Infrared Linescanners

Similar documents
Pneumatic spool valve islands

INSTRUCTION MANUAL Pressure Relief Device LPT

Columbus Instruments

IECEx Certificate of Conformity Annexe

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Air Differentail Pressure Switch

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Types and approvals. Page 1/6. Data Sheet

FLAMMABLE GAS SENSOR/TRANSMITTER

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SITRANS P measuring instruments for pressure

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

C-Flow Coriolis Mass Flow Meters

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Model PDT Dewpoint Transmitter

PyroCouple Series Operators Guide

Electro-Pneumatic Converter YT-940 SERIES

Level transmitter LT 100

IP65 Air Differential Pressure Switch

44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

4/2 way Pneumatic Solenoid Valve

Pneumatic pressure switch 20DD

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

ATS430 turbidity sensor Retractable insertion assembly

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Armatures for analytical probes

Pressure transmitter PASCAL Ci4

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Pressure switch and Thermostat CAS

3M Telecommunications Solutions for Networks. Quante QSA (= LSA plus) System Catalogue. Innovation

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Pressure Measurement Single-range transmitters for general applications

BUBBLER CONTROL SYSTEM

Series Environmental Chambers

200 PSI COMPRESSORS - MODEL NUMBERS

Type 4708 Supply Pressure Regulator

Technical Information Cleanfit CUA451

IMPORTANT SAFETY INSTRUCTIONS

steel wire cable tray system accessories

SOLENOID VALVES AND PNEUMATIC VALVES

100C Air Compressor Kit

Proportional pressure regulators VPPE

B84G - Excelon Plus Modular System General purpose filter/regulator

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Operating Instructions

Precision pressure sensor Basic version Model CPT6020

Prewired position switches FA series

3-Way Safety Block DSV

Mass Flow Meter (MFM) for gases

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

UNDERSTANDING, ACCELERATED

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Pressure Automated Calibration Equipment

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Junction Boxes Series 8118

General Specifications

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Position switches FP series

L3 Pressure and Level transmitter

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

SonoSelect 10 and SonoSafe 10 energy meters

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

Type 4708 Supply Pressure Regulator

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

A-100, AD, CD, CD2M and PD Membrane level indicator for solids. Operating Instructions. Safety instructions Operating instructions

CATALOGUE // The Fort Vale Range of Equipment to suit Hydrogen Peroxide Tank Specification. Fort Vale Engineering Ltd. 2009

AutoChanger Installation & User Guide Issue 2

R84G - Excelon Plus Modular System Pressure regulators

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

a division of Enviro Safety Products

Foundation Products. Poured In Ground Anchor Bolts E1 - E4. Structural Foundations E5 - E12. Copyright 2016 s Industry Inc. SIE-RA-CMP EN

DPS-400 SERIES DPH-100 SERIES

Workhorse-15 Oxygen Generator

EX-RECESSED CEILING LIGHT FITTINGS

JUMO dtrans p30 Pressure Transmitter

BUBBLER CONTROL SYSTEM

RPS900W Redundant Power Supply. Installation Guide.

Related Products: Auto Drain Valve. Model/Specifications. Model

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

RCP5W-RA Series. www. r o b o c y lind e r. d e. Dust-/Splash-/Water-proof RoboCylinder Rod Type with Battery-less Absolute Encoder

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

OPERATION MANUAL obl1 OPERATION MANUAL

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Operating Instructions

Transcription:

Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories

LSPHD Mountings and Accessories The following information is intented as a guide to the extensive range of optional mountings and accessories available to ensure that you get the best possible service from the investment you have made when specifying LSPHD infrared linescanning systems to monitor and control your manufacturing process. For specific recommendations on the choice of protection housing, mounting assemblies, water cooling, air purging and cabling requirements to suit your specific industry or installation, contact Land Instruments International for further advise before ordering. Mountings and Accessories Part Name Part Number Mountings Basic Mounting Plate 031.520 Water Cooled Mounting Plate 031.496 Right Angle Mounting Bracket 031.438 Enhanced Water Cooled Mounting System 800095 Light Industrial Housing 802664 Heavy Industrial Housing 802665 Floatline Mounting with Scanner Protection System 092.732 Floatline Mounting without Scanner Protection System 802663 Power Supplies and Service Panels LSPHD Industrial Power Supply for wall mounting 805037 LSPHD Industrial Power Supply for enclosure mounting 807105 LSPHD Desktop Power Supply 805024 LSPHD Floatline Service Panel 805140 Cables LSPHD 15m Low Temperature Cable 805038 LSPHD 30m Low Temperature Cable 807087 LSPHD 15m High Temperature Cable 804977 Blowers & Accessories Blower Assembly with air filter 230V 50HZ Single Phase 099.471 Blower Assembly with air filter 110V 60HZ Single Phase 099.473 Blower Assembly with air filter 220V 60HZ Single Phase 099.472 Weatherproof Blower Cover 704.374 Air Pre-filter 317.560

