Versatile, user friendly all glass sliding revolving door w26-c Maintenance Instructions and Directions for Use

Similar documents
Easy-glide allglass sliding door w17-c Maintenance Instructions and Directions for Use

INSTRUCTION MANUAL. Vertical sliding window. Product: Sliding window Version: 0.1e Language: English Original language: German Document: SF0001

Slide and Turn System SF25

Slide and Turn System SF35

Type BBS-03, BBS-05, BBS-06, BBS-25

Turnout gear is comprised of boots, coat, pants, suspenders, hood, gloves, helmet, and SCBA Facepiece.

CRANKSET 1 - TECHNICAL SPECIFICATIONS. 44,5 mm 8 mm

Rapidmain Installation Guide

Handle the film very carefully. As with aluminum foil, once creased, the film will remain creased.

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Ropes Care and Maintenance Revised

F13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS

IGUMA - IGU Design Limitations

Order No Projection Backboard

LCI Party Deck OWNER'S MANUAL

The CompacSas BAH airlock is the ideal solution for transforming an existing door into an airlock

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

1 - TECHNICAL SPECIFICATIONS

10.2. Basketball Single Post System

10.2. Basketball Single Post System

PROVIDING QUALITY SOLUTIONS FOR THE AUDIOMETRIC INDUSTRY

Horne Engineering Ltd

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

PRODUCT BULLETIN AUTOMOTIVE FILMS FPP Auto A CONTENTS

Operating and maintenance manual Filter and reducing station Series / 1.0

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Kestrel Aluminium Systems Limited. Product Manual Section 10 Thermal Framing System. Manual Version

The Outer Seal is highly abrasion resistant and provides mechanical stiffness to the splice in order to better match the cable stiffness.

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

INFINITY CLEANING & CARE GUIDE

AR-15 Rifle Operator Maintenance

SCA Series Inverted Bucket Steam Traps

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

BELT DRIVE INDOOR CYCLING BIKE SF-B1712 USER MANUAL

F776 IM_v4_ F776 INSTRUCTIONS. Liberty Security Gate Kit. With Stay-Open Feature & Additional 9cm Extension

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

ST 18 Aluminium Gas Model

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

ST 18 Aluminium Gas Model

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

Mounting instructions for digger tollo

Instrument Operating Manual

Ambient Weather GL152-TT Marine Time and Tide Clock User Manual

USER GUIDE ROLLING WALKERS INSTRUCTIONS FOR USE JANUARY, Maximum User Weight: 170kg (Do not exceed this weight)

Instructions for assembly and use ZAP telescopic platform ladder Z600

Prestige Endoscopic Graspers Instructions for Use

AR STYLE FIREARMS OWNER'S MANUAL: OPERATION, HANDLING, DISASSEMBLY / REASSEMBLY & SAFETY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS S O L O N STANDARD MODULES

General No. 25 and D-25 Handy Operating Instructions

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Kent Coffin Bollard KCB-KDTB-101/3

DM-RARD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Rear Derailleur DURA-ACE RD-R9100 ULTEGRA RD-R8000

Data Sheet VELUX INTEGRA Roller Blind

Operating instructions - Translation of the original -

User Manual. Quantos Automated Dosing Liquid Module

markilux markilux Technical Information safe timeless beautiful markilux Collection Specification markilux 1700 markilux 1700 stretch markilux

3190A NEO-ANGLE DOOR INSTALLATION INSTRUCTIONS. Series MODEL NO

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Technical Service Manual

Combination Air Valve

Less bars, more light Maxilite Aluminium Roof Lanterns

Installation and Use Manual

Sunrise Fountain Water Wonders Assembly & Mounting Instructions

Two-stage valve type NE

Operating Procedures for Metal Evaporator I

Our Spa covers. About Spa Cover Vinyl

CR Series. Special doors for clean room application

GLAUNACH THE SILENCER HANDBOOK INSTALLATION GLAUNACH GMBH ALL RIGHTS RESERVED -

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

Thanks for choosing EJAI SOLAR product

WHERE TO INSTALL THIS MIRROR

T17 Scrubber PARTS & CONSUMABLES

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Straightaway 130. Sliding & Folding Door Systems. Product Overview. Features. Technical Specifications. Coburn Product Data Sheet

Pectoral Machine. User manual E S S E N T I A L S T R E N G T H

POWER LIFT LOW PRESSURE LIFTING BAGS. Instructions for use

VTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS

System-C Tables Handling, Operation & Maintenance Manual

XERO 8 ASSEMBLY AND OPERATING INSTRUCTIONS

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

Wonder Core Smart USER S GUIDE WCS-61. Catalog Safety precautions... 1~2 Start Use... 3 How To Use... 4~5 Storage & Maintenance...

