from the main tank to the channel. There was no special reason for the choice of this channel width. Dimensions were kept constant to make an accurate comparison. In the upstream portion of the spillway, DO concentration during testing was 6.5 mg/l and water temperature was 10ºC. Saturation concentration was 11.3 mg/l at 10ºC. It was not necessary to add any chemicals to the water because the difference was greater than 2.5 mg/l. Dissolved oxygen concentration was measured upstream of the spillway (A) and at 4 different points (B, C, D, E) downstream of the spillway (Fig. 3). The discharge of the spillway was 0.10, 0.15, 0.20, 0.32, 0.40 l/s, respectively. Dissolved oxygen concentration was measured by a DO meter (Hach HQ10) (Aras, 2009). Result and discussion The results are presented in Figs. 4 to 12. The comparison between E 20 -discharge on smooth and stepped spillways is Figure 4 Discharge-E 20 relationship on smooth spillway presented in Figs. 4 to 7. In Figs. 8 and 9, the effect of discharge on DO% was investigated. The relationship between E 20 and tailwater depth (h M ) for the spillways is shown in Figs. 10 and 11. Finally, average DO% is compared for the spillways in Fig. 12. Figures 4 to 7 show that E 20 increased with discharge on the 2 spillway types. The E 20 value varies between 1.35 and 1.90 on smooth spillways and between 1.40 and 1.95 on stepped spillways. A higher aeration was observed on the stepped spillway, because surface aeration, plunging jet aeration and hydraulic jump aeration occurred on the stepped spillway. E 20 values rose most sharply for discharges between 0.32 l/s and 0.40 l/s. In the same way, %DO increased with discharge. Supersaturation was seen on both spillway types, with DO above 100%. 311

Figure 5 Discharge-E 20 relationship on stepped spillway Figure 9 %DO downstream of stepped spillway Figure 6 Comparison of E 20 on the spillways Figure 10 Relationship between E 20 and tail-water depth (h m ) on smooth spillway Figure 7 Comparison of E 20 (mean) and discharge on the spillways Figure 11 Relationship between E 20 and tail-water depth (h m ) on stepped spillway Figure 8 %DO downstream of smooth spillway Figure 12 Comparison of mean %DO on the spillways 312