Basic Mounting Plate (Part Number: 031.520) The basic base plate is used in applications where an LSPHD linescanner head is to be installed in light industrial environments where the ambient temperatures is within the recommended operating range of the instrument and the atmosphere is relatively free from dust and airborne particles. Applications + Thermoforming The basic base plate provides a quick release mounting arrangement for the scanner, making realignment a simple and easy operation. Maximum Ambient Temperature 60 C / 140 F Weight 1.2 kg / 2.6 lb Dimensions (l x w x d) 276 x 176 x 52.5 mm / 10.87 x 6.93 x 2.07 in Mounting Holes Ø 8.5 mm / 0.34 in to accept M8 screws Basic Mounting Plate Part Number: 031.520 52.5/2.07 All dimensions in mm/in 22.5/0.89 276/10.87 240/9.45 152/5.98 176/6.93 Hole Ø8.5/0.34 to accept M8 screws

Water Cooled, Air Purged Base Plate (Part Number: 031.496) Applications The water cooled, air purged base plate is used in applications where an LSPHD scanner is to be installed into environments where the ambient temperatures are in the range of 60 to 100 C/140 to 212 F. It is ideally suited to general industrial applications. The air purge facility should be utilised where the operating environment is dusty and airborne particles + Glass Toughening (check ambient temperature) could contaminate the scanner viewing window. The plate provides a quick release mounting arrangement for the scanner, making realignment a simple and easy operation. Maximum Ambient Temperature 100 C / 212 F Cooling Water Requirements 1.5 to 2 litre per min / 0.4 to 0.53 USGal per min @ 30 C / 86 F Maximum Water Pressure 5.88 Bar / 85 PSI Cooling Water Connection ¼ BSP for 9.5mm / 3/8in bore water hose Air Purge Requirements 300 litre per min / 12.36 cuft per min Air Purge Connection G3/8 suitable for 38mm / 1.5in inner diameter neoprene hose Weight 2.2 kg 4.8 lb Dimensions (l x w x d) 375 x 176 x 100 mm / 14.76 x 6.93 x 3.94 in Mounting Holes Ø 8.5 mm / 0.34 in to accept M8 screws Water cooled, air purge base plate Part Number: 031.496 All dimensions in mm/in Scanner Clamp 375/14.76 Max 240/9.45 100/3.94 Max 152/5.98 176/6.93 Air purge inlet G3/8 thread. 38/1.5 I/D neoprene hose Hole Ø8.5/0.34 to accept M8 screws Water inlet/outlet 1/4BSP. 9.5/3/8 ID reinforced PVC hose

Right Angle Mounting Plate (Part Number: 031.438) The right angle mounting plate is a simple design intended for basic LSPHD linescanner head mounting. Compatibility + Designed for wall mounting of equipment It is pre-drilled to accept either the basic mounting plate or the water cooled, air purged base plate. All fixings are supplied with the plate. + Requires either the Basic Mounting Plate or the Water Cooled Mounting Plate Right angle mounting plate Part Number: 031.438 240/9.45 Stainless Steel All dimensions in mm/in 52/2.05 152/5.98 Scanner mounting face 222/8.74 Hole Ø8.5/0.34 to accept M8 screws