Operating Instructions

CHAPTER 2 MAINTENANCE

Sterile Visual Flow Indicator

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

Operating instruction for the quick-change tap holders type:

USER INSTRUCTIONS LARGE HOOK & STRAP ANCHORAGE CONNECTOR ! WARNING

Peak Pressure Indicator MSI-3

INTRODUCTION TO THE SERVICE RIFLE AND MAINTENANCE

Gas Sampling Fitting with MK2.1 and L-Probe

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

BLAST CABINET FOOT PEDAL & GUN INSTRUCTIONS. Item #21133

CompacSas BA. Comfort and design for high-security access

Operating Manual Body fat balance

FOLD AND ROLL PLAYBACK TABLE TENNIS TABLE

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Introduction. To check the movement number

Transcription:

Versatile, user friendly all glass sliding revolving door w26-c Maintenance Instructions and Directions for Use Important guidelines for specialist retailers and end users Please read carefully and bear in mind before using! These instructions must be kept by the end user. Maintenance Instructions and Directions for Use Version 2 2017-01-10 We reserve the right to make technical changes Item number 113039-0000 Page 1/13

1 Contents 1 Contents... 2 2 Important Notes / Safety Notes... 3 2.1 Safety Notes... 3 2.2 Reading the Maintenance Instructions and Directions for Use... 3 3 Proper and Safe Use... 3 4 Description of Construction and Function... 3 5 Maintenance Instructions... 4 5.1 Cleaning... 4 5.2 General cleaning guidelines... 4 5.3 Cleaning powder-coated aluminium profiles... 4 5.4 Cleaning glass panels... 4 5.5 Cleaning the water drains... 4 5.6 Cleaning the bottom guide profile... 4 5.7 Important Guidelines for the Winter Season... 4 5.8 Maintenance Work... 5 6 Directions for Use... 5 6.1 General Notes... 5 6.1.1 Operating in Heavy Winds... 5 6.1.2 Sliding Speed.... 5 6.2 Opening the All-Glass Sliding Revolving Door... 6 6.3 Opening the Active Leaf with Additional Lock (optional)... 7 6.4 Closing the All-Glass Sliding Revolving Door:... 8 6.5 Closing the Active Leaf with Additional Lock (optional)... 9 6.6 Notes on Panel Catch... 10 6.6.1 Opening the w26-c... 10 6.6.2 Closing the w26-c... 10 6.7 Fitting and Removing the Gap Seal (optional)... 11 7 Disposal... 12 We reserve the right to make technical changes Item number 113039-0000 Page 2/13

2 Important Notes / Safety Notes 2.1 Safety Notes Safety notes can be found at the appropriate places in the text. They are marked with a symbol and a warning text. Important Safety Note: This warning triangle marks notes about dangers which could lead to death or serious injury or which are important for the proper function of the product. 2.2 Reading the Maintenance Instructions and Directions for Use Read the Maintenance Instructions and Directions for Use before using the product for the first time. For personal safety, it is important that these instructions are complied with. Non-compliance means the manufacturer does not carry any liability. The customer must keep these instructions, and if the product is sold, they must be given to the new owner. 3 Proper and Safe Use weinor glazing elements are intended to be fitted in conservatories, under patio roofs or other connecting passages. Glazing elements may only be used for vertical glazing. Important! Please remember that certain areas require the use of laminated sheet glass (LSG) or single pane safety glass or single pane safety glass with heat-soak test. The planning and installation of glazing elements in and around parapets and areas requiring guardrails must be carried out in accordance with the applicable regulations and guidelines and are the responsibility of the foreman. 4 Description of Construction and Function Only high-quality corrosion resistant or anti-corrosion materials are used in the glazing elements. The profiles are made of extruded aluminium. All connecting parts, such as screws, are made of stainless steel. All outside aluminium parts are powder coated. We reserve the right to make technical changes Item number 113039-0000 Page 3/13