Tail-water depth has little effect on the aeration efficiency on the spillways. E 20 increased with tailwater depth. Tailwater depth varied between 0.02 m and 0.03 m. Therefore, the tailwater effect on aeration was seen to be more important for the smooth spillway. Spillway type, discharge rates, tail-water depth and flow types affect the aeration efficiency along the channel length. In both nappe and skimming flow regimes, the air-water gas transfer taking place above a stepped chute is enhanced by the strong turbulent mixing and flow caused by aeration. Aeration caused by the flow must be taken into account for the reoxygenation of polluted streams and rivers. The flow patterns of a stepped spillway and smooth spillway have varying hydraulic characteristics. The hydraulic characteristics, flow-caused aeration and hydrodynamic interactions between the flow and the steps must be taken into account. Two distinct flow regimes on stepped spillways are nappe and skimming flows. In nappe flow, the steps act as a series of over-falls with the water plunging from one step to another. Water flows as a coherent stream over the pseudo-bottom formed by the outer step edges. The flow is without air pockets under the jets in skimming flow. In the experiments, nappe flow with low discharges (0.10, 0.15, 0.20 l/s) and skimming flow with high discharges (0.32 and 0.40 l/s) occurred. The results of our experimental study indicate that the aeration efficiency of nappe flows is primarily a function of the discharge and channel length. The oxygen transfer increases with increasing chute length. In skimming flow conditions, aeration efficiency is nearly zero as long as no free-surface aeration occurs. Tail-water depth has little effect on the aeration efficiency of skimming flows. Smooth spillway aeration caused lower aeration efficiencies, depending on travel time, discharge rate and tail-water depth, than the stepped spillway (Figs. 4 to12) (Aras, 2009). Conclusions In both nappe and skimming flow regimes, the air-water gas transfer taking place above a stepped chute is enhanced by the strong turbulent mixing and by the aeration of the flow. The flow aeration must be taken into account for the re-oxygenation of polluted streams and rivers, but also to explain the high fish mortality downstream of large hydraulic structures. As the flow patterns of stepped channel flows are very different from smooth chute flow situations, designers must select the appropriate flow regime and carefully analyse the stepped channel flows. Designers must take into account the hydraulic characteristics, the flow aeration and the hydrodynamic interactions between the flow and the steps. Dissolved oxygen concentrations and aeration efficiency along the spillway channel increase with increasing flow rates, for smooth and stepped spillways. Aeration efficiency of the stepped spillway is higher than the smooth-crested spillway along the channel, for the same flow rates. Tail-water depth has little effect on aeration efficiency on both smooth and stepped spillway. E 20 increases with increasing tail-water depth. Acknowledgements Related research was supported by the Research Funds of Karadeniz Technical University Project No. 20.112.001.5 and Project No. 21.112.001.1. References ARAS E (2009) Effects of Aeration through the Hydraulic Structures on Dissolved Oxygen Balance in Rivers and on the Optimization of Wastewater Treatment System (in Turkish). PhD Thesis, Karadeniz Technical University, Department of Civil Engineering, Trabzon, Turkey. ARAS E and BERKUN M (2008) Spillway and metal toxicity influenced stream reaeration. J. Environ. Eng. ASCE 134 (9) 809-811. BAYLAR A, EMIROGLU ME and BAGATUR T (2006) An experimental investigation of aeration performance in stepped spillways. Water Environ. J. 20 (1) 35-42. BAYLAR A, BAGATUR T and EMIROGLU ME (2007) Aeration efficiency with nappe flow over stepped cascades. Proc. Inst. Civil Eng.-Water Manage. 160 (1) 43-50. BERKUN M and ONAL A (2004) Effects of inorganic metals on respirometric oxygen uptake and related sag curve formations in streams. Water SA 30 (2) 273-278. BRATTBERG T and CHANSON H (1998) Air entrapment and air bubble dispersion at two dimensional plunging water jet. Chem. Eng. Sci. 53 (24) 4113-4127. CAROSI G and CHANSON H (2008) Turbulence characteristics in skimming flows on stepped spillways. Can. J. of Civil Eng. 35 (9) 865-880. CHANSON H (1994) Hydraulic Design of Stepped Cascade, Channels, Weirs and Spillways. Elsevier Science Ltd., Oxford, England. CHANSON H (1995) Air-water gas transfer at hydraulic jump with partially developed inflow. Water Resour. Res. 29 (10) 2247-2254. CHANSON H (1997) Air bubble entrainment in open channels: flow structure and bubble size distributions. Int. J. Multıphase Flow 23 (1) 193-203. CHEN GH, LEONG MI, LIU J, HUANG JC, LO IMC and YEN BC (2000). Oxygen deficit determinations for major river in eastern Hong Kong, China. Chemosphere 41 7-13. EMIROGLU ME and BAYLAR A (2005) Influence of included angle and sill slope on air entrainment of triangular planform labyrinth weirs. J. Hydraul. Eng. 131 (3) 184-189. FRIZELL KH (1992) Hydraulics of stepped spillways for RCC dams and dam rehabilitation. Proc.3 rd Specialty Conf. on Roller Compacted Concrete, ASCE, San Diego, USA. p. 423-439 GONZALEZ CA (2005) An Experimental Study of Free-Surface Aeration on Embankment Stepped Chutes. PhD Thesis, Department of Civil Engineering, The University of Queensland. KOKPINAR MA (1996) Air Entrainment in High Speed Free Surface Flows. PhD Thesis, Middle East Technical University, Turkey. ORLINS JJ and GULLIVER JS (1997) Prediction of dissolved gas concentrations downstream of a spillway. Proc. XXVII. IAHR Congr., New York. p. 524-529. PETERKA AJ (1953) The effect of entrained air on cavitation pitting. Joint Meeting Paper, IAHR/ASCE, Minneapolis, Minnesota. 507-518. PEYRAS L, ROYET P and DEGOUTTE G (1992) Flow and energy dissipation over stepped gabion weirs. J. Hydraul. Eng. 118 (5) 707-717. PFISTER M, HAGER WH and MINOR HE (2006) Bottom aeration of stepped spillways. J. Hydraul. Eng. 132 (8) 850-853. RUSSELL SO and SHEEHAN GJ (1974) Effect of entrained air on cavitation damage. Can. J. Civil Eng. 1 97-107. SENE KJ (1988) Air entrainment by plunging jets. Chem. Eng. Sci. 43 2615-2623. TOOMBES L and CHANSON H (2000) Air-water flow and gas transfer at aeration cascades: A comparative study of smooth and stepped chutes. Proc. International Workshop on Hydraulics of Stepped Spillways, Balkema, Rotterdam, The Netherlands. 77-84. 313

314