Enhanced Water Cooled Mounting System (Part Number: 800095) The water cooled, air purged base plate is used in applications Applications where an LSPHD scanner is to be installed into environments + Glass Toughening where the ambient temperatures are in the range of 60 to 120 C/140 to 248 F. It is ideally suited to general industrial applications. The air purge facility should be utilised where the operating environment is dusty and airborne particles could contaminate the scanner viewing window. The plate provides a quick release mounting arrangement for the scanner, making realignment a simple and easy operation. Maximum Ambient Temperature 120 C / 248 F Cooling Water Requirements Maximum Water Pressure Cooling Water Connection Air Purge Requirements Air Purge Connection Weight Dimensions (l x w x d) Mounting Holes 1.5 to 2 litre per min / 0.4 to 0.53 USGal per min @ 30 C / 86 F 5.88 Bar / 85 PSI ¼ BSP for 9.5mm / 3/8in bore water hose 300 litre per min / 12.36 cuft per min G3/8 suitable for 38mm / 1.5in inner diameter neoprene hose 8.4 kg / 18.5 lb 393 x 275 x 240 mm / 15.47 x 10.83 x 9.45 in Ø 8.5 mm / 0.34 in to accept M8 screws Enhanced Water Cooled Mounting System Part Number: 800095 All dimensions in mm/in 315/12.40 140/5.51 Scanner Clamp Air purge inlet G3/8 thread. 38/1.5 I/D neoprene hose Water inlet/outlet 1/4BSP. 9.5/3/8 ID reinforced PVC hose Hole Ø8.5/0.34 to accept M8 screws 240/9.45 204/8.03 228/8.98 275/10.83 393/15.47

Light Industrial Housing (Part Number: 802664) The light industrial housing is used in applications where an LSPHD scanner needs to be enclosed for additional protection due to airborne particulates. It can be installed into environments where the ambient temperatures are up to 150 C / 302 F. The air purge facility should be utilised where the operating environment is dusty and airborne particles could contaminate the scanner viewing window. A quick release mounting arrangement is included for the scanner, making realignment a simple and easy operation. Maximum Ambient Temperature 150 C / 302 F Cooling Water Requirements Maximum Water Pressure Cooling Water Connection Air Purge Requirements Air Purge Connection Weight Dimensions (l x w x h) Mounting Holes 1.5 to 2 litre per min / 0.4 to 0.53 USGal per min @ 30 C / 86 F 5.88 Bar / 85 PSI ¼ BSP for 9.5mm / 3/8in bore water hose 300 litre per min / 12.36 cuft per min G3/8 suitable for 38mm / 1.5in inner diameter neoprene hose 14.4 kg / 32 lb 310 x 290 x 300 mm / 12.2 x 11.42 x 11.81 in Ø 8.5 mm / 0.34 in to accept M8 screws Light Industrial Housing Part Number: 802664 w l h

Heavy Industrial Housing (Part Number: 802665) The heavy industrial housing is used in applications where an LSPHD scanner needs to be enclosed for Applications additional protection due to airborne particulates or for outdoor operation. + Strip Mill It can be installed into environments + Plate Mill where the ambient temperatures are + Rolling Mill up to 150 C / 302 F. The air purge + Outdoor facility should be utilised where the Applications operating environment is dusty and airborne particles could contaminate the scanner viewing window. A quick release mounting arrangement is included for the scanner, making realignment a simple and easy operation. Maximum Ambient Temperature 150 C / 302 F Cooling Water Requirements Maximum Water Pressure Cooling Water Connection Air Purge Requirements Air Purge Connection Weight Dimensions (l x w x d) Mounting Holes Material of Housing Cover 1.5 to 2 litre per min / 0.4 to 0.53 USGal per min @ 30 C / 86 F 5.88 Bar / 85 PSI ¼ BSP for 9.5mm / 3/8in bore water hose 300 litre per min / 12.36 cuft per min G3/8 suitable for 38mm / 1.5in inner diameter neoprene hose 29 kg / 64 lb 511 x 320 x 296.2 mm / 20.12 x 12.8 x 11.67 in Ø 18 mm / 0.71 in to accept M16 screws SUS304 Heavy Industrial Housing Part Number: 802665 511 (20.1) 472 (18.6) 436 (17.2) 16.1 27.9 Scan line Purge air inlet G3/8 thread in purge plate Purge adaptor to fit recommended Neoprene air hose Ø38mm (1.5 ) Water In/Out connection 1/4 BSP in cooling plate to accommodate water hose Ø9.5mm (3/8 ) bore Fixing bolts & washers (not supplied by Land Instruments) M16x35 hex head screw c/w plain and spring washers Gland plate fitted with M20 cable gland for STD cables 031.402 & 802406. For high temperature cable (031.794) replace M20 cable gland with M16 cable gland & adaptor (supplied with mountings), fixed in place using M20 cable gland nut