5 Maintenance Instructions 5.1 Cleaning Cleaning aluminium parts and profiles Cleaning glass panels Cleaning the bottom guide profile Cleaning the water drains 5.2 General cleaning guidelines Acids and aggressive cleaning agents such as abrasives, steel wool, scouring pads and knives/blades, as well as solvent-based cleaners (thinner, benzene) are not suitable cleaning materials and may cause irreparable damage. All regulations relating to accident prevention, environmental compliance and sealing off the immediate surroundings must be observed at all times. 5.3 Cleaning powder-coated aluminium profiles So that you may enjoy your glazing elements for many years to come, we recommend that you clean the aluminium elements at least once a year and even more often if heavily soiled. To do so, use plain water only, which may also contain minor amounts of ph-neutral or very weakly alkaline detergents. 5.4 Cleaning glass panels Use ample amounts of clean water to avoid dirt particles scratching the surface. Use neutral cleaning agents as far as possible to clean the glass panels. Do not use sharp objects to clean the glass panels as these may damage the glass. Clean sand-blasted glass surfaces (e.g. satin glass), with or without anti fingermark finish (special surface coating) using clear water and a soft cloth only. The use of aggressive alkaline-based or acid-based cleaning agents will result in damage to the anti fingermark finish. 5.5 Cleaning the water drains To ensure proper water drainage, make sure that all water drains have been cleared of coarse dirt and foreign bodies. Also clear any snow and ice in winter. 5.6 Cleaning the bottom guide profile Keep the bottom guide profile free of coarse dirt, e.g. by vacuuming. Coarse dirt can impair the smooth operation of the leaves. 5.7 Important Guidelines for the Winter Season During wintery conditions and snowfalls, and when temperatures fluctuate around freezing point, you may find snow has settled and/or ice has formed on outer parts or inside the bottom guide profile which may result in leaves or catches freezing and you being unable to use these parts. These are not product deficiencies. To restore the parts in question to full operability, you will need to free them from any snow and ice in the proper manner. We reserve the right to make technical changes Item number 113039-0000 Page 4/13

5.8 Maintenance Work Check the moving and locking mechanisms at regular intervals to ensure they are still in proper working order. Clean all parts at regular intervals that are in contact with other parts (such as the guide profiles for the leaves) and lubricate with silicone oil if required. Parts subject to wear and tear should be replaced by professionally trained staff if they are no longer functional. If construction work is being carried out near the glazing elements, ensure that all surfaces (aluminium profiles and glass) are fully protected to prevent any damage resulting from wet mortar, plaster or any other materials that might damage the glazing elements. 6 Directions for Use 6.1 General Notes The w17-c all-glass sliding revolving door is a cold element without thermal separation, with gaps between, underneath and above the leaves. As a result, the w26-c offers no heat and cold insulation and only limited means of keeping out wind or rain. Gap seals (optional extras) can be used to improve the seal of the w26-c. It is not possible to seal it entirely, however. Using gap seals increases the risk of condensation forming on the inside. The thermal energy emitted by sunlight causes exposed outer surfaces to heat up naturally. This process causes a relatively high rise in temperature (50-60 C or higher) on dark surfaces in particular. In very cold climates, however, the temperature of exposed surfaces can fall dramatically (even to below zero). Since aluminium is a very good conductor of heat, there is a potential danger that the inner surfaces will also become very hot (ranging from uncomfortably hot to a risk of burns) or very cold (potential risk of condensation forming). 6.1.1 Operating in Heavy Winds The w26-c must be closed if winds reach at least force 7 (= near gale => 13.9 17.2 m/s => 51 61 km/h => whole trees in motion; inconvenience felt when walking against wind). If not, there is a risk of damage occurring to the leaves that have been parked. 6.1.2 Sliding Speed. When sliding the leaves, never exceed a walking pace. Sliding the leaves at a faster pace or slamming them open or shut may cause damage to the locks, rollers, parking stations, outlets, glass panels and profile coating. We reserve the right to make technical changes Item number 113039-0000 Page 5/13