Floatline Mounting with Scanner Protection System (Part Number: 092.732) The Floatline Mounting with Scanner Protection System provides protection for the LSPHD scanner against the high ambient temperatures and heavy contamination associated with the float glass environment. The design incorporates a shutter system to isolate and protect the scanner from hot Lehr gasses in the event of a failure of the cooling or purge system. This is recommended for installations on Lehr Zones A - C. + + Applications Glass floatline on the lehr Compatibility Requires LSPHD Floatline Service Panel Maximum Ambient Temperature 150 C / 302 F Scanner Protection System Cooling Water Requirements Maximum Water Pressure Cooling Water Connection Air Purge Requirements Air Purge Connection Weight Dimensions (l x w x d) Mounting Holes Shutter mechanism activated on: Over Temperature Low/High Purge Pressure 1.5 to 2 litre per min / 0.4 to 0.53 USGal per min @ 30 C / 86 F 5.88 Bar / 85 PSI ¼ BSP for 9.5mm / 3/8in bore water hose 300 litre per min / 12.36 cuft per min @ less than 40 C / 104 F G3/8 suitable for 38mm / 1.5in inner diameter neoprene hose N/A 383 x 400 x 272 mm / 15.08 x 15.75 x 10.71 in Ø 8.5 mm / 0.34 in to accept M8 screws Floatline Mounting with Scanner Protection System Part Number: 092.732 All dimensions in mm/in 400/15.75 340/13.39 353.5/13.92 383/15.08 230/9.06 272/10.71 Single cable connection Water inlet/outlet 1/4BSP. 9.5/3/8 ID reinforced PVC hose Air purge inlet G3/8 thread. 38/1.5 I/D neoprene hose

Floatline Mounting without Scanner Protection System (Part Number: 802663) The Floatline Mounting without Scanner Protection System provides protection for the LSPHD scanner against the high ambient temperatures and heavy contamination associated with the float glass environment. The interface to the lehr cone includes a 2-axis adjustment to ensure that the scanner has a clear line of sight to the ribbon during commissioning. Applications + Glass float line on the lehr Maximum Ambient Temperature 150 C / 302 F Cooling Water Requirements Maximum Water Pressure Cooling Water Connection Air Purge Requirements Air Purge Connection Weight Dimensions (l x w x d) Mounting Holes 1.5 to 2 litre per min / 0.4 to 0.53 USGal per min @ 30 C / 86 F 5.88 Bar / 85 PSI ¼ BSP for 9.5mm / 3/8in bore water hose 300 litre per min / 12.36 cuft per min @ less than 40 C / 104 F G3/8 suitable for 38mm / 1.5in inner diameter neoprene hose N/A 393 x 275 x 240 mm / 15.47 x 10.83 x 9.45 in Ø 18 mm / 0.71 in to accept M16 screws Floatline Mounting without Scanner Protection System Part Number: 802663

Power Supplies & Service Panels LSPHD Industrial Power Supply (Part Number 805037) A terminal box which allows connection of the incoming LSPHD connection cable via an M12 industrial ethernet port, incoming mains power and the downstream data connection via either CAT 5 / 6 cable or multi-mode fibre optic. Note: Indoor use only Input Power Supply LSPHD Connection Downstream Connections Environmental Rating 100 to 240 V a.c. M12 4 pin D-Coded Industrial Ethernet Socket 1 x Multi-Mode Fibre Optic SC 3 x RJ45 Terminations IP65 Maximum Ambient Temperature 50 C / 120 F Dimensions (h x w x d) 380 x 380 x 260 mm / 15 x 15 x 10 in LSPHD Power Supply for Cabinet installation (Part Number 807105) A din rail mounted power supply unit for fitting inside cabinets. Input Power Supply LSPHD Connection Downstream Connections Environmental Rating 100 to 240 V a.c. 1 x RJ45 termination 1 x Multi-Mode Fibre Optic SC 3 x RJ45 Terminations IP65 Maximum Ambient Temperature 60 C / 140 F Dimensions Terminal rail (length) 200 mm / 8 in Note:To comply withsafety regulations the system must be mounted inside an enclosure LSPHD Desktop Power Supply (Part Number 805024) An unsealed power supply for use in clean environments to provide power for the LSPHD. Input Power Supply Instrument Connection Downstream Connections Supplied with 100 to 240 V a.c. 1 x RJ45 termination 1 x RJ45 termination M12 to RJ45 Adaptor Cable Maximum Ambient Temperature 45 C / 113 F Dimensions (h x w x d) 166 x 80 x 43.6 mm / 6.48 x 3.15 x 1.72 in