6.2 Opening the All-Glass Sliding Revolving Door Caution: risk of squashing! To open, turn the turn handle and swing open the active leaf. When opening, keep the turn handle in the turned position to prevent the bottom door catch from scraping across the floor (especially if a bottom guide rail has been recessed into the floor). We reserve the right to make technical changes Item number 113039-0000 Page 6/13

6.3 Opening the Active Leaf with Additional Lock (optional) Caution: risk of squashing! To open, turn the turn handle and additional lock(s). Remove the key from the additional lock at the bottom to prevent the lock from recoiling. Then swing open the active leaf. When you do this, keep the turn handle in the turned position to prevent the bottom door catch from scraping across the floor (especially if a bottom guide rail has been recessed into the floor). The two additional locks at the top and bottom do not lock in the same way. This means that the keys for the top and bottom locks are different and cannot be swapped over. We reserve the right to make technical changes Item number 113039-0000 Page 7/13

6.4 Closing the All-Glass Sliding Revolving Door: Caution: risk of squashing! To close the active leaf, turn the turn handle and swing the active leaf inwards. When you do this, keep the turn handle in the turned position to prevent the bottom door catch from scraping across the floor (especially if a bottom guide rail has been recessed into the floor). If gap seals (optional) have been fitted between the leaves, more force will be required to close the leaves as the gap seals create counter-pressure between the leaves. We reserve the right to make technical changes Item number 113039-0000 Page 8/13

6.5 Closing the Active Leaf with Additional Lock (optional) Caution: risk of squashing! Turn the turn handle to close. Make sure that the additional lock at the bottom is turn to the open position before swinging the leaves inwards. Then swing the leaves inwards. When you do this, keep the turn handle in the turned position to prevent the bottom door catch from scraping across the floor (especially if a bottom guide rail has been recessed into the floor). The two additional locks at the top and bottom do not lock in the same way. This means that the keys for the top and bottom locks are different and cannot be swapped over. We reserve the right to make technical changes Item number 113039-0000 Page 9/13

6.6 Notes on Panel Catch 6.6.1 Opening the w26-c Caution: risk of squashing! 1. Once the active leaf has been opened, swing open the next leaf. 2. Swing open the leaf until it locks into the panel catch fitted to the previously opened leaf. A Keep hold of the previously opened leaf when locking the next leaf into the panel catch. 6.6.2 Closing the w26-c 1. Keep hold of all leaves that have been parked except for the leaf that you want to close. 2. Fold the leaf inwards. Once the leaf unhinges from the panel catch, you can let go of the parked set of leaves. We reserve the right to make technical changes Item number 113039-0000 Page 10/13

6.7 Fitting and Removing the Gap Seal (optional) 1 = Determine the maximum height HS of the gap seal. 2 = Trim the gap seal accordingly. By way of preventing the gap seal from jamming between the parts directly above and below it, take off a little more from the gap seal than normal (HS-X). 3 = Attach the gap seal to the glass panel. HS = Maximum height of gap seal H = Height of w26-c a = Exterior i = Interior The gap seals can be removed from the glass panes with little effort, e.g. if the glass panes need to be cleaned. We reserve the right to make technical changes Item number 113039-0000 Page 11/13

Inserting Gap Seals A - Rectangular pipe, 50x30 - active leaf D - Leaves with 90 corner B - Active leaf leaf E - Leaves with 135 corner C - Leaf - leaf F - Leaf - rectangular pipe 50x30 7 Disposal Although this product does not contain any materials which pose a risk or danger to the environment, the parts must nevertheless be disposed of correctly. We reserve the right to make technical changes Item number 113039-0000 Page 12/13

PergoTex II/ PergoTex II LED Instructions for assembly weinor GmbH & Co. KG Mathias-Brüggen-Straße 110 50829 Cologne (Germany) www.weinor.com Hotline: +49(0)221/5 97 09-214 Fax: +49(0)221/5 97 09-898 Maintenance Instructions and Directions for Use Version 2 2017-01-10 We reserve the right to make technical changes Item number 113039-0000 Page 13/13