LSPHD Floatline Service Panel (Part Number 805140) The LSPHD linescanner float line system service panel provides mains power to all components of the LSPHD system, isolation facilities for servicing access and real-time system status information. The display panel can be supplied with a choice of languages to suit the local application. It provides a real-time indication of system status, including: Power On (24V) - status indication Over Temperature - warning indication Low Purge Pressure - warning indication High Purge Pressure - warning indication Shutter Not Open - status indication Manual Close - status indication Push For Manual Close - manual operation Any chosen installation site for the service panel must have low vibration, low contamination and must be within ambient temperature specification at all times (max. 50 C/90 F). The maximum cable run between the service panel installation site and the float line mountings should not exceed 15m, taking into account the safe routing of the cable. Input Power Supply LSPHD Connection Downstream Connections 100 to 240 V a.c. Maximum Ambient Temperature 50 C / 120 F Dimensions (h x w x d) M12 4 pin D-Coded Industrial Ethernet Socket 4 x RJ45 terminations 1 x Multi-Mode Fibre Optic with SC Terminations Service Panel Alarm Over Temperature Alarm Purge Pressure Alarm Shutter Not Open Alarm 510 x 510 x 250 mm / 20 x 20 x 10 in

Cables Connection cables between the LSPHD scanner and the LSPHD Power Supply unit; pre-terminated with M12 industrial ethernet connectors this single cable provides both data and Power-over- Ethernet connections. LSPHD 15m Low Temperature LSPHD 50m Low Temperature LSPHD 15m High Temperature System Cable for Floatline Mounting with Scanner Protection 15m Part Number 805038 805039 804977 031.795 Length 15 m / 49 ft 50 m / 164 ft 15 m / 49 ft 15 m / 49 ft Maximum Ambient Temperature 105 C / 220 F 105 C / 220 F 200 C / 390 F 200 C / 390 F Blowers & Accessories Accessories The plate mounted blower unit provides air to the LSPHD. Each specific application may require a controlled air supply. Optical air purging may be required in order to maintain a clear sighting window. Each blower can support up to two scanners. + A Weatherproof Blower Cover is available. This is only required for outdoor use + Air Pre-filter Option 1 Option 2 Option 3 Power Supply: 230V a.c. 110V a.c. 220V a.c. Frequency: 50Hz 60Hz 60Hz Power consumption: Circuit breaker (type C): Operating Temperature: Environmental Rating: CE marking: Weather proofing: 400W 500W 500W 10A 16A 10A -20 to 50 C/-4 to 122 F (-40 to 50 C/-40 to 122 F with optional air heater fitted) IP55/NEMA 4 (IP55/NEMA 4X (with weatherproof cover fitted) 89/336/CEE; 73/23/CEE In accordance with EN 60034-5

LSPHD Overview A complete overview of the entire product range, including the key features and benefits of all models. Ref LSPHD Overview Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners with industry leading... 150 Hz scan speed combined with 1000 samples per scan PROCESS & ANALYTICAL INSTRUMENTS Land Instruments International Ltd Dronfield S18 1DJ England Email: land.infrared@ametek.co.uk www.landinst.com Tel: +44 (0) 1246 417691 Fax: +44 (0) 1246 410585 AMETEK Land, Inc. 150 Freeport Rd Pittsburgh, PA 15238 U.S.A. Email: irsales@ametek.com www.ametek-land.com Tel: +1 (412) 826 4444 Fax: +1 (412) 826 4460 For a full list of international offices, please visit www.landinst.com Applies in the UK Applies in the USA Copyright 2010-2013 Land Continuous product development may make it necessary to change these details without notice. LSPHD -M&A/